Search NASA⌕ Search

SEARCH · Search NASA

Results for “test protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

JAXA-NASA Interoperability Demonstration for Application of DTN Under Simulated Rain Attenuation

As is well known, K-band or higher band communications in space link segment often experience intermittent disruptions caused by heavy rainfall. In view of keeping data integrity and establishing autonomous operations under such situation, it is important to consider introducing a tolerance mechanism such as Delay/Disruption Tolerant Networking (DTN). The Consultative Committee for Space Data Systems (CCSDS) is studying DTN as part of the standardization activities for space data systems. As a contribution to CCSDS and a feasibility study for future utilization of DTN, Japan Aerospace Exploration Agency (JAXA) and National Aeronautics and Space Administration (NASA) conducted an interoperability demonstration for confirming its tolerance mechanism and capability of automatic operation using Data Relay Test Satellite (DRTS) space link and its ground terminals. Both parties used the Interplanetary Overlay Network (ION) open source software, including the Bundle Protocol, the Licklider Transmission Protocol, and Contact Graph Routing. This paper introduces the contents of the interoperability demonstration and its results.

Suzuki, Kiyoshisa↗

Use of IPsec by Manned Space Missions

NASA's Constellation Program is developing its next generation manned space systems for missions to the International Space Station (ISS) and the Moon. The Program is embarking on a path towards standards based Internet Protocol (IP) networking for space systems communication. The IP based communications will be paired with industry standard security mechanisms such as Internet Protocol Security (IPsec) to ensure the integrity of information exchanges and prevent unauthorized release of sensitive information in-transit. IPsec has been tested in simulations on the ground and on at least one Earth orbiting satellite, but the technology is still unproven in manned space mission situations and significant obstacles remain.

Pajevski, Michael J.↗

Bone Loss During Spaceflight: Available Models and Counter-Measures

There is ongoing concern for human health during spaceflights. Of particular interest is the uncoupling of bone remodeling and its resultant effect on calcium metabolism and bone loss. The calculated average loss of bone mineral density (BMD) is approximately 1-1.5% per month of spaceflight. The effect of decreased BMD on associated fractures in astronauts is not known. Currently on the International Space Station (ISS), bone loss is managed through dietary supplements and modifications and resistance exercise regimen. As the duration of space flights increases, a review of the current methods available for the prevention of bone loss is warranted. The goal of this project is to review and summarize recent studies that have focused on maintaining BMD during exposure to microgravity. Interventions were divided into physical (Table 1), nutritional (Table 2), or pharmacologic (Table 3) categories. Physical modalities included resistance exercise, low level vibration, and low intensity pulsed ultrasound. Nutritional interventions included altering protein, salt, and fat intake; and vitamin D supplementation. Pharmacologic interventions included the use of bisphosphonates and beta blockers. Studies reported outcomes based on bone density determined by DXA bone scan, micro-architecture of histology and microCT, and serum and urine markers of bone turnover. The ground analog models utilized to approximate osseous physiology in microgravity included human patients previously paralyzed or subjects confined to bedrest. Ground analog animal models include paralysis, immobilization and ovariectomies. As a result of the extensive research performed there is a multi-modality approach available for the management of BMD during spaceflight that includes resistance training, nutrition and dietary supplements. However, there is a paucity of literature describing a formalized tiered protocol to guide investigators through the progression from animal models to human patient ground analogs to experiments on the ISS. With regards to testing, further evaluation to determine the association between non-invasive tests and fracture during and after spaceflight needs to be performed.

