Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

SURFACE BRIGHTNESS FLUCTUATIONS IN THE HUBBLE SPACE TELESCOPE ACS/WFC F814W BANDPASS AND AN UPDATE ON GALAXY DISTANCES

We measure surface brightness fluctuation (SBF) magnitudes in the F814W filter and (g{sub 475} - I{sub 814}) colors for nine bright early-type Fornax cluster galaxies imaged with the Hubble Space Telescope Advanced Camera for Surveys (ACS). The goal is to achieve the first systematic SBF calibration for the ACS/F814W bandpass. Because of its much higher throughput, F814W is more efficient for SBF studies of distant galaxies than the ACS/F850LP bandpass that has been used to study nearby systems. Over the color range spanned by the sample galaxies, 1.06 < (g{sub 475} - I{sub 814}) < 1.32 (AB mag), the dependence of SBF magnitude m-bar{sub 814} on (g{sub 475} - I{sub 814}) is linear to a good approximation, with slope {approx}2. When the F850LP SBF distance measurements from the ACS Fornax Cluster Survey are used to derive absolute M-bar{sub 814} magnitudes, the dependence on (g{sub 475} - I{sub 814}) becomes extremely tight, with a slope of 1.8 {+-} 0.2 and a scatter of 0.03 mag. The small observed scatter indicates both that the estimated random errors are correct and that the intrinsic deviations from the SBF-color relation are strongly correlated between the F814W and F850LP bandpasses, as expected. The agreement with predictions from stellar population models is good, both in slope and zero point, indicating that our mean Fornax distance of 20 Mpc is accurate. The models predict curvature in the relation beyond the color limits of our sample; thus, the linear calibration should not be extrapolated naively. In the appendices, we reconsider the Tonry ground-based and Jensen NICMOS SBF distance catalogs; we provide a correction formula to ameliorate the small apparent bias in the former and the offset needed to make the latter consistent with other SBF studies. We also tabulate two new SBF distances to galaxies observed in the ACS Virgo Cluster Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Reactor antineutrino anomaly

Recently, new reactor antineutrino spectra have been provided for {sup 235}U, {sup 239}Pu, {sup 241}Pu, and {sup 238}U, increasing the mean flux by about 3%. To a good approximation, this reevaluation applies to all reactor neutrino experiments. The synthesis of published experiments at reactor-detector distances <100 m leads to a ratio of observed event rate to predicted rate of 0.976{+-}0.024. With our new flux evaluation, this ratio shifts to 0.943{+-}0.023, leading to a deviation from unity at 98.6% C.L. which we call the reactor antineutrino anomaly. The compatibility of our results with the existence of a fourth nonstandard neutrino state driving neutrino oscillations at short distances is discussed. The combined analysis of reactor data, gallium solar neutrino calibration experiments, and MiniBooNE-{nu} data disfavors the no-oscillation hypothesis at 99.8% C.L. The oscillation parameters are such that |{Delta}m{sub new}{sup 2}|>1.5 eV{sup 2} (95%) and sin{sup 2}(2{theta}{sub new})=0.14{+-}0.08 (95%). Constraints on the {theta}{sub 13} neutrino mixing angle are revised.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development, calibration and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Div. at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development, calibration, and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Division at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Extreme mass-ratio inspirals in the effective-one-body approach: Quasicircular, equatorial orbits around a spinning black hole

We construct effective-one-body waveform models suitable for data analysis with the Laser Interferometer Space Antenna for extreme mass-ratio inspirals in quasicircular, equatorial orbits about a spinning supermassive black hole. The accuracy of our model is established through comparisons against frequency-domain, Teukolsky-based waveforms in the radiative approximation. The calibration of eight high-order post-Newtonian parameters in the energy flux suffices to obtain a phase and fractional amplitude agreement of better than 1 rad and 1%, respectively, over a period between 2 and 6 months depending on the system considered. This agreement translates into matches higher than 97% over a period between 4 and 9 months, depending on the system. Better agreements can be obtained if a larger number of calibration parameters are included. Higher-order mass-ratio terms in the effective-one-body Hamiltonian and radiation reaction introduce phase corrections of at most 30 rad in a 1 yr evolution. These corrections are usually 1 order of magnitude larger than those introduced by the spin of the small object in a 1 yr evolution. These results suggest that the effective-one-body approach for extreme mass-ratio inspirals is a good compromise between accuracy and computational price for Laser Interferometer Space Antenna data-analysis purposes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-569: Implementation of a Patient Specific QA Method Using EBT-XD for CyberKnife SRS/SBRT Plans

