Search NASA⌕ Search

SEARCH · Search NASA

Results for “use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Optimisation of dynamic reactive power sources using mesh adaptive direct search

Dynamic reactive power sources can be used to effectively mitigate the fault-induced delayed voltage recovery and transient voltage instability issues. When many var sources need to be installed at planned locations, optimisation of their sizes is a complicated non-linear optimisation problem due to its non-convexity and the dependence of the constraint on time-series trajectories of post-fault voltages. Solving this optimal sizing problem needs to utilise both a non-linear optimisation solver and a power system differential-algebraic equation solver. This study proposes a new approach for solving this problem under both a single contingency and multiple contingencies by using the mesh adaptive direct search algorithm interfaced with a power system simulator. The proposed approach is validated by case studies on a North American Eastern Interconnection model to optimise the sizes of planned STATCOMs against critical contingencies.

Huang, Weihong↗

Overview of equilibrium reconstruction on DIII-D using new measurements from an expanded motional Stark effect diagnostic

Motional Stark effect (MSE) measurements constrain equilibrium reconstruction of DIII-D tokamak plasmas using the equilibrium code EFIT. In 2007, two new MSE arrays were brought online, bringing the system to three core arrays, two edge arrays, and 64 total channels. We present the first EFIT reconstructions using this expanded system. Safety factor and E{sub R} profiles produced by fitting to data from the two new arrays and one of the other three agree well with independent measurements. Comparison of the data from the three arrays that view the core shows that one of the older arrays is inconsistent with the other two unless the measured calibration factors for this array are adjusted. The required adjustments depend on the toroidal field and plasma current direction, and on still other uncertain factors that change as the plasma evolves. We discuss possible sources of calibration error for this array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Bremsstrahlung spectrometer using k-edge and differential filters with image plate dosimeters

A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with image plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code INTEGRATED TIGER SERIES 3.0 and the dosimeters calibrated with radioactive sources. An electron distribution with a slope temperature of 1.3 MeV is inferred from the Bremsstrahlung spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of x-ray Thomson scattering using picosecond K-α x-ray sources in the characterization of dense heated matter

Here, we present K-α x-ray Thomson scattering from shock compressed matter for use as a diagnostic in determining the temperature, density, and ionization state with picosecond resolution. The development of this source as a diagnostic as well as stringent requirements for successful K-α x-ray Thomson scattering are addressed. Here, the first elastic and inelastic scattering measurements on a medium size laser facility have been observed. We present scattering data from solid density carbon plasmas with >1X 10 5 photons in the elastic peak that validate the capability of single shot characterization of warm dense matter and the ability to use this scattering source at future free electron lasers and for fusion experiments at the National Ignition Facility (NIF), LLNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray measurements using photoconductive type-IIa and single-crystal chemical vapor deposited diamond detectors

Photoconductive detectors (PCDs) are routinely used alongside vacuum x-ray diodes (XRDs) to provide an alternative x-ray flux measurement at laser facilities such as HELEN at AWE Aldermaston, UK, and Omega at the Laboratory for Laser Energetics. To evaluate diamond PCDs as an alternative to XRD arrays, calibration measurements made at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory are used to accurately calculate the x-ray flux from a laser-heated target. This is compared to a flux measurement using the Dante XRD diagnostic. Estimates indicate that the photoinduced conductivity from measurements made at Omega are too large, and calculations using the radiometric calibrations made at the NSLS agree with this hypothesis. High-purity, single-crystal, chemical vapor deposited (CVD) diamond samples are compared to natural type-IIa PCDs and show promising high resistivity effects, the corollary of which preliminary results show is a slower response time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Use of Ionization Electron Columns for Space-Charge Compensation in High Intensity Proton Accelerators

We discuss a recent proposal to use strongly magnetized electron columns created by beam ionization of the residual gas for compensation of space charge forces of high intensity proton beams in synchrotrons and linacs. The electron columns formed by trapped ionization electrons in a longitudinal magnetic field that assures transverse distribution of electron space charge in the column is the same as in the proton beam. Electrostatic electrodes are used to control the accumulation and release of the electrons. Ions are not magnetized and drift away without affecting the compensation. Possible technical solution for the electron columns is presented. We also discuss the first numerical simulation results for space-charge compensation in the FNAL Booster and results of relevant beam studies in the Tevatron.

