Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Liquid helium fluid dynamics studies. Final Technical Report

Future high energy physics accelerators depend on a number of advanced technologies to open the many doors of scientific discovery. Among these advanced technologies, superconducting magnets and superconducting radio frequency (SRF) cavities are the backbone of the accelerator and detector systems. But all these low temperature systems depend critically on successful and reliable operation of their supporting technologies, among which the liquid helium cooling system is of the utmost importance. To improve the quality of these systems both in terms of efficiency and reliability, a robust helium cryogenics research and development (R&D) effort is required. The proposed research to be conducted by the FSU cryogenics group aims to produce fundamental knowledge that meets this R&D need. The projects that we have completed over the past grant period at Florida State University consist of experimental research on liquid helium fluid dynamics and heat transfer problems relevant to the development of future superconducting particle physics accelerators. Liquid helium is the coolant used in all such facilities and in many of these facilities He II (the low temperature phase of liquid helium also known as superfluid helium) is preferred due to its outstanding heat transfer characteristics. The work consists of two main experimental studies that probe both fundamental as well as practical aspects of liquid helium cooling. The first is a broad and fundamental study of the heat and mass transfer processes that can occur during a sudden catastrophic loss of vacuum (SCLV) incident in a superconducting accelerator. SCLV refers to the remote but extremely critical accident scenario where atmospheric pressure air is allowed to flood into the insulating vacuum system and impinge on the liquid helium cooled surfaces in the accelerator. Safe performance and recovery from such accidents is essential to the reliable operation of superconducting accelerators. The dynamics of this process is quite complex and so our approach is to conduct a series of well-orchestrated experiments that probe the various physical phenomena that can occur during an SCLV event. The experiments are coupled with analytic and numerical analysis in an effort to develop a general understanding of the process and to assist with future accelerator design and development. The second activity is directed toward fundamental understanding of heat and mass transfer in He II, which is essential to the design of superconducting magnets and radio frequency cavities in accelerators. The work consists of flow visualization of the dynamics of He II using laser assisted techniques. Two complementary techniques are used to study the fundamentals of the turbulent state. The first technique uses neutrally buoyant solid hydrogen particles to probe the flow fields of the superfluid and normal fluid components. The other technique uses laser excited He2* molecules as tracers of the normal fluid motion within the He II. The activities also included an effort to use visualization techniques to locate transient hot spots in radio frequency superconducting cavities. Such work provides valuable information about the heat transfer process in He II and its impact on the performance of superconducting devices. The research effort at Florida State University is not directly in support of a specific high energy physics experiment or facility. Rather, the work is general and coordinated with HEP accelerator laboratories to provide valuable insight that can assist with future accelerator development.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

History of gradient advances in SRF

Radio frequency (RF) superconductivity has become a key technology for many modern particle accelerators. One of its most salient features of this technology is the ability of superconducting RF cavities to deliver high accelerating gradients in continuous-wave and long-pulse modes of operation. However, reaching the current state of the technology was not an easy fit. Over many years scientists and engineers had to overcome several serous performance limitations. In this paper, I attempt to the best of my knowledge to trace the history of accelerating gradients evolution in the field of superconducting radio frequency. I will restrict the scope to primary innovations along with some of the ensuing developments in developing cavities made of bulk niobium. But I will not cover all the many applications and findings over the subsequent decades of progress that were based on the primary discoveries and inventions. I will also not cover a number of other important topics in the history of cavity developments, such as the drive for higher Q values, or the push for lower cavity costs via Nb/Cu cavities or large grain Nb cavities.

43 PARTICLE ACCELERATORS↗

A New First-Principles Calculation of Field-Dependent RF Surface Impedance of BCS Superconductor

There is a need to understand the intrinsic limit of radiofrequency (RF) surface impedance that determines the performance of superconducting RF cavities in particle accelerators. Here we present a field-dependent derivation of Mattis-Bardeen theory of the RF surface impedance of BCS superconductors based on the shifted density of states resulting from coherently moving Cooper pairs. Our theoretical prediction of the effective BCS RF surface resistance (Rs) of niobium as a function of peak surface magnetic field amplitude agrees well with recently reported record low loss resonant cavity measurements from JLab and FNAL with carefully, yet differently, prepared niobium material. The surprising reduction in resistance with increasing field is explained to be an intrinsic effect.

