Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using coherent X-rays as a probe, this approach overlooks the phase component of the illumination field (probe), leading to artifacts in phase-retrieved projection images, which are then propagated to the reconstructed 3D sample representation. The problem intensifies in nano-holotomography with focusing optics, which, due to various imperfections creates high-frequency components in the probe function. Here, we present a new iterative reconstruction scheme for holotomography, simultaneously retrieving the complex-valued probe function. Implemented on GPUs, this algorithm results in 3D reconstruction resolving twice thinner layers in a 3D ALD standard sample measured using nano-holotomography.

Nikitin, Viktor↗

Flux Recovery of a Forward Osmosis Membrane After a Fouling Process

Wastewater treatment through Forward Osmosis (FO) membranes is a process that has been evaluated in the past years as an innovative technology for the Next Generation Life Support Systems. FO technologies are cost effective, and require very low energy consumption, but are subject to membrane fouling. Membrane fouling occurs when unwanted materials accumulate on the active side of the membrane during the wastewater treatment process, which leads to a decrease in membrane flow rates. Membrane fouling can be reversed with the use of antifoulant solutions. The aim of this study is to identify the materials that cause flow rate reduction due to membrane fouling, as well as to evaluate the flux recovery after membrane treatment using commercially available antifoulants. 3D Laser Scanning Microscope images were taken to observe the surface of the membrane. Fourier Transform Infrared (FTIR) spectrometry results identified possible compounds that cause membrane fouling and FO testing results demonstrated flow rate recovery after membrane treatment using antifoulants.

Forward osmosis↗

Improvements in Optical Surface Measurement Using Reflected Computer Vision Targets

Since 2021, NREL has been developing a system to measure heliostats by measuring the deflection of printed computer vision targets, called the Reflected Target Non-intrusive Assessment (ReTNA) [6], [7]. While this system will have lower resolution than a fringe deflectometry system, it has several important advantages that make it a complimentary technology: 2D surface slope measurement can be generated from a single image, it can operate in ambient lighting, target points can be directly located in 3D space with photogrammetry allowing for a non-flat target, and it's well suited to using a smaller target, and multiple images to measure larger optical surfaces. ReTNA has undergone several significant changes and improvements, described below. This talk will summarize new system layouts designed for commercial use, new computer vision algorithms used to automate the analysis process and validation campaigns for the ReTNA software.

computer vision↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Three-dimensional profilometry using a Dammann grating

We propose three-dimensional (3D) profilometry based on a Fourier transform in which a two-dimensional (2D) Dammann grating and a cylindrical lens are used to generate structured light. The Dammann grating splits most of the illumination power into a 2D diffractive spot matrix. The cylindrical lens transforms these 2D diffractive spots into one-dimensional fringe lines that are projected on an object. The produced projection fringes have the advantages of high brightness and high contrast and compression ratios. The experiments have verified the proposed 3D profilometry. The 3D profilometry using Dammann grating should be of high interest for practical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diode-based additive manufacturing of metals using an optically-addressable light valve

We present that Selective Laser Melting (SLM) of metal powder bed layers, whereby 3D metal objects can be printed from a digital file with unprecedented design flexibility, is spurring manufacturing innovations in medical, automotive, aerospace and textile industries. Because SLM is based on raster-scanning a laser beam over each layer, the process is relatively slow compared to most traditional manufacturing methods (hours to days), thus limiting wider spread use. Here we demonstrate the use of a large area, photolithographic method for 3D metal printing, using an optically-addressable light valve (OALV) as the photomask, to print entire layers of metal powder at once. An optical sheet of multiplexed ~5 kW, 20 ms laser diode and ~1 MW, 7 ns Q-switched laser pulses are used to selectively melt each layer. Finally, the patterning of near infrared light is accomplished by imaging 470 nm light onto the transmissive OALV, which consists of polarization-selective nematic liquid crystal sandwiched between a photoconductor and transparent conductor for switching.

