Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage regulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Advanced Power Regulator Developed for Spacecraft

The majority of new satellites generate electrical power using photovoltaic solar arrays and store energy in batteries for use during eclipse periods. Careful regulation of battery charging during insolation can greatly increase the expected lifetime of the satellite. The battery charge regulator is usually custom designed for each satellite and its specific mission. Economic competition in the small satellite market requires battery charge regulators that are lightweight, efficient, inexpensive, and modular enough to be used in a wide variety of satellites. A new battery charge regulator topology has been developed at the NASA Lewis Research Center to address these needs. The new regulator topology uses industry-standard dc-dc converters and a unique interconnection to provide size, weight, efficiency, fault tolerance, and modularity benefits over existing systems. A transformer-isolated buck converter is connected such that the high input line is connected in series with the output. This "bypass connection" biases the converter's output onto the solar array voltage. Because of this biasing, the converter only processes the fraction of power necessary to charge the battery above the solar array voltage. Likewise, the same converter hookup can be used to regulate the battery output to the spacecraft power bus with similar fractional power processing.

Source record↗

Self-starting circuit for switching regulators

Schematic is provided on a self-starting circuit for a switching regulator which uses a logic circuit to sense a change in output voltage and provides a correction signal for dc power sources. With this device, the total power consumed by the logic circuitry is held to a minimum, and the circuit receives the optimum regulated supply power.

Schraut, E. H.↗

A Call To Action To Engage The Community To Meet The Challenges That Must Be Tackled To Make Electrified Aircraft Propulsion Real

Technology risk reduction is essential, as it is necessary to demonstrate the potential of Electrified Aircraft Propulsion (EAP). However, more is needed for implementation. The industry is leading EAP by developing a diverse community of novel vehicles from short-haul, small, urban-focused electric vertical takeoff and landing (eVTOL) to regional air mobility (RAM) and hybrid-electric, single-aisle transport category airplanes. There are a variety of novel EAP technologies for each of these novel vehicles. And the industry is not only looking at novel technology to advance the state of the art. Instead, the industry is looking to certify these novel aircraft through their regulatory authorities, such as the US Federal Aviation Administration (FAA), the European Union Aviation Safety Authority (EASA), Transport Canada Civil Aviation (TCCA), and Brazil’s Agência Nacional de Aviação Civil (National Civil Aviation Agency, ANAC), as well as other regulatory authorities. The NASA Electrified Powertrain Flight Demonstration (EPFD) project has partnered with two industry partners to advance integrated MW-class powertrain system technology demonstration that includes an assessment of their regulatory and standards gaps in their technology. The EPFD has conducted a generic regulatory gap analysis of hybrid electric engines that aligns with the industry partners’ efforts. The EPFD regulations and standards team is integrated into the industry standards community. The international industry standards community is wrestling with critical key challenges to certification. While some certification elements are proprietary, several technology elements cut across company propriety in aircraft engines (US 14 CFR Part 33 and EASA CS-E, regulations that only reflect reciprocating and turbine engines). The approach that several of these regulatory authorities have taken is to collaborate to address their challenges. The Certification Management Team (CMT) consists of the EASA, FAA, TCCA, and ANAC, and they have begun to address common questions, such as the Loss of Power Control (LOPC) for electric engines. They have reached out to the standards community to seek answers. The industry standards development organizations (SDO) have also looked ahead to address current regulations and standards gaps. The ASTM has built key committees in its ASTM F44 General Aviation Committee and F39 Aircraft Systems Committee. The SAE has established the E-40 Electric Propulsion and AE-10 High Voltage committees.

Standards↗

Understanding the Value of Energy Storage for Power System Reliability and Resilience Applications

Abstract Purpose of Review The need for energy storage in the electrical grid has grown in recent years in response to a reduced reliance on fossil fuel baseload power, added intermittent renewable investment, and expanded adoption of distributed energy resources. While the methods and models for valuing storage use cases have advanced significantly in recent years, the value of enhanced resilience remains an open research question. Recent Findings The findings of the recent research indicate that energy storage provides significant value to the grid, with median benefit values for specific use cases ranging from under $10/kW-year for voltage support to roughly $100/kW-year for capacity and frequency regulation services. While the value of lost load is used widely to estimate the benefits of mitigating short-duration outages, reaching as high as $719/kilowatt-year, there is no consensus when it comes to monetizing the value of improving grid resilience. Summary This paper presents a use case taxonomy for energy storage and uses the taxonomy to conduct a meta-analysis of an extensive set of energy storage valuation studies. It reviews several approaches for monetizing reliability and resiliency services and presents a proposed approach for valuing resiliency for energy storage investments.

25 ENERGY STORAGE↗

Redox flow cell energy storage systems

The redox flow cell energy storage system being developed by NASA for use in remote power systems and distributed storage installations for electric utilities is presented. The system under consideration is an electrochemical storage device which utilizes the oxidation and reduction of two fully soluble redox couples (acidified chloride solutions of chromium and iron) as active electrode materials separated by a highly selective ion exchange membrane. The reactants are contained in large storage tanks and pumped through a stack of redox flow cells where the electrochemical reactions take place at porous carbon felt electrodes. Redox equipment has allowed the incorporation of state of charge readout, stack voltage control and system capacity maintenance (rebalance) devices to regulate cells in a stack jointly. A 200 W, 12 V system with a capacity of about 400 Wh has been constructed, and a 2 kW, 10kWh system is planned.