Morris, Jonathan↗

Calibration and Validation of a Finite ELement Model of THor-K Anthropomorphic Test Device for Aerospace Safety Applications

The THOR anthropomorphic test device (ATD) has been developed and continuously improved by the National Highway Traffic Safety Administration to provide automotive manufacturers an advanced tool that can be used to assess the injury risk of vehicle occupants in crash tests. Recently, a series of modifications were completed to improve the biofidelity of THOR ATD [1]. The updated THOR Modification Kit (THOR-K) ATD was employed at Wright-Patterson Air Base in 22 impact tests in three configurations: vertical, lateral, and spinal [2]. Although a computational finite element (FE) model of the THOR had been previously developed [3], updates to the model were needed to incorporate the recent changes in the modification kit. The main goal of this study was to develop and validate a FE model of the THOR-K ATD. The CAD drawings of the THOR-K ATD were reviewed and FE models were developed for the updated parts. For example, the head-skin geometry was found to change significantly, so its model was re-meshed (Fig. 1a). A protocol was developed to calibrate each component identified as key to the kinematic and kinetic response of the THOR-K head/neck ATD FE model (Fig. 1b). The available ATD tests were divided in two groups: a) calibration tests where the unknown material parameters of deformable parts (e.g., head skin, pelvis foam) were optimized to match the data and b) validation tests where the model response was only compared with test data by calculating their score using CORrelation and Analysis (CORA) rating system. Finally, the whole ATD model was validated under horizontal-, vertical-, and lateral-loading conditions against data recorded in the Wright Patterson tests [2]. Overall, the final THOR-K ATD model developed in this study is shown to respond similarly to the ATD in all validation tests. This good performance indicates that the optimization performed during calibration by using the CORA score as objective function is not test specific. Therefore confidence is provided in the ATD model for uses in predicting response in test conditions not performed in this study such those observed in the spacecraft landing. Comparison studies with ATD and human models may also be performed to contribute to future changes in THOR ATD design in an effort to improve its biofidelity, which has been traditionally based on post-mortem human subject testing and designer experience.

Putnam, J. B.↗

Advanced Cardiac Life Support (ACLS) utilizing Man-Tended Capability (MTC) hardware onboard Space Station Freedom

Because of the time and distance involved in returning a patient from space to a definitive medical care facility, the capability for Advanced Cardiac Life Support (ACLS) exists onboard Space Station Freedom. Methods: In order to evaluate the effectiveness of terrestrial ACLS protocols in microgravity, a medical team conducted simulations during parabolic flights onboard the KC-135 aircraft. The hardware planned for use during the MTC phase of the space station was utilized to increase the fidelity of the scenario and to evaluate the prototype equipment. Based on initial KC-135 testing of CPR and ACLS, changes were made to the ventricular fibrillation algorithm in order to accommodate the space environment. Other constraints to delivery of ACLS onboard the space station include crew size, minimum training, crew deconditioning, and limited supplies and equipment. Results: The delivery of ACLS in microgravity is hindered by the environment, but should be adequate. Factors specific to microgravity were identified for inclusion in the protocol including immediate restraint of the patient and early intubation to insure airway. External cardiac compressions of adequate force and frequency were administered using various methods. The more significant limiting factors appear to be crew training, crew size, and limited supplies. Conclusions: Although ACLS is possible in the microgravity environment, future evaluations are necessary to further refine the protocols. Proper patient and medical officer restraint is crucial prior to advanced procedures. Also emphasis should be placed on early intubation for airway management and drug administration. Preliminary results and further testing will be utilized in the design of medical hardware, determination of crew training, and medical operations for space station and beyond.

Smith, M.↗

In-Depth Analysis of Subject Functional Performance and Subjective Feedback Data for Evaluating Argos Simulation Quality