36 MATERIALS SCIENCE↗

TomoPyUI : a user-friendly tool for rapid tomography alignment and reconstruction

The management and processing of synchrotron and neutron computed tomography data can be a complex, labor-intensive and unstructured process. Users devote substantial time to both manually processing their data ( i.e. organizing data/metadata, applying image filters etc. ) and waiting for the computation of iterative alignment and reconstruction algorithms to finish. In this work, we present a solution to these problems: TomoPyUI , a user interface for the well known tomography data processing package TomoPy . This highly visual Python software package guides the user through the tomography processing pipeline from data import, preprocessing, alignment and finally to 3D volume reconstruction. The TomoPyUI systematic intermediate data and metadata storage system improves organization, and the inspection and manipulation tools (built within the application) help to avoid interrupted workflows. Notably, TomoPyUI operates entirely within a Jupyter environment. Herein, we provide a summary of these key features of TomoPyUI , along with an overview of the tomography processing pipeline, a discussion of the landscape of existing tomography processing software and the purpose of TomoPyUI , and a demonstration of its capabilities for real tomography data collected at SSRL beamline 6-2c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Method of Absorption-Phase Nanotomography for 3D Observation of Mineral-Organic-Water Textiles and its Application to Pristine Carbonaceous Chondrites

Pristine carbonaceous chondrites contain fine-grained matrix, which is composed largely of amorphous silicates, sub-micron silicate and sulfide crystals, and organic materials. They are regarded as primitive dust in the early Solar System that have suffered minimal alteration in their parent bodies. The matrix generally has different lithologies; some of them are unaltered but some are more or less aqueously altered. Their textures have been examined in 2D usually by FE-SEM/EDS, TEM/EDS, nano-SIMS and micro-XRD. Observation of their complex fine textures, such as spatial relation between different lithologies in 3D, is important for understanding aggregation and alteration processes. Synchrotron radiation (SR)-based X-ray tomography reveals 3D structures nondestructively with high spatial resolution of approximately greater than 100 nm. We have developed a new technique using absorption contrasts called "dual-energy tomography" (DET) to obtain 3D distribution of minerals at SPring-8, SR facility in Japan, and applied successfully to Itokawa particles. Phase and absorption contrast images can be simultaneously obtained in 3D by using "scanning-imaging x-ray microscopy" (SIXM) at SPring-8, which can discriminate between void, water and organic materials. We applied this technique combined with FIB micro-sampling to carbonaceous chondrites to search for primitive liquid water. In this study, we combined the DET and SIXM to obtain three dimensional submicron-scale association between minerals, organic materials and water and applied this to pristine carbonaceous chondrites.

Tsuchiyama, A.↗

Processing Near-Infrared Imagery of the Orion Heatshield During EFT-1 Hypersonic Reentry

The Scientifically Calibrated In-Flight Imagery (SCIFLI) team captured high-resolution, calibrated, near-infrared imagery of the Orion capsule during atmospheric reentry of the EFT-1 mission. A US Navy NP-3D aircraft equipped with a multi-band optical sensor package, referred to as Cast Glance, acquired imagery of the Orion capsule's heatshield during a period when Orion was slowing from approximately Mach 10 to Mach 7. The line-of-sight distance ranged from approximately 65 to 40 nmi. Global surface temperatures of the capsule's thermal heatshield derived from the near-infrared intensity measurements complemented the in-depth (embedded) thermocouple measurements. Moreover, these derived surface temperatures are essential to the assessment of the thermocouples' reliance on inverse heat transfer methods and material response codes to infer the surface temperature from the in-depth measurements. The paper describes the image processing challenges associated with a manually-tracked, high-angular rate air-to-air observation. Issues included management of significant frame-to-frame motions due to both tracking jerk and jitter as well as distortions due to atmospheric effects. Corrections for changing sky backgrounds (including some cirrus clouds), atmospheric attenuation, and target orientations and ranges also had to be made. The image processing goal is to reduce the detrimental effects due to motion (both sensor and capsule), vibration (jitter), and atmospherics for image quality improvement, without compromising the quantitative integrity of the data, especially local intensity (temperature) variations. The paper will detail the approach of selecting and utilizing only the highest quality images, registering several co-temporal image frames to a single image frame to the extent frame-to-frame distortions would allow, and then co-adding the registered frames to improve image quality and reduce noise. Using preflight calibration data, the registered and averaged infrared intensity images were converted to surface temperatures on the Orion capsule's heatshield. Temperature uncertainties will be discussed relative to uncertainties of surface emissivity and atmospheric transmission loss. Comparison of limited onboard surface thermocouple data to the image derived surface temperature will be presented.

