Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

ATLAS: Story Maps for Communicating Groundwater Cleanup Status - 18510

The U.S. Department of Energy (DOE) manages one of the largest groundwater cleanup efforts in the world in terms of the number of plumes, diversity of contaminants, volume of affected groundwater, and diversity of hydrogeologic settings. The DOE Office of Environmental Management (EM) has been collecting site-specific data on plume sizes, remedial approaches, exit strategies, long-term stewardship requirements, and regulatory drivers at all DOE sites, and summarizing them in a single document to communicate high-level information on groundwater contamination and cleanup status to DOE managers. Recently, EM has sponsored an effort to transfer the document-based information to an online resource for collating information on groundwater plumes that is easily accessible by interested parties. Specifically, Web GIS story maps have been developed to provide a robust geospatial visualization of plumes at DOE sites using an intuitive interface that allows users to explore plume maps, explanatory text, photographs, and video provided within the story maps. This collection of story maps is called ATLAS (Assembly of Tools for Learning Actions and Status), and not only communicates groundwater plume data for each individual site, but also summarizes pertinent metrics across all EM sites. With ATLAS, sites with similar settings, contamination, or remedial approaches can be easily identified, facilitating effective communication among DOE sites and sharing of individual successes and lessons learned. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The BioPAX community standard for pathway

Biological Pathway Exchange (BioPAX) is a standard language to represent biological pathways at the molecular and cellular level and to facilitate the exchange of pathway data. The rapid growth of the volume of pathway data has spurred the development of databases and computational tools to aid interpretation; however, use of these data is hampered by the current fragmentation of pathway information across many databases with incompatible formats. BioPAX, which was created through a community process, solves this problem by making pathway data substantially easier to collect, index, interpret and share. BioPAX can represent metabolic and signaling pathways, molecular and genetic interactions and gene regulation networks. Using BioPAX, millions of interactions, organized into thousands of pathways, from many organisms are available from a growing number of databases. This large amount of pathway data in a computable form will support visualization, analysis and biological discovery.

59 BASIC BIOLOGICAL SCIENCES↗

Computer-aided pulmonary image analysis in small animal models

Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next. The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.

60 APPLIED LIFE SCIENCES↗

Learning to Predict Crystal Plasticity at the Nanoscale: Deep Residual Networks and Size Effects in Uniaxial Compression Discrete Dislocation Simulations

The density and configurational changes of crystal dislocations during plastic deformation influence the mechanical properties of materials. These influences have become clearest in nanoscale experiments, in terms of strength, hardness and work hardening size effects in small volumes. The mechanical characterization of a model crystal may be cast as an inverse problem of deducing the defect population characteristics (density, correlations) in small volumes from the mechanical behavior. In this work, we demonstrate how a deep residual network can be used to deduce the dislocation characteristics of a sample of interest using only its surface strain profiles at small deformations, and then statistically predict the mechanical response of size-affected samples at larger deformations. As a testbed of our approach, we utilize high-throughput discrete dislocation simulations for systems of widths that range from nano- to micro- meters. We show that the proposed deep learning model significantly outperforms a traditional machine learning model, as well as accurately produces statistical predictions of the size effects in samples of various widths. By visualizing the filters in convolutional layers and saliency maps, we find that the proposed model is able to learn the significant features of sample strain profiles.

36 MATERIALS SCIENCE↗

Determining Remaining Useful Life of Aging Cables in Nuclear Power Plants – Interim Study FY13

