Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Single Event Transients Induced by Picosecond Pulsed X-Ray Absorption in III-V Heterojunction Transistors

We perform measurements which show that focused, picosecond pulses of x-rays can be used to generate single event transients (SET) in a GaAs heterostructure field effect transistor (HFET) and a GaN high electron mobility transistor. X-ray pulses with photon energies of 8, 10 and 12 keV from the Advanced Photon Source at Argonne National Laboratory were used to excite transients. SETs are observed when x-ray pulses are incident upon metal layers above sensitive areas on the transistors. We use focused ion beam (FIB) cross-sectioning and scanning transmission electron microscopy energy dispersive x-ray spectroscopy (STEM-EDXS) to determine the compositional structure of the devices. We present a first order analysis of energy deposition in the devices and correlate it to the transient response to make preliminary interpretations of the results. We compare the x-ray transients from the GaAs HFET with transients generated by 750 nm and 870 nm femtosecond laser pulses. We also present results on the total dose susceptibility of the GaN HEMTs.

Cardoza, David M↗

In‐situ measurements of lattice expansion related to defect generation during flash sintering

Abstract We report results from in‐situ measurements of lattice expansion during flash sintering of 3 mol% yttria stabilized tetragonal zirconia taken at the Advanced Photon Source, Argonne National Laboratory. The expansion is anisotropic, with the relative expansion of the a ‐lattice constant exceeding that of the c ‐lattice constant. The anisotropic expansion cannot be explained by thermal expansion and is consistent with predictions from ab‐initio calculations based upon the generation of vacancy‐interstitial pairs of zirconium and oxygen.

Lebrun, J. ‐M.↗

X-Ray Phase Contrast Imaging of Liquid Film and Spray Development Inside an Aircraft Engine Swirler

Modern aircraft engines combine liquid fuel and air using an intricate flow device with many fuel and air flow passages. To date, the process by which the fuel atomizes within this swirler set has not been examined directly due to optical access limitations. In this work, high-speed X-ray phase-contrast imaging of a liquid spray inside a gas turbine engine swirler geometry is presented. Measurements were carried out at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory using the high-energy broadband X-ray beam. The synchrotron X-ray source provides the necessary photon energy and flux to capture time-resolved fluid phenomena within the confines of the relevant geometry while liquid and air are flowing. Spray nozzle hardware and geometries were provided by the National Jet Fuels Combustion Program (NJFCP), allowing for characterization of the spray using a commercially relevant configuration. Modified swirlers were three-dimensional printed with acrylic to improve imaging access while maintaining influential internal features. Water was used as a surrogate fluid for these studies to demonstrate the visualization capabilities. The experiments were conducted at atmospheric exit pressure conditions with a pressure drop of 6% across the swirler. High-speed imaging of the pilot spray cone revealed sheet breakup several millimeters downstream of the orifice exit, upon interaction with the radial assist air flow. These droplets and ligaments were observed to impinge on the inner filming surface of the swirler and flow toward the exit while developing a tangential flow. Under these conditions, the liquid film grows up to several hundred microns in thickness on the filming surface, and subsequently forms ligaments up to several millimeters in length before breaking up. This work demonstrates the capability of X-ray diagnostics in visualizing liquid flows within solid geometries of technical relevance. Furthermore, the spatial quantification of filming flows and liquid interaction with the swirler air provides validation data for modeling of the multiphase flows and surface interactions within the swirler.

Sforzo, Brandon A.↗

Measurements of the Flow in the Vicinity of an Additively Manufactured Turbine Leading-Edge Using X-Ray Particle Tracking Velocimetry

X-ray particle tracking velocimetry (PTV) is performed, for the first time, to measure the velocity field inside a leading-edge of a turbine blade made by laser-additive-manufacturing (LAM) process. The traditional showerhead holes were replaced by a porous matrix in the leading-edge. The flow through such a leading-edge piece cannot be faithfully recreated by traditional prototype testing methods due to the surface roughness and imperfections caused by LAM process. Hence, direct measurement is the only option. However, it is difficult to measure flow inside such pieces with traditional velocimetry measurements due to the existence of metallic walls. Moreover, small internal size and high flow speeds call for a measurement technique with high spatial and temporal resolutions. To address these issues, we performed time-resolved X-ray PTV using the Advanced Photon Source (APS) synchrotron facility at the Argonne National Laboratory (ANL). A hydraulic system was constructed to run water, mixed with seeding particles, through the leading-edge piece. A high-speed camera captured the images of the seeding particles, which were later processed to create particle tracks. The time-averaged velocity field showed distinct pairs of vortices located in front of the porous outlet inside the leading-edge piece. The inlet channel showed reversed flow due to partial obstruction by the porous inlet of the test piece. Such knowledge of the flow field inside a leading-edge of a turbine blade will help us to design better cooling paths leading to higher cooling efficiency and increased life-span of a turbine blade.