Thaller, L. H.↗

DC-DC power converter research for Orbiter/Station power exchange

This project was to produce innovative DC-DC power converter concepts which are appropriate for the power exchange between the Orbiter and the Space Station Freedom (SSF). The new converters must interface three regulated power buses on SSF, which are at different voltages, with three fuel cell power buses on the Orbiter which can be at different voltages and should be tracked independently. Power exchange is to be bi-directional between the SSF and the Orbiter. The new converters must satisfy the above operational requirements with better weight, volume, efficiency, and reliability than is available from the present conventional technology. Two families of zero current DC-DC converters were developed and successfully adapted to this application. Most of the converters developed are new and are presented.

Ehsani, M.↗

The effects of outgassing materials on voltage breakdown

We will start by reviewing some of the basic equations which regulate outgassing and show their dependency on temperature and thickness. Then we will draw an analogy between mass transfer or outgassing and radiant heat transfer, and show how we utilize a computer program initially written for radiant heat transfer to determine the condensation rate caused by mass transfer.

J. F. Scannapieco↗

Regulated high efficiency, lightweight capacitor-diode multiplier dc to dc converter

A voltage multiplier having a capacitor-diode voltage multiplying network is disclosed which is fed with voltage pulses from a dc source through a first switching means. Pulses of a second polarity are also supplied through a second switching means to the input of the capacitor-diode voltage multiplier from a second dc source whose voltage is adjustable to change the voltage of the pulses of second polarity. The switching means are alternately rendered conducting by signals from a control circuit. The second dc source may be controlled by a voltage comparator which compares the output voltage of the capacitor-diode voltage multiplier to the reference source.

Harrigill, W. T., Jr.↗

Introduction to Grid Forming Inverters: A Key to Transforming our Power Grid [Slides]

A grid-forming (GFM) inverter-based resource (IBR) controls maintain an internal voltage phasor that is constant or nearly constant in the sub-transient to transient time frame. This definition means that the GFM IBR will nearly immediately respond to changes in the external system and attempt to maintain IBR control during challenging network conditions to maintain grid stability. In GFM IBR, the voltage phasor is controlled to maintain synchronism with other devices in the grid while regulating the active and reactive power appropriately to support the grid. This contrasts with conventional GFL IBR controls wherein immediately after a disturbance (0-5 cycles), within the normal operating range of voltage, the output current phasor magnitude and angle remain unchanged, and the current phasor begins changing only within the transient time frame (tens of cycles) to strictly control the active and reactive power being injected into the network. This presentation gives an introduction to GFM IBR and presents the current state of the art in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Power Conditioning System

The second portion of the advanced power conditioning system development program is reported. Five 100-watt parallel power stages with majority-vote-logic feedback-regulator were breadboarded and tested to the design goals. The input voltage range was 22.1 to 57.4 volts at loads from zero to 500 watts. The maximum input ripple current was 200 mA pk-pk (not including spikes) at 511 watts load; the output voltage was 56V dc with a maximum change of 0.89 volts for all variations of line, load, and temperature; the maximum output ripple was 320 mV pk-pk at 512 watts load (dependent on filter capacitance value); the maximum efficiency was 93.9% at 212 watts and 50V dc input; the minimum efficiency was 87.2% at 80-watt load and 50V dc input; the efficiency was above 90% from 102 watts to 372 watts; the maximum excursion for an 80-watt load change was 2.1 volts with a recovery time of 7 milliseconds; and the unit performed within regulation limits from -20 C to +85 C. During the test sequence, margin tests and failure mode tests were run with no resulting degradation in performance.

Johnson, N. L.↗

Parametric Comparative Analysis between Virtual Synchronous Generator and Droop-based Inertia for Inverter-Based Microgrids

This paper presents a parametric comparative analysis between the virtual synchronous generator (VSG) method and the droop control method to emulate inertia in the voltage-source inverter (VSI). Droop controllers are commonly used to regulate sharing power in microgrids and distribute power generation proportionally among VSI’s depending on their rated power. Additionally, VSG has been used to regulate the Rate-of-Change-of-Frequency (RoCoF) of the microgrid using virtual inertia. Although both methods can be used to regulate the frequency variation, the influence of each method on the closed loop eigenvalues is not the same. In this work, the transient response of the frequency is analyzed for each method to determine their advantages and disadvantages regarding frequency regulation in microgrid applications. The results were verified by conducting experimental trials using VSI’s. These experiments demonstrated that VSG is more suitable for regulating RoCoF and frequency nadir than droop controllers since it provides inertial support and improves frequency response.

Campo-Ossa, Daniel D.↗

Low-noise current regulator

Modification of conventional regulator minimizes current drift. Current to be regulated flows through sensing resistor in series with load, producing voltage that is fed into operational amplifier. Other input into amplifier is reference voltage from Zener diode network.

