Search NASA⌕ Search

SEARCH · Search NASA

Results for “variational methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Covariant formulation of spatially non-symmetric kinetic equilibria in magnetized astrophysical plasmas

Astrophysical plasmas in the surrounding of compact objects and subject to intense gravitational and electromagnetic fields are believed to give rise to relativistic regimes. Theoretical and observational evidences suggest that magnetized plasmas of this type are collisionless and can persist for long times (e.g., with respect to a distant observer, coordinate, time), while exhibiting geometrical structures characterized by the absence of well-defined spatial symmetries. In this paper, the problem is posed whether such configurations can correspond to some kind of kinetic equilibrium. The issue is addressed from a theoretical perspective in the framework of a covariant Vlasov statistical description, which relies on the method of invariants. For this purpose, a systematic covariant variational formulation of gyrokinetic theory is developed, which holds without requiring any symmetry condition on the background fields. As a result, an asymptotic representation of the relativistic particle magnetic moment is obtained from its formal exact solution, in terms of a suitably defined invariant series expansion parameter (perturbative representation). On such a basis, it is shown that spatially non-symmetric kinetic equilibria can actually be determined, an example being provided by Gaussian-like distributions. As an application, the physical mechanisms related to the occurrence of a non-vanishing equilibrium fluid 4-flow are investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Simple Approach for Calibrating Imaging Systems with a Solid-State Sensor

Solid-state array imaging has become an indispensable tool for various modem scientific instrumentation and industrial applications. Often in experiments, use of an imaging system with linear response is very desirable. The linearity of commercial products, however, has yet to be accurately determined in order to assess their nonlinearity effects. Linearity is affected both by sensors and electronics. It is also very desirables to employ low-cost products if we can provide the performance comparable of expensive ones through calibration. Here, we present a very simple approach for approximately checking linearity of imaging systems and also a simple calibration method for precisely measuring intensity ratio or relative intensity variation. These methods can be readily implemented with existing equipment. The calibration method works well with an intermediate-grade analog sensor interfaced by a frame grabber. In our initial attempt for calibration, the nonlinearity of the camera can be reduced from about five percent to much less than one percent in standard deviation.

Leslie, Fred W.↗

Beam hardening correction using iterative total variation (ITV)-based algorithm in CBCT reconstruction

Recently, beam hardening reduction is required to produce high-quality reconstructions of X-ray cone-beam computed tomography (CBCT) system for medical applications. This paper introduces the iterative total variation (ITV) for filtered-backprojection suffering from the serious beam hardening problems. Feldkamp, Davis, and Kress (FDK) reconstruction algorithm for CBCT system is widely used reconstruction technique. FDK reconstruction algorithm could be realized by generating the weighted projection data, filtering the projection images, and back-projecting the filtered projection data into the volume. However, FDK algorithm suffers from the beam hardening artifacts by X-ray attenuation coefficients. Recently, total variation (TV) method for compressed sensing (CS) has been particularly useful in exploiting the prior knowledge of minimal variation in the X-ray attenuation characteristics across object or human body. But a practical implementation of this method still remains a challenge. The main problem is the iterative nature of solving the TV-based CS formulation, which generally requires multiple iterations of forward and backward projections of a large dataset in clinically or industrially feasible time frame. In this paper, we propose ITV method after FDK reconstruction for reducing the beam hardening artifacts. The beam hardening problems are reduced by the ITV method to promote sparsity inherent in the X-ray attenuation characteristics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terahertz Mapping of Microstructure and Thickness Variations

A noncontact method has been devised for mapping or imaging spatial variations in the thickness and microstructure of a layer of a dielectric material. The method involves (1) placement of the dielectric material on a metal substrate, (2) through-the-thickness pulse-echo measurements by use of electromagnetic waves in the terahertz frequency range with a raster scan in a plane parallel to the substrate surface that do not require coupling of any kind, and (3) appropriate processing of the digitized measurement data.

