Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Three dimensional intensity modulated brachytherapy (IMBT): Dosimetry algorithm and inverse treatment planning

Purpose: The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. Methods: A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a ''modified TG-43'' (mTG-43) dose calculation formalism for IMBT dosimetry; and (3) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an ''isotropic plan'' with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. Results: IMBT approaches showed superior plan quality compared to the original plans and the isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V{sub 200} by 16.1% and 4.8%, respectively, compared to the original and the isotropic plans. The conformity index for the target was increased by 0.13 and 0.04, respectively. The maximum dose to the skin was reduced by 56 and 28 cGy, respectively, per fraction. Also, the maximum dose to the ribs was reduced by 104 and 96 cGy, respectively, per fraction. The mean dose to the ipsilateral and contralateral breasts and lungs were also slightly reduced by the IMBT plan. The limitations of IMBT are the longer planning and delivery time. The IMBT plan took around 2 h to optimize, while the isotropic plan optimization could reach the global minimum within 5 min. The delivery time for the IMBT plan is typically four to six times longer than the corresponding isotropic plan. Conclusions: In this study, a dosimetry method for IMBT sources was proposed and an inverse treatment planning system prototype for IMBT was developed. The improvement of plan quality by 3D IMBT was demonstrated using ten APBI case studies. Faster computers and higher output of the source can further reduce plan optimization and delivery time, respectively.

60 APPLIED LIFE SCIENCES↗

High-energy protons from submicron-sized targets

Improving of intensity contrast ratio of intense short laser pulses is making it possible to use submicron-sized targets, both spherical and plane, in the interest of proton acceleration for different applications. The way of improving of the ion beam quality is utilization of targets with two ion species - heavy ions (majority) and light ions, e.g. protons, (minority). Two different approaches, analytical theory and particle-in-cell simulations (PIC) are presented for studying the characteristics of laser-triggered ions due to the Coulomb-like mechanism of particle acceleration from submicron-sized targets. The comparative analysis of explosions of heterogeneous (layered) and homogeneously mixed targets for production of best quality ion bunches has been performed. We also found the regime of anisotropic proton acceleration from spherical targets with light and heavy ions relevant to the experiments with submicron-diameter droplets from water spray target irradiated by an ultrashort intense laser pulse.

43 PARTICLE ACCELERATORS↗

Multi-objective optimization with an integrated electromagnetics and beam dynamics workflow

In particle accelerators, RF cavities are used to accelerate charged particle beams to designed high energy for physical applications. In a typical accelerator design, the optimization of RF cavities and the optimization of beam dynamics are carried out in separate studies. For a more general and unrestricted accelerator design, a coupled optimization of the RF cavities and the beam parameters is required. For this coupled optimization problem, we have developed an integrated electromagnetics and beam dynamics workflow management system. Within this system, the geometries for a set of cavity components are first adjusted; the field modes are then computed with an electromagnetics program, and imported into a beam dynamics program for beam dynamics simulation. This workflow is encapsulated into a parallel multi-objective optimizer to achieve the integrated accelerator design optimization. A multi fidelity strategy is developed to improve the speed of the optimizer. Furthermore, this integrated global optimization capability is illustrated using a photoinjector design example and yields an improved design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cryogenically cooled high voltage DC photoemission electron source

Linear electron accelerators and their applications such as ultrafast electron diffraction require compact high-brightness electron sources with high voltage and electric field at the photocathode to maximize the electron density and minimize space-charge induced emittance growth. Achieving high brightness from a compact source is a challenging task because it involves an often-conflicting interplay between various requirements imposed by photoemission, acceleration, and beam dynamics. Here we present a new design for a compact high voltage DC electron gun with a novel cryogenic photocathode system and report on its construction and commissioning process. This photoemission gun can operate at ~200 kV at both room temperature and cryogenic temperature with a corresponding electric field of 10 MV/m, necessary for achieving high quality electron beams without requiring the complexity of guns, e.g., based on RF superconductivity. Furthermore, it hosts a compact photocathode plug compatible with that used in several other laboratories opening the possibility of generating and characterizing electron beam from photocathodes developed at other institutions.