The most important criterion for cable performance is its ability to withstand a design-basis accident. With nearly 1000 km of power, control, instrumentation, and other cables typically found in an NPP, it would be a significant undertaking to inspect all of the cables. Degradation of the cable jacket, electrical insulation, and other cable components is a key issue that is likely to affect the ability of the currently installed cables to operate safely and reliably for another 20 to 40 years beyond the initial operating life. The development of one or more nondestructive evaluation (NDE) techniques and supporting models that could assist in determining the remaining life expectancy of cables or their current degradation state would be of significant interest. The ability to nondestructively determine material and electrical properties of cable jackets and insulation without disturbing the cables or connections has been deemed essential. Currently, the only technique accepted by industry to measure cable elasticity (the gold standard for determining cable insulation degradation) is the indentation measurement. All other NDE techniques are used to find flaws in the cable and do not provide information to determine the current health or life expectancy. There is no single NDE technique that can satisfy all of the requirements needed for making a life-expectancy determination, but a wide range of methods have been evaluated for use in NPPs as part of a continuous evaluation program. The commonly used methods are indentation and visual inspection, but these are only suitable for easily accessible cables. Several NDE methodologies using electrical techniques are in use today for flaw detection but there are none that can predict the life of a cable. There are, however, several physical and chemical ptoperty changes in cable insulation as a result of thermal and radiation damage. In principle, these properties may be targets for advanced NDE methods to provide early warning of aging and degradation. Examples of such key indicators include changes in chemical structure, mechanical modulus, and dielectric permittivity. While some of these indicators are the basis of currently used technologies, there is a need to increase the volume of cable that may be inspected with a single measurement, and if possible, to develop techniques for in-situ inspection (i.e., while the cable is in operation). This is the focus of the present report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-C-17A-05: Quantification of Intra-Fraction Motion of Breast Tumors Using Cine-MRI

Purpose: Magnetic resonance imaging (MRI) enables direct characterization of intra-fraction motion ofbreast tumors, due to high softtissue contrast and geometric accuracy. The purpose is to analyzethis motion in early-stage breast-cancer patients using pre-operative supine cine-MRI. Methods: MRI was performed in 12 female early-stage breast-cancer patients on a 1.5-T Ingenia (Philips)wide-bore scanner in supine radiotherapy (RT) position, prior to breast-conserving surgery. Twotwodimensional (2D) T2-weighted balanced fast-field echo (cine-MRI) sequences were added tothe RT protocol, oriented through the tumor. They were alternately acquired in the transverse andsagittal planes, every 0.3 s during 1 min. A radiation oncologist delineated gross target volumes(GTVs) on 3D contrast-enhanced MRI. Clinical target volumes (CTV = GTV + 15 mm isotropic)were generated and transferred onto the fifth time-slice of the time-series, to which subsequents lices were registered using a non-rigid Bspline algorithm; delineations were transformed accordingly. To evaluate intra-fraction CTV motion, deformation fields between the transformed delineations were derived to acquire the distance ensuring 95% surface coverage during scanning(P95%), for all in-plane directions: anteriorposterior (AP), left-right (LR), and caudal-cranial(CC). Information on LR was derived from transverse scans, CC from sagittal scans, AP fromboth sets. Results: Time-series with registration errors - induced by motion artifacts - were excluded by visual inspection. For our analysis, 11 transverse, and 8 sagittal time-series were taken into account. Themedian P95% calculated in AP (19 series), CC (8), and LR (11) was 1.8 mm (range: 0.9–4.8), 1.7mm (0.8–3.6), and 1.0 mm (0.6–3.5), respectively. Conclusion: Intra-fraction motion analysis of breast tumors was achieved using cine-MRI. These first results show that in supine RT position, motion amplitudes are limited. This information can be used for adaptive RT planning, and to develop preoperative partial-breast RT strategies, such asablative RT for early-stage breast-cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-279: Realization of Three-Dimensional Conformal Dose Planning in Prostate Brachytherapy

Purpose: Successful clinical treatment in prostate brachytherapy is largely dependent on the effectiveness of pre-surgery dose planning. Conventional dose planning method could hardly arrive at a satisfy result. In this abstract, a three-dimensional conformal localized dose planning method is put forward to ensure the accuracy and effectiveness of pre-implantation dose planning. Methods: Using Monte Carlo method, the pre-calculated 3-D dose map for single source is obtained. As for multiple seeds dose distribution, the maps are combined linearly to acquire the 3-D distribution. The 3-D dose distribution is exhibited in the form of isodose surface together with reconstructed 3-D organs group real-timely. Then it is possible to observe the dose exposure to target volume and normal tissues intuitively, thus achieving maximum dose irradiation to treatment target and minimum healthy tissues damage. In addition, the exfoliation display of different isodose surfaces can be realized applying multi-values contour extraction algorithm based on voxels. The needles could be displayed in the system by tracking the position of the implanted seeds in real time to conduct block research in optimizing insertion trajectory. Results: This study extends dose planning from two-dimensional to three-dimensional, realizing the three-dimensional conformal irradiation, which could eliminate the limitations of 2-D images and two-dimensional dose planning. A software platform is developed using VC++ and Visualization Toolkit (VTK) to perform dose planning. The 3-D model reconstruction time is within three seconds (on a Intel Core i5 PC). Block research could be conducted to avoid inaccurate insertion into sensitive organs or internal obstructions. Experiments on eight prostate cancer cases prove that this study could make the dose planning results more reasonable. Conclusion: The three-dimensional conformal dose planning method could improve the rationality of dose planning by safely reducing the large target margin and avoiding dose dead zones for prostate cancer treatment. 1) National Natural Science Foundation of People's Republic of China (No. 51175373); 2) New Century Educational Talents Plan of Chinese Education Ministry (NCET-10-0625); 3) Scientific and Technological Major Project, Tianjin (No. 12ZCDZSY10600)

