At least 703 records · Page 39

Comparative study of different solar cooling systems for buildings in subtropical city

In recent years, more and more attention has been paid on the application potential of solar cooling for buildings. Due to the fact that the efficiency of solar collectors is generally low at the time being, the effectiveness of solar cooling would be closely related to the availability of solar irradiation, climatic conditions and geographical location of a place. In this paper, five types of solar cooling systems were involved in a comparative study for subtropical city, which is commonly featured with long hot and humid summer. The solar cooling systems included the solar electric compression refrigeration, solar mechanical compression refrigeration, solar absorption refrigeration, solar adsorption refrigeration and solar solid desiccant cooling. Component-based simulation models of these systems were developed, and their performances were evaluated throughout a year. The key performance indicators are solar fraction, coefficient of performance, solar thermal gain, and primary energy consumption. In addition, different installation strategies and types of solar collectors were compared for each kind of solar cooling system. Through this comparative study, it was found that solar electric compression refrigeration and solar absorption refrigeration had the highest energy saving potential in the subtropical Hong Kong. The former is to make use of the solar electric gain, while the latter is to adopt the solar thermal gain. These two solar cooling systems would have even better performances through the continual advancement of the solar collectors. It will provide a promising application potential of solar cooling for buildings in the subtropical region. (author)

14 SOLAR ENERGY↗

Atomistic simulations, mesoscopic modeling, and theoretical analysis of thermal conductivity of bundles composed of carbon nanotubes

We report that the propensity of carbon nanotubes (CNTs) to self-organize into continuous networks of bundles has direct implications for thermal transport properties of CNT network materials and defines the importance of clear understanding of the mechanisms and scaling laws governing the heat transfer within the primary building blocks of the network structures—close-packed bundles of CNTs. A comprehensive study of the thermal conductivity of CNT bundles is performed with a combination of non-equilibrium molecular dynamics (MD) simulations of heat transfer between adjacent CNTs and the intrinsic conductivity of CNTs in a bundle with a theoretical analysis that reveals the connections between the structure and thermal transport properties of CNT bundles. The results of MD simulations of heat transfer in CNT bundles consisting of up to 7 CNTs suggest that, contrary to the widespread notion of strongly reduced conductivity of CNTs in bundles, van der Waals interactions between defect-free well-aligned CNTs in a bundle have negligible effect on the intrinsic conductivity of the CNTs. The simulations of inter-tube heat conduction performed for partially overlapping parallel CNTs indicate that the conductance through the overlap region is proportional to the length of the overlap for CNTs and CNT-CNT overlaps longer than several tens of nm. Based on the predictions of the MD simulations, a mesoscopic-level model is developed and applied for theoretical analysis and numerical modeling of heat transfer in bundles consisting of CNTs with infinitely large and finite intrinsic thermal conductivities. The general scaling laws predicting the quadratic dependence of the bundle conductivity on the length of individual CNTs in the case when the thermal transport is controlled by the inter-tube conductance and the independence of the CNT length in another limiting case when the intrinsic conductivity of CNTs plays the dominant role are derived. Lastly, an application of the scaling laws to bundles of single-walled (10,10) CNTs reveals that the transition from inter-tube-conductance-dominated to intrinsic-conductivity-dominated thermal transport in CNT bundles occurs in a practically important range of CNT length from ~20 nm to ~4 μm.

36 MATERIALS SCIENCE↗

High performance Data Driven Agent-based Modeling Framework for Simulation of Commute Mode Choices in Metropolitan Area

Active transportation, human-powered transportation modes such as walking and bicycling, not only reduces the carbon footprint from the transportation sector but also promotes healthy living by offering opportunities for people to build physical activity into their daily routine. To encourage active transportation through urban planning and public campaigns, it is of significant importance to infer factors that substantially influence commuters in their transportation mode choice process. This necessitates a flexible and repeatable tool that can evaluate how a policy is perceived by individual commuters and convert their decisions into macro level understanding. This paper introduces one such effort that is specifically designed for studies of transportation mode choices in metropolitan areas. It provides results from a high-resolution data driven simulation based on high performance computing implementation of the agent-based model framework for home-to-work commute trips. The framework uses a graph-partition based technique that can leverage the interaction structure of agents within a geographic proximity and can boost the simulation execution time. Further, based on a flexible design, it can run ABM with different levels of computing resources-from multi core workstations to an HPC grid. The framework has been tested on the Titan Cray XK7 supercomputer of the Oak Ridge Leadership Computing Facility.