47 OTHER INSTRUMENTATION↗

Tunable Plasma Linearizer for Compensation of Nonlinear Energy Chirp

The removal of undesired nonlinear time-energy correlation (energy chirp) present in relativistic electron beams is crucial for many accelerator-based scientific applications, such as free-electron lasers, high-energy electron radiography, and MeV ultrafast electron microscopy. Here, we propose and demonstrate that a low-density plasma section can be used as a passive “linearizer” to significantly compensate for the nonlinear energy chirp imprinted on a beam by the curvature of the radio-frequency field in a conventional accelerator. Physically, the passage of the beam through the plasma excites a strong quasi-cosinoidal longitudinal decelerating wakefield that acts to mitigate the beam’s nonlinear energy chirp by superimposing a reverse chirp on the beam. Time-resolved phase-space measurements, combined with high-fidelity three-dimensional particle-in-cell simulations show that the longitudinal phase space of the beam core is almost completely linearized, leading to a fourfold reduction of the beam overall energy spread from 0.148% to 0.036% (FWHM).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proceedings of the 1998 International Computational Accelerator Physics Conference

The 1998 International Computational Accelerator Physics Conference, ICAP’98, was held September 14-18, 1998, at the Monterey Convention Center in Monterey, California. The meeting continued the tradition of four earlier Computational Accelerator Physics conferences, held in La Jolla, California (1988), Los Alamos, New Mexico (1990), Pleasanton, California (1993), and Williamsburg, Virginia (1996). ICAP’98 was organized by the Stanford Linear Accelerator Center (SLAC), Los Alamos National Laboratory (LANL), and the National Energy Research Scientific Computing Center (NERSC), and received support from the U.S. Department of Energy. The aim of this conference series is to discuss recent advances in Computational Accelerator Physics and their applications to solving important problems related to present and future accelerators. The ICAP’98 program included plenary sessions on modeling challenges in next-generation accelerators, state-of-the art methods in computational accelerator physics, and a view of what high-end computing would be like in the 21st century. There were also focused sessions on accelerator design and control, modeling high intensity beam phenomena, electromagnetic modeling, advanced algorithms, software environments and libraries, visualization and graphic interfaces, modeling advanced accelerator concepts, modeling the beam-beam interaction, computing wakefields, and combined particle/field simulations. In addition to these oral sessions there was a poster session and a vendor display. Prior to the start of the technical program, a half-day tutorial on High Performance Computing was hosted by NERSC. The ICAP series recognizes that computing and, in particular, advanced computing, is playing an increasingly important role in the successful design and development of major accelerator facilities, and in research and development leading to advances in accelerator technology. We expect that this new emphasis on high-end computing will continue in future ICAP conferences.

Ko, Kwok↗

Radiation from charges in the continuum limit

It is known that an accelerating charge radiates according to Larmor formula. On the other hand, any DC current following a curvilinear path, consists of accelerating charges, but in such case the radiated power is 0. The scope of this paper is to analyze and quantify how a system of charges goes from a radiating state to a non radiating state when the charges distribution goes to the continuum limit. Understanding this is important from the theoretical point of view and the results of this work are applicable to particle accelerator, cyclotron and other high energy devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opportunities and challenges in cathode development for non-lithium-ion batteries

Lithium (Li)-ion batteries have stimulated the societal transformation to clean energy systems. This carry-on electricity is revolutionizing how society communicates, functions, and evolves efficiently by enabling mobile electronics, zero-emission electric vehicles, and stationary energy storage. In preparation for the sustainable energy future, however, there are growing concerns about depleting critical elements used in the Li technology (e.g., lithium, cobalt, and nickel), especially for large-scale applications that will accelerate the rate of elemental consumption. Various non-Li-based rechargeable batteries composed of earth-abundant elements, such as sodium, potassium, magnesium, and calcium, have been proposed and explored as alternative systems to promote sustainable development of energy storage. In this perspective, we discuss challenges in Li-ion batteries in the sustainability aspect and provide our opinions on the potential applications of non-Li-based batteries. We also highlight the current status, important progress, and remaining challenges of the Li-alternative technologies.

