At least 703 records · Page 39

Applying Acoustic Emission to Large Format Additive Manufacturing

Large format additive manufacturing (AM) is being adapted as a method of producing large structures in a short lead time and cost-effective way. With the growing advancement in AM techniques and application, machine monitoring and part qualification is highly needed. There has been leading research focused on the manufacturing development and feedstock material but minimum research on the structural health monitoring (SHM), defect detection, and nondestructive evaluation (NDE) for large format AM. Scanning large structure using conventional nondestructive testing (NDT) techniques, such as ultrasound or X-ray, and searching for potential defects can be very time consuming, challenging and cost prohibitive. Acoustic emission (AE) is a passive technique that can be used to monitor and locate defect progression in large structures by distributing group of sensors around the part. This research outlines the necessary procedure for implementing AE to AM as a reliability method. The topics this research will display are: (a) Wave propagation/velocity evaluation, (b) an AE attenuation characterization for the anisotropic printed structure and material, (c) background noise measurements of the extruder and gantry system, and (d) assist in optimal sensor selection and placement for monitoring large AM structures with demonstration. This work establishes the foundation for scaling up the SHM-AE system for the large additive platform.

Spencer, Ryan↗

Experimental observation of acoustic emissions generated by a pulsed proton beam from a hospital-based clinical cyclotron

Purpose: To measure the acoustic signal generated by a pulsed proton spill from a hospital-based clinical cyclotron. Methods: An electronic function generator modulated the IBA C230 isochronous cyclotron to create a pulsed proton beam. The acoustic emissions generated by the proton beam were measured in water using a hydrophone. The acoustic measurements were repeated with increasing proton current and increasing distance between detector and beam. Results: The cyclotron generated proton spills with rise times of 18 μs and a maximum measured instantaneous proton current of 790 nA. Acoustic emissions generated by the proton energy deposition were measured to be on the order of mPa. The origin of the acoustic wave was identified as the proton beam based on the correlation between acoustic emission arrival time and distance between the hydrophone and proton beam. The acoustic frequency spectrum peaked at 10 kHz, and the acoustic pressure amplitude increased monotonically with increasing proton current. Conclusions: The authors report the first observation of acoustic emissions generated by a proton beam from a hospital-based clinical cyclotron. When modulated by an electronic function generator, the cyclotron is capable of creating proton spills with fast rise times (18 μs) and high instantaneous currents (790 nA). Measurements of the proton-generated acoustic emissions in a clinical setting may provide a method for in vivo proton range verification and patient monitoring.

60 APPLIED LIFE SCIENCES↗

Ultrasonics: Fundamentals, Technologies, and Applications

This is a new edition of a bestselling industry reference. Discusses the science, technology, and applications of low and high power ultrasonics, including industrial implementations and medical uses. Reviews the basic equations of acoustics, starting from basic wave equations and their applications. New material on property determination, inspection of metals (NDT) and non-metals, imaging, process monitoring and control. Expanded discussion of transducers, transducer wave-fields, scattering, attenuation and measurement systems and models. New material that discusses high power ultrasonics - in particular using mechanical effects and sonochemistry, including applications to nano-materials. Examines diagnosis, therapy, and surgery from a technology and medical physics perspective.

99 GENERAL AND MISCELLANEOUS↗

Reservoir Stimulation Optimization with Operational Monitoring for Creation of EGS

EGS field projects have not sustained production at rates greater than ½ of what is needed for economic viability. The primary limitation that makes commercial EGS infeasible is our current inability to cost-effectively create high-permeability reservoirs from impermeable, igneous rock within the 3,000-10,000 ft depth range. Our goal is to develop a novel fracturing fluid technology that maximizes reservoir permeability while reducing stimulation cost and environmental impact. Laboratory equipment development to advance laboratory characterization/monitoring is also a priority of this project to study and optimize the physicochemical properties of these fracturing fluids in a range of reservoir conditions. Barrier G is the primarily intended GTO barrier to be addressed as well as support addressing barriers D, E and I.