42 ENGINEERING↗

Soft X-ray quantum efficiency of a commercial CMOS imaging sensor

The demonstrated performance and cost-effectiveness of complementary metal-oxide-semiconductor (CMOS) sensors make them a potentially attractive option for low-cost space-based X-ray observatories. We have previously reported on the performance of a commercially available backside-illuminated Sony IMX290LLR-C CMOS sensor and found it to offer X-ray spectral resolutions comparable to the charged coupled devices (CCDs) aboard Suzaku and Chandra and to have a sufficient radiation hardness for use in low Earth orbit. Here, in this work, we report on the quantum efficiency (QE) of this sensor, an essential metric for modeling the sensitivity of an instrument as an X-ray detector. Using the Advanced Photon Source at Argonne National Laboratory, we measure the soft X-ray QE of this CMOS sensor to be 0.28 ± 0.02 at a photon energy of 490.5 eV. This energy was chosen for its proximity to the astrophysically important O VII triplet emission lines (~574 eV) studied by the HaloSat mission. Although not surpassing that of the back-illuminated CCDs aboard Suzaku and Chandra, this QE compares favorably to that of the front-illuminated CCDs aboard the same observatories and is competitive with that of the silicon drift detectors used aboard HaloSat, making it a strong candidate for use on future X-ray small satellite (SmallSat) missions.

47 OTHER INSTRUMENTATION↗

Soft x-ray detection for small satellites with a commercial CMOS sensor at room temperature

Recently CMOS (complementary metal-oxide-semiconductor) sensors have progressed to a point where they may offer improved performance in imaging x-ray detection compared to the CCDs often used in x-ray satellites. We demonstrate x-ray detection in the soft x-ray band (250-1700 eV) by a commercially available back-illuminated Sony IMX290LLR CMOS sensor using the Advanced Photon Source at the Argonne National Laboratory. Additionally, while operating the device at room temperature, we measure energy resolutions (FWHM) of 47 eV at 250 eV and and 77 eV 1700 eV which are comparable to the performance of the Chandra ACIS and the Suzaku XIS. Furthermore, we demonstrate that the IMX290LLR can withstand radiation up to 17.1 krad, making it suitable for use on spacecraft in low earth orbit.

47 OTHER INSTRUMENTATION↗

Optimized illumination for high-throughput ptychography

As a scanning version of coherent diffraction imaging (CDI), X-ray ptychography has become a popular and very successful method for high-resolution quantitative imaging of extended specimens. The requirements of mostly coherent illumination and the scanning mechanism limit the throughput of ptychographic imaging. In this paper, we will introduce the methods we use at the Advanced Photon Source (APS) to achieve high-throughput ptychography by optimizing the parameters of the illumination beam. One work we have done is increasing the illumination flux by using a double-multilayer monochromator (DMM) optics with about 0.8% bandwidth. Compared with our double-crystal monochromator (DCM) optics with 0.01% bandwidth, this DMM optics provides around 20 times more flux. A multi-wavelength reconstruction method has been implemented to deal with the consequential degraded temporal coherence from such an illumination to ensure high-quality reconstruction. In the other work, we adopt a novel use of flat-top focusing optics to generate a flat-top beam with the diameter of about 1.5 µm on the focal plane. The better uniformity of the probe and the large beam size allow one to significantly increase the step size in ptychography scans and thereby the imaging efficiency.

Broad bandwidth↗

Machine learning control of an elliptically bent hard x-ray mirror

This article showcases the high-resolution control of an elliptically bent hard X-ray mirror optics at the Advanced Photon Source. The mirror uses a compact laminar flexure bending mechanism to achieve elliptical shapes covering a large range of focal distances. An array of capacitive sensors are used as a surface profiler for in-situ monitoring of the mirror shape. Machine learning and control techniques were used to change the mirror shape and focus the incident X-ray at predefined focal planes. The mirror surface shape error can be controlled to be within 40 nm rms with high repeatability. This technique gives the capability to focus incident X-ray beam within a range of focal distances corresponding to shape deformation range of a mirror optics. This work would be beneficial for controlling similar adaptive optics for multiple adaptive optics systems.

adaptive optics↗

Investigating biofilm structure using x-ray microtomography and gratings-based phase contrast

Direct examination of natural and engineered environments has revealed that the majority of microorganisms in these systems live in structured communities termed biofilms. To gain a better understanding for how biofilms function and interact with their local environment, fundamental capabilities for enhanced visualization, compositional analysis, and functional characterization of biofilms are needed. For pore-scale and community-scale analysis (100’s of nm to 10’s of microns), a variety of surface tools are available. However, understanding biofilm structure in complex three-dimensional (3-D) environments is considerably more difficult. X-ray microtomography can reveal a biofilm’s internal structure, but the obtaining sufficient contrast to image low-Z biological material against a higher-Z substrate makes detecting biofilms difficult. Here we present results imaging Shewanella oneidensis biofilms on a Hollow-fiber Membrane Biofilm Reactor (HfMBR), using the x-ray microtomography system at sector 2-BM of the Advanced Photon Source (APS), at energies ranging from 13-15.4 keV and pixel sizes of 0.7 and 1.3 μm/pixel. We examine the use of osmium (Os) as a contrast agent to enhance biofilm visibility and demonstrate that staining improves imaging of hydrated biofilms. We also present results using a Talbot interferometer to provide phase and scatter contrast information in addition to absorption. Talbot interferometry allows imaging of unstained hydrated biofilms with phase contrast, while absorption contrast primarily highlights edges and scatter contrast provides little information. However, the gratings used here limit the spatial resolution to no finer than 2 μm, which hinders the ability to detect small features. Future studies at higher resolution or higher Talbot order for greater sensitivity to density variations may improve imaging.