Mechanical offloading systems such as the Active Response Gravity Offload System (ARGOS) at NASA Johnson Space Center (JSC) are used to simulate various partial gravity environments. ARGOS offloads pressurized suited subjects through a gimbaling pivot point system attached to a volumetric Portable Life Support System (PLSS). The pivot point can be configured to multiple locations with respect to the human-suit system center of gravity (CG). Previous work has tested and documented the interaction between different pivot point locations and measured CG. Observations indicated that small changes in pivot point location substantially affect the stability and functional performance (simulation quality) of a subject. This led to the development of a standardized gimbal assessment protocol to assess the functional performance of a pressurized suited subject as a function of the pivot point location, using the data obtained from a variety of planetary suit mobility tasks. As a result, an expansive repository of CG-related task metrics was generated from numerous ARGOS spacesuit test events, for different gimbal configurations and different test subjects. Based on the evaluation metrics and observed trends, several pivot point locations were iteratively identified to determine an “appropriate/optimal” configuration. This study thus describes the in-depth analysis of the CG evaluation metrics to better quantify trends and determine if specific factors are strongly associated with appropriate/optimal configurations. Quantitative and qualitative variables relating to subject task performance, subjective feedback, and anthropometry will be evaluated via probabilistic methods. The results from this study are expected to improve our understanding of optimal ARGOS gimbal settings, which will better inform the gimbal configuration identification process and improve simulation quality for extravehicular activity (EVA) training.

Joseph Yao↗

WISE-2005: LBNP/Treadmill and Resistive Exercise Countermeasures Maintain Aerobic Capacity during a 60-d Bed Rest

We have previously documented that supine treadmill exercise within lower body negative pressure (LBNPex) performed 6 sessions (raised dot) wk(sup -1) during 15- and 30-day bed rests (BR) maintained upright aerobic capacity (VO2pk). In the present study, ure are evaluating whether aerobic capacity is maintained during a 60-d BR when the LBNPex frequency is reduced to 2-4 sessions (raised dot) wk(sup -1) and resistance exercise (REX) is added 2-3 sessions (raised dot) wk(sup -1). Eight healthy women (32 plus or minus 4 yrs; 56.4 plus or minus 3.6 kg; 164 plus or minus 8 cm; mean plus or minus SD) performed maximal-exertion, graded treadmill tests before and 3 days after a 60-d, 6 deg. head-down tilt BR. (Earliest day the medical monitors would permit a maximal exercise test post-BR). During BR, four subjects performed no exercise (CON), while four other subjects (EX) performed LBNPex and REX on separate days. The LBNPex countermeasure employed an intermittent (40-80% pre-BR VO2pk), 40-min protocol against an LBNP pressure (-49 plus or minus 3 mmHg) applied to provide a footward force equivalent to 1.0-1.2 body weight. REX consisted of maximal concentric and eccentric supine leg press and heel raise exercises using a gravity-independent flywheel ergometer. Comparisons were performed using paired (within-group) or non-paired (between-group) t-tests. Three days post-BR, VO2pk of the CON group was reduced significantly from pre-BR (Pre:37.2 plus or minus 1.2, Post: 29.4 plus or minus 2 ml (raised dot) kg(sup -1) (raised dot) min(sup -1), P less than 0.05), while the VO2pk of the EX group was not significantly reduced (Pre: 39.6 plus or minus 1.9, Post: 38.0 plus or minus 0.6 ml (raised dot) kg(sup -1) (raised dot) min(sup -1)). Peak heart rate, ventilation, rating of perceived exertion, and respiratory exchange ratio were not significantly different between the two groups pre- and post-BR. These preliminary results suggest that the combined LBNPex and REX countermeasures may be sufficient to maintain upright aerobic capacity after long-duration space flights.

Schneider, Suzanne M.↗

Organic Contamination Baseline Study in NASA Johnson Space Center Astromaterials Curation Laboratories

Future robotic and human spaceflight missions to the Moon, Mars, asteroids, and comets will require curating astromaterial samples with minimal inorganic and organic contamination to preserve the scientific integrity of each sample. 21st century sample return missions will focus on strict protocols for reducing organic contamination that have not been seen since the Apollo manned lunar landing program. To properly curate these materials, the Astromaterials Acquisition and Curation Office under the Astromaterial Research and Exploration Science Directorate at NASA Johnson Space Center houses and protects all extraterrestrial materials brought back to Earth that are controlled by the United States government. During fiscal year 2012, we conducted a year-long project to compile historical documentation and laboratory tests involving organic investigations at these facilities. In addition, we developed a plan to determine the current state of organic cleanliness in curation laboratories housing astromaterials. This was accomplished by focusing on current procedures and protocols for cleaning, sample handling, and storage. While the intention of this report is to give a comprehensive overview of the current state of organic cleanliness in JSC curation laboratories, it also provides a baseline for determining whether our cleaning procedures and sample handling protocols need to be adapted and/or augmented to meet the new requirements for future human spaceflight and robotic sample return missions.