15 GEOTHERMAL ENERGY↗

Frequency‐Locked Wireless Multifunctional Surface Acoustic Wave Sensors

Abstract Surface acoustic waves (SAWs) have shown great potential for developing sensors for structural health monitoring (SHM) and lab‐on‐a‐chip (LOC) applications. Existing SAW sensors mainly rely on measuring the frequency shifts of high‐frequency (e.g., >0.1 GHz) resonance peaks. This study presents frequency‐locked wireless multifunctional SAW sensors that enable multiple wireless sensing functions, including strain sensing, temperature measurement, water presence detection, and vibration sensing. These sensors leverage SAW resonators on piezoelectric chips, inductive coupling‐based wireless power transmission, and, particularly, a frequency‐locked wireless sensing mechanism that works at low frequencies (e.g., <0.1 GHz). This mechanism locks the input frequency on the slope of a sensor's reflection spectrum and monitors the reflection signal's amplitude change induced by the changes of sensing parameters. The proof‐of‐concept experiments show that these wireless sensors can operate in a low‐power active mode for on‐demand wireless strain measurement, temperature sensing, and water presence detection. Moreover, these sensors can operate in a power‐free passive mode for vibration sensing, with results that agree well with laser vibrometer measurements. It is anticipated that the designs and mechanisms of the frequency‐locked wireless SAW sensors will inspire researchers to develop future wireless multifunctional sensors for SHM and LOC applications.

Bo, Luyu↗

A source-synchronous filter for uncorrelated receiver traces from a swept-frequency seismic source

We have developed a novel algorithm to reduce noise in signals obtained from swept-frequency sources by removing out-of-band external noise sources and distortion caused from unwanted harmonics. The algorithm is designed to condition nonstationary signals for which traditional frequency-domain methods for removing noise have been less effective. The source synchronous filter (SSF) is a time-varying narrow band filter, which is synchronized with the frequency of the source signal at all times. Because the bandwidth of the filter needs to account for the source-to-receiver propagation delay and the sweep rate, SSF works best with slow sweep rates and moveout-adjusted waveforms to compensate for source-receiver delays. The SSF algorithm was applied to data collected during a field test at the University of California Santa Barbara’s Garner Valley downhole array site in Southern California. At the site, a 45 kN shaker was mounted on top of a one-story structure and swept from 0 to 10 Hz and back over 60 s (producing useful seismic waves greater than 1.6 Hz). The seismic data were captured with small accelerometer and geophone arrays and with a distributed acoustic sensing array, which is a fiber-optic-based technique for the monitoring of elastic waves. The result of the application of SSF on the field data is a set of undistorted and uncorrelated traces that can be used in different applications, such as measuring phase velocities of surface waves or applying convolution operations with the encoder source function to obtain traveltimes. Lastly, the results from the SSF were used with a visual phase alignment tool to facilitate developing dispersion curves and as a prefilter to improve the interpretation of the data.

58 GEOSCIENCES↗

Acoustical Detection Of Leakage In A Combustor

Abnormal combustion excites characteristic standing wave. Acoustical leak-detection system gives early warning of failure, enabling operating personnel to stop combustion process and repair spray bar before leak grows large enough to cause damage. Applicable to engines, gas turbines, furnaces, and other machines in which acoustic emissions at known frequencies signify onset of damage. Bearings in rotating machines monitored for emergence of characteristic frequencies shown in previous tests associated with incipient failure. Also possible to monitor for signs of trouble at multiple frequencies by feeding output of transducer simultaneously to multiple band-pass filters and associated circuitry, including separate trigger circuit set to appropriate level for each frequency.