Roth, Donald J.↗

A novel method to evaluate gamma camera rotational uniformity and sensitivity variation

An alternative to the conventional method of performing the AAPM Report 52 rotational uniformity and sensitivity test has been developed. In contrast to the conventional method in which a Co-57 sheet source is fastened to the collimator, this new point-source method acquires the images intrinsically using a Tc-99m point source placed near the isocenter of gantry rotation. As with the conventional method, the point-source method acquires 5x10{sup 6} count flood images at four distinct gantry positions to calculate the maximum sensitivity variation (MSV)--a quantitative metric of rotational uniformity and sensitivity variation. The point-source method incorporates corrections for the decay of Tc-99m between acquisitions, the curvature in the image intensity due to variation in photon flux across the detector from a near-field source, and the source-to-detector distance variations between views. The raw point-source images were fitted with an analytic function in order to compute curvature- and distance-corrected images prior to analysis. Five independent MSV measurements were performed using both conventional and point-source methods on a single detector of a dual-headed SPECT system to estimate the precision of each method. The precision of the point-source method was further investigated by performing ten independent measurements of MSV on six different detectors. Correlation between the MSV calculated by the two methods was investigated by performing the test on nine different detectors using both methods. Different levels of sensitivity variations were also simulated on four detectors to generate 40 additional paired points for correlation analysis. The effect of the total image counts on the MSV estimated with the new method was evaluated by acquiring image sequences with 5x10{sup 6}, 10x10{sup 6}, and 20x10{sup 6} count images. The MSV calculated using the conventional and point-source methods exhibited a high degree of correlation and consistency with equivalence. The precision of the point-source method (0.145%) is lower than the conventional method (0.04%) but sufficient to test MSV. No statistically significant dependence of MSV with the point-source method on the total image counts over a range of (5-20)x10{sup 6} counts was observed. Curvature correction of the images prior to the generation of difference images renders images more conducive to qualitative inspection for structured, nonrandom patterns. The advantages of the new methodology are that multiple detectors of a gamma camera can be evaluated simultaneously which substantially reduces the time required for MSV testing and the reduced risk of accidental damage to the collimators and patient proximity detection system from having to mount a sheet source on each of the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 4DEnVar-based weakly coupled land data assimilation system for E3SM version 2

Abstract. A new weakly coupled land data assimilation (WCLDA) system based on the four-dimensional ensemble variational (4DEnVar) method is developed and applied to the fully coupled Energy Exascale Earth System Model version 2 (E3SMv2). The dimension-reduced projection four-dimensional variational (DRP-4DVar) method is employed to implement 4DVar using the ensemble technique instead of the adjoint technique. With an interest in providing initial conditions for decadal climate predictions, monthly mean anomalies of soil moisture and temperature from the Global Land Data Assimilation System (GLDAS) reanalysis from 1980 to 2016 are assimilated into the land component of E3SMv2 within the coupled modeling framework with a 1-month assimilation window. The coupled assimilation experiment is evaluated using multiple metrics, including the cost function, assimilation efficiency index, correlation, root-mean-square error (RMSE), and bias, and compared with a control simulation without land data assimilation. The WCLDA system yields improved simulation of soil moisture and temperature compared with the control simulation, with improvements found throughout the soil layers and in many regions of the global land. In terms of both soil moisture and temperature, the assimilation experiment outperforms the control simulation with reduced RMSE and higher temporal correlation in many regions, especially in South America, central Africa, Australia, and large parts of Eurasia. Furthermore, significant improvements are also found in reproducing the time evolution of the 2012 US Midwest drought, highlighting the crucial role of land surface in drought lifecycle. The WCLDA system is intended to be a foundational resource for research to investigate land-derived climate predictability.

