Search NASA⌕ Search

SEARCH · Search NASA

Results for “Commercial Building Loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

689 records · Page 39

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Investigating the Simulink Auto-Coding Process

Model based program design is the most clear and direct way to develop algorithms and programs for interfacing with hardware. While coding "by hand" results in a more tailored product, the ever-growing size and complexity of modern-day applications can cause the project work load to quickly become unreasonable for one programmer. This has generally been addressed by splitting the product into separate modules to allow multiple developers to work in parallel on the same project, however this introduces new potentials for errors in the process. The fluidity, reliability and robustness of the code relies on the abilities of the programmers to communicate their methods to one another; furthermore, multiple programmers invites multiple potentially differing coding styles into the same product, which can cause a loss of readability or even module incompatibility. Fortunately, Mathworks has implemented an auto-coding feature that allows programmers to design their algorithms through the use of models and diagrams in the graphical programming environment Simulink, allowing the designer to visually determine what the hardware is to do. From here, the auto-coding feature handles converting the project into another programming language. This type of approach allows the designer to clearly see how the software will be directing the hardware without the need to try and interpret large amounts of code. In addition, it speeds up the programming process, minimizing the amount of man-hours spent on a single project, thus reducing the chance of human error as well as project turnover time. One such project that has benefited from the auto-coding procedure is Ramses, a portion of the GNC flight software on-board Orion that has been implemented primarily in Simulink. Currently, however, auto-coding Ramses into C++ requires 5 hours of code generation time. This causes issues if the tool ever needs to be debugged, as this code generation will need to occur with each edit to any part of the program; additionally, this is lost time that could be spent testing and analyzing the code. This is one of the more prominent issues with the auto-coding process, and while much information is available with regard to optimizing Simulink designs to produce efficient and reliable C++ code, not much research has been made public on how to reduce the code generation time. It is of interest to develop some insight as to what causes code generation times to be so significant, and determine if there are architecture guidelines or a desirable auto-coding configuration set to assist in streamlining this step of the design process for particular applications. To address the issue at hand, the Simulink coder was studied at a foundational level. For each different component type made available by the software, the features, auto-code generation time, and the format of the generated code were analyzed and documented. Tools were developed and documented to expedite these studies, particularly in the area of automating sequential builds to ensure accurate data was obtained. Next, the Ramses model was examined in an attempt to determine the composition and the types of technologies used in the model. This enabled the development of a model that uses similar technologies, but takes a fraction of the time to auto-code to reduce the turnaround time for experimentation. Lastly, the model was used to run a wide array of experiments and collect data to obtain knowledge about where to search for bottlenecks in the Ramses model. The resulting contributions of the overall effort consist of an experimental model for further investigation into the subject, as well as several automation tools to assist in analyzing the model, and a reference document offering insight to the auto-coding process, including documentation of the tools used in the model analysis, data illustrating some potential problem areas in the auto-coding process, and recommendations on areas or practices in the current Ramses model that should be further investigated. Several skills were required to be built up over the course of the internship project. First and foremost, my Simulink skills have improved drastically, as much of my experience had been modeling electronic circuits as opposed to software models. Furthermore, I am now comfortable working with the Simulink Auto-coder, a tool I had never used until this summer; this tool also tested my critical thinking and C++ knowledge as I had to interpret the C++ code it was generating and attempt to understand how the Simulink model affected the generated code. I had come into the internship with a solid understanding of Matlab code, but had done very little in using it to automate tasks, particularly Simulink tasks; along the same lines, I had rarely used shell script to automate and interface with programs, which I gained a fair amount of experience with this summer, including how to use regular expression. Lastly, soft-skills are an area everyone can continuously improve on; having never worked with NASA engineers, which to me seem to be a completely different breed than what I am used to (commercial electronic engineers), I learned to utilize the wealth of knowledge present at JSC. I wish I had come into the internship knowing exactly how helpful everyone in my branch would be, as I would have picked up on this sooner. I hope that having gained such a strong foundation in Simulink over this summer will open the opportunity to return to work on this project, or potentially other opportunities within the division. The idea of leaving a project I devoted ten weeks to is a hard one to cope with, so having the chance to pick up where I left off sounds appealing; alternatively, I am interested to see if there are any opening in the future that would allow me to work on a project that is more in-line with my research in estimation algorithms. Regardless, this summer has been a milestone in my professional career, and I hope this has started a long-term relationship between JSC and myself. I really enjoy the thought of building on my experience here over future summers while I work to complete my PhD at Missouri University of Science and Technology.