Puster, Richard L.↗

Integrated Monitoring Volume: A Summary of Monitoring Studies Conducted in Niagaran Carbonate Pinnacle Reefs During Enhanced Oil Recovery with CO 2

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. During the MRCSP Phase III monitoring period, over 1 million metric tons of CO 2 was injected into ten Silurian-age (Niagaran) pinnacle reef reservoirs in Otsego County, Michigan that are operated by Core Energy, LLC. There are over 800 pinnacle reefs in northern Michigan, and collectively, these geologic features have sufficient capacity to store several hundred million metric tons of CO 2 . Moreover, most of the reefs are oil-bearing and went through primary production in the 1970s and 1980s; therefore, by injecting CO 2 into the reefs, there is a real opportunity to realize additional (enhanced) oil recovery (EOR) and to permanently store CO 2 after EOR. A key objective of the MRCSP Phase III project is to evaluate the effectiveness of various technologies for monitoring CO 2 that has been injected into deep geologic formations. Monitoring may be required at CO 2 storage sites for a variety of reasons, including to meet UIC Class II (EOR sites) or Class VI (storage only sites) permit requirements or EPA greenhouse gas reporting rule requirements or to qualify for tax credits under the 45Q tax credit rule. The results of this monitoring study should prove useful to operators considering using carbonate pinnacle reefs of Northern Michigan for CO 2 storage.

01 COAL, LIGNITE, AND PEAT↗

A new method for wideband characterization of resonator-based sensing platforms

A new approach to the electronic instrumentation for extracting data from resonator-based sensing devices (e.g., microelectromechanical, piezoelectric, electrochemical, and acoustic) is suggested and demonstrated here. Traditionally, oscillator-based circuitry is employed to monitor shift in the resonance frequency of the resonator. These circuits give a single point measurement at the frequency where the oscillation criterion is met. However, the resonator response itself is broadband and contains much more information than a single point measurement. Here, we present a method for the broadband characterization of a resonator using white noise as an excitation signal. The resonator is used in a two-port filter configuration, and the resonator output is subjected to frequency spectrum analysis. The result is a wideband spectral map analogous to the magnitude of the S21 parameters of a conventional filter. Compared to other sources for broadband excitation (e.g., frequency chirp, multisine, or narrow time domain pulse), the white noise source requires no design of the input signal and is readily available for very wide bandwidths (1 MHz-3 GHz). Moreover, it offers simplicity in circuit design as it does not require precise impedance matching; whereas such requirements are very strict for oscillator-based circuit systems, and can be difficult to fulfill. This results in a measurement system that does not require calibration, which is a significant advantage over oscillator circuits. Simulation results are first presented for verification of the proposed system, followed by measurement results with a prototype implementation. A 434 MHz surface acoustic wave (SAW) resonator and a 5 MHz quartz crystal microbalance (QCM) are measured using the proposed method, and the results are compared to measurements taken by a conventional bench-top network analyzer. Maximum relative differences in the measured resonance frequencies of the SAW and QCM resonators are 0.0004% and 0.002%, respectively. The ability to track a changing sensor response is demonstrated by inducing temperature variations and measuring resonance frequency simultaneously using the proposed technique in parallel with a network analyzer. The relative difference between the two measurements is about 5.53 ppm, highlighting the impressive accuracy of the proposed system. Using commercially available digital signal processors (DSPs), we believe that this technique can be implemented as a system-on-a-chip solution resulting in a very low cost, easy to use, portable, and customizable sensing system. In addition, given the simplicity of the signal and circuit design, and its immunity to other common interface concerns (injection locking, oscillator interference, and drift, etc.), this method is better suited to accommodating array-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TEMPERATURE MONITORING OPTIONS AVAILABLE AT THE IDAHO NATIONAL LABORATORY ADVANCED TEST REACTOR