60 APPLIED LIFE SCIENCES↗

SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy

Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared to rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.

60 APPLIED LIFE SCIENCES↗

Transuranic (TRU) Waste Repackaging at the Nevada Test Site

This paper describes the activities required to modify a facility and the process of characterizing, repackaging, and preparing for shipment the Nevada Test Site’s (NTS) legacy transuranic (TRU) waste in 58 oversize boxes (OSB). The waste, generated at other U.S. Department of Energy (DOE) sites and shipped to the NTS between 1974 and 1990, requires size-reduction for off-site shipment and disposal. The waste processing approach was tailored to reduce the volume of TRU waste by employing decontamination and non-destructive assay. As a result, the low-level waste (LLW) generated by this process was packaged, with minimal size reduction, in large sea-land containers for disposal at the NTS Area 5 Radioactive Waste Management Complex (RWMC). The remaining TRU waste was repackaged and sent to the Idaho National Laboratory Consolidation Site for additional characterization in preparation for disposal at the Waste Isolation Pilot Plant (WIPP), near Carlsbad, New Mexico. The DOE National Nuclear Security Administration Nevada Site Office and the NTS Management and Operating (M&O) contractor, NSTec, successfully partnered to modify and upgrade an existing facility, the Visual Examination and Repackaging Building (VERB). The VERB modifications, including a new ventilation system and modified containment structure, required an approved Preliminary Documented Safety Analysis prior to project procurement and construction. Upgrade of the VERB from a radiological facility to a Hazard Category 3 Nuclear Facility required new rigor in the design and construction areas and was executed on an aggressive schedule. The facility Documented Safety Analysis required that OSBs be vented prior to introduction into the VERB. Box venting was safely completed after developing and implementing two types of custom venting systems for the heavy gauge box construction. A remotely operated punching process was used on boxes with wall thickness of up to 3.05 mm (0.120 in) to insert aluminum bronze filters and sample ports to prevent sparking during penetration. A remotely operated cold-drilling process with self-drilling, self-tapping titanium coated spark-resistant filters was used for boxes with wall thickness of up to 6.35 mm (0.25 in). The box headspace was sampled for the presence of flammable gases. To further accelerate the project schedule, an innovative treatment process was used. Several of the OSBs were re-assayed and determined to be mixed low-level waste (MLLW) which allowed treatment, followed by disposal in the Mixed Waste Disposal Unit at the NTS Area 5 Radioactive Waste Management Complex (RWMC). The MLLW boxes were certified using real-time radiography and overpacked into custom-built polyethylene-lined macroencapsulation containers. The polyethylene-lined lid was welded to the poly-lined box using automatically controlled resistance heating through embedded wiring in the lid. The work was performed under the existing Documented Safety Analysis since plastic welding is accomplished at low temperature and does not introduce the risks of other macroencapsulation processes, such as welding stainless steel containers. The macroencapsulation process for MLLW not only accelerated the schedule by reducing the number of boxes requiring size reduction, but it also resulted in significantly improved safety with as low as reasonable achievable levels of exposure to workers plus reduced cost by eliminating the need to perform repackaging in the VERB.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crystallographic Insight of Reduced Lattice Volume Expansion in Mesoporous Cu 2+ -Doped TiNb 2 O 7 Microspheres during Li + Insertion