Calaway, Michael J.↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COOP 3D ARPA Experiment 109 National Center for Atmospheric Research

Coupled atmospheric and hydrodynamic forecast models were executed on the supercomputing resources of the National Center for Atmospheric Research (NCAR) in Boulder, Colorado and the Ohio Supercomputing Center (OSC)in Columbus, Ohio. respectively. The interoperation of the forecast models on these geographically diverse, high performance Cray platforms required the transfer of large three dimensional data sets at very high information rates. High capacity, terrestrial fiber optic transmission system technologies were integrated with those of an experimental high speed communications satellite in Geosynchronous Earth Orbit (GEO) to test the integration of the two systems. Operation over a spacecraft in GEO orbit required modification of the standard configuration of legacy data communications protocols to facilitate their ability to perform efficiently in the changing environment characteristic of a hybrid network. The success of this performance tuning enabled the use of such an architecture to facilitate high data rate, fiber optic quality data communications between high performance systems not accessible to standard terrestrial fiber transmission systems. Thus obviating the performance degradation often found in contemporary earth/satellite hybrids.

Source record↗

Effects of Artificial Gravity and Bed Rest on Spatial Orientation and Balance Control

While the vestibular system should be well-adapted to bed rest (a condition it experiences approximately 8/24 hrs each day), questions remain regarding the degree to which repeated exposures to the unusual gravito-inertial force environment of a short-radius centrifuge might affect central processing of vestibular information used in spatial orientation and balance control. Should these functions be impaired by intermittent AG, its feasibility as a counter-measure would be diminished. We, therefore, examined the effects of AG on spatial orientation and balance control in 15 male volunteers before and after 21 days of 6 HDT bed rest (BR). Eight of the subjects were treated with daily 1hr AG exposures (2.5g at the feet; 1.0g at the heart) aboard a short radius (3m) centrifuge, while the other seven served as controls (C). Spatial orientation was assessed by measures of ocular counter-rolling (OCR; rotation of the eye about the line of sight, an otolith-mediated reflex) and subjective visual vertical (SVV; perception of the spatial upright). Both OCR and SVV measurements were made with the subject upright, lying on their left sides, and lying on their right sides. OCR was measured from binocular eye orientation recordings made while the subjects fixated for 10s on a point target directly in front of the face at a distance of 1 m. SVV was assessed by asking subjects (in the dark) to adjust to upright (using a handheld controller) the orientation of a luminous bar randomly perturbed (15) to either side of the vertical meridian. Balance control performance was assessed using a computerized dynamic posturography (CDP) protocol similar to that currently required for all returning crew members. During each session, the subjects completed a combination of trials of sensory organization test (SOT) 2 (eyes closed, fixed platform) and SOT 5 (eyes closed, sway-referenced platform) with and without static and dynamic pitch plane head movements (plus or minus 20 deg., dynamic paced by an audible tone at 0.33Hz). OCR and CDP performance were unaffected by BR and BR+AG; post-BR measures were unchanged from baseline for both AG and C groups. Similarly, BR did not affect SVV in the C group. However, BR+AG disrupted one measure of spatial orientation: SVV error was significantly increased on R+0 and R+1 following BR in the AG group. These results suggest a transient untoward effect on central vestibular processing may accompany repeated exposure to intermittent AG, a potential side-effect that should be studied more closely in future studies.