Purpose: To implement the new EBT-XD Gafchromic films for accurate dosimetric and geometric validation of stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) CyberKnife (CK) patient specific QA. Methods: Film calibration was performed using a triplechannel film analysis on an Epson 10000XL scanner. Calibration films were irradiated using a Varian Clinac 21EX flattened beam (0 to 20 Gy), to ensure sufficient dose homogeneity. Films were scanned to a resolution of 0.3 mm, 24 hours post irradiation following a well-defined protocol. A set of 12 QA was performed for several types of CK plans: trigeminal neuralgia, brain metastasis, prostate and lung tumors. A custom made insert for the CK head phantom has been manufactured to yield an accurate measured to calculated dose registration. When the high dose region was large enough, absolute dose was also measured with an ionization chamber. Dose calculation is performed using MultiPlan Ray-tracing algorithm for all cases since the phantom is mostly made from near water-equivalent plastic. Results: Good agreement (<2%) was found between the dose to the chamber and the film, when a chamber measurement was possible The average dose difference and standard deviations between film measurements and TPS calculations were respectively 1.75% and 3%. The geometric accuracy has been estimated to be <1 mm, combining robot positioning uncertainty and film registration to calculated dose. Conclusion: Patient specific QA measurements using EBT-XD films yielded a full 2D dose plane with high spatial resolution and acceptable dose accuracy. This method is particularly promising for trigeminal neuralgia plan QA, where the positioning of the spatial dose distribution is equally or more important than the absolute delivered dose to achieve clinical goals.

60 APPLIED LIFE SCIENCES↗

Methods to determine the radiated power in SPI-mitigated disruptions in JET

Here we present techniques for evaluating the radiated power in JET disruptions. Disrupting plasmas are shown to have non-axisymmetric radiation profiles, motivating the re-evaluation of the standard techniques for calculating the total radiated power at JET using bolometry. Four single-channel bolometers at different toroidal locations are exploited to quantify the radiation asymmetry. Toroidal radiation peaking factors integrated over the entire disruption of up to 1.5 have been observed when varying the quantity of neon in pellets used in disruptions mitigated by shattered pellet injection. Using synthetic bolometer diagnostics developed with the Cherab spectroscopy modeling framework, we can estimate the systematic error on total power calculations for relevant radiation profiles and improve estimates of the total radiated power. We show that the component of the systematic error on the total power due to the poloidal radiation profile can be reduced from 70% to 10% with suitable assumptions about the structure of the poloidal profile.

47 OTHER INSTRUMENTATION↗

Utilization of GIS technology to support development of flow and contaminant fate and transport models at US DOE sites - 15457

U.S. Department of Energy (DOE) sites have accumulated years of data and millions of spatial and temporal records related to the hydrological cycle, contaminant transport, and parameters of remediation technologies. In addition, numerical models which use field monitoring data to help understand flow and transport produce gigabytes of computed spatial and temporal data for each computation node. There is a need therefore for an advanced spatial data structure that can be used to address the management, processing, and analysis of spatial and temporal numerical modeling data derived from multiple sources. This can be accomplished using a geo-database. The development of an ArcSDE geo-database facilitates the centralized storage, backup, accessibility, organization, and management of model configuration and computed simulation data, putting it into a structured, coherent, and logical computer-supported system. GIS data processing and automation would enable faster and hence more complex analyses of field test data. The Applied Research Center (ARC) at Florida International University (FIU) has provided analysis of flow and transport for several watersheds at DOE's Oak Ridge Reservation (ORR), including East Fork Poplar Creek (EFPC), Upper EFPC in the Y-12 National Security Complex area (Y-12 NSC) and White Oak Creek (WOC). Integrated surface and subsurface flow, fate and transport models were developed to provide analysis of contaminant patterns within each watershed. In addition, digital monitoring data available from the Oak Ridge Environmental Information System (OREIS) related to mercury (Hg) contamination and remediation within these watersheds was used for calibration and verification of the model. Experimental studies were also carried out which provided kinetic and equilibrium data about important parameters related to Hg transport, speciation and methylation/demethylation kinetics within the watershed. Geographic Information Systems (GIS) technology was employed to support the modeling work through storage and geo-processing of spatial and temporal data required by the models and to produce hydrogeological maps for visualization. An ArcGIS geo-database was developed for centralized storage and management of experimental and computed model data and its capabilities were extended over the years using tools such as ModelBuilder combined with Python scripting to automate repetitive tasks, perform statistical analyses and generate maps and reports. The hydrologic geo-database model developed possesses a structure that enables linkage with scalable hydrologic modeling tools/applications to model hydrologic systems, and in this case, enables the testing of the potential impacts of various remediation scenarios on the ORR watersheds. The ArcSDE geo-database can also be used to automate and simplify the process of calling stored GIS and time series data. This geo-database can serve as a tool for contaminant flow and transport analyses which require large amounts of high-quality spatial and temporal data in order to ensure reliability and validity of modeling results. The existing geo-database structure developed for the hydrological modeling at ORR was designed to be replicable for application at other DOE sites. An investigation of downloadable free/open source GIS software along with required security protocols to facilitate online querying of the database was also conducted to determine methods by which project-derived data can be more easily shared with other project stakeholders such as DOE personnel and site contractors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PHOTOMETRY AND PHOTOMETRIC REDSHIFT CATALOGS FOR THE LOCKMAN HOLE DEEP FIELD