TiNb 2 O 7 represents a promising anode material for lithium-ion batteries (LIBs), but its practical applications are currently hampered by the non-negligible volumetric expansion and contraction during the charge/discharge process and the sluggish ion/electron kinetics. Here a combination technique is reported by systematically optimizing the porous and spherical morphology, crystal structure, and surface decoration of mesoporous Cu 2+ -doped TiNb 2 O 7 microspheres to enhance the electrochemical Li + storage performance and stability simultaneously. The Cu 2+ dopants preferentially replace Ti 4+ in crystal lattices, which decreases the Li + diffusion barrier and increases the electronic conductivity, as confirmed by density functional theory (DFT) calculation and demonstrated by diverse electrochemical characterizations. The successful Cu 2+ doping significantly reduces the lattice expansion coefficient from 7.26% to 4.61% after Li + insertion along the b-axis of TiNb 2 O 7 , as visualized from in situ and ex situ XRD analysis. The optimal 5% Cu 2+ -doped TiNb 2 O 7 with surface coating of N-doped carbon exhibits significantly enhanced specific capacity and rate and cyclic performances in both half- and full-cell configurations, demonstrating an excellent electrochemical behavior for fast-charging LIB applications.

36 MATERIALS SCIENCE↗

Implementation of Feedback-Guided Voluntary Breath-Hold Gating for Cone Beam CT-Based Stereotactic Body Radiotherapy

Purpose: To analyze tumor position reproducibility of feedback-guided voluntary deep inspiration breath-hold (FGBH) gating for cone beam computed tomography (CBCT)-based stereotactic body radiotherapy (SBRT). Methods and materials: Thirteen early-stage lung cancer patients eligible for SBRT with tumor motion of >1cm were evaluated for FGBH-gated treatment. Multiple FGBH CTs were acquired at simulation, and single FGBH CBCTs were also acquired prior to each treatment. Simulation CTs and treatment CBCTs were analyzed to quantify reproducibility of tumor positions during FGBH. Benefits of FGBH gating compared to treatment during free breathing, as well treatment with gating at exhalation, were examined for lung sparing, motion margins, and reproducibility of gross tumor volume (GTV) position relative to nonmoving anatomy. Results: FGBH increased total lung volumes by 1.5 times compared to free breathing, resulting in a proportional drop in total lung volume receiving 10 Gy or more. Intra- and inter-FGBH reproducibility of GTV centroid positions at simulation were 1.0 {+-} 0.5 mm, 1.3 {+-} 1.0 mm, and 0.6 {+-} 0.4 mm in the anterior-posterior (AP), superior-inferior (SI), and left-right lateral (LR) directions, respectively, compared to more than 1 cm of tumor motion at free breathing. During treatment, inter-FGBH reproducibility of the GTV centroid with respect to bony anatomy was 1.2 {+-} 0.7 mm, 1.5 {+-} 0.8 mm, and 1.0 {+-} 0.4 mm in the AP, SI, and LR directions. In addition, the quality of CBCTs was improved due to elimination of motion artifacts, making this technique attractive for poorly visualized tumors, even with small motion. Conclusions: The extent of tumor motion at normal respiration does not influence the reproducibility of the tumor position under breath hold conditions. FGBH-gated SBRT with CBCT can improve the reproducibility of GTV centroids, reduce required margins, and minimize dose to normal tissues in the treatment of mobile tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanochemically responsive polymer enables shockwave visualization

Abstract Understanding the physical and chemical response of materials to impulsive deformation is crucial for applications ranging from soft robotic locomotion to space exploration to seismology. However, investigating material properties at extreme strain rates remains challenging due to temporal and spatial resolution limitations. Combining high-strain-rate testing with mechanochemistry encodes the molecular-level deformation within the material itself, thus enabling the direct quantification of the material response. Here, we demonstrate a mechanophore-functionalized block copolymer that self-reports energy dissipation mechanisms, such as bond rupture and acoustic wave dissipation, in response to high-strain-rate impacts. A microprojectile accelerated towards the polymer permanently deforms the material at a shallow depth. At intersonic velocities, the polymer reports significant subsurface energy absorption due to shockwave attenuation, a mechanism traditionally considered negligible compared to plasticity and not well explored in polymers. The acoustic wave velocity of the material is directly recovered from the mechanochemically-activated subsurface volume recorded in the material, which is validated by simulations, theory, and acoustic measurements. This integration of mechanochemistry with microballistic testing enables characterization of high-strain-rate mechanical properties and elucidates important insights applicable to nanomaterials, particle-reinforced composites, and biocompatible polymers.