Environmental Molecular Sciences Laboratory↗

Streaming Data from Experimental Facilities to Supercomputers for Real-Time Data Processing

In this paper we demonstrate direct data streaming from instruments and detectors at a large-scale experimental facility to a supercomputer for real-time data processing and feedback. Streaming data to supercomputers introduces the potential for novel scientific applications and workflow models, including the ability to provide real-time feedback from very large datasets during an experiment and the integration of real-time ML training and inference at scale. We discuss a successful demonstration for real-time processing of data from the Advanced Photon Source (APS) on the Polaris supercomputer using an EPICS-based streaming framework. We describe the capabilities of the streaming framework itself, and outline the architecture that allows us to process experimentally derived data on a supercomputer without file-based data transfers. We present throughput measurements that are indicative of system performance capable of sustaining the expected data production rates of the facility, as well as discuss some outstanding challenges and our future directions.

real-time processing↗

Demonstrating Cross-Facility Data Processing at Scale with Laue Microdiffraction

In February and April 2023 live, at-scale data processing demonstrations were conducted between the Advanced Photon Source (APS), a synchrotron light source, and the Argonne Leadership Computing Facility (ALCF). These tests were run as part of a novel beamline technique: coded aperture laue micro-diffraction. This technique requires a significant amount of compute to decode appeture patterns embedded in the detector stream. An autonomous system was able to send data to ALCF during an experiment, utilize 50 nodes of the Polaris supercomputer to process 6-12 hour scans, and return the data back to the APS within 12-15 minutes behind the detector. With scan points arriving every 72 seconds, the system kept up with the beamline, potentially enabling in-experiment analysis. The data processing system utilizes Globus infrastructure and an on-demand queue to dynamically acquire nodes on Polaris. The underlying reconstruction algorithms were parallelized via MPI and accelerated with custom CUDA kernels.

Prince, Michael↗

Polycrystal Plasticity: Comparison Between Grain - Scale Observations of Deformation and Simulations

Here, the response of polycrystals to plastic deformation is studied at the level of variations within individual grains, and comparisons are made to theoretical calculations using crystal plasticity (CP). We provide a brief overview of CP and a review of the literature, which is dominated by surface observations. The motivating question asks how well does CP represent the mesoscale behavior of large populations of dislocations (as carriers of plastic strain). The literature shows consistently that only moderate agreement is found between experiment and calculation. We supplement this with a current example of microstructure evolution in the interior of a copper sample subjected to tensile deformation. Nondestructive measurements of orientation fields were performed using the near-field high-energy X-ray diffraction microscopy (nf-HEDM) technique at the Advanced Photon Source (APS). Starting at highly ordered grains, a single two-dimensional slice of microstructure containing ~150 grains was followed through multiple strain states, where it tracked lattice rotations and defect accumulation of up to 14% elongation. In accord with the literature, at the scale of individual grains, comparison of observations with CP models indicates reasonable qualitative agreement but significant variations between simulation and experiment are apparent. The conclusion is that in order to be able to quantify the effects of microstructure on the distributions of slip, orientation change, and damage accumulation, the empirically derived constitutive relations used in continuum-scale simulations need to be improved. Equally important will be the development of large-scale simulations of polycrystals that directly model dislocations.

36 MATERIALS SCIENCE↗

Tests of microstructure reconstruction by forward modeling of high energy X-ray diffraction microscopy data

Verification tests of the forward modeling technique for near-field high energy X-ray diffraction microscopy are conducted using two simulated microstructures containing uniformly distributed orientations. Comparison between the simulated and reconstructed microstructures is examined with consideration to both crystallographic orientation and spatial geometric accuracy. To probe the dependence of results on experimental parameters, simulated data sets use two different detector configurations and different simulated experimental protocols; in each case, the parameters mimic the experimental geometry used at Advanced Photon Source beamline 1-ID. Results indicate that element orientations are distinguishable to less than 0.1{sup o}, while spatial geometric accuracy is limited by the detector resolution.

36 MATERIALS SCIENCE↗

XRFtomo

Based on [1], XRFtomo brings together a variety of image processing tools used for preparing, processing and reconstructing 3D renditions of samples imaged using a synchrotron-based x-ray fluorescence (XRF) microprobe or nanoprobe at the Advanced Photon Source (APS). This software bridges the gap between data acquisition and visualization by providing tools to adjust for misalignment in the imaging process and tools for running reconstructions[2], all with the use of a GUI or command line. XRFtomo accepts .h5 files processed through MAPS[3] and it outputs reconstructed cross-sections, projections, sinograms, metadata, and a configuration file with last-used parameters for rapid processing the next time the program is launched. These images serve as inputs for other 3D visualization software for generating volumetric renderings and animations.

Marin, Fabrico↗