Applicability of Industrial Test and Evaluation Practices to Future Nuclear Weapons.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract To understand the effects of the chemical structure of two C 5 alkene isomers on their combustion properties, and to highlight the major chemical reactions occurring during their high‐temperature oxidation, water time histories were measured behind reflected shock waves for the oxidation of 1‐pentene (C 5 H 10 ‐1) and 3‐methyl‐1‐butene (3M1B) in 99.5% Ar. The experiments were carried out at three different equivalence ratios ( φ = 0.5, 1.0, and 2.0) at pressures and temperatures ranging from 1.29 to 1.47 atm and 1 331 to 1 877 K, respectively. The H 2 O quantification extends the database for 1‐pentene and provides new insights for 3M1B. These unique results were used to validate and to develop a new detailed kinetics model. Numerical predictions are presented, and the new model was able to capture the results with suitable accuracy, with 3M1B being notably more reactive than C 5 H 10 ‐1. Sensitivity and rate‐of‐production analyses were performed to help explain the results. Under the present conditions, the reactivity is rapidly initiated by molecular dissociation of a fraction of the pentene isomers. The initiation phase then induces H‐atom abstraction by active radicals (H, OH, O, HO 2 , and CH 3 ) to first produce alkenyl C 5 H 9 radicals (or an alkyl radical and an alkenyl radical by breaking a C─C bond) and subsequent, smaller fragments. The difference in terms of reactivity between the isomers is essentially due to the fact that 3M1B has one particularly weak tertiary allylic C─H bond, which allows for fast H‐atom abstraction compared with 1‐pentene.
Abstract not provided.
The ubiquitous in-node heterogeneity of HPC and cloud computing platforms makes software portability and performance optimization extremely challenging. Described here, the MatRIS multilevel math library abstraction framework employs tasking to alleviate these difficulties. MatRIS includes the IRIS task-based runtime on the bottom level and exposes different layers of abstraction to render algorithms architecturally agnostic. MatRIS ensures the decomposition and creation of tasks that represent the necessary encapsulation of the optimized kernels from both vendor and open-source math libraries. Once built, MatRIS can select different combinations of accelerators at runtime, making it portable even on diverse heterogeneous architectures. By leveraging the IRIS runtime’s features for managing heterogeneity, MatRIS deploys algorithms that remove the need to specify orchestration and data transfer. This study describes how the serial task abstraction of a tiled Cholesky factorization is made portable and scalable in the case of multi-device and multi-vendor heterogeneity on a node with NVIDIA and AMD GPUs by using MatRIS. First, we demonstrate that Cholesky in MatRIS provides multi-GPU scalability that offers competitive performance versus cuSolverMG. Then, we present the challenges and opportunities for heterogeneous execution.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
The reversible execution of C/C++ code has been a target of research and engineering for more than a decade as reversible computation has become a central notion in large-scale parallel discrete event simulation (PDES). The simulation models that are implemented for PDES are of increasing complexity and size and require various language features to support abstraction, encapsulation, and composition when building a simulation model. In this paper, we focus on parallel simulation models that are written with user-defined C++ abstractions and abstractions of the C++ Standard Library. We present an approach based on incremental state saving for establishing reversibility of C++ and an evaluation for a kinetic Monte-Carlo simulation implemented in C++. Although a significant runtime overhead is introduced with our technique, it is an enormous win that it allows using the entire C++ language, and has that code automatically transformed into reversible code to enable parallel execution with the Rensselaer’s optimistic simulation system (ROSS).
