Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A study of three finite difference schemes and their role in asynoptic meteorological data assimilation

An investigation of three finite difference methods and their responses to the insertion of simulated satellite data is presented. A simple-one-level barotropic model is used as the forecast model, while the Mintz-Arakawa two-layer model is used to furnish the initial field, the verification fields, and the simulated satellite data. The schemes tested are the Shuman, the Matsuno-TASU, and an implicit scheme devised by McPherson. Results indicate that the schemes react to inserted data as they would react to unfiltered initial fields. Schemes which contain significant implicit viscosity are capable of damping the high frequency oscillations which occur after insertions, but such schemes may cause a loss of information. Schemes which contain less damping capability produce shock waves which damage the forecasts. It is also found that insertion of winds along with temperature data improves the forecast considerably.

Halberstan, I.↗

Thermal Testing and Integration: Magnetospheric MultiScale (MMS) Observatories with Digital 1-Wire Sensors

Thermocouples require two thin wires to be routed out of the spacecraft to connect to the ground support equipment used to monitor and record the temperature data. This large number of wires that exit the observatory complicates integration and creates an undesirable heat path during testing. These wires exiting the spacecraft need to be characterized as a thermal short that will not exist during flight. To minimize complexity and reduce thermal variables from these ground support equipment (GSE) wires, MMS pursued a hybrid path for temperature monitoring, utilizing thermocouples and digital 1-wire temperature sensors. Digital 1-wire sensors can greatly reduce harness mass, length and complexity as they can be spliced together. For MMS, 350 digital 1-wire sensors were installed on the spacecraft with only 18 wires exiting as opposed to a potential 700 thermocouple wires. Digital 1-wire sensors had not been used in such a large scale at NASAGSFC prior to the MMS mission. During the MMS thermal vacuum testing a lessons learned matrix was formulated that will assist future integration of 1-wires into thermal testing and one day into flight.

Sensors↗

Gas Generation of Heated PBX 9502

Uniaxially pressed samples of PBX 9502 were heated until self-ignition (cookoff) in order to collect pressure and temperature data relevant for model development. Samples were sealed inside a small gas-tight vessel, but were mechanically unconfined. Long-duration static pressure rise, as well as dynamic pressure rise during the cookoff event, were recorded. Time-lapse photography of the sample was used to measure the thermal expansion of the sample as a function of time and temperature. High-speed videography qualitatively characterized the mechanical behavior and failure mechanisms at the time of cookoff. These results provide valuable input to modeling efforts, in order to improve the ability to predict pressure output during cookoff as well as the effect of pressure on time-toignition.

47 OTHER INSTRUMENTATION↗

Mixed Layer Drift Revealed by Satellite Data

For the first time we are able to derive ocean currents using the wavelet algorithm for feature tracking from two different sensors (MODIS and SeaWiFS) on different satellites. Satellite ocean color data provide an important insight to the marine biosphere because of their capability to quantify certain fundamental properties (such as phytoplankton pigment concentration, marine primary production, etc.) on a global basis. The mixed layer drift can be derived because the ocean color signal bears information from a much larger depth (10 to 30 meters) as compared with the sea surface temperature data. Although the drifter data are very limited in the study area, the comparison shows a general agreement between drifter data and satellite tracking results, especially for the cases near the Gulf Stream boundary.

Liu, Antony K.↗

Thermocouple Temperature Measurements in Selective Laser Melting Additive Manufacturing

The extreme thermal history resulting from selective laser melting leads to microstructural characteristics and residual stresses that have considerable impact on the mechanical behavior of the printed part. Accurate measurements of the temperature combined with thermal models are needed to better understand and control the thermal history to optimize mechanical properties. In order to calibrate and validate models, experimental temperature data must be accurately measured in a rapid fashion due to the high speeds of the laser. In this work, a novel method to read data from thermocouples is created with enhanced circuitry that achieves a sampling rate of 10 kHz. This data acquisition rate allows for high precision sampling of SLM heating and cooling cycles.

additive manufacturing↗

Solar-induced oscillations in the stratosphere - A myth or reality?