58 GEOSCIENCES↗

Assimilation of AERONET and MODIS AOT Observations Using Variational and Ensemble Data Assimilation Methods and Its Impact on Aerosol Forecasting Skill

Data assimilation of Aerosol Robotic Network (AERONET) and Moderate Resolution Imaging Spectroradiometer (MODIS) aerosol optical thickness (AOT) for aerosol forecasting was tested within the Navy Aerosol Analysis Prediction System (NAAPS) framework, using variational and ensemble data assimilation methods. Navy aerosol forecasting currently makes use of a deterministic NAAPS simulation coupled to Navy Variational Data Assimilation System for aerosol optical depth, a two-dimensional variational data assimilation system, for MODIS AOT assimilation. An ensemble version of NAAPS (ENAAPS) coupled to an ensemble adjustment Kalman filter (EAKF) from the Data Assimilation Research Testbed was recently developed, allowing for a range of data assimilation and forecasting experiments to be run with deterministic NAAPS and ENAAPS. The main findings are that the EAKF, with its flow-dependent error covariances, makes better use of sparse observations such as AERONET AOT. Assimilating individual AERONET observations in the two-dimensional variational system can increase the analysis errors when observations are located in high AOT gradient regions. By including AERONET with MODIS AOT assimilation, the magnitudes of peak aerosol events (AOT> 1) were better captured with improved temporal variability, especially in India and Asia where aerosol prediction is a challenge. Assimilating AERONET AOT with MODIS had little impact on the 24 h forecast skill compared to MODIS assimilation only, but differences were found downwind of AERONET sites. The 24 h forecast skill was approximately the same for forecasts initialized with analyses from AERONET AOT assimilation alone compared to MODIS assimilation, particularly in regions where the AERONET network is dense; including the United States and Europe, indicating that AERONET could serve as a backup observation network for over-land synoptic-scale aerosol events.

Rubin, Juli I.↗

Excited states in variational Monte Carlo using a penalty method

Here, in this article, the authors present a technique using variational Monte Carlo to solve for excited states of electronic systems. This technique is based on enforcing orthogonality to lower energy states, which results in a simple variational principle for the excited states. Energy optimization is then used to solve for the excited states. This technique is applied to the well-characterized benzene molecule, in which ~10 000 parameters are optimized for the first 12 excited states. Agreement within ~0.2 eV is obtained with higher scaling coupled cluster methods; small disagreements with experiment are likely due to vibrational effects.

36 MATERIALS SCIENCE↗

Phase Contrast Imaging

All standard (medical) x-ray imaging technologies, rely primarily on the amplitude properties of the incident radiation, and do not depend on its phase. This is unchanged since the discovery by Roentgen that the intensity of an x-ray beam, as measured by the exposure on a film, was related to the relative transmission properties of an object. However, recently various imaging techniques have emerged which depend on the phase of the x-rays as well as the amplitude. Phase becomes important when the beam is coherent and the imaging system is sensitive to interference phenomena. Significant new advances have been made in coherent optic theory and techniques, which now promise phase information in medical imaging. The development of perfect crystal optics and the increasing availability of synchrotron radiation facilities have contributed to a significant increase in the application of phase based imaging in materials and life sciences. Unique source characteristics such as high intensity, monochromaticity, coherence and high collimating provide an ideal source for advanced imaging. Phase contrast imaging has been applied in both projection and computed tomography modes, and recent applications have been made in the field of medical imaging. Due to the underlying principle of X-ray detection conventional image receptors register only intensities of wave fields and not their phases. During the last decade basically five different methods were developed that translate the phase information into intensity variations. These methods are based on measuring the phase shift {phi} directly (using interference phenomena), the gradient {nabla}{sub {phi}}, or the Laplacian {nabla}{sup 2}{phi}. All three methods can be applied to polychromatic X-ray sources keeping in mind that the native source is synchrotron radiation, featuring monochromatic and reasonable coherent X-ray beams. Due to the vast difference in the coefficients that are driven absorption and phase effects (factor 1,000-10,000 in the energy range suitable for medical imaging) phase based imaging techniques are inherently extremely sensitive.