43 PARTICLE ACCELERATORS↗

Results from sudden loss of vacuum on scaled superconducting radio frequency cryomodule experiment

Superconducting radio frequency (SRF) cavities for particle accelerators are at risk of failure due to sudden loss of vacuum (SLV) adjacent to liquid helium (LHe) spaces. To better understand this failure mode and its associated risks an experiment is designed to test the longitudinal effects of SLV within the beam tube of a scaled SRF cryomodule that has considerable length relative to beam tube cross section. The scaled cryomodule consists of six individual SRF cavities each roughly 350 mm long, initially cooled to 2 K by a superfluid helium bath and a beam tube pumped to vacuum. A fast-acting solenoid valve is used to simulate SLV on the beam tube, from which point it takes over 3 s for the beam tube pressure to equalize with atmosphere, and 30 s for the helium space to reach the relief pressure of 4 bara. A SLV longitudinal effect in the beam tube is evident in both pressure and temperature data, but interestingly the temperatures responds more quickly to SLV than do the pressures. It takes 500 ms (roughly 100 ms per cavity) for the far end of the 2 m long beam tube to respond to a pressure increase compared to 300 ms for temperature (approximately 50 ms per cavity). The paper expands upon these and other results to better understand the longitudinal effect for SRF cryomodules due to SLV.

43 PARTICLE ACCELERATORS↗

Conduction Cooling of a Niobium SRF Cavity Using a Cryocooler

Superconducting Radio Frequency (SRF) cavities are the primary choice for accelerating charged particles in high-energy research accelerators. Institutions like Fermilab use SRF cavities because they enable significantly higher gradients and quality factors than normal-conducting RF cavities and DC voltage cavities. To cool the SRF cavities to low temperatures (typically around 2 K), liquid helium refrigerators are used. Producing and maintaining the necessary liquid helium requires large, elaborate cryogenic plants involving dewars, compressors, expansion engines, and recyclers. The cost, complexity, and space required for such plants is part of the reason that industry has not yet adopted SRF-based accelerators. At the Illinois Accelerator Research Center (IARC) at Fermilab, our team seeks to make SRF technology accessible not only to large research accelerators, but to industry as well. If we eliminate the complexity associated with liquid helium plants, SRF-based industrial accelerators may finally become a reality. One way to do this is to eliminate the use of liquid helium baths altogether and develop a brand-new cooling technique for SRF cavities: conduction cooling using a cryocooler. Recent advances in SRF technology have made it possible to operate SRF cavities at 4 K, a temperature easily achievable using commercial cryocoolers. Our IARC team is taking advantage of this technology to cool SRF cavities.

43 PARTICLE ACCELERATORS↗

Current Dosing Paradigm for Stereotactic Radiosurgery Alone After Surgical Resection of Brain Metastases Needs to Be Optimized for Improved Local Control

Purpose: To describe the use of radiosurgery (RS) alone to the resection cavity after resection of brain metastases as an alternative to adjuvant whole-brain radiotherapy (WBRT). Methods and Materials: Sixty-two patients with 64 cavities were treated with linear accelerator-based RS alone to the resection cavity after surgical removal of brain metastases between March 2007 and August 2010. Fifty-two patients (81%) had a gross total resection. Median cavity volume was 8.5 cm{sup 3}. Forty-four patients (71%) had a single metastasis. Median marginal and maximum doses were 18 Gy and 20.4 Gy, respectively. Sixty-one cavities (95%) had gross tumor volume to planning target volume expansion of {>=}1 mm. Results: Six-month and 1-year actuarial local recurrence rates were 14% and 22%, respectively, with a median follow-up period of 9.7 months. Six-month and 1-year actuarial distant brain recurrence, total intracranial recurrence, and freedom from WBRT rates were 31% and 51%, 41% and 63%, and 91% and 74%, respectively. The symptomatic cavity radiation necrosis rate was 8%, with 2 patients (3%) undergoing surgery. Of the 11 local failures, 8 were in-field, 1 was marginal, and 2 were both (defined as in-field if {>=}90% of recurrence within the prescription isodose and marginal if {>=}90% outside of the prescription isodose). Conclusions: The high rate of in-field cavity failure suggests that geographic misses with highly conformal RS are not a major contributor to local recurrence. The current dosing regimen derived from Radiation Therapy Oncology Group protocol 90-05 should be optimized in this patient population before any direct comparison with WBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659↗