Chandra (1984) has provided an assessment of the solar cycle ozone relationship based on seven years of Nimbus 4 BUV (backscattered ultraviolet) data. It was found that the globally averaged ozone in the upper stratosphere, when corrected for the changes in instrument sensitivity, decreased from 1970 to 1976 by 3-4 percent. This decrease is in accordance with the current estimates of solar UV variability over a solar cycle. The present investigation has the objective to determine if measured changes in ozone and temperature in the upper stratosphere on a time scale of a solar rotation are of solar origin, i.e., directly induced by changes in solar irradiance. The conducted study is based on the first two years (1970-1972) of ozone and temperature data obtained from the Nimbus 4 BUV and the Selective Chopper Radiometer (SCR) experiments. Attention is given to the response of the stratosphere to changes in solar activity associated with the 27-day solar rotation.

Chandra, S.↗

Evaluation of pressure and thermal data from a wind tunnel test of a large-scale, powered, STOL fighter model

A STOL fighter model employing the vectored-engine-over wing concept was tested at low speeds in the NASA/Ames 40 by 80-foot wind tunnel. The model, approximately 0.75 scale of an operational fighter, was powered by two General Electric J-97 turbojet engines. Limited pressure and thermal instrumentation were provided to measure power effects (chordwise and spanwise blowing) and control-surface-deflection effects. An indepth study of the pressure and temperature data revealed many flow field features - the foremost being wing and canard leading-edge vortices. These vortices delineated regions of attached and separated flow, and their movements were often keys to an understanding of flow field changes caused by power and control-surface variations. Chordwise blowing increased wing lift and caused a modest aft shift in the center of pressure. The induced effects of chordwise blowing extended forward to the canard and significantly increased the canard lift when the surface was stalled. Spanwise blowing effectively enhanced the wing leading-edge vortex, thereby increasing lift and causing a forward shift in the center of pressure.

Howell, G. A.↗

Groups and the Entropy Floor: XMM-Newton Observations of Two Groups

Using XMM-Newton spatially resolved X-ray imaging spectroscopy we obtain the temperature, density, entropy, gas mass, and total mass profiles for two groups of galaxies out to approximately 0.3 R(sub vir)(R(sub vir), the virial radius). Our density profiles agree well with those derived previously, and the temperature data are broadly consistent with previous results but are considerably more precise. Both of these groups are at the mass scale of 2x10(exp 13) M(solar mass), but have rather different properties. Both have considerably lower gas mass fractions at r < 0.3 R(sub vir), than the rich clusters. NGC2563, one of the least luminous groups for its X-ray temperature, has a very low gas mass fraction of approximately 0.004 inside 0.1 R(sub vir), which increases with radius. NGC4325, one of the most luminous groups at the same average temperature, has a higher gas mass fraction of 0.02. The entropy profiles and the absolute values of the entropy as a function of virial radius also differ, with NGC4325 having a value of approximately 100 keV cm(exp -2) and NGC2563 a value of approximately 300 keV cm(exp -2) at r approximately 0.1 R(sub vir). For both groups the profiles rise monotonically with radius and there is no sign of an entropy 'floor'. These results are inconsistent with pre-heating scenarios that have been developed to explain a possible entropy floor in groups, but are broadly consistent with models of structure formation that include the effects of heating and/or the cooling of the gas. The total entropy in these systems provides a strong constraint on all models of galaxy and group formation, and on the poorly defined feedback process that controls the transformation of gas into stars and thus the formation of structure in the universe.