Gualdoni, Matthew J.↗

Advanced SOFC quality control and the role of manufacturing defects on stack reliability

Atrex Energy rolled out first commercial SOFC generator products in 2013. Following that we embarked on implementation of mass production in order to ramp up productivity and lower the costs in the meantime. To ensure the goal of mass production, an accurate, cost effective and consistent quality control methodology needs to be in place. The aim of this DOE funded project is to devise a machine and methodology for cell quality control using modern non-destructive testing methods and cell rejection criterion based on the empirical determination of the role of manufacturing flaws on stack degradation and reliability. The work scope encompasses two goals aimed at 1) developing automatable techniques for objective flaw detection and 2) developing an understanding of the ramifications of flaws on stack and cell reliability. By accomplishing these two goals it is likely that an advanced stage Quality Control (QC) device can be developed. This project scope encompasses: 1) Invention of a high speed automated instrument for spatial mapping of surface and sub-surface imperfections in production cells (ex situ) using modern imaging techniques. 2) Identification of rejection criteria upon which to screen cells from production by: a. Magnification of the effect of production defects on cell degradation through fabrication and testing of micro-cells which encompass these imperfections. b. The long term testing of full size production cells both as single cells and in small stacks, in order to correlate the (in situ) performance and degradation with the imperfection type (identified ex-situ) and hence be able to classify imperfections as actual defects. We first built a defect library with the cells containing imperfections classified and documented. The cells with various imperfections were tested to evaluate the imperfection potential impact on cell electrochemical performance. Evaluations were conducted on minicell, single cell and stack levels. On minicell level, pinhole, scratch, crack, contamination, and pop-out were investigated. We found: (1) none of the imperfections causes calamity type failure, (2) pinholes do not show measurable effect on minicell performance, (3) imperfection such as electrolyte abrasion, scratch, and pop out cause minicell potential to fluctuate by different degrees; the cells with such imperfections exhibit sensitivity of potential to high fuel utilization and “self healing” behavior. On single cell level we evaluated the effect of long crack and high population pinholes. The cell with a long crack does not show performance compromise at start. There is no potential fluctuation or sensitivity to high fuel utilization or catastrophic failure. The voltage degradation due to thermal cycle is slightly higher than normal cells. The cells with high population pinholes perform surprisingly as well as normal cells over a period of 3,500h. Even when subjected to cyclic load condition, the cells 4 show negligible degradation. Our cells appear to have “self immunization” feature which fends off the adversary effects of certain imperfections. Defects were also evaluated on stack level. Two stacks were made each with ten defect cells. The first stack was tested for 13,2000h under steady load condition while the second was tested for 9,000h under transient load conditions. We found: (1) voltage fluctuation and sensitivity to thermal cycle were not observed in contrast to minicell test, (2) of the various cracks examined, including longitudinal cracks, circumferential crack, crack near closed and open ends, none exhibited distinguishable impact on performance, (3) defect cells exhibited higher degradation rates on average under steady load condition; Individually some defect cells performed similarly or better than reference cells, (4) under steady load condition all the cells degrade monotonically with degradation rate increasing with time, (5) under cyclic (transient) load condition, both defect and reference cells exhibit complex dynamic behaviors, (6) fuel loss (leak) was measured occasionally for stack 1, the cells with crack showed the highest fuel loss increase, nevertheless, no correlation with performance degradation could be established with certainty, and (7) no catastrophic failure ever happened other than incremental degradation. Posttest inspection and microanalysis were carried out; the observations are summarized in what follows: (1) Electrolyte pinholes, some scratches and IC porosity became undetectable after testing. (2) The cathode covering the popout defects is intact without any cracking or delamination. (3) The scratch was covered by cathode in pristine state; Ni oxide or NiO-YSZ filled the space where electrolyte was missing. After >10,000h operation, the cathode that used to cover the scratch was missing but the size of the scratch remains unchanged; there is a fairly dense Ni oxide layer on top of the scratch. (4) All of the cracks remain their original dimensions. Current collector kept longitudinal cracks closed which mitigated the adversary effect of crack on cell performance/durability. (5) The crack at open end showed some deterioration manifested by a small oxidation zone in the vicinity of the crack. Wide spectrum of imaging techniques were surveyed and evaluated to detect tubular SOFC defects. Optical methods, with and without assistance of expression technique, were applied to detect all kinds of defects. Thermograph method in combination of CO2 leak, ultra-sound and electric potential was also extensively evaluated to detect surface and under-surface defects such as short circuit. Based on these works, laser camera has been selected to build the final QC machine vision inspection system. The Gocator laser profile sensor was setup to generate 2D surface intensity images of tubular SOFC surface which were analyzed with Sherlock machine vision software supplied by Teledyne Dalsa. The Gocator output was integrated with the Sherlock software and enabled live images to be imported by a Common Vision Blox driver. The Sherlock software was programmed to detect various surface defects from the surface intensity images generated by the Gocator. These measurements are subsequently used to make pass or fail decisions.