Park, Byung↗

Multiphysics Simulation of the NASA SIRIUS-CAL Fuel Experiment in the Transient Test Reactor Using Griffin

After approximately 50 years, NASA is restarting efforts to develop nuclear thermal propulsion (NTP) for interplanetary missions. Building upon nuclear engine tests performed from the late 1950s to the early 1970s, the present research and testing focuses on advanced materials and fabrication methods. A number of transient tests have been performed to evaluate materials performance under high-temperature, high-flux conditions, with several more experiments in the pipeline for future testing. The measured data obtained from those tests are being used to validate the Griffin reactor multiphysics code for this particular type of application. Griffin was developed at Idaho National Laboratory (INL) using the MOOSE framework. This article describes the simulation results of the SIRIUS-CAL calibration experiment in the Transient Reactor Test Facility (TREAT). SIRIUS-CAL was the first transient test conducted on NASA fuels, and although the test was performed with a relatively low core peak power, the test specimen survived a temperature exceeding 900 K. Griffin simulations of the experiment successfully matched the reactor’s power transient after calibrating the initial control rod position to match the initial reactor period. The thermal-hydraulics model largely matches the time-dependent response of a thermocouple located within the experiment specimen to within the uncertainty estimate. However, the uncertainty range is significant and must be reduced in the future.

33 ADVANCED PROPULSION SYSTEMS↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hestia-SWIFL: hourly anthropogenic fossil fuel CO2 and heat on the 2km WRF grid, version 1.1

The Hestia-SWIFL version 1.1 anthropogenic heat (AH) and fossil fuel CO2 (FFCO2) emissions data product represent emissions due to the combustion of fossil fuel and cement production within the state of Arizona from 2019 to 2022. This product was developed as part of the Southwest Urban Corridor Integrated Field Laboratory (SW-IFL) project, which aims to provide new knowledge and tools that address extreme heat, air quality, climate change and related urban environmental issues by integrating high-resolution observations, modeling, and civic engagement. The emissions are generated using a bottom-up/engineering approach and are tied to results generated by the Vulcan Project version 4, an effort to quantify space/time-resolved FFCO2 & AH emissions for the entire United States landscape. A large number of data sources are combined to best estimate the emissions at fine scales such as air quality emissions data, traffic flow data, building information, sociodemographic information, and fuel statistics. The AH product provides emissions for two emissions sources (transportation and point source emissions) in units of Watts per hour per square meter (W/m2) per year (annual files) or per hour (hourly files). The FFCO2 product provides emissions from nine individual emission sectors as well as the total, and in units of tons of carbon (tC) per grid cell per year or per hour. The output made available here places the native spatial resolution of the Hestia FFCO2 & AH emissions data product (points, lines, and polygons) into a regularized 2km x 2km grid at hourly and annual temporal resolutions, and stored in netCDF files. The exact spatial extent is defined by the ASU Weather Research Forecast (WRF) simulation grid. All data are processed using R/Python pm high-performance computing system. 2-27-2026 updates: Bugs in airport hourly profile (both AH and FFCO2) and building spatial patterns (FFCO2 only) were fixed. Hourly emissions are reprocessed for all years to reflect those changes.

54 ENVIRONMENTAL SCIENCES↗

SIMPLIFIED PREDICTIVE MODELS FOR CO₂ SEQUESTRATION PERFORMANCE ASSESSMENT RESEARCH TOPICAL REPORT ON TASK #3 STATISTICAL LEARNING BASED MODELS

We compare two approaches for building a statistical proxy model (metamodel) for CO₂ geologic sequestration from the results of full-physics compositional simulations. The first approach involves a classical Box-Behnken or Augmented Pairs experimental design with a quadratic polynomial response surface. The second approach used a space-filling maxmin Latin Hypercube sampling or maximum entropy design with the choice of five different meta-modeling techniques: quadratic polynomial, kriging with constant and quadratic trend terms, multivariate adaptive regression spline (MARS) and additivity and variance stabilization (AVAS). Simulations results for CO₂ injection into a reservoir-caprock system with 9 design variables (and 97 samples) were used to generate the data for developing the proxy models. The fitted models were validated with using an independent data set and a cross-validation approach for three different performance metrics: total storage efficiency, CO₂ plume radius and average reservoir pressure. The Box-Behnken–quadratic polynomial metamodel performed the best, followed closely by the maximin LHS–kriging metamodel.