Spisz, Thomas S.↗

SU-G-JeP4-07: Evaluation of Intrafraction Motion Using 3D Surface Guided Radiation Therapy in Lung SBRT

Purpose: Surface guided radiation therapy (SGRT) uses stereoscopic video images in combination with patterns projected onto the patient’s surface to dynamically capture and reconstruct a 3D surface map. In this work, we used a C-RAD Catalyst HD system (C-RAD) to evaluate intrafraction motion in the delivery of lung SBRT. Methods: The surface acquired from the 4DCT images from our preliminary cohort of eight lung cancer patients treated with SBRT were matched to the surface images acquired prior to each treatment. Additionally, a CBCT image set was acquired. A linear regression model was established between the external and internal motion of tumor during pretreatment and used to predict the CBCT deviation during treatment. The shifts determined from CBCT and the shifts from surface map imaging were compared and assessed using Bland-Altman method. For intrafraction motion, we assessed the percentage of mean errors that fell outside of the threshold of 2 mm, 3 mm, and 5 mm along the translational directions. The required PTV margin was quantified over the course of treatment. The correlation between intrafraction treatment time and mean error of 3D displacement was evaluated using the Pearson coefficient, r Results: A total of 7971 data points were analyzed. Deviations of 2mm, 3mm, and 5mm were observed less than 7%, 2 %, and 0 % of the time along the translational direction. CBCT and Catalyst showed close agreement during patient positioning. Furthermore, the calculated PTV margins were less than our clinical tolerance of 5 mm. Using the Pearson coefficient r,the mean error of 3D displacement showed significant correlation with treatment time (r=0.69, p= 0.000002). Conclusion: SGRT can be used to ensure accurate patient positioning during treatment without an additional delivery of dose to the patient. This study shows that importance of treatment time as a consideration during the treatment planning process.

60 APPLIED LIFE SCIENCES↗

A Robust Data-Driven Approach for Mechanical Serial Sectioning

Mechanical serial sectioning (MSS) provides detailed microstructural information across large length scales. By repeatedly removing thin layers of material and imaging the exposed surface, a 3D representation of a specimen’s internal structure can be constructed, enabling failure analysis and feature identification that are otherwise inaccessible via conventional 2D or nondestructive evaluation techniques. Achieving consistent and accurate material removal can be challenging due to system variability, requiring an experienced operator to manually adjust parameters, prolonging data collection times and necessitating post-processing routines to standardize the data. Here, to address these challenges, this paper presents the employment of a one-step model predictive control (MPC) framework tailored to a run-to-run (R2R) controller. The R2R-MPC controller automates the parameter selection process, improving the consistency of material removal through iterative feedback for disturbance rejection and accurate tracking of the target removal rate. Using a data-driven approach, the controller robustly adapts to changing material characteristics. The effectiveness of the R2R-MPC controller is demonstrated through simulation and experimental results and compared to previous data collection procedures.

3D Materials Science↗

The use of subchondral bone topography to approximate the center of rotation of the elbow joint in dogs

Abstract Objectives The aim of this study was to compare the approximate center of rotation in normal and diseased elbows in dogs. Study design Cross‐sectional study Sample population Computer tomography scans of nine dogs with unilateral fragmented medial coronoid process (FMCP). Methods A board certified radiologist confirmed that each dog had unilateral FMCP, and a normal contralateral elbow. Digital 3D models of all elbow joints were uploaded into a surgical planning software package. Four axes approximating the center of rotation (COR) of elbow joints were generated using five geometric shapes based on subchondral topography of the humeral condyle radius and ulna. Images showing the locations where axes exited the medial and lateral cortex of the humeral condyle were captured and imported into a second software package, for measurement of distances between exit points and the origin of a system of axes. Results In normal joints 20/27 (74%) axes exited the medial cortex, and 25/27 (93%) axes exited the lateral cortex cranial and distal to the medial and lateral epicondyles, respectively. In diseased joints 22/27 (81%) axes exited medial cortex and 19/27 (70%) axes exited the lateral cortex, caudal and distal to the medial and lateral epicondyles, respectively. Conclusion Based on CT‐ derived geometry, the COR of elbow affected with FMCP was generally more caudal than normal. Clinical significance External landmarks approximating the location of the elbow COR are provided, and while not validated, may assist in planning, creation, and assessment of procedures for FMCP.

Berger, Chen↗

SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the potential of making breast MRI more widely accessible to and more tolerable by the patients. JMA is the inventor of United States patents that are owned by the University of Texas Board of Regents and currently licensed to GE Healthcare and Siemens Gmbh.