As part of the Advanced Test Reactor National Scientific User Facility (ATR NSUF) program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced sensors for irradiation testing. To meet recent customer requests, an array of temperature monitoring options is now available to ATR users. The method selected is determined by test requirements and budget. Melt wires are the simplest and least expensive option for monitoring temperature. INL has recently verified the melting temperature of a collection of materials with melt temperatures ranging from 100 to 1000 C with a differential scanning calorimeter installed at INL’s High Temperature Test Laboratory (HTTL). INL encapsulates these melt wires in quartz or metal tubes. In the case of quartz tubes, multiple wires can be encapsulated in a single 1.6 mm diameter tube. The second option available to ATR users is a silicon carbide temperature monitor. The benefit of this option is that a single small monitor (typically 1 mm x 1 mm x 10 mm or 1 mm diameter x 10 mm length) can be used to detect peak irradiation temperatures ranging from 200 to 800 C. Equipment has been installed at INL’s HTTL to complete post-irradiation resistivity measurements on SiC monitors, a technique that has been found to yield the most accurate temperatures from these monitors. For instrumented tests, thermocouples may be used. In addition to Type-K and Type-N thermocouples, a High Temperature Irradiation Resistant ThermoCouple (HTIR-TC) was developed at the HTTL that contains commercially-available doped molybdenum paired with a niobium alloy thermoelements. Long duration high temperature tests, in furnaces and in the ATR and other MTRs, demonstrate that the HTIR-TC is accurate up to 1800 C and insensitive to thermal neutron interactions. Thus, degradation observed at temperatures above 1100 C with Type K and N thermocouples and decalibration due to transmutation with tungsten-rhenium and platinum rhodium thermocouples can be avoided. INL is also developing an Ultrasonic Thermometry (UT) capability. In addition to small size, UT’s offer several potential advantages over other temperature sensors. Measurements may be made near the melting point of the sensor material, potentially allowing monitoring of temperatures up to 3000 C. In addition, because no electrical insulation is required, shunting effects are avoided. Most attractive, however, is the ability to introduce acoustic discontinuities to the sensor, as this enables temperature measurements at several points along the sensor length. As discussed in this paper, the suite of temperature monitors offered by INL is not only available to ATR users, but also to users at other MTRs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Situ Acoustic Measurements of Temperature Profile in Extreme Environments

A gasifier’s temperature is the primary characteristic that must be monitored to ensure its performance and the longevity of its refractory. One of the key technological challenges impacting the reliability and economics of coal and biomass gasification is the lack of temperature sensors that are capable of providing accurate, reliable, and long-life performance in an extreme gasification environment. This research has proposed, demonstrated, and validated a novel approach that uses a noninvasive ultrasound method that provides real-time temperature distribution monitoring across the refractory, especially the hot face temperature of the refractory. The essential idea of the ultrasound measurements of segmental temperature distribution is to use an ultrasound propagation waveguide across a refractory that has been engineered to contain multiple internal partial reflectors at known locations. When an ultrasound excitation pulse is introduced on the cold side of the refractory, it will be partially reflected from each scatterer in the US propagation path in the refractory wall and returned to the receiver as a train of partial echoes. The temperature in the corresponding segment can be determined based on recorded ultrasonic waveform and experimentally defined relationship between the speed of sound and temperature. The ultrasound measurement method offers a powerful solution to provide continuous real time temperature monitoring for the occasions that conventional thermal, optical and other sensors are infeasible, such as the impossibility of insertion of temperature sensor, harsh environment, unavailable optical path, and more. Our developed ultrasound system consists of an ultrasound engineered waveguide, ultrasound transducer/receiver, and data acquisition, logging, interpretation, and online display system, which is simple to install on the existing units with minimal modification on the gasifier or use with new units. This system has been successfully tested with a 100 kW pilot scale down flow oxyfuel combustor, capturing in real time temperature changes during all relevant combustion process changes. The ultrasound measurements have excellent agreement with thermo- couple measurements, and appear to be more sensitive to temperature changes before the thermocouples response, which is believed to be the first demonstration of ultrasound measurements segmental temperature distribution across refractories.