Mushotzky, R. F.↗

Two-photon LIF on the HIT-SI3 experiment: Absolute density and temperature measurements of deuterium neutrals

Two-photon laser-induced fluorescence measurements were performed on the helicity injected torus (HIT-SI3) device to determine the density and temperature of the background neutral deuterium population. Measurements were taken in 2 ms long pulsed plasmas after the inductive helicity injectors were turned off. Attempts to measure neutrals during the main phase of the plasma were unsuccessful, likely due to the density of neutrals being below the detection threshold of the diagnostic. An unexpectedly low density of atomic deuterium was measured in the afterglow; roughly 100 times lower than the theoretical prediction of 10{sup 17} m{sup −3}. The neutral temperatures measured were on the order of 1 eV. Temporally and spatially resolved neutral density and temperature data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variations of radiative heating/cooling in the stratosphere as revealed by satellite observations

Ozone observations made by Stratospheric Aerosol and Gas Experiment (SAGE) and meteorological temperature data are used to study the coupling of radiation and dynamics in the stratosphere. Both radiative heating and cooling rates are calculated using the observations as a function of altitude, longitude, latitude, and season. Fourier analysis of heating/cooling rates is performed to gain an understanding of the radiation-planetary wave interactions. High correlation is seen to exist between solar heating and the temperature distribution of the upper stratosphere. Radiative damping coefficients are derived and it is found that the coupling between ozone and temperature can produce significant variations in the damping rate which, in turn, critically depends on the vertical structure of the planetary waves.

Wang, P.-H.↗

Soil Moisture Active Passive Mission L4_SM Data Product Assessment (Version 2 Validated Release)

During the post-launch SMAP calibration and validation (Cal/Val) phase there are two objectives for each science data product team: 1) calibrate, verify, and improve the performance of the science algorithm, and 2) validate the accuracy of the science data product as specified in the science requirements and according to the Cal/Val schedule. This report provides an assessment of the SMAP Level 4 Surface and Root Zone Soil Moisture Passive (L4_SM) product specifically for the product's public Version 2 validated release scheduled for 29 April 2016. The assessment of the Version 2 L4_SM data product includes comparisons of SMAP L4_SM soil moisture estimates with in situ soil moisture observations from core validation sites and sparse networks. The assessment further includes a global evaluation of the internal diagnostics from the ensemble-based data assimilation system that is used to generate the L4_SM product. This evaluation focuses on the statistics of the observation-minus-forecast (O-F) residuals and the analysis increments. Together, the core validation site comparisons and the statistics of the assimilation diagnostics are considered primary validation methodologies for the L4_SM product. Comparisons against in situ measurements from regional-scale sparse networks are considered a secondary validation methodology because such in situ measurements are subject to up-scaling errors from the point-scale to the grid cell scale of the data product. Based on the limited set of core validation sites, the wide geographic range of the sparse network sites, and the global assessment of the assimilation diagnostics, the assessment presented here meets the criteria established by the Committee on Earth Observing Satellites for Stage 2 validation and supports the validated release of the data. An analysis of the time average surface and root zone soil moisture shows that the global pattern of arid and humid regions are captured by the L4_SM estimates. Results from the core validation site comparisons indicate that "Version 2" of the L4_SM data product meets the self-imposed L4_SM accuracy requirement, which is formulated in terms of the ubRMSE: the RMSE (Root Mean Square Error) after removal of the long-term mean difference. The overall ubRMSE of the 3-hourly L4_SM surface soil moisture at the 9 km scale is 0.035 cubic meters per cubic meter requirement. The corresponding ubRMSE for L4_SM root zone soil moisture is 0.024 cubic meters per cubic meter requirement. Both of these metrics are comfortably below the 0.04 cubic meters per cubic meter requirement. The L4_SM estimates are an improvement over estimates from a model-only SMAP Nature Run version 4 (NRv4), which demonstrates the beneficial impact of the SMAP brightness temperature data. L4_SM surface soil moisture estimates are consistently more skillful than NRv4 estimates, although not by a statistically significant margin. The lack of statistical significance is not surprising given the limited data record available to date. Root zone soil moisture estimates from L4_SM and NRv4 have similar skill. Results from comparisons of the L4_SM product to in situ measurements from nearly 400 sparse network sites corroborate the core validation site results. The instantaneous soil moisture and soil temperature analysis increments are within a reasonable range and result in spatially smooth soil moisture analyses. The O-F residuals exhibit only small biases on the order of 1-3 degrees Kelvin between the (re-scaled) SMAP brightness temperature observations and the L4_SM model forecast, which indicates that the assimilation system is largely unbiased. The spatially averaged time series standard deviation of the O-F residuals is 5.9 degrees Kelvin, which reduces to 4.0 degrees Kelvin for the observation-minus-analysis (O-A) residuals, reflecting the impact of the SMAP observations on the L4_SM system. Averaged globally, the time series standard deviation of the normalized O-F residuals is close to unity, which would suggest that the magnitude of the modeled errors approximately reflects that of the actual errors. The assessment report also notes several limitations of the "Version 2" L4_SM data product and science algorithm calibration that will be addressed in future releases. Regionally, the time series standard deviation of the normalized O-F residuals deviates considerably from unity, which indicates that the L4_SM assimilation algorithm either over- or under-estimates the actual errors that are present in the system. Planned improvements include revised land model parameters, revised error parameters for the land model and the assimilated SMAP observations, and revised surface meteorological forcing data for the operational period and underlying climatological data. Moreover, a refined analysis of the impact of SMAP observations will be facilitated by the construction of additional variants of the model-only reference data. Nevertheless, the “Version 2” validated release of the L4_SM product is sufficiently mature and of adequate quality for distribution to and use by the larger science and application communities.