Bunn, J.↗

Stable low noise voltage source

Hum and noise on power sources can have a significant effect on system noise. Filtering to achieve low hum and noise is accomplished at low current levels. The diode regulator circuit is described which is ideal for this type of filtering. Hum and noise rejection is achieved with good output voltage stability in a small, low-cost, reliable circuit.

Lutes, G. F.↗

Self-regulating control of parasitic loads in a fuel cell power system

A fuel cell power system comprises an internal or self-regulating control of a system or device requiring a parasitic load. The internal or self-regulating control utilizes certain components and an interconnection scheme to produce a desirable, variable voltage potential (i.e., power) to a system or device requiring parasitic load in response to varying operating conditions or requirements of an external load that is connected to a primary fuel cell stack of the system. Other embodiments comprise a method of designing such a self-regulated control scheme and a method of operating such a fuel cell power system.

Vasquez, Arturo↗

Direct current ballast circuit for metal halide lamp

A direct current ballast circuit for a two electrode metal halide lamp is described. Said direct current ballast circuit includes a low voltage DC input and a high frequency power amplifier and power transformer for developing a high voltage output. The output voltage is rectified by diodes and filtered by inductor and capacitor to provide a regulated DC output through commutating diodes to one terminal of the lamp at the output terminal. A feedback path from the output of the filter capacitor through the bias resistor to power the high frequency circuit which includes the power amplifier and the power transformer for sustaining circuit operations during low voltage transients on the input DC supply is described. A current sensor connected to the output of the lamp through terminal for stabilizing lamp current following breakdown of the lamp is described.

Lutus, P.↗

An automated and portable method for selecting an optimal GPU frequency

Power consumption poses a significant challenge in current and emerging graphics processing unit (GPU) enabled high-performance computing systems. In modern GPUs, dynamic voltage frequency scaling (DVFS) appears to be a reliable control to regulate power consumption and performance. However, the DVFS design space is large - hence, brute-force approaches are infeasible to select the optimal frequency. Furthermore, no single frequency can be universally optimal for applications with varying computational intensities. Thus, the application's complexity and the availability of a wide range of frequency settings are a challenge in selecting the optimal frequency configuration for a given GPU workload. To that end, this paper proposes a systematic approach that consists of three steps. The feature characterization study identifies the fine-grain GPU utilization metrics that influence the power consumption and execution time of a given workload. To understand the performance, power, and energy consumption behaviors of a workload across GPU's DVFS design space, we derived analytical power and performance models using the identified fine-grain features. Here, it is shown that the same set of GPU utilization metrics can estimate both the power consumption and execution time while being agnostic of changes to frequency and input sizes. Applying a power control with the single objective of reducing power may cause performance degradation, leading to more energy consumption. A multi-objective approach is proposed to select the optimal GPU DVFS configuration for a workload that reduces power consumption with negligible degradation in performance. The evaluation was conducted using SPEC ACCEL benchmarks and three real applications - NAMD LAMMPS, and LSTM on NVIDIA GV100, GA100, and AMD MI210 GPUs. On average, real applications showed 29.6% energy savings with a performance loss of 5.2% on GA100 and 22.6% energy savings with a performance loss of 4.7% on GV100. Moreover, the proposed models are portable to real applications, GPU architectures, and vendors, and require metric collection at only the default frequency rather than all supported DVFS configurations. Additionally, we conducted a comparison between our models and the GPU assembly instructions (PTX)-based static models. The results revealed a significant reduction in the average error rates, with a decrease from 19.7% to 3.1% for power models and from 29.4% to 5.2% for performance models.

97 MATHEMATICS AND COMPUTING↗

Modular Plasma Microreactor for Intensified Hydrogen Peroxide Production

Sustainable and decentralized manufacturing of hydrogen peroxide (H 2 O 2 ) has been extensively sought to replace the energy- and waste-intensive anthraquinone process. We introduce a helical biphasic microreactor in a coaxial dielectric barrier discharge (DBD) configuration as a modular, adaptable, and scalable intensified unit for H 2 O 2 production. Geometric and operating parameters such as electrode length, applied voltage, and gas and liquid flow rates can be tuned to regulate the residence time, delivered power, and gas–liquid interfacial area. In turn, these affect the key output parameters, i.e., H 2 O 2 concentration, production rate, and energy yield. We found a direct correlation between the H 2 O 2 production rate and the product of the interfacial area and residence time in the plasma region. We investigated the H 2 O 2 formation pathways using DMSO as an ·OH radical scavenger and found that H 2 O 2 forms by the dissolution of gaseous H 2 O 2 at low interfacial areas and is enhanced probably due to the interfacial recombination of ·OH radicals at a large gas–liquid interfacial area. The reactor temperature can also be externally controlled to intensify the production rate and energy yield of H 2 O 2 . Concentrations of up to 33 mM can be attained with a small footprint reactor that features a maximum energy yield of 4 g kWh –1 . Here, the plasma microreactor could epitomize a powerful process intensification tool for sustainable and distributed chemical manufacturing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