60 APPLIED LIFE SCIENCES↗

The role of CenKR in the coordination of Rhodobacter sphaeroides cell elongation and division

ABSTRACT Cell elongation and division are essential aspects of the bacterial life cycle that must be coordinated for viability and replication. The impact of misregulation of these processes is not well understood as these systems are often not amenable to traditional genetic manipulation. Recently, we reported on the CenKR two-component system (TCS) in the Gram-negative bacterium Rhodobacter sphaeroides that is genetically tractable, widely conserved in α-proteobacteria, and directly regulates the expression of components crucial for cell elongation and division, including genes encoding subunit of the Tol-Pal complex. In this work, we show that overexpression of cenK results in cell filamentation and chaining. Using cryo-electron microscopy (cryo-EM) and cryo-electron tomography (cryo-ET), we generated high-resolution two-dimensional (2D) images and three-dimensional (3D) volumes of the cell envelope and division septum of wild-type cells and a cenK overexpression strain finding that these morphological changes stem from defects in outer membrane (OM) and peptidoglycan (PG) constriction. By monitoring the localization of Pal, PG biosynthesis, and the bacterial cytoskeletal proteins MreB and FtsZ, we developed a model for how increased CenKR activity leads to changes in cell elongation and division. This model predicts that increased CenKR activity decreases the mobility of Pal, delaying OM constriction, and ultimately disrupting the midcell positioning of MreB and FtsZ and interfering with the spatial regulation of PG synthesis and remodeling. IMPORTANCE By coordinating cell elongation and division, bacteria maintain their shape, support critical envelope functions, and orchestrate division. Regulatory and assembly systems have been implicated in these processes in some well-studied Gram-negative bacteria. However, we lack information on these processes and their conservation across the bacterial phylogeny. In R. sphaeroides and other α-proteobacteria, CenKR is an essential two-component system (TCS) that regulates the expression of genes known or predicted to function in cell envelope biosynthesis, elongation, and/or division. Here, we leverage unique features of CenKR to understand how increasing its activity impacts cell elongation/division and use antibiotics to identify how modulating the activity of this TCS leads to changes in cell morphology. Our results provide new insight into how CenKR activity controls the structure and function of the bacterial envelope, the localization of cell elongation and division machinery, and cellular processes in organisms with importance in health, host-microbe interactions, and biotechnology.

59 BASIC BIOLOGICAL SCIENCES↗

Enhanced joining strength in additive-manufactured polylactic-acid structures fused by embedded heated metallic meshes

Additively manufactured thermoplastic polymers, such as polylactic acid (PLA), hold significant promise for sustainable engineering structures, including wind turbine blades. Upscaling these structures beyond the limitations of 3D printer build volumes is a challenge; fusion joining presents a potential solution. This paper introduces a displacement-controlled resistance welding process for PLA, as an alternative to the typical force-controlled methods. Here, we investigated the bonding quality of resistance-welded and adhesive-bonded PLA beams through three-point bending and measured the surface deformations using digital image correlation. Different metal meshes (30%/0.11 mm Ni—Cu, 34%/0.07 mm Ni—Cu, and 36%/0.25 mm Co—Ni) served as heating elements. The process parameters were varied for the 34%/0.07 mm Ni—Cu mesh to identify an optimum set of parameters. Results showed that this optimized displacement-controlled welding achieved 94% of the original strength of monolithic samples. This indicates that the new welding process not only ensures high-quality bonding and fine surface finishing but also promotes sustainability, recyclability, and economic efficiency in various polymer and composite structural applications.

Additive manufacturing↗

X-ray computed tomography-based porosity analysis: Algorithms and application for porous woody biomass

The properties of lignocellulosic biomass, such as bulk physical, thermal, and mechanical properties, as well as the mobility of enzymes or catalysts, are largely affected by porosity, pore structures, and pore size distribution. While X-ray computed tomography (CT) has been introduced to effectively produce 3D volumetric images of material microstructure, a quantitative porosity analysis from the 3D images has never been done. This work introduces a first-of-its-kind X-ray CT-based quantitative porosity analysis method and applies the developed toolkit to characterize the internal porosity distribution of loblolly pine. A sample loblolly pine chip was scanned by a nano-resolution X-ray CT system and digitally reconstructed after a sequence of image processing operations. Here, a comprehensive porosity analysis was then performed to quantify the envelope porosity, the spatial distribution of local porosity, and the directional porosity. Solutions to the various challenges in image processing, porosity calculation, and large data handling are provided.

42 ENGINEERING↗