SMAP L4_SM↗

Effect of Melt Convection and Solid Transport on Macrosegregation and Grain Structure in Equiaxed Al-Cu Alloys

Macrosegregation in metal casting can be caused by thermal and solutal melt convection, and the transport of unattached solid crystals. These free grains can be a result of, for example, nucleation in the bulk liquid or dendrite fragmentation. In an effort to develop a comprehensive numerical model for the casting of alloys, an experimental study has been conducted to generate benchmark data with which such a solidification model could be tested. The specific goal of the experiments was to examine equiaxed solidification in situations where sinking of grains is (and is not) expected. The objectives were: 1) experimentally study the effects of solid transport and thermosolutal convection on macrosegregation and grain size distribution patterns; and 2) provide a complete set of controlled thermal boundary conditions, temperature data, segregation data, and grain size data, to validate numerical codes. The alloys used were Al-1 wt. pct. Cu, and Al-10 wt. pct. Cu with various amounts of the grain refiner TiB2 added. Cylindrical samples were either cooled from the top, or the bottom. Several trends in the data stand out. In attempting to model these experiments, concentrating on experiments that show clear trends or differences is recommended.

Rerko, Rodney S.↗

Argon equation of state data to 1 TPa: Shock compression experiments and simulations

Argon is the most abundant noble gas on Earth and its noble, atomic fluid nature makes it an excellent candidate for comparison of experiment and theory at extreme conditions. For this study, we performed a combined computational and experimental study on shock compressed cryogenic liquid argon. Using Sandia's Z machine, we shock compressed liquid argon to 600 GPa and reshock states up to 950 GPa. Laser shock experiments at the Omega Laser facility extend the principal Hugoniot to 1000 GPa and provided temperature data along the principal Hugoniot. The plate impact experiments and laser shock experiments used well-characterized impedance matching standards and demonstrate consistent results between the two platforms over a common range. Density functional theory based molecular dynamics simulations provided additional data on the Hugoniot to 600 GPa. The combined experimental data and simulation results provide constraints on the development of new equation of state models at extreme conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aerothermal test results from the first flight of the Pegasus air-launched space booster

A survey of temperature measurements at speeds through Mach 8.0 on the first flight of the Pegasus air-launched booster system is discussed. In addition, heating rates were derived from the temperature data obtained on the fuselage in the vicinity of the wing shock interaction. Sensors were distributed on the wing surfaces, leading edge, and on the wing-body fairing or fillet. Side-by-side evaluations were obtained for a variety of sensor installations. Details of the trajectory reconstruction through first-stage separation are provided. Given here are indepth descriptions of the sensor installations, temperature measurements, and derived heating rates along with interpretations of the results.