We present broadband photometry and photometric redshifts for 187,611 sources located in {approx}0.5 deg{sup 2} in the Lockman Hole area. The catalog includes 388 X-ray-detected sources identified with the very deep XMM-Newton observations available for an area of 0.2 deg{sup 2}. The source detection was performed on the R{sub c}-, z'-, and B-band images and the available photometry is spanning from the far-ultraviolet to the mid-infrared, reaching in the best-case scenario 21 bands. Astrometry corrections and photometric cross-calibrations over the entire data set allowed the computation of accurate photometric redshifts. Special treatment is undertaken for the X-ray sources, the majority of which are active galactic nuclei (AGNs). For normal galaxies, comparing the photometric redshifts to the 253 available spectroscopic redshifts, we achieve an accuracy of {sigma}{sub {Delta}z/(1+z)} = 0.036, with 12.6% outliers. For the X-ray-detected sources, compared to 115 spectroscopic redshifts, the accuracy is {sigma}{sub {Delta}z/(1+z)} = 0.069, with 18.3% outliers, where the outliers are defined as sources with |z{sub phot} - z{sub spec}| > 0.15 Multiplication-Sign (1 + z{sub spec}). These results are a significant improvement over the previously available photometric redshifts for normal galaxies in the Lockman Hole, while it is the first time that photometric redshifts are computed and made public for AGNs for this field.

79 ASTRONOMY AND ASTROPHYSICS↗

Top Quark Mass Measurement in the lepton+jets Channel Using a Matrix Element Method and in situ Jet Energy Calibration

A precision measurement of the top quark mass m{sub t} is obtained using a sample of tt events from pp collisions at the Fermilab Tevatron with the CDF II detector. Selected events require an electron or muon, large missing transverse energy, and exactly four high-energy jets, at least one of which is tagged as coming from a b quark. A likelihood is calculated using a matrix element method with quasi-Monte Carlo integration taking into account finite detector resolution and jet mass effects. The event likelihood is a function of m{sub t} and a parameter {Delta}{sub JES} used to calibrate the jet energy scale in situ. Using a total of 1087 events in 5.6 fb{sup -1} of integrated luminosity, a value of m{sub t}=173.0{+-}1.2 GeV/c{sup 2} is measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of High Performance Computing on the Detailed Simulation of Subsurface Flow and Contaminant Transport Using eSTOMP - 16341

The ability to model subsurface processes at the field-scale is essential to site closure and remedial action decisions. Field-scale models often require high-performance computing to meet the computational demands associated with complex systems, model calibration, and uncertainty quantification. eSTOMP, a parallel version of STOMP, is an analytical tool that meets the need for investigating coupled processes in the subsurface involving regional multi-fluid flow and biogeochemistry. The scalability of eSTOMP makes it ideal for simulating contaminant and geochemical reactive transport when long run times result from execution of a serial code. To demonstrate the impact of high-performance computation on subsurface analyses, the application of eSTOMP is presented for two sites. The first site involves uranium surface complexation within a highly dynamic, variably saturated flow field. The use of this model in conjunction with continued field monitoring is expected to provide a rigorous basis for developing operational strategies for field remediation and for defining defensible remediation endpoints. The second site involves the long-term dissolution of low-level radioactive glass emplaced within a near-surface repository. The waste form release rate is evaluated by modeling the basic physical and chemical processes that are known to control the waste form dissolution behavior, including pH and composition of the fluid contacting the glass. Simulations demonstrate that glass dissolution rates vary both in time and as a function of position within the disposal system, and that a 'leach rate' or radionuclide release rate parameter can only be estimated after identifying these impacts in a dynamic system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗

Magnetic Field Angular Dependence of Magnetization Loss in ReBCO Superconducting Tapes