Paloski, William H.↗

Closed-Loop Analysis of Soft Decisions for Serial Links

We describe the benefit of using closed-loop measurements for a radio receiver paired with a counterpart transmitter. We show that real-time analysis of the soft decision output of a receiver can provide rich and relevant insight far beyond the traditional hard-decision bit error rate (BER) test statistic. We describe a Soft Decision Analyzer (SDA) implementation for closed-loop measurements on single- or dual- (orthogonal) channel serial data communication links. The analyzer has been used to identify, quantify, and prioritize contributors to implementation loss in live-time during the development of software defined radios. This test technique gains importance as modern receivers are providing soft decision symbol synchronization as radio links are challenged to push more data and more protocol overhead through noisier channels, and software-defined radios (SDRs) use error-correction codes that approach Shannon's theoretical limit of performance.

Lansdowne, Chatwin A.↗

Soft Decision Analyzer

We describe the benefit of using closed-loop measurements for a radio receiver paired with a counterpart transmitter. We show that real-time analysis of the soft decision output of a receiver can provide rich and relevant insight far beyond the traditional hard-decision bit error rate (BER) test statistic. We describe a Soft Decision Analyzer (SDA) implementation for closed-loop measurements on single- or dual- (orthogonal) channel serial data communication links. The analyzer has been used to identify, quantify, and prioritize contributors to implementation loss in live-time during the development of software defined radios. This test technique gains importance as modern receivers are providing soft decision symbol synchronization as radio links are challenged to push more data and more protocol overhead through noisier channels, and software-defined radios (SDRs) use error-correction codes that approach Shannon's theoretical limit of performance.

Lansdowne, Chatwin↗

Evaluating Differences Among Crop Models in Simulating Soybean in-Season Growth

Crop models are useful tools for simulating agricultural systems that require continued model development and testing to increase their robustness and improve how they describe our current understanding of processes. Coordinated and “blind” evaluation of multiple models using same protocols and experimental datasets provides unique opportunities to further improve models and enhance their reliability. For soybean [Glycine max (L.) Merr.], there has been limited coordinated multi-model evaluations for the simulation of in-season plant growth dynamics. We evaluated ten dynamic soybean crop models for their simulation of in-season plant growth using data from five experiments conducted in Argentina, Brazil, France, and USA. We evaluated models after a Blind (using only phenology data) and a Full calibration (with in-season and end-of-season variables). Calibration reduced model uncertainty by reducing standard bias for the simulation of in-season variables (biomass, leaf, pod, and stem weights, and leaf area index, LAI). However, we found that most models had difficulty in reproducing leaf growth dynamics, with normalized root mean squared error (nRMSE) of 56% for leaf weight and 43% for LAI (across locations and models after Full calibration). Models with different levels of complexity and experience were capable of simulating final seed yield at maturity with reasonable accuracy (nRMSE of 8–31% after Full calibration). However, the nRMSE for pod weight (of 17–64% after Full calibration) was two-fold larger than that of seed yield. Moreover, the models differed in how they simulated timing from sowing to beginning seed growth (47–93 days) and effective seed filling period (18–54 days), owing to model structural differences in defining the reproductive developmental stages. Overall, we identified the following processes that can benefit from further model improvement: leaf expansion and senescence, reproductive phenology, and partitioning to reproductive growth. Simulation of pod wall tissue and individual seed cohorts is another aspect that many models currently lack. Model improvement can benefit from high-temporal resolution experimental datasets that concurrently account for phenology, plant growth, and partitioning. Further, we recommend collecting reproductive phenology in the field consistent with actual dry matter allocation to organs in the models and collecting multiple observations of seed and pod weight to aid model improvement for simulation of seed growth and yield formation.

Agricultural Model Intercomparison and Improvement↗

MR imaging of hand microcirculation as a potential tool for space glove testing and design

The task of evaluating and designing space gloves requires accurate biomechanical characterization of the hand. The availability of magnetic resonance (MR) imaging has created new opportunities for in vivo analysis of physiological phenomena such as the relationship between circulation and fatigue. An MR imaging technique originally proposed to quantitatively evaluate cerebral perfusion has been modified to evaluate the capillary microcirculation in hand muscles. An experimental protocol was developed to acquire perfusion-weighted images in the hand before and after various levels of exercise. Preliminary results on the feasibility of applying the MR imaging technique to the study of microcirculation and fatigue in the hand are presented. The potential of this method for space glove testing and design is also discussed.