Science & Technology - Other Topics↗

Constrained CVT meshes and a comparison of triangular mesh generators

Mesh generation in regions in Euclidean space is a central task in computational science, and especially for commonly used numerical methods for the solution of partial differential equations, e.g., finite element and finite volume methods. We focus on the uniform Delaunay triangulation of planar regions and, in particular, on how one selects the positions of the vertices of the triangulation. We discuss a recently developed method, based on the centroidal Voronoi tessellation (CVT) concept, for effecting such triangulations and present two algorithms, including one new one, for CVT-based grid generation. We also compare several methods, including CVT-based methods, for triangulating planar domains. To this end, we define several quantitative measures of the quality of uniform grids. We then generate triangulations of several planar regions, including some having complexities that are representative of what one may encounter in practice. We subject the resulting grids to visual and quantitative comparisons and conclude that all the methods considered produce high-quality uniform grids and that the CVT-based grids are at least as good as any of the others.

97 MATHEMATICS AND COMPUTING↗

A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion

Purpose: Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors’ proposed approach. Methods: A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. Results: The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors’ proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. Conclusions: The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

60 APPLIED LIFE SCIENCES↗

Browsing a wealth of millimeter-wavelength doppler spectra data

The ARM Climate Research Facility has collected an extensive archive of vertically pointing millimeter wavelength Doppler radar spectra at both 35 and 95 GHz. These data are a rich potential source of detailed microphysical and dynamical cloud and precipitation information. The recording of spectra, which is ongoing, began at the Southern Great Plains site in September of 2003, at the North Slope of Alaska site in April 2004, and at Tropical Western Pacific sites in 2006. Spectra are also being collected during ARM Mobile Facility deployments. The data’s temporal resolution is as high as two seconds, at height intervals of 45 to 90 m. However, the sheer volume of available data can be somewhat daunting to access and search for specific features of interest. Here we present a user interface for spectra browsing, which allows the user to view time-height images of radar moments, select a time or height of interest, and then “drill down” through images of spectrograms to individual Doppler spectra or time- and height-sequences of spectra. Also available are images summarizing spectral characteristics, such as number of spectral peaks, spectral shape information (skewness and kurtosis), moment uncertainty estimates, and hydrometeor vs. clutter identification as produced by the ARM MicroARSCL (Microphysical Active Remote Sensing of Clouds) value-added product. In addition to the access and visualization tools, we are developing a Doppler spectra simulator capable of generating Doppler spectra from liquid, mixed-phase, and solid cloud constituents and precipitation. The Doppler spectra simulator can be used as an interface between explicit microphysics models and Doppler spectra observations from the ARM radars. The plan is to ultimately make the spectra simulator available from within the spectra browser, allowing a user to associate observed spectra with the microphysical conditions capable of producing them.

54 ENVIRONMENTAL SCIENCES↗

Feedback on Forty-year Long Clean-up Operations of a Contaminated Soil for Environmental Purpose - 20026