Abstract Not Provided
Abstract Not Provided
Background: Risk stratification and early detection of cardiac allograft vasculopathy (CAV) is essential in orthotopic heart transplantation (OHT) patients. This study assesses the changes in myocardial blood flow (MBF) noninvasively in OHT patients using quantitative cardiac PET with regadenoson. Methods: Twelve patients (Group 1) (8 males, 4 females, mean age 55 ± 7 years) with no history of post OHT myocardial ischemia were enrolled 5.4 ± 2.0 years after OHT. Fifteen patients (Group 2) (9 males, 6 females, mean age 71 ± 9 years) with intermediate pretest probability but not documented evidence for coronary artery disease (CAD) were also included to serve as control. Global and regional MBFs were assessed using dynamic {sup 13}N-NH{sub 3} PET at rest and during regadenoson-induced hyperemia. The coronary flow reserve (CFR) was also calculated as the ratio of hyperemic to resting MBF. Results: Mean regadenoson-induced rate-pressure products were similar in both groups, while there was an increase in resting rate-pressure product in Group 1 patients. Both mean and median values of resting MBF were higher in Group 1 than Group 2 patients (1.33 ± 0.31 and 1.01 ± 0.21 mL/min/g for Groups 1 and 2, respectively, P < .001), while mean hyperemic MBF values were similar in both Groups (2.68 ± 0.84 and 2.64 ± 0.94 mL/min/g, P = NS) but median hyperemic MBF values were lower in Group 1 than Group 2 patients (2.0 vs. 2.60 mL/min/g, P = .018). Both mean and median CFR values demonstrated a significant reduction for Group 1 compared to Group 2 patients (2.07 ± 0.74 vs 2.63 ± 0.48, P = .025). Conclusions: This study suggests that the MBF in OHT patients may be abnormal at resting state with diminished CFR. This hints that the epicardial and microvascular coronary subsystem may be exacerbated after OHT leading to the gradual progression of CAV. [French] French Abstract: Contexte: Cette étude pilote par tomographie a positrons évalue de manière quantitative les changements de perfusion myocardique et le risque de vasculopathie coronaire après transplantation cardiaque chez l’être humain. Méthodes: Douze patients (groupe 1) (8 hommes, 4 femmes, âge moyen 55 ± 7 ans) sans antécédents d'ischémie myocardique post-chirurgicale ont été étudiés après 5,4 ± 2,0 ans après transplantation cardiaque. Quinze patients (groupe 2) (9 hommes, 6 femmes, âge moyen 71 ± 9 ans) avec une probabilité intermédiaire mais sans signes objectifs de maladie coronarienne ont servi de contrôles. Les donnes de perfusion myocardique globales et régionales ont été évaluées par tomographie à positrons l'aide de{sup 13}N-NH3 au repos et durant l'hyperémie induite par le vasodilatateur coronarien régadénoson. La réserve de flux coronarien a été calculée sur base du rapport entre le flux myocardique hyperhémique induit par le régadénoson et le flux myocardique au repos. Résultats: les double produits (fréquence cardiaque x tension artérielle) moyens après régadénoson furent similaires chez les deux groups de patients. Par contre le double produit au repos était plus élevé dans le groupe de patient transplantés. Les valeurs moyennes et médianes de perfusion myocardique globale au repos ont été calculées à 1.33 ± 0.31 ml/min/g dans le groupe de patients transplantés et 1.01 ± 0.21 ml/min/g dans le groupe control (P < 0.001). Après régadénoson, les valeurs moyennes de perfusion myocardique se sont avérées similaires dans les deux groupes (2,68 ± 0,84 et 2,64 ± 0,94 ml/min/g, P > 0.05). Néanmoins les valeurs médianes se sont avérées inferieures dans le groupe 1 comparativement au groupe control (2,0 versus 2,60 ml/min/g; P = 0,018). Les valeurs moyennes et médianes de réserve de flux myocardique mesurées étaient significativement réduites chez les patient transplantés (2,07 ± 0,74) en comparaison aux patients du groupe 2 (2,63 ± 0,48; P = 0.025). Conclusion: La perfusion