Mishra, Srikanta↗

Field Study and Energy-Plus Benchmarks for Energy Saver Homes having Different Envelope Designs

An alliance to maximize energy efficiency and cost-effective residential construction (ZEBRAlliance) built and field tested four homes that are 50 percent more energy efficient than a code compliant home. The homes are unoccupied for the duration of a two-year field study, thereby eliminating the confounding issue of occupancy habits. All homes have about the same consistent and scheduled internal load. Each home showcases a unique envelope strategy: 1) structural insulated panel (SIP), 2) optimal value wall framing (OVF), 3) advanced framing featuring the benefits of insulations mixed with phase change materials (PCM), and 4) an exterior insulation and finish system (EIFS). All homes have different weather resistive barriers (WRBs) and/or air barriers to limit air and moisture infiltration. Three homes provide space conditioning and water heating via a ground loop heat exchanger, while the fourth home uses a high efficiency air-to-air heat pump and heat pump water heater. Field performance and results of EnergyPlus V7.0 benchmarks were made for roof and attics as compared to cathedral design and for wall heat flows to validate models. The moisture content of the wall sheathing is shown to prove the protecting effectiveness of WRBs. Temperature distributions through insulations in the wall and ceiling with and without PCMs are described to characterize the performance of the PCM building envelopes.

Attic↗

Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

This paper presents a freely available Modelica library for building heating, ventilation and air conditioning systems. The library is based on the Modelica.Fluid library. It has been developed to support research and development of integrated building energy and control systems. The primary applications are controls design, energy analysis and model-based operation. The library contains dynamic and steady-state component models that are applicable for analyzing fast transients when designing control algorithms and for conducting annual simulations when assessing energy performance. For most models, dimensional analysis is used to compute the performance for operating points that differ from nominal conditions. This allows parameterizing models in the absence of detailed geometrical information which is often impractical to obtain during the conceptual design phase of building systems. In the first part of this paper, the library architecture and the main classes are described. In the second part, an example is presented in which we implemented a model of a hydronic heating system with thermostatic radiator valves and thermal energy storage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Air-Conditioner and Heat Pump Modeling (Presentation made at the Building America Stakeholders Meeting) [Slides]

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncertainty Quantification in High-Low Dynamic System Coupling using RAVEN and TRANSFORM

This work demonstrates new functionality and applications stemming from the development of high-fidelity to low-fidelity (high-low) coupling for system simulations and to further explore the capabilities of the Risk Analysis Virtual Environment (RAVEN) in the performance of uncertainty quantification in this kind of high-low coupled system models. The work builds from previous work on high-low coupling that utilized COBRA-TF (CTF), the high-fidelity subchannel analysis code, with a low fidelity model built in ORNL’s TRANSFORM, the system analysis code, utilizing the Functional Mock-Up Interface (FMI). Steady-state and transient analysis examples using the high/low coupled models generated from CTF and TRANSFORM/FMI are investigated. The workflows for both steady-state and transient coupled simulations are described. A steady-state parameter sweep and uncertainty analysis of the primary flow rates and reactor power are demonstrated. Likewise, a transient pump trip and power ramp sensitivity studies are also demonstrated. This work elucidates some of the potential benefits and future needs of using RAVEN for high/low system coupling analysis of energy systems. It also shows some of the difficulties that can be encountered in coupling system simulations.

Williams, Wesley↗

Comparative study of air-conditioning energy use of four office buildings in China and USA

Energy use in buildings has great variability. In order to design and operate low energy buildings as well as to establish building energy codes and standards and effective energy policy, it is crucial to understand and quantify key factors influencing building energy performance. Here, this study investigates air-conditioning (AC) energy use of four office buildings in four locations: Beijing, Taiwan, Hong Kong, and Berkeley. Building simulation was employed to quantify the influences of key factors, including climate, building envelope and occupant behavior. Through simulation of various combinations of the three influencing elements, it is found that climate can lead to AC cooling consumption differences by almost two times, while occupant behavior resulted in the greatest differences (of up to three times) in AC cooling consumption. The influence of occupant behavior on AC energy consumption is not homogeneous. Under similar climates, when the occupant behavior in the building differed, the optimized building envelope design also differed. In conclusion, the optimal building envelope should be determined according to the climate as well as the occupants who use the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy performance analysis of smart wall system with switchable insulation and thermal storage capacity

The ever-increasing global energy demand and the issues caused by population growth and unsustainable energy resource usages have several environmental and economic impacts. The on-demand capability of dynamic wall systems with switchable insulation systems can contribute toward energy efficiency and reduced electric cost using "building-as-a-battery." In this paper, the performance of an exterior envelope system that employs a switchable insulation system is investigated. A COMSOL simulation was used to study the envelope performance under three switchable insulation locations in the wall system. The on and off switching cycle included insulating or conducting the exterior, interior, or both sides of the mass wall system. To validate the simulation work, an experimental test was conducted in climate chamber on a 4 × 8 in. wall system with identical wall components used in the COMSOL simulation. Results show a good agreement between the experiment and simulation results. The wall system with switchable insulation placed on the exterior side provided the highest interior inward heat flux when compared with the interior or split insulation. Also, an exterior switchable insulation system in addition to a thermal mass maintained a positive heat flow for more hours when the outdoor temperature was lower than the interior temperature.