25 ENERGY STORAGE↗

Automated Generation of Integrated Digital and Spiking Neuromorphic Machine Learning Accelerators

The growing numbers of application areas for artificial intelligence (AI) methods have led to an explosion of domain-specific accelerators that could support every new machine learning (ML) algorithm advancement, clearly highlighting the need for a capability to quickly and automatically transition from algorithm definition to hardware implementation and explore design space along a variety of SWaP (size, weight and Power). The software defined architectures (SODA) synthesizer implements a compiler-based modular infrastructure for the end-to-end generation of machine learning accelerators from high-level frameworks to hardware description language. At the same time, neuromorphic computing, by mimicking how the brain operates, promises to perform artificial intelligence tasks at efficiencies orders of magnitude higher than the current conventional tensor-processing based accelerators, as demonstrated by a variety of specialized designs leveraging Spiking Neural Networks (SNNs). Nevertheless, the mapping of an artificial neural network (ANN) to solutions supporting SNNs is still a non-trivial and very device-specific task, and completely lack the possibility to design hybrid systems that integrate conventional and spiking neural models. In this paper we discuss the support for such an integrated generation leveraging the SODA Synthesizer framework and its modular structure. In particular, we present a new MLIR dialect (part of the SODA frontend) that allows expressing spiking neural network features (e.g., available resources, spiking sequences, analog signal reading, etc.) and illustrate how it enables mapping to Spiking Neurons and deployment to the related specialized hardware (which, in the digital domain, could be generated through the other existing layers of the SODA Synthesizer). We then discuss the opportunities for even deeper integration afforded by the hardware compilation infrastructure, providing a path towards the generation of complex heterogeneous artificial intelligence systems.

Curzel, Serena↗

Monte Carlo Simulation of Massive Absorbers for Cryogenic Calorimeters

There is a growing interest in cryogenic calorimeters with macroscopic absorbers for applications such as dark matter direct detection and rare event search experiments. The physics of energy transport in calorimeters with absorber masses exceeding several grams is made complex by the anisotropic nature of the absorber crystals as well as the changing mean free paths as phonons decay to progressively lower energies. We present a Monte Carlo model capable of simulating anisotropic phonon transport in cryogenic crystals. We have initiated the validation process and discuss the level of agreement between our simulation and experimental results reported in the literature, focusing on heat pulse propagation in germanium. The simulation framework is implemented using Geant4, a toolkit originally developed for high-energy physics Monte Carlo simulations. Geant4 has also been used for nuclear and accelerator physics, and applications in medical and space sciences. We believe that our current work may open up new avenues for applications in material science and condensed matter physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R & D on Very-High-Current Superconducting Proton Linac, Final Report

The aim of this R&D project was to develop a superconducting cavity for a very-­ high-current proton accelerator. The particular application motivating the proposal was a LHC upgrade called the Superconducting Proton Linac, or SPL. Under the grant awarded to Stony Brook University the cavity was designed, a prototype copper cavity, followed by the niobium cavity, were built. A new set of HOM dampers was developed. The cavity has outstanding RF performance parameters – low surface fields, low power loss and all HOMs are fully damped. In fact, it is a “universal cavity” in the sense that it is suited for the acceleration of high-­current protons and well as high current electrons. Its damping of HOM modes is so good that it can see service in a multi-pass linac or an Energy Recovery Linac in addition to the easier service in a single-pass linac. Extensive measurements were made on the cavities and couplers, with the exception of the cold test of the niobium cavity. At the time of this report the cavity has been chemically processed and is ready for vertical testing which will be carried out shortly.