79 ASTRONOMY AND ASTROPHYSICS↗

First-principles path-integral renormalization-group method for Coulombic many-body systems

An approach for obtaining the ground state of Coulombic many-body systems is presented. This approach is based on the path-integral renormalization-group method with nonorthogonal Slater determinants, is free of the negative sign problem, and can handle higher dimensional systems with consideration of the correlation effect. Furthermore, it can be easily extended to the multicomponent quantum systems that contain more than two kinds of quantum particles. According to our results obtained with the present approach, it achieves the same accuracy as the variational Monte Carlo method with a few Slater determinants and enables us to study the entire ground state consisting of electrons and nuclei without the need to use the Born-Oppenheimer approximation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of structure parameters in strong-field tunneling ionization theory of molecules

In the strong field molecular tunneling ionization theory of Tong et al. [Phys. Rev. A 66, 033402 (2002)], the ionization rate depends on the asymptotic wave function of the molecular orbital from which the electron is removed. The orbital wave functions obtained from standard quantum chemistry packages in general are not good enough in the asymptotic region. Here we construct a one-electron model potential for several linear molecules using density functional theory. We show that the asymptotic wave function can be improved with an iteration method and after one iteration accurate asymptotic wave functions and structure parameters are determined. With the new parameters we examine the alignment-dependent tunneling ionization probabilities for several molecules and compare with other calculations and with recent measurements, including ionization from inner molecular orbitals.

74 ATOMIC AND MOLECULAR PHYSICS↗

Construction of integrable model Kohn-Sham potentials by analysis of the structure of functional derivatives

A directly approximated exchange-correlation potential should, by construction, be a functional derivative of some density functional in order to avoid unphysical results. Using generalized gradient approximations (GGAs) as an example, we show that functional derivatives of explicit density functionals have a very rigid inner structure, the knowledge of which allows one to build the entire functional derivative from a small part. Based on this analysis, we develop a method for direct construction of integrable Kohn-Sham potentials. As an illustration, we transform the model potential of van Leeuwen and Baerends (which is not a functional derivative) into a semilocal exchange potential that has a parent GGA, yields accurate energies, and is free from the artifacts inherent in existing semilocal potential approximations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Wavelet and Deep-Learning-Based Approach for Generation System Problematic Parameters Identification and Calibration

Accurate models of generation systems are critical for maintaining reliable and secure grid operations. In this paper, a novel and systematic approach is proposed to identify and calibrate the generation system problematic parameters using continuous wavelet transform (CWT) and advanced deep-learning technology. The phasor measurement unit (PMU) data are used through “event playback” to check whether the parameter calibration is required, and if yes, a group of suspicious parameters will be identified as the primary problematic parameter candidates (PPCs). These primary PPCs are randomly perturbed to generate the event playback simulation data, which are used by the CWT and convolutional neural networks (CNNs) to further narrow down the primary PPCs into a smaller set of candidates. Then, the identified candidates are perturbed again to generate massive event playback simulation data for training a parameter calibration neural network. Here, we designed a multi-output neural network structure to find the mappings between the perturbed parameters and the simulation data using both CNN and long short-term memory (LSTM) models. Finally, the well-trained and tested CNN-LSTM model is used to estimate the accurate value of the suspicious parameters with actual PMU measurements. The proposed CNN-LSTM network can accurately and reliably estimate the generation-system problematic parameters, and has better performance when compared to other machine-learning methods, such as the multilayer perceptron network and the conditional variational autoencoder method. The accuracy and effectiveness of the proposed approach have been validated through simulation and real-world data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Closed Loop Active Flow Separation Detection and Control in a Multistage Compressor

Active closed loop flow control was successfully demonstrated on a full annulus of stator vanes in a low speed axial compressor. Two independent methods of detecting separated flow conditions on the vane suction surface were developed. The first technique detects changes in static pressure along the vane suction surface, while the second method monitors variation in the potential field of the downstream rotor. Both methods may feasibly be used in future engines employing embedded flow control technology. In response to the detection of separated conditions, injection along the suction surface of each vane was used. Injected mass flow on the suction surface of stator vanes is known to reduce separation and the resulting limitation on static pressure rise due to lowered diffusion in the vane passage. A control algorithm was developed which provided a proportional response of the injected mass flow to the degree of separation, thereby minimizing the performance penalty on the compressor system.

Bright, Michelle M.↗

A wave-envelope technique for wave propagation in non-uniform ducts

The method of variation of parameters is used to analyze wave propagation in variable area, plane ducts with no mean flow. The method has an explicit representation of the fast axial variation of the acoustic modes, and numerical integration is required only for the slower axial variations of the mode amplitudes and phases. Results are presented which demonstrate the numerical advantages of the method. Comparison of the results with those of a small perturbation theory are given. The relationship between this method and the method of weighted residuals is discussed.