Iffa, Emishaw↗

Modular Power Electronics Approach for High Power Dynamic Wireless Charging System

Dynamic wireless power transfer (DWPT) can provide energy to EVs in motion and extend the drive range. Upscaling the charging power to 200 kW (High Power DWPT) reduces the percentage of electrified roadway required, and the solution becomes cost-effective. To smooth the power at the battery and grid, a secondary regulation stage must be added. The DWPT system therefore relies on power electronics to interface with the coils and regulate the power flow. Designing this high power system using wide bandgap devices makes ensuring high efficiency, small size, and reliable operation very challenging, and significant engineering effort is required to build such complicated systems for large-scale installation and deployment. Here, this paper describes a modular design approach for the power electronics to achieve the 200 kW wireless power transfer. As described, the SiC power electronics building block is designed, simulated, and characterized. The approach is validated in the DWPT system to build the inverter, the rectifier, and the DC/DC converter, which demonstrated high performance and reliable operation with 188 kW power.

42 ENGINEERING↗

UrbanScaping: Community Spatial Data Visualization & Analytics

Evaluating the electrification potential of buildings through retrofitting is crucial for reducing carbon emissions and the carbon footprint of built environments. This study leverages the Automatic Building Energy Modeling (AutoBEM) software, integrating the Model America database to create an urban context-based spatial analysis platform for community engagement and development. We selected Camp Hill Borough, PA, as a case study to analyze building-specific energy performance and evaluate the electrification potential of each building by switching to different Heating, Ventilation, and Air Conditioning (HVAC) systems and measurement components. The simulation results generated by the workflow provide retrofitting suggestions to help mitigate the carbon footprint as well as energy saving statistics of buildings. Additionally, the developed web-based interface serves as a community engagement platform, allowing residents to provide feedback and further develop interactive communication protocols. The outcomes of this project offer a baseline for community electrification planning and contribute to the design of low-carbon communities.

Chowdhury, Shovan [ORNL]↗

Case Study for ARRA-funded Ground-Source Heat Pump (GSHP) Demonstration at Oakland University

High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a ground-source variable refrigerant flow (GS-VRF) system installed at the Human Health Building at Oakland University in Rochester, Michigan. This case study is based on the analysis of measured performance data, maintenance records, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning as the demonstrated GS-VRF system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GS-VRF system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GS-VRF system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation, improving the operational efficiency, and reducing the installed cost of similar GSHP systems in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Airside HVAC BESTEST: HVAC Air-Distribution System Model Test Cases for ASHRAE Standard 140

This paper summarizes recent work to develop new airside HVAC equipment model analytical verification test cases for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. The analytical verification test method allows comparison of simulation results from a wide variety of building energy simulation programs with quasi-analytical solutions, further described below. Standard 140 is widely cited for evaluating software for use with performance-path energy efficiency analysis, in conjunction with well-known energy-efficiency standards including ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. Airside HVAC Equipment is a common area of modelling not previously explicitly tested by Standard 140. Integration of the completed test suite into Standard 140 is in progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Paving the Way for Net Zero Energy Codes through Performance Based Approaches

The prescriptive path is the most widely used approach for commercial code compliance in the United States. However, to achieve near-term net zero energy performance that many stakeholders in the buildings industry desire, it is clear that energy codes will need to transition from prescriptive to performance-based approaches. However, that transition is not without potential pitfalls. Among the concerns expressed by stakeholders are added complexity and cost, lack of confidence in energy modeling results, gamesmanship on the part of applicants, lack or qualified reviewers, challenges in promoting de-carbonization, and the inequity of trading long lived envelope efficiency for short lived measures such as building controls. This paper will discuss multiple approaches being evaluated and implemented by Pacific Northwest National Laboratory to improve the usability of the performance-based approach for both code compliance and beyond code programs to meet aggressive energy savings targets. A 'system performance' approach provides a simpler approach compared to whole building performance, while keeping tradeoffs limited to specific building systems. A simplified whole-building performance-based approach for small commercial buildings can cost effectively achieve deeper savings for buildings that typically follow the prescriptive compliance approach. Improved reporting and verification processes applied to the traditional performance path can provide greater confidence in simulation results and facilitate adoption of performance-based approaches. Prescriptive packages provide prescriptive solutions while targeting specific performance thresholds. This paper discusses the progress being made with each of these approaches and provides examples of their implementation in energy codes and beyond code programs.