myocardique au repos peut s’avérer anormale après transplantation cardiaque et s’accompagner d’une diminution de la réserve du flux coronaire. Cette étude pilote suggère que les vaisseaux épicardiques et la micro-vascularisation du myocarde peuvent être atteints après transplantation et conduire à la maladie coronaire du greffon. [Spanish] Spanish Abstract: Antecedentes: la estratificación de riesgo y detección temprana de la vasculopatía del aloinjerto cardiaco (VAC) es esencial en los pacientes con trasplante cardiaco ortotópico (TCO). El presente estudio evalúa de forma no invasiva los cambios en el flujo sanguíneo miocárdico (FSM) en pacientes con TCO utilizando el PET cardiaco cuantitativo con regadenoson. Métodos: Doce pacientes (Grupo 1) (8 hombres, 4 mujeres, edad promedio 55 ± 7 años) sin historia de isquemia miocárdica posterior al TCO fueron incluidos después de 5.4 ± 2.0 años de ser trasplantados. Quince pacientes (Grupo 2) (9 hombres, 6 mujeres, edad promedio 71 ± 9 años) con probabilidad pre-prueba intermedia pero sin evidencia documentada de enfermedad arterial coronaria (EAC) fueron incluidos como grupo control. El FSM global y regional fueron evaluados utilizando el estudio PET dinámico con {sup 13}N-NH{sub 3} en reposo y durante la inducción de hiperemia con regadenoson. La reserva de flujo coronario (RFC) también fue calculada como la proporción entre el FSM hiperémico y el de reposo. Resultados: el producto de velocidad-presión promedio inducido por regadenoson fue similar en ambos grupos, mientras que existió un incremento de este producto velocidad-presión durante el reposo en el Grupo 1 de pacientes. Los valores de la media y mediana del FSM de reposo fueron mayores en el Grupo 1 que el Grupo 2 de pacientes (1.33 ± 0.31 y 1.01 ± 0.21 mL/min/g para los Grupos 1 y 2, respectivamente, P < 0.001). La media de los valores del FSM hiperémico fueron similares en ambos grupos (2.68 ± 0.84 and 2.64 ± 0.94 mL/min/g, P = NS), sin embargo la mediana fue menor en el Grupo 1 que en el Grupo 2 (2.0 vs. 2.60 mL/min/g, P = .018). Tanto la media como la mediana para los valores de la RFC demostraron una disminución significativa en el Grupo 1 comparada con el Grupo 2 (2.07 ± 0.74 vs. 2.63 ± 0.48, P = 0.025). Conclusiones: El presente estudio sugiere que el FSM en pacientes con TCO puede estar alterado en reposo con una RFC disminuida. Esto indica que los sistemas coronarios epicardico y microvascular pudieran estar inflamados posterior al TCO conduciendo a una progresión gradual de la VAC. [Chinese] Chinese Abstract: 背景: 对于原位心脏移植 (OHT) 病人, 早期检测移植心脏血管病变 (CAV) 和进行危险分层是必要的。 本研究拟通过类伽腺苷定 心脏 PET 显像, 非侵入性地评估 OHT 病人心肌血流 (MBF) 的变化。 方法: 研究对象分为两组。 第一组, 12个病人 (8 男, 4女, 平均 55 ± 7岁), OHT 后 5.4 ± 2.0 年, 没有 OHT 后心肌缺血。 第二组 (对照组), 15 个病人 (9 男, 6 女, 平均 71 ± 9 岁), 中等冠心病可能, 但尚未确诊。 分别于静息及类伽腺苷药物负荷下, 动态采集 {sup 13}N-NH{sub 3} PET 图像, 获得整体和局部 MBF。冠脉血流储备 (CFR) 通过负荷 MBF /静息 MBF 计算而得。 结果: 类伽腺苷负荷时, 反映心肌耗氧 的心率血压乘积在两组间没有差异, 但在静息时, 第一组明显高于第二组。静息时, 第一组 MBF 的平均值高于第二组 (1.33 ± 0.31 vs. 1.01 ± 0.21 mL/min/g, P < 0.001); 负荷时, 两组 MBF 的平均值无差异 (2.68 ± 0.84 vs. 2.64 ± 0.94 mL/min/g, P = NS), 但 MBF 的中位数第一组要低于第二组 (2.0 vs. 2.60 mL/min/g, P = 0.018), 且第一组 CFR 的平均值明显低于第二组 (2.07 ± 0.74 vs. 2.63 ± 0.48, P = 0.025)。 结论: 在原位心脏移植病人中, 冠脉血流储备以及静息心肌血流 均呈现明显异常。提示原位心脏移植后, 冠状动脉心外膜血管与微小血管功能均受损, 进而将逐渐导致移植心脏血管病变。 关键词: 动态PET, 类伽腺苷, 冠状动脉血流储备, 原位心脏移植, 移植心脏血管病变。.
At the European Society of Cardiology (ESC) congress of this year 2018, held in Munich from August 25th to 29th, 4594 abstracts were presented. Of those, 423 (10.8%) belonged to an imaging category. Experts in echocardiography (VD), cardiovascular magnetic resonance (CMR) (CBD), nuclear imaging (OG), and cardiac computed tomography (CT) (PMH) have selected the abstracts in their areas of expertise that were of most interest to them and are summarized in this bird’s eye view from this ESC meeting. These abstracts were integrated by one of the Editors of the Journal (JB).