In the applications of high-temperature superconductors (HTS), the HTS tapes are usually exposed to the external magnetic field with different orientations. The critical current and AC loss are affected by both the field amplitude and field angles due to the anisotropy of HTS tapes. In this work, we first introduce the experimental system to measure the magnetization loss in HTS tapes based on the calibration-free method. Then, we present the magnetization loss results in 4.8-mm-wide AMSC wire, 4-mm-wide SuperPower wire, 4-mm-wide SuNam wire, and 10-mm-wide Fujikura wire in a perpendicular applied field at 77 K. The field amplitude is up to 100 mT, and the frequency varies from 44.2 to 87.1 Hz. We also present the magnetization loss in AMSC wire, SuperPower wire, SuNam wire, and Fujikura wire at different field angles. The field angle varies from 10 to 90 {sup ∘} in 10 {sup ∘} steps. The loss reduction with the decreasing of the field angle shows the anisotropic property of HTS tapes. We finally plot the measured magnetization loss of the samples as a function of the magnetic field amplitude normalized by the field angle to verify an empirical formula.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact Damage Investigation on Glass Fiber-Reinforced Plate Laminates at Room and Lower Temperatures through Ultrasound Testing and Electronic Speckle Pattern Interferometry

In this work, the evaluation of damage area due to low-velocity impact tests at different impact energy values and different temperatures on glass fiber-reinforced plate laminates was investigated by two nondestructive evaluation (NDE) techniques, electronic speckle pattern interferometry (ESPI) and ultrasound testing (UT). Composites are characterized by several interacting failure modes such as matrix breakage, fiber failure and delaminations, which can be simultaneously induced by low-velocity impacts and can be different depending on the temperature. It can be complicated to detect by visual inspections of the structures for such phenomena. This paper aims to investigate the dependence of the damaged area with respect to temperature variation on glass fiber composite laminates. GF composite laminates were impacted with three energy levels (5, 10, 20 J) and at different temperatures (room temperature, − 25, − 50 °C) by a drop weight impact machine. The results show that at decreasing temperature, a decrease in the damage extension was observed, which is more evident at increasing impact energy. Moreover, as expected, the results confirm UT and ESPI techniques are able to identify the barely visible low-velocity impact damage. However, some limitations for detection were found in ESPI. Nonetheless, the ESPI technique can be considered as one of the useful NDE methods if the calibration and the post-processing methods are improved.

36 MATERIALS SCIENCE↗

Gap-filling eddy covariance methane fluxes: Comparison of machine learning model predictions and uncertainties at FLUXNET-CH4 wetlands

Time series of methane fluxes measured by eddy-covariance require gap-filling to estimate annual emissions. Gap-filling methane fluxes is challenging because of high variability and complex responses to multiple drivers. To date, there is no widely established gap-filling standard for methane, with regards both to the best model algorithms and predictors. In this study, we address the need for standardization by synthesizing results of gap-filling methods applied at 17 wetland sites spanning boreal to tropical regions including all major wetlands classes and two rice paddies. We introduce new procedures for: 1) creating realistic artificial gap scenarios, 2) training and evaluating gap-filling models without overstating performance, and 3) predicting half-hourly methane fluxes and annual emissions with robust uncertainty estimates. We tested a conventional method (marginal distribution sampling) and four machine learning algorithms - penalized linear regression, artificial neural networks, random forests, and boosted decision trees - and four predictor sets, including temporal, meteorological, ecosystem carbon and energy flux, and soil predictors. We find that the conventional method can achieve similar median performance to the machine learning models but is worse than the best machine learning models and relatively insensitive to predictor choices. Of the machine learning models, decision tree algorithms performed the best in cross-validation experiments, even with a baseline predictor set, and artificial neural networks showed comparable performance when using all predictors. Soil temperature was frequently the most important predictor whilst water table depth was important at sites with substantial water table fluctuations, highlighting the value of data on soil conditions. Raw gap-filling uncertainties from the machine learning models were underestimated and we propose a method to calibrate uncertainties to observations. Finally, we gap-fill and provide summary evaluation metrics for all 81 sites in the FLUXNET-CH4 community dataset and publicly release the python code for model development, evaluation, and uncertainty estimation.

42 ENGINEERING↗

Soot volume fraction in a piloted turbulent jet non-premixed flame of natural gas

Planar laser-induced incandescence (LII) has been used to measure soot volume fraction in a well-characterised, piloted, turbulent non-premixed flame known as the ''Delft Flame III''. Simulated Dutch natural gas was used as the fuel to produce a flame closely matching those in which a wide range of previous investigations, both experimental and modelling, have been performed. The LII method was calibrated using a Santoro-style burner with ethylene as the fuel. Instantaneous and time-averaged data of the axial and radial soot volume fraction distributions of the flame are presented here along with the Probability Density Functions (PDFs) and intermittency. The PDFs were found to be well-characterised by a single exponential distribution function. The distribution of soot was found to be highly intermittent, with intermittency typically exceeding 97%, which increases measurement uncertainty. The instantaneous values of volume fraction are everywhere less than the values in strained laminar flames. This is consistent with the soot being found locally in strained flame sheets that are convected and distorted by the flow. (author)

03 NATURAL GAS↗

A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector

We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. Finally, an infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable’s motion, and the system was controlled via a graphical user interface.

42 ENGINEERING↗