Kaiser, J. E.↗

Surface-induced brightness temperature variations and their effects on detecting thin cirrus clouds using IR emission channels in the 8-12 microns region

A method for detecting cirrus clouds in terms of brightness temperature differences between narrowbands at 8, 11, and 12 microns has been proposed by Ackerman et al. In this method, the variation of emissivity with wavelength for different surface targets was not taken into consideration. Based on state-of-the-art laboratory measurements of reflectance spectra of terrestrial materials by Salisbury and D'Aria, it is found that the brightness temperature differences between the 8- and 11-microns bands for soils, rocks, and minerals, and dry vegetation can vary between approximately -8 and +8 K due solely to surface emissivity variations. The large brightness temperature differences are sufficient to cause false detection of cirrus clouds from remote sensing data acquired over certain surface targets using the 8-11-12-microns method directly. It is suggested that the 8-11-12-microns method should be improved to include the surface emissivity effects. In addition, it is recommended that in the future the variation of surface emissivity with wavelength should be taken into account in algorithms for retrieving surface temperatures and low-level atmospheric temperature and water vapor profiles.

Gao, Bo-Cai↗

Development and evaluation of a new 4DEnVar-based weakly coupled ocean data assimilation system in E3SMv2

The development, implementation, and evaluation of a new weakly coupled ocean data assimilation (WCODA) system for the fully coupled Energy Exascale Earth System Model version 2 (E3SMv2) utilizing the four-dimensional ensemble variational (4DEnVar) method are presented in this study. The 4DEnVar method, based on the dimension-reduced projection four-dimensional variational (DRP-4DVar) approach, replaces the adjoint model with the ensemble technique, thereby reducing computational demands. Monthly mean ocean temperature and salinity data from the EN4.2.1 reanalysis are integrated into the ocean component of E3SMv2 from 1950 to 2021 with the goal of providing realistic initial conditions for decadal predictions and predictability studies. The performance of the WCODA system is assessed using various metrics, including the reduction rate of the cost function, root mean square error (RMSE) differences, correlation differences, and model biases. Results indicate that the WCODA system effectively assimilates the reanalysis data into the climate model, consistently achieving negative reduction rates of the cost function and notable improvements in RMSE and correlation across various ocean layers and regions. Significant enhancements are observed in the upper ocean layers across the majority of global ocean regions, particularly in the north Atlantic, north Pacific, and Indian Ocean. Model biases in sea surface temperature and salinity are also substantially reduced. For sea surface temperature, cold biases in the north Pacific and north Atlantic are diminished by about 1–2 °C, and warm biases in the Southern Ocean are corrected by approximately 1.5–2.5 °C. In terms of salinity, improvements are observed with bias reductions of about 0.5–1 psu in the north Atlantic and north Pacific and up to 1.5 psu in parts of the Southern Ocean. The ultimate goal of the WCODA system is to advance the predictive capabilities of E3SM for subseasonal to decadal climate predictions, thereby supporting research on strategic energy-sector policies and planning.

54 ENVIRONMENTAL SCIENCES↗

Elastic Buckling of Laminated Plates Under Varying Axial Stresses

The elastic buckling load of simply supported rectangular composite plates subjected to a second degree parabolic variation of axial stresses in the longitudinal direction is calculated using analytical methods. The variation of axial stresses is equilibrated by nonuniform shear stresses along the plate edges and transverse normal stresses. Numerical results are reported for three different cases: (1) orthotropic plates, (2) symmetrically laminated plates with multiple generally orthotropic layers exhibiting coupling between normal moments and twist, and twisting moment and normal curvatures, and (3) unsymmetrically laminated plates. Rayleigh-Ritz method is used to calculate the buckling load. An approximate solution using "reduced bending stiffness" is adopted for unsymmetrically laminated plates. The influence of the aspect ratio is examined, and the results are compared with plates subjected to uniform axial stresses.

Badir, A.↗