A multi-layered SRF cavity for conduction cooling applications

Industrial application of SRF technology would favor the use of cryocoolers to conductively cool SRF cavities for particle accelerators, operating at or above 4.3 K. In order to achieve a lower surface resistance than Nb at 4.3 K, a superconductor with higher critical temperature should be used, whereas a metal with higher thermal conductivity than Nb should be used to conduct the heat to the cryocoolers. A standard 1.5 GHz bulk Nb single-cell cavity has been coated with a ~2 µm thick layer of Nb3Sn on the inner surface and with a 5 mm thick Cu layer on the outer surface for conduction cooled applications. The cavity performance has been measured at 4.3 K and 2.0 K in liquid He. The cavity reached a peak surface magnetic field of ~40 mT with a quality factor of 6×109 and 3.5×109 at 4.3 K, before and after applying the thick Cu layer, respectively.

Ciovati, G.↗

Machine Learning Based Cavity Fault Classification and Prediction

We report on the development of machine learning models for classifying C100 superconducting radio frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a continuous-wave recirculating linac utilizing 418 SRF cavities to accelerate electrons up to 12 GeV through 5-passes. Of these, 96 cavities (12 cryomodules) are designed with a digital low-level RF system configured such that a cavity fault triggers waveform recordings of 17 RF signals for each of the eight cavities in the cryomodule. Subject matter experts (SME) can analyze the collected time-series data, identify which of the eight cavities faulted first, and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the ML models during a recent physics run.

43 PARTICLE ACCELERATORS↗

RF BREAKDOWN STUDIES USING PRESSURIZED CAVITIES

Many present and future particle accelerators are limited by the maximum electric gradient and peak surface fields that can be realized in RF cavities. Despite considerable effort, a comprehensive theory of RF breakdown has not been achieved and mitigation techniques to improve practical maximum accelerating gradients have had only limited success. Part of the problem is that RF breakdown in an evacuated cavity involves a complex mixture of effects, which include the geometry, metallurgy, and surface preparation of the accelerating structures and the make-up and pressure of the residual gas in which plasmas form. Studies showed that high gradients can be achieved quickly in 805 MHz RF cavities pressurized with dense hydrogen gas, as needed for muon cooling channels, without the need for long conditioning times, even in the presence of strong external magnetic fields. This positive result was expected because the dense gas can practically eliminate dark currents and multipacting. In this project we used this high pressure technique to suppress effects of residual vacuum and geometry that are found in evacuated cavities in order to isolate and study the role of the metallic surfaces in RF cavity breakdown as a function of magnetic field, frequency, and surface preparation. One of the interesting and useful outcomes of this project was the unanticipated collaborations with LANL and Fermilab that led to new insights as to the operation of evacuated normal-conducting RF cavities in high external magnetic fields. Other accomplishments included: (1) RF breakdown experiments to test the effects of SF6 dopant in H2 and He gases with Sn, Al, and Cu electrodes were carried out in an 805 MHz cavity and compared to calculations and computer simulations. The heavy corrosion caused by the SF6 components led to the suggestion that a small admixture of oxygen, instead of SF6, to the hydrogen would allow the same advantages without the corrosion in a practical muon beam line. (2) A 1.3 GHz RF test cell capable of operating both at high pressure and in vacuum with replaceable electrodes was designed, built, and power tested in preparation for testing the frequency and geometry effects of RF breakdown at Argonne National Lab. At the time of this report this cavity is still waiting for the 1.3 GHz klystron to be available at the Wakefield Test Facility. (3) Under a contract with Los Alamos National Lab, an 805 MHz RF test cavity, known as the All-Seasons Cavity (ASC), was designed and built by Muons, Inc. to operate either at high pressure or under vacuum. The LANL project to use the (ASC) was cancelled and the testing of the cavity has been continued under the grant reported on here using the Fermilab Mucool Test Area (MTA). The ASC is a true pillbox cavity that has performed under vacuum in high external magnetic field better than any other and has demonstrated that the high required accelerating gradients for many muon cooling beam line designs are possible. (4) Under ongoing support from the Muon Acceleration Program, microscopic surface analysis and computer simulations have been used to develop models of RF breakdown that apply to both pressurized and vacuum cavities. The understanding of RF breakdown will lead to better designs of RF cavities for many applications. An increase in the operating accelerating gradient, improved reliability and shorter conditioning times can generate very significant cost savings in many accelerator projects.