47 OTHER INSTRUMENTATION↗

Detecting cavitation in mercury exposed to a high-energy pulsed proton beam

The Oak Ridge National Laboratory Spallation Neutron Source employs a high-energy pulsed proton beam incident on a mercury target to generate short bursts of neutrons. Absorption of the proton beam produces rapid heating of the mercury, resulting in the formation of acoustic shock waves and the nucleation of cavitation bubbles. The subsequent collapse of these cavitation bubbles promote erosion of the steel target walls. Preliminary measurements using two passive cavitation detectors (megahertz-frequency focused and unfocused piezoelectric transducers) installed in a mercury test target to monitor cavitation generated by proton beams with charges ranging from 0.041 to 4.1 C will be reported on. Cavitation was initially detected for a beam charge of 0.082 C by the presence of an acoustic emission approximately 250 s after arrival of the incident proton beam. This emission was consistent with an inertial cavitation collapse of a bubble with an estimated maximum bubble radius of 0.19 mm, based on collapse time. The peak pressure in the mercury for the initiation of cavitation was predicted to be 0.6 MPa. For a beam charge of 0.41 C and higher, the lifetimes of the bubbles exceeded the reverberation time of the chamber (~300 s), and distinct windows of cavitation activity were detected, a phenomenon that likely resulted from the interaction of the reverberation in the chamber and the cavitation bubbles.

36 MATERIALS SCIENCE↗

Distributed Acoustic Sensing (DAS) Data for Periodic Hydraulic Tests

California State University Long Beach evaluated hydraulic connectivity among geothermal wells using Periodic Hydraulic Testing (PHT) and Distributed Acoustic Sensing (DAS). The principal was to create a pressure signal in one well and observe the responding pressure signals in one or more observation wells to assess the permeability and storage of the fracture network that connects the two wells. DAS measured strain at mHz frequency in monitoring wells in response to PHT.

15 GEOTHERMAL ENERGY↗

IC Project: w19_hossfault “Modelling of stick-slip behavior in sheared granular fault gouge & nonlinear elasticity behavior in cracked solid”

Low frequency earthquakes, non-volcanic tremor, and acoustic emissions are examples of weak seismic signals that may help detect major seismic events, i.e., earthquakes. In a laboratory setting, in which stick-slip events are simulated, acoustic emissions are detected far from the stick-slip events. In both, field and laboratory scale cases, the acoustic emission signals are sourced or detected in a volume remote from the volume that spawns the earthquake. Therefore, it is relevant to establish the causal relationship between signals detected on passive, remote monitors and the dynamics of the elastic structures that launch important seismic events. The work conducted under this IC allocation allowed us to utilize a numerical model that let us follow this causality, i.e., examine and connect the dynamics in a granular system (fault gouge), to signals detected on passive remote monitors. It was demonstrated that stress chains are key in the dynamics of granular systems and that their evolution is the source of the acoustic emission.

58 GEOSCIENCES↗

Sustainable Energy Solutions Task 2.0: Wind Turbine Reliability and Maintainability Enhancement through System-wide Structure Health Monitoring and Modifications to Rotating Components