01 COAL, LIGNITE, AND PEAT↗

Core design studies for advanced burner test reactor.

The U.S. government announced in February 2006 the Global Nuclear Energy Partnership (GNEP) to expand the use of nuclear energy to meet increasing global energy demand, to address nuclear waste management concerns and to promote non-proliferation. The advanced burner reactor (ABR) based on a fast spectrum is one of the three major technologies to be demonstrated in GNEP. In FY06, a pre-conceptual design study was performed to develop an advanced burner test reactor (ABTR) that supports development of a prototype full-scale ABR, which would be followed by commercial deployment of ABRs. The primary objectives of the ABTR were (1) to demonstrate reactor-based transmutation of transuranics (TRU) as part of an advanced fuel cycle, (2) to qualify the TRU-containing fuels and advanced structural materials needed for a full-scale ABR, (3) to support the research, development and demonstration required for certification of an ABR standard design by the U.S. Nuclear Regulatory Commission. Based on these objectives, core design and fuel cycle studies were performed to develop ABTR core designs, which can accommodate the expected changes of the TRU feed and the conversion ratio. Various option and trade-off studies were performed to determine the appropriate power level and conversion ratio. Both ternary metal alloy (U-TRU-10Zr) and mixed oxide (UO{sub 2}-TRUO{sub 2}) fuel forms have been considered with TRU feeds from weapons-grade plutonium (WG-Pu) and TRU recovered from light water reactor spent fuel (LWR-SF). Reactor performances were evaluated in detail including equilibrium cycle core parameters, mass flow, power distribution, kinetic parameters, reactivity feedback coefficient, reactivity control requirements and shutdown margins, and spent fuel characteristics. Trade-off studies on power level suggested that about 250 MWt is a reasonable compromise to allow a low project cost, at the same time providing a reasonable prototypic irradiation environment for demonstrating TRU-based fuels. Preliminary design studies showed that it is feasible to design the ABTR to accommodate a wide range of conversion ratio (CR) by employing different assembly designs. The TRU enrichments required for various conversion ratios and the irradiation database suggested a phased approach with initial startup using conventional enrichment plutonium-based fuel and gradual transitioning to full core loading of transmutation fuel after its qualification phase (resulting in {approx}0.6 CR). The low CR transmutation fuel tests can be accommodated in the designated test assemblies, and if fully developed, core conversion to low CR fuel can be envisioned. Reference ABTR core designs with a rated power of 250 MWt were developed for ternary metal alloy and mixed oxide fuels based on WG-Pu feed. The reference core contains 54 driver, 6 test fuel, and 3 test material assemblies. For the startup core designs, the calculated TRU conversion ratio is 0.65 for the metal fuel core and 0.64 for the oxide fuel core. Both the metal and oxide cores show good performances. The metal fuel core requires an average TRU enrichment of 18.8% and yields a reactivity swing of 1.2 %{Delta}k over the 4-month cycle. The core average flux level is {approx}2.4 x 10{sup 15} n/cm{sup 2}s, and test assembly flux level is {approx}2.8 x 10{sup 15} n/cm{sup 2}s. Compared to the metal fuel core, the lower density oxide fuel core requires an average TRU enrichment of 21.8%, which results in a 780 kg TRU loading (as compared to 732 kg for metal) despite a {approx}9% smaller heavy metal inventory. The lower heavy metal inventory increases the burnup reactivity swing by {approx}10% and reduces the flux levels by {approx}8%. Alternative designs were also studied for a LWR-SF TRU feed and a low conversion ratio, including the recycle of the ABTR spent fuel TRU. The lower fissile contents of the LWR-SF TRU relative to the WG-Pu TRU significantly increase the required TRU enrichment of the startup cores to maintain the same cycle length. The even lower fissile fraction of the ABTR spent fuel TRU further increases the TRU enrichments of the recycled cores. The reduced fissile content increases the fissile conversion ratio, and the increased TRU enrichment decreases the TRU conversion ratio. For example, the average TRU enrichment of the recycled core increases from 18.8% to 27.2% for the metal fuel and from 21.8% to 33.4% for the oxide core. The TRU conversion ratio is decreased from 0.65 to 0.56 for the metal core and from 0.64 to 0.52 for the oxide core. In the full paper, the details of design and performance characteristics will be presented along with the analysis methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Tonnage Forest Biomass Production Systems from Southern Pine Energy Plantations