43 PARTICLE ACCELERATORS↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in super-conducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, S. A.K. [Fermilab] (ORCID:000000028765↗

SU-E-T-93: Creation of Standardized APBI SAVI Cavities Using CT Registration

Purpose: Develop a consistent and rapid method of generating the initial cavity structure for Accelerated Partial Breast Irradiation (APBI) using the SAVI applicator. Methods: Four SAVI (Cianna Medical) applicators (6-1 Mini, 6-1, 8-1, and 10-1) were scanned on a CT simulator. The applicators were scanned in air with the CT slices (0.625mm axial thickness) perpendicular to the long axis of the applicator. Following scanning the CT images were transferred to Eclipse (Varian Medical Systems) and contours of the cavity were drawn. The cavity proximal and distal locations were defined according to MD specification. The scans and contours were then re-imported into the CT virtual simulation workstation.At the time of patient planning the appropriate applicator scan is anonymized and imported into Eclipse. In Brachytherapy Planning two Marker points are placed, one at the distal band location (cavity start) and the second at a defined distance along the applicator (cavity end). The actual patient scan is then registered to the applicator scan. A three point match is used to quickly get the two scans in approximate alignment. Manually matching is then used to fine tune the alignment of the cavity contour and Marker points. Results: The standard applicator scans have shown to agree well with the applicators in the patient scans. The time taken to register the scans has shown to be less than generating the cavities using the standard methods of contouring on the axial slices or using the dose shaper with sources in the central channel. Conclusion: The registration of a standard applicator scan and contour has improved the consistency in the generation of the initial cavity (SAVI) structure. Planning structures used for dose calculation are created with that structure as a starting point so accuracy and consistency are important for dose evaluation and plan comparison.

60 APPLIED LIFE SCIENCES↗

Nitrogen-doped 9-cell cavity performance in a test cryomodule for LCLS-II

The superconducting RF linac for Linac Coherent Light Source-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q{sub 0} of 2.7 × 10{sup 10} at 2.0 K and 16 MV/m accelerating gradient. Two niobium 9 cell cavities, prepared with nitrogen-doping at Fermilab, were assembled into the Cornell Horizontal Test Cryomodule (HTC) to test cavity performance in a cryomodule that is very similar to a full LCLS-II cryomodule. The cavities met LCLS-II specifications with an average quench field of 17 MV/m and an average Q{sub 0} of 3 × 10{sup 10}. The sensitivity of the cavities' residual resistance to ambient magnetic field was determined to be 0.5 nΩ/mG during fast cool down. In two cool downs, a heater attached to one of the cavity beam tubes was used to induce large horizontal temperature gradients. Here, we report on the results of these first tests of nitrogen-doped cavities in a cryomodule, which provide critical information for the LCLS-II project.

43 PARTICLE ACCELERATORS↗

Useful formulas for non-magnetized electron cooling

Recent success of Low Energy RHIC Electron Cooler (LEReC) opened a road for development of high energy electron coolers based on non-magnetized electron bunches accelerated by RF cavities. Electrons in such coolers can have velocity distribution with various unequal horizontal, vertical and longitudinal velocity spreads. In this paper we revisit a formula of friction force in non-magnetized cooling and derive a number of useful expressions for different limiting cases.

43 PARTICLE ACCELERATORS↗

Cylindrical Magnetron Development for Nb3sn Deposition via Magnetron Sputtering

Due to its better superconducting properties (critical temperature Tc~ 18.3 K, superheating field Hsh~ 400 mT), Nb₃Sn is considered as a potential alternative to niobium (Tc~ 9.25 K, Hsh~ 200 mT) for superconducting radiofrequency (SRF) cavities for particle acceleration. Magnetron sputtering is an effective method to produce superconducting Nb₃Sn films. We deposited superconducting Nb₃Sn films on samples with magnetron sputtering using co-sputtering, sequential sputtering, and sputtering from a stoichiometric target. Nb₃Sn films produced by magnetron sputtering in our previous experiments have achieved DC superconducting critical temperature up to 17.93 K and RF superconducting transition at 17.2 K. A magnetron sputtering system with two identical cylindrical cathodes that can be used to sputter Nb₃Sn films on cavities has been designed and is under development now. We report on the design and the current progress on the development of the system.

43 PARTICLE ACCELERATORS↗