An evaluation of nondestructive structural health monitoring methods was completed with over 132 documents, 37 specifically about wind turbines, summarized into a technology matrix. This matrix lists the technology, what can be monitored with this technology, and gives a short summary of the key aspects of the technology and its application. Passive and active acoustic emission equipment from Physical Acoustics Corp. and Acellent Technologies have been evaluated and selected for use in experimental state loading and fatigue tests of composite wind turbine blade materials. Acoustic Emission (AE) and Active Ultrasonic Testing (AUT), were applied to composite coupons with both simulated and actual damage. The results found that, while composites are more complicated in nature, compared to metallic structures, an artificial neural network analysis could still be used to determine damage. For the AE system, the failure mode could be determined (i.e. fiber breakage, delamination, etc.). The Acellent system has been evaluated to work well with composite materials. A test-rig for reliability testing of the rotating components was constructed. The research on the types of bearings used in the wind turbines indicated that in most of the designs, the main bearings utilized to support the shaft are cylindrical roller bearings. The accelerated degradation testing of a population of bearings was performed. Vibration and acoustic emission data was collected and analyzed in order to identify a representative degradation signal for each bearing to identify the initiation of the degradation process in the bearings. Afterwards, the RMS of the vibration signal from degradation initiation up to the end of the useful life of the bearing was selected to predict the remaining useful life of the bearing. This step included fitting Autoregressive Moving Average (ARMA) models to the degradation signals and approximating the probability distribution function (PDF) of remaining useful life based on the results of Monte-Carlo simulation of the ARMA models. This step was performed for different percentages of the degradation signal of each bearing. The accuracy of the proposed approach then was assessed by comparing the actual life of the bearing and the estimated life of the bearing from the developed models. The results were impressive and indicated that the accuracy of the models improved as more data was utilized in developing the ARMA models (we get closer to the end of the life of the bearing).

17 WIND ENERGY↗

Distributed Fiber Optic Arrays: Integrated Temperature and Seismic Sensing for Detection of CO 2 Flow, Leakage and Subsurface Distribution (Final Report)

This report describes the seismic and heat-pulse monitoring equipment, surveys, results and accomplishments of the fiber optic (FO) project funded by the U.S. Department of Energy (DOE) under Agreement Number DE-FE0012700. The formal title of the project is “Distributed Fiber Optic Arrays: Integrated Temperature and Seismic Sensing for Detection of CO 2 Flow, Leakage and Subsurface Distribution.” The project focuses on the field acquisition of FO data using Distributed Acoustic Sensing (DAS) arrays for subsurface imaging of geologic structure and to track the CO 2 migration in the injection interval using time-lapse techniques. A second component of the project uses a novel heat-pulse monitoring method that relies on Distributed Temperature Sensing (DTS) to evaluate near-field leakage of CO 2 or brine in and around the wellbore. The Southeast Regional Carbon Sequestration (SECARB) partnership hosted the project at the Anthropogenic Test site near Citronelle, Alabama after the original site host, the Kansas Geological Survey (KGS), experienced significant delays in permitting its CO 2 injection well at the Wellington Oil Field site in Kansas. The KGS project was later terminated in 2017 before an injection permit issued. A second field trial was planned for the Livingston Oil Field, located in Louisiana, but the site host ran into financial troubles and the project was terminated in 2015. A replacement field-site host was not found for the Livingston field trial. Both the Wellington, Kansas and Livingston, Louisiana projects were funded by DOE. A novel sensor platform referred to as the Modular Borehole Monitoring (MBM) system deployed at the Citronelle field site was utilized by the FO project. Two different seismic sensor technologies were incorporated in the Citronelle MBM system design including: (1) a semi-permanent, tubing-deployed, 18-level geophone array with custom hydraulic clamps; and (2) two, single mode optical fibers for Distributed Acoustic Sensing (DAS). Incorporation of the 18-level geophone array in the MBM system provided an ideal opportunity to compare the DAS response to conventional geophones. A heat-pulse monitoring system consisting of two, multi-mode optical fibers for Distributed Temperature Sensing (DTS) and copper heater element were also incorporated into the MBM package. This report provides an overview of the design of the MBM, DAS, and DTS equipment and the surveys performed during the study. The heat-pulse monitoring technique was used to diagnose a completion problem with observation well D-9-8 #2 where the MBM system was installed in 2012, thus successfully demonstrating its application for leak detection. In 2015, CO 2 unexpectedly arrived at the observation well approximately one year after CO 2 injection and heat-pulse monitoring ended. It was determined at this time that saltwater intrusion had likely penetrated the stainless-steel capillary tube containing the fibers and copper heater elements, thus preventing the heater from being used. DTS measurements indicated that the fiber had also degraded probably due to hydrogen darkening. It is recommended that the capillary tube be constructed of a more corrosive resistant material (e.g., Inconel) in the future should it be deployed in similar harsh downhole environments. Geophysical imaging of the subsurface and monitoring of the CO 2 were successful using DAS in the vertical seismic profile (VSP) survey configuration. A high resolution VSP image of the subsurface was obtained in 2014 using DAS, which exceeded our expectations in comparison to a lower resolution image obtained by SECARB in 2012 using an 80-level geophone array. A time-lapse image of the redistribution of CO 2 after injection ended in September 2014 was obtained using two DAS VSP surveys from June 2014 and December 2015, thus successfully demonstrating its application. DAS data were also acquired during a crosswell seismic survey conducted in 2014. Unfortunately, the DAS technique was not success in the crosswell survey configuration because the noise level was too high, increasing by a factor of ten, over the high frequency output (100-1,200) of the piezoelectric source.