Peterson, Steven W.↗

The Verification-based Analysis of Reliable Multicast Protocol

Reliable Multicast Protocol (RMP) is a communication protocol that provides an atomic, totally ordered, reliable multicast service on top of unreliable IP Multicasting. In this paper, we develop formal models for R.W using existing automatic verification systems, and perform verification-based analysis on the formal RMP specifications. We also use the formal models of RW specifications to generate a test suite for conformance testing of the RMP implementation. Throughout the process of RMP development, we follow an iterative, interactive approach that emphasizes concurrent and parallel progress between the implementation and verification processes. Through this approach, we incorporate formal techniques into our development process, promote a common understanding for the protocol, increase the reliability of our software, and maintain high fidelity between the specifications of RMP and its implementation.

Wu, Yunqing↗

The efficacy of periodic +Gz exposure in the prevention of bedrest induced orthostatic intolerance

What is the most efficient dosage of periodic exposure to positive 1G(z) during microgravity to maintain a functional upright position after returning to a positive 1G(z) environment? The answer has implications for the type of countermeasures astronauts will be required to perform during long term space flight. Methods: Nine males were subjected to four different positive 1G exposure protocols plus a control protocol ('zero G(z)') during four days of continuous bedrest. The four positive 1G(z) exposures consisted of periodic standing or walking, each for a total period of two or four hours. Each subject was returned for bedrest on five different occasions over a period of approximately one year to obtain data on each of the nine subjects across all four positive 1G(z) treatments and the control. A 30 min tilt test was used to measure orthostatic response during pre and post bedrest. Results: In terms of survival rate (percentage of subjects who did not faint after 30 sec of tilt), four hours of intermittent standing was the only protocol that maintained a rate comparable to pre bedrest levels (87.5 percent). Although the other three positive 1G(z) protocols performed better than the 'zero G(z) control (22.2 percent), only the four hour standing returned post bedrest survival rates to pre bedrest levels. Conclusions: The results will need to be evaluated with regards to a variety of other physiological systems which are known to decondition during microgravitry.

Ludwig, D. A.↗

A Ground Testing Program to Verify Lunar Dust-Tolerant Hardware for the Artemis Mission

In preparation for NASA’s Artemis Mission that will return humans to the surface of moon by 2024, an extensive test campaign will be undertaken to understand the effects of lunar dust contamination on equipment. Historically, early Apollo astronauts were affected by lunar dust that entered the cabin after their extravehicular activities, and subsequent missions had various cleaning protocols to reduce the impact of the contamination. The longest stays on the lunar surface were Apollo 15, 16, and 17 (just over three days), so equipment and suits were required to operate reliably for a relatively short duration. The ultimate goal of Artemis is a sustained human presence on the lunar surface, beginning with Artemis 3 which targets a six-and-a-half day surface deployment. This requires the design and testing of dust-tolerant infrastructure. Ground testing with aerosolized lunar dust simulants in a specialized chamber is an inexpensive way to verify the performance of equipment. Chambers equipped with various powder dispersers and analysis instrumentation can explore a variety of realistic scenarios relevant to lunar surface missions, from the interaction of dust with sensitive surfaces such as solar panels, textiles, radiators, and scientific equipment, to the effects of dust as it intrudes into habitable areas. These experiments require careful consideration of the expected mass concentrations, aerosolization methods, and transport properties of dust. Instruments that use light-scattering techniques to measure mass concentrations require calibration against lunar simulants for improved accuracy, and different simulants may have different calibration factors. Test facilities, laboratory setup and test methods for aerosolizing lunar simulant will be described along with relevant aerosol instruments and calibration efforts.

Benjamin J Sumlin↗