43 PARTICLE ACCELERATORS↗

DVCS with longitudinally polarized target using CLAS at 6 GeV

Deeply Virtual Compton Scattering (DVCS) is one of the simplest processes that can be described in terms of Generalized Parton Distributions (GPDs). The target single-spin asymmetry (target SSA) in the reaction ep-vector{yields}ep{gamma} is directly proportional to the imaginary part of the DVCS amplitude, and gives access to a combination of GPDs namely H-tilde, H, and E. This asymmetry will be measured in a dedicated experiment at Jefferson Lab using the CEBAF 6-GeV polarized electron beam, a polarized solid-state {sup 14}NH{sub 3} target, and the CEBAF Large Acceptance Spectrometer (CLAS) together with the Inner Calorimeter (IC). The expected asymmetry from leading-order calculations is in the range of 20% to 40%, depending on the kinematics and on the GPD model used. The DVCS amplitude will be mapped out in the Q{sup 2} region from 1 to 4 GeV{sup 2}, x{sub B} from 0.15 to 0.55 and -t from 0.1 to 2 GeV{sup 2} providing new constraints on the GPDs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stoichiometry optimization of homoepitaxial oxide thin films using x-ray diffraction.

Homoepitaxial SrTiO{sub 3} thin films grown by molecular beam epitaxy are analyzed using high-resolution x-ray diffraction and transmission electron microscopy. Measured 00L x-ray scans from stoichiometric and nonstoichiometric films are compared with calculations that account for the effects of film thickness, lattice parameter, fractional site occupancy, and an offset between film and substrate at the interface. It is found that thickness fringes, commonly observed around Bragg reflections even in stoichiometric homoepitaxial SrTiO{sub 3} films, arise from a film/substrate interface offset. Transmission electron microscopy studies confirm the presence of strain at those homoepitaxial interfaces that show an offset in x-ray diffraction. The consequences for stoichiometry optimization of homoepitaxial films using high-resolution x-ray diffraction and the quality of regrown oxide interfaces are discussed.

36 MATERIALS SCIENCE↗

Laboratory Astrophysics, QED, and other Measurements using the EBIT Calorimeter Spectrometer at LLNL

We have used the EBIT Calorimeter Spectrometer (ECS), a microcalorimeter instrument built by the calorimeter group at the NASA/Goddard Space Flight Center, to make a variety of measurements since its installation at Lawrence Livermore National Laboratory's EBIT facility. These include measurements of charge exchange between neutral gas and K-and L-shell ions, measurements of the X-ray transmission efficiency of optical blocking filters, high resolution measurements of transition energies for high-Z, highly charged ions, and measurements of M and L-shell emission from highly charged tungsten following on earlier measurements of L-shell gold. Our results will see application in the interpretation of the spectra from the Jovian atmosphere and of the diffuse soft X-ray background, in tests of QED, and in diagnosing inertial and magnetic confinement fusion plasmas. These measurements augment previous laboratory astrophysics, atomic physics, and calibration measurements made using earlier versions of NASA's microcalorimeter spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

43 PARTICLE ACCELERATORS↗

IMPROVED BAR IMPACT TESTS USING A PHOTONIC DOPPLER VELOCIMETER

Bar impact tests, using the techniques described elsewhere in this symposium, were used to measure compressive and tensile strengths of borosilicate glass, soda lime glass, and a glass ceramic. The glass ceramic was 25% crystalline spinel, furnished by Corning Inc. There are two measures of compressive strength: the peak stress that can be transmitted in unconfined compression, and the 'steady state' strength. For borosilicate glass and soda lime glass, these values were similar, being about 1.8 and 1.5 GPa, respectively. The glass ceramic (25% spinel) was almost 50% stronger. Tensile failure in the glass and glass ceramic takes places via surface flaws, and thus tensile strength is an extrinsic, as opposed to intrinsic property.

36 MATERIALS SCIENCE↗

Use of an autonomous sensor to evaluate the biological performance of the advanced turbine at Wanapum Dam

Hydropower is the largest renewable energy resource in the United States and the world. However, hydropower dams have adverse ecological impacts because migrating fish may be injured or killed when they pass through hydroturbines. In the Columbia and Snake River basins, dam operators and engineers are required to make those hydroelectric facilities more fish-friendly through changes in hydroturbine design and operation after fish population declines and the subsequent listing of several species of Pacific salmon under the Endangered Species Act of 1973 . Public Utility District No. 2 of Grant County, Washington, requested authorization from the Federal Energy Regulatory Commission to replace the ten turbines at Wanapum Dam with advanced hydropower turbines designed to improve survival for fish passing through the turbines while improving operation efficiency and increasing power generation. As an additional measure to the primary metric of direct injury and mortality rates of juvenile Chinook salmon using balloon tag-recapture methodology, this study used an autonomous sensor device - the Sensor Fish - to provide insight into the specific hydraulic conditions and physical stresses experienced by the fish as well as the specific causes of fish biological response. We found that the new hydroturbine blade shape and the corresponding reduction of turbulence in the advanced hydropower turbine were effective in meeting the objectives of improving fish survival while enhancing operational efficiency of the dam. The frequency of severe events based on Sensor Fish pressure and acceleration measurements showed trends similar to those of fish survival determined by the balloon tag-recapture methodology. In addition, the new turbine provided a better pressure and rate of pressure change environment for fish passage. Altogether, the Sensor Fish data indicated that the advanced hydroturbine design improved passage of juvenile salmon at Wanapum Dam.