In this study, a high-tonnage harvesting system designed specifically to operate efficiently in the expected stand types of a bioenergy scenario was built, deployed, and evaluated in a production setting. Stands on which the system was evaluated exhibited the heavy stocking levels (> 600 stems per acre) and tree size distributions with significant volume in small stems (down to 2” DBH) that were expected in the modified energy plantation silvicultural approach. The harvest system also was designed to be functional in the traditional plantation stands dominating the commercial forestry landscape in the region. The Tigercat 845D feller buncher, which was a prototype machine designed for the high tonnage harvest system, used a boom-mounted prototype DT1802 shear felling head and incorporated a number of options intended to maximize its small-stem productivity, including: a high-speed shear severing system that was cheaper to operate than a saw; a large-pocket felling head that allowed larger accumulations of small stems to be built before expending the time to drop them for the skidder; efficient, low ground pressure, tracked carrier system to decrease the amount of maneuvering, saving time and minimizing soil disturbance; and various energy-saving devices to lower fuel costs and minimize air quality impacts. Overall, the feller buncher represented a quantum advance in small-stem harvesting technology. Extensive testing showed the machine’s production rate to be relatively insensitive to piece size, much less so than comparable traditional equipment. In plantation stands, the feller buncher was able to produce approximately 100 green tons of biomass per productive machine hour (PMH), and in natural stands, it produced nearly 120 green tons per PMH. The ability of the high tonnage feller buncher to maintain high productivity in stands with smaller diameter stems is something that has not been achieved in previous feller buncher designs. The Tigercat 845D feller buncher is now a production machine for Tigercat and is being sold in their current product line. The high-speed felling system was paired with a Tigercat 630D skidder and high-capacity grapple; one that could match the felling productivity when pulling small stems. The harvesting system minimized hourly costs using a single, high-capacity skidder (with a single operator), rather than two smaller ones, which is the traditional practice. The skidder itself can be considered a mid-range size and had an engine no larger than other machines in its class, but it incorporated a very large capacity 25 ft2 grapple. The large grapple is well suited to grabbing and hauling a large bunch of small-diameter trees, as produced by the high tonnage feller buncher. The grapple worked effectively in larger stems as well, but its ability to carry large numbers of small stems meant the average payload did not drop as stand DBH decreased. Tests with the machine indicated its travel speeds were nearly the same as, or perhaps slightly better than, conventionally equipped skidders, but grapple capacity was 75% larger. Productivity and cost per ton of the new skidder were better than conventional skidders for average skid distances of any length greater than 100 feet. Measured skidder productivity was as high as 143 gt/PMH. Its productivity exceeded that of the high-capacity feller buncher for skid distances out to nearly 700 feet, so system productivity could be expected to remain high for stands of a size typical in the southern U.S. The Tigercat 630D skidder is a production machine for Tigercat and the large grapple can now be ordered by customers using it for small diameter trees. When the feller buncher and skidder are analyzed as a two-machine system, overall productivity is fixed at the level of the least productive machine. Results from a set of side-by-side tests in the same density stand with conventional feller bunchers and skidders showed that the high tonnage system