43 PARTICLE ACCELERATORS↗

The new RF sources for accelerators

Several new RF sources are being developed for accelerator and collider applications. Assembly is nearing completion of a multiple beam inductive output tube at 352 MHz. An annular beam klystron is being developed to produce 10 MW pulses at 1.3 GHz. The annular beam approach provides significant cost reduction over similar multiple beam devices. Fabrication is underway on a 10 kW, periodic permanent magnet klystron at 2.815 GHz. Permanent magnets eliminate the solenoid and associated power supplies and cooling requirements to reduce operational cost. Investigations are beginning on a novel approach for driving accelerator cavities using pulse shaping to increase coupling efficiency and dramatically reduce RF power requirements.

43 PARTICLE ACCELERATORS↗

Jefferson Lab IEC 61508/61511 Safety PLC Based Safety System

This paper describes the design of the new 12 GeV Upgrade Personnel Safety System (PSS) at the Thomas Jefferson National Accelerator Facility (TJNAF). The new PSS design is based on the implementation of systems designed to meet international standards IEC61508 and IEC 61511 for programmable safety systems. In order to meet the IEC standards, TJNAF engineers evaluated several SIL 3 Safety PLCs before deciding on an optimal architecture. In addition to hardware considerations, software quality standards and practices must also be considered. Finally, we will discuss R&D that may lead to both high safety reliability and high machine availability that may be applicable to future accelerators such as the ILC. Key words: PLC, Safety, TJNAF, SIL, PSS, PPS, Software, ILC Notice: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes.

43 PARTICLE ACCELERATORS↗

Laser–solid interaction studies enabled by the new capabilities of the iP2 BELLA PW beamline

The new capabilities of the short focal length, high intensity beamline, named iP2, at the BELLA Center will extend the reach of research in high energy density science, including accessing new regimes of high gradient ion acceleration and their applications. This 1 Hz system will provide an on-target peak intensity beyond 1021 W/cm2 with a temporal contrast ratio of <10−14 that will be enabled by the addition of an on-demand double plasma mirror setup. An overview of the beamline design and the main available diagnostics are presented in this paper as well as a selection of accessible research areas. As a demonstration of the iP2 beamline's capabilities, we present 3D particle-in-cell simulations of ion acceleration in the magnetic vortex acceleration regime. The simulations were performed with pure hydrogen targets and multi-species targets. Proton beams with energy up to 125 MeV and an approximately 12° full angle emission are observed as preplasma scale length and target tilt are varied. The number of accelerated protons is on the order of 109/MeV/sr for energies above 60 MeV.

Hakimi, Sahel (ORCID:000000022493564X)↗

Monte Carlo simulations and radiation dosimetry measurements of peripherally applied HDR {sup 192}Ir breast brachytherapy D-shaped applicators

Conformal dose coverage for accelerated partial breast irradiation or radiotherapy boost can be obtained with AccuBoost registered D-shaped brachytherapy applicators using a flattened surface positioned near the patient. Three D-shaped applicators (D45/D53/D60) were dosimetrically characterized using Monte Carlo methods (MCNP5), air ionization chambers (Farmer and Markus), and radiochromic film (GafChromic EBT) in polystyrene and ICRU 44 breast tissue. HDR {sup 192}Ir source dwell times were either constant or optimized to improve skin dose uniformity. Scatter dose decreased as depth decreased. 10 mm beyond the applicator aperture, dose reductions of 90% and 51% were observed at depths of 0 and 30 mm, respectively. Similarly, planar dose uniformity improved as depth decreased and was also due to scatter and applicator geometry. Dose uniformity inside the applicator aperture was approximately 11% and 15% for all three applicators at the skin and 30 mm deep, respectively. Depth dose measurements in polystyrene using ion chamber and radiochromic film agreed with Monte Carlo results within 2%. Discrepancies between film and Monte Carlo dose profiles at 30 mm depth were within 1%.

61 RADIATION PROTECTION AND DOSIMETRY↗