13 HYDRO ENERGY↗

An in-vacuum x-ray diffraction microscope for use in the 0.7-2.9 keV range

A dedicated in-vacuum coherent x-ray diffraction microscope was installed at the 2-ID-B beamline of the Advanced Photon Source for use with 0.7-2.9 keV x-rays. The instrument can accommodate three common implementations of diffractive imaging; plane wave illumination; defocused-probe (Fresnel diffractive imaging) and scanning (ptychography) using either a pinhole, focused or defocused probe. The microscope design includes active feedback to limit motion of the optics with respect to the sample. Upper bounds on the relative optics-to-sample displacement have been measured to be 5.8 nm(v) and 4.4 nm(h) rms/h using capacitance micrometry and 27 nm/h using x-ray point projection imaging. The stability of the measurement platform and in-vacuum operation allows for long exposure times, high signal-to-noise and large dynamic range two-dimensional intensity measurements to be acquired. Finally, we illustrate the microscope's stability with a recent experimental result.

43 PARTICLE ACCELERATORS↗

Dynamic Composition Determination in Heterogeneous Ensembles using Angular Autocorrelation Functions as Signatures

Signatures of heterogeneous ensembles composed of multiple types of random oriented particles are represented by the angular autocorrelation functions of the systems. These signatures are retrieved by averaging oversampled angular correlation functions calculated from high throughput X-ray diffraction patterns. Using a component signature matrix, the composition of the heterogeneous system will be directly calculated from the signature of the ensemble. This is the first attempt to determine dynamic composition of a heterogeneous ensemble by fluctuation X-ray scattering using the angular autocorrelation functions as signatures.

composition determination, angular correlation fun↗

Measuring 8–250 ps short pulses using a high-speed streak camera on kilojoule, petawatt-class laser systems

Short-pulse measurements using a streak camera are sensitive to space-charge broadening, which depends on the pulse duration and shape, and on the uniformity of photocathode illumination. An anamorphic-diffuser-based beam-homogenizing system and a space-charge-broadening calibration method were developed to accurately measure short pulses using an optical streak camera. This approach provides a more-uniform streak image and enables one to characterize space-charge-induced pulse-broadening effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new method for imaging nuclear threats using cosmic ray muons

Muon tomography is a technique that uses cosmic ray muons to generate three-dimensional images of volumes using information contained in the Coulomb scattering of the muons. Advantages of this technique are the ability of cosmic rays to penetrate significant overburden and the absence of any additional dose delivered to subjects under study beyond the natural cosmic ray flux. Disadvantages include the relatively long exposure times and poor position resolution and complex algorithms needed for reconstruction. Furthermore, we demonstrate a new method for obtaining improved position resolution and statistical precision for objects with spherical symmetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring high temperature phenomena related to post-detonation using an electric arc

We report a study of materials recovered from a uranium-containing plasma generated by an electric arc. The device used to generate the arc is capable of sustaining temperatures of an eV or higher for up to 100 μs. Samples took the form of a 4 μm-thick film deposited onto 8 pairs of 17 μm-thick Cu electrodes supported on a 25 μm-thick Kapton backing and sandwiched between glass plates. Materials recovered from the glass plates and around the electrode tips after passage of an arc were characterized using scanning and transmission electron microscopy. Recovered materials included a variety of crystalline compounds (e.g., UO{sub 2}, UC{sub 2}, UCu{sub 5},) as well as mixtures of uranium and amorphous glass. Most of the materials collected on the glass plates took the form of spherules having a wide range of diameters from tens of nanometers to tens of micrometers. The composition and size of the spherules depended on location, indicating different chemical and physical environments. A theoretical analysis we have carried out suggests that the submicron spherules presumably formed by deposition during the arc discharge, while at the same time the glass plates were strongly heated due to absorption of plasma radiation mainly by islands of deposited metals (Cu, U). The surface temperature of the glass plates is expected to have risen to ∼2300 K thus producing a liquefied glass layer, likely diffusions of the deposited metals on the hot glass surface and into this layer were accompanied by chemical reactions that gave rise to the observed materials. These results, together with the compact scale and relatively low cost, suggest that the experimental technique provides a practical approach to investigate the complex physical and chemical processes that occur when actinide-containing material interacts with the environment at high temperature, for example, during fallout formation following a nuclear detonation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