58 GEOSCIENCES↗

Shear wave elastography prior to transjugular intrahepatic portosystemic shunt may predict the decrease in hepatic vein pressure gradient

Background: Transjugular intrahepatic portosystemic shunt (TIPS) is a procedure used to treat portal hypertension complications. Our aim was to evaluate liver and spleen stiffness measurement (LSM and SSM, respectively) changes using acoustic radiation force impulse imaging (ARFI) in comparison to Child–Pugh scores for predicting hepatic venous pressure gradient (HVPG) decreases after TIPS implantation. Methods: This prospective study included 31 consecutive clinically significant portal hypertension patients with TIPS indication. All patients received LSM and SSM before TIPS, at baseline, 2 days (follow-up 1) and 6 weeks (follow-up 2) post-implantation. HVPG was performed during the TIPS procedure. Results: The mean decrease in HVPG after TIPS was 63%. LSM and SSM decreased significantly between baseline and follow-up 2 (p < 0.001 and p < 0.001, respectively). At baseline, follow-up 1 and follow-up 2, significant correlations were detected between mean SSM and mean HVPG (p = 0.026; p = 0.018; p = 0.002, respectively). HVPG decreased to ≤ 10 mmHg in 61% of patients for which LSM, SSM, and Child–Pugh score were predictors (p = 0.033, p = 0.002 and p = 0.030, respectively). The area under the curve (AUC) for LSM, SSM, and Child–Pugh was 0.88, 0.90, and 0.84, respectively, with close sensitivity and specificity. SSM had the highest diagnostic accuracy for predicting an HVPG decrease to ≤ 10 mmHg in comparison to LSM and Child–Pugh score. Conclusion: Spleen stiffness is superior to liver stiffness and Child–Pugh score as a non-invasive surveillance tool for evaluating patients with clinically significant portal hypertension (HVPG ≥ 10 mmHg) prior to TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid Refreezing of a Marginal Ice Zone Across a Seafloor Distributed Acoustic Sensor

Abstract Seismic instruments such as broadband seismometers and distributed acoustic sensors (DAS) have a demonstrated potential for wide‐scale and continuous in situ monitoring of near‐surface environmental and anthropogenic processes. DAS is attractive for development as a multi‐geophysical observatory due to the prevalence of existing fiber infrastructure in regions with environmental, cultural, or strategic significance. Here we present results from a multi‐seasonal acquisition of DAS data on a seafloor cable in the Beaufort Sea, Alaska. During a November 2021 data collect we captured the rapid transition of ambient noise characteristics from an “ice‐free” state to an “ice‐bound” state. A sea ice formation front was plainly visible on the DAS record and was observed to propagate 20 km seaward over a period of 8 hr. Satellite‐based instrumentation were unable to record this event due to cloud cover, low light conditions, and orbital frequency.

Baker, Michael G.↗