Noffz, Gregory K.↗

Directional Solidification of Bi-Sn on USMP-4

The experiments used MEPHISTO hardware to study the solidification and melting behavior of bismuth alloyed with 1 at% tin. Three samples, each approximately 900 mm long and 6mm in diameter, were used. A portion of each sample also included a 2 mm diameter growth capillary, to assist in the formation of a single grain. One sample provided the Seebeck voltage generated during melting and freezing processes. Another provided temperature data and Peltier pulsed demarcation of the interface shape for post flight analysis. The third sample provided resistance and growth velocity measurements, as well as additional thermal data. The third sample was also quenched at the end of the mission to preserve the composition of the liquid near the interface for post flight determination. A total of 450mm of directionally solidified samples were preserved for post mission structural and compositional characterization. Substantial differences were observed in the Seebeck signal between the ground-based experiments and the space-based experiments. The temperature gradient in the liquid for the ground-based experiments was significantly lower than the temperature gradient in the liquid for the space-based experiments.

Abbaschian, Reza↗

Optical observations of thermospheric dynamics at Arecibo

A description is given of wind and temperature data obtained with a 15-cm Fabry-Perot interferometer. The observations were made between February and August 1980 and confirm the details of the conceptual model of Herrero and Meriwether (1980). Attention is given to the method used to analyze the neutral wind field, the zonal winds, the meridional wind, the horizontal wind gradient, the vertical wind velocity, the full wind field, and the neutral temperature. The most regular feature of the neutral wind at Arecibo is the zonal component, which has a peak velocity in the eastward direction near sunset, and decreases in velocity as the night progresses. Both the wind and temperature measurements reported provide ample confirmation of the importance of the equatorial midnight pressure bulge in modifying the dynamic behavior of the nighttime thermosphere at Arecibo.

Burnside, R. G.↗

Tropical Convection's Roles in Tropical Tropopause Cirrus

Remote sensing observations reveal the frequent occurrence of tropopause cirrus, thin cirrus layers located near the tropical cold-point tropopause. Here, we present a theory in which tropical convection plays several important roles in tropopause cirrus formation. First, tropical convection is the primary means by which the moisture required for tropopause cirrus formation is transported into the upper troposphere. However, previous studies suggest that this convection rarely penetrates to the altitudes at which tropopause cirrus layers are observed, suggesting that additional vertical moisture transport is required to explain tropopause cirrus formation. We propose a mechanism for explaining this transport in which tropical convection plays the key role. According to this hypothesis, the transport is accomplished by meridional circulations that develop within the tropopause transition layer (TTL) in response to momentum transport by Rossby waves generated by tropical convection. Results of a series of global scale model runs designed to test this hypothesis will be presented. In addition, reanalyses vertical velocity data will be examined for evidence of the expected correlation between large-scale rising motion within the TTL and tropical convection. Once moisture is present near the cold-point tropopause, large-scale cooling is required to initiate tropopause cirrus formation. One source of this cooling is stratospheric tropical waves induced by tropical convection, as we will show using a time series of radiosonde temperature data superimposed with data on cloud occurrence from the DOE ARM Nauru99 field experiment. Observations of the global characteristics of these waves from a longer time series of reanalysis data will also be presented.

Boehm, Matthew T.↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zoned results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space environment Simulator (SES). The flight external radiators are not available during ISIM-level thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided by specially designed test hardware which also measures the heat flow within each of the five heat straps to an accuracy of less than 2 mW, which is less than 5% of the minimum predicted heat flow values. Measurement of the heat loads to this accuracy is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. It also provides direct verification by test of several high-level thermal requirements. Devices that measure heat flow in this manner have historically been referred to a "Q-meters". Perhaps the most important feature of the design of the JWST Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on knowledge of precise heater power required to maintain a constant temperature difference between sensors on two stages, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper provides a brief review of Q-meter design, and discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