One of the CEA facilities in France is the place of miscellaneous mapping and clean-up operations since the 1980's. The final purpose of the conducted work deals with the environmental remediation of the building. In France, the absence of a regulatory framework for the management of sites polluted by radioactive substances, especially as the lack of release thresholds, has led to develop different approaches of soil radiological characterization. The geostatistical approach is part of them. Preliminary investigations are an unavoidable step prior to clearance and remediation. First, historical analysis enables to define site perimeters to investigate as well as to precisely locate expected contaminated parts. For radioactive pollutants, the media (water, soil, air) and transfer routes participate in the definition of the investigation perimeter and thus also need to be identified through a geological study. At the same time, functional analysis leads to choose the best measurement means which could provide useful information when combined with visual inspection. An equipment well adapted to easy-to-measure radionuclides as gamma emitters, such as gamma probe or on-site gamma spectrometry, is usually selected as a non-destructive assay. Coupled with spatial positions, processed on-site radiological data can be mapped. Data processing consists in mapping and kriging before a geostatistical analysis in order to identify the zones of interest to be targeted. Selected zones are not only linked to high level count rates but also to low level ones so that a pollution-free reference is known in the area. This data processing also enables to categorize waste types according to their origin and contamination levels. An expected volume of different waste then follows as well as the waste characterization equipments. In-depth investigations, e.g. core drillings and samplings, naturally ensue to aim at remediation optimization through the assessment of environmental impact. After clean-up operations, non-destructive assays as well as destructive samplings enable to check the effective clearance. Following this methodology in the present remediation work, results of the first non-destructive assay campaign highlighted a long-lived transuranic radionuclides contamination in the concrete flagstone. Successive non-destructive assays were then performed in the defined zones of interest. Count rates measured with a surface probe were first mapped. The best localization of destructive assays, i.e. core drillings at a 1 meter depth, came from this surface mapping followed by a geostatistical analysis. The concrete flagstone was totally removed. Then, the depth of soil to remove under the flagstone was optimized from the results of radiological activities measured in core drillings samples. A new surface mapping was then drawn after this partial soil excavation. The sand and demolition rubble samples, homogeneously constituted from the flagstone fragments, were analyzed by gamma spectrometry. Meanwhile, waste drums and other containers were also measured by gamma spectrometry and passive neutron measurement devices. All these results have brought miscellaneous pieces of information. In this context, major issues appear in terms of physical constraints such as the premises tininess as well as of soil sampling techniques and in terms of measurement performances assessment and the representativeness of homogeneous samples. The choice of radiological soil and waste characterization devices is described in the light of enhanced performances by keeping in mind radiation protection requirements and a willing to always optimize waste categories (very low level waste) and volume. The improvement of the characterization methods appears through this forty-year long work while sharing the feedback of encountered difficulties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Department of Energy's Biological and Environmental Research Strategic Data Roadmap for Earth System Science

Rapid advances in experimental, sensor, and computational technologies and techniques are driving exponential growth in the volume, acquisition rate, variety, and complexity of scientific data. This wealth of scientifically meaningful data has tremendous potential to lead to scientific discovery. However, to achieve scientific breakthroughs, these data must be exploitable—they must be analyzed effectively and efficiently and the results shared and communicated easily within the wider Department of Energy’s (DOE’s) Biological and Environmental Research (BER) Climate and Environmental Sciences Division (CESD) community. The explosion in data complexity and scale makes these tasks exceedingly difficult to achieve, particularly given that an increasing number of disciplines are working across techniques, integrating simulation and experimental or observational results (see Table 5 in Appendix 2). Consequently, we need new approaches to data management, analysis, and visualization that provide research teams with easy-to-use and scalable end-to-end solutions. These solutions must facilitate (and where feasible, automate and capture) every stage in the data lifecycle (shown in Figure 1), from collection to management, annotation, sharing, discovery, analysis, and visualization. In addition, the core functionalities are the same across climate science communities, but they require customization to adapt to specific needs and fit into research and analysis workflows. To this end, the mission of CESD’s Data and Informatics Program is to integrate all existing and future distributed CESD data holdings into a seamless and unified environment for the acceleration of Earth system science.

54 ENVIRONMENTAL SCIENCES↗

Chimbuko: A Workflow-Level Scalable Performance Trace Analysis Tool

ABSTRACT Due to the sheer volume of data it is typically impractical to analyze the detailed performance of an HPC application running at-scale. While conventional small-scale benchmarking and scaling studies are often sufficient for simple applications, many modern workflow-based applications couple multiple elements with competing resource demands and complex inter-communication patterns for which performance cannot easily be studied in isolation and at small scale. This work discusses Chimbuko, a performance analysis framework that provides real-time, in situ anomaly detection. By focusing specifically on performance anomalies and their origin (aka provenance), data volumes are dramatically reduced without losing necessary details. To the best of our knowledge, Chimbuko is the first online, distributed, and scalable workflow-level performance trace analysis framework. We demonstrate the tool's usefulness on Oak Ridge National Laboratory's Summit system.

97 MATHEMATICS AND COMPUTING↗