produced 97 gt/PMH versus 68 gt/PMH for a comparable conventional system. Machine rate costs for felling and skidding were $2.31/gt and $3.72/gt for the high tonnage, and conventional systems, respectively. However, the most significant result of the project is that the high tonnage system was shown to be relatively insensitive to tree size. This ability to maintain felling and skidding productivity and cost as tree size decreases is a breakthrough in harvesting systems for southern pine plantations. The concept of transpirational drying of woody biomass was tested at an industrial scale at multiple locations during this project. Felled trees were allowed to dry in two scenarios: 1) in bunches where they were felled, and 2) in roadside piles. Although the wood piled in large piles at roadside did experience drying, the wood left in bunches experienced a greater moisture reduction. Drying times of 72 days in the late summer resulted in mean wood moisture content of 26% for skidder bunches and 39% for the large pile at roadside as compared to moisture contents of 55% to 58% for freshly cut trees. An existing whole-tree chipper, Precision 2675, was modified to allow production of chips smaller than the traditional pulp size chip (i.e. “microchips”). Feed rates and knife placements were retained in the new design, while additional pockets were incorporated in the chipper disk to allow the attachment of either four knives for pulp chips or eight knives for microchips. This design facilitated switching between the energy and pulp chip product options at relatively low expense (about ½ day downtime). Chipping of whole-trees into pulp chips and microchips with the Precision 2675 disk chipper resulted in average productivities of 79.5 gt/PMH and 70.7 gt/PMH, respectively. Production rates of the chipper were lower when producing microchips by about 10% relative to producing pulp chips, but rates were similar to those achievable when making clean pulp chips. Particle size analysis for clean pine microchips revealed 26.6% retention on a 13 mm (slightly less than 3/8-inch) round hole screen and 25.9% retention for whole-tree pine microchips. For comparison, clean pine pulp chips had 52.2% retained. Ash content (% dry basis) was 0.54% for clean pine microchips and 0.62% for whole-tree pine microchips. Ash content for clean pine pulp chips was 0.39%. For transpirationally-dried material there was 38.1% retention for whole-tree microchips on a 13mm screen compared to 70.1% for dried clean pulp chips. Ash content was 0.78% and 0.44% respectively for these two chip types. Clean pine microchips stored at roadside had 25.2% retention on a 13 mm screen and 0.50% ash content. For mixed species (pine and hardwood), whole-tree microchips had 25.1% retention on a 13 mm screen compared to 50.6% for whole-tree pulp chips. Ash content was 2.12% and 2.74% respectively for these two chip types. Clean hardwood microchips stored at roadside had 35.0% retention on a 13 mm screen and an ash content of 1.24%. There are two significant advantages to using transpirational drying: reduced transportation costs, and reduced drying costs (capital and operating costs) for the biorefinery. This project evaluated the potential to reduce transportation costs through transpirational drying, and it included a component that tested higher capacity chip trailers (23% larger volume) to be able to transport dry wood with a lower bulk density. For transpirationally-dried chips at 35% MC, the high-capacity trailers achieved loads with a mean payload of 24 tons with maximum payloads of 29 tons. The typical legal payload on this trailer is 28.5 tons. Therefore, the project demonstrated that it is possible to achieve maximum legal payloads on chip trailers with transpirationally dried wood. Assuming that the truck is loaded to the legal payload limit, the transportation costs of chips can be reduced from $15.91/dry ton (dt) for 56% MC wood to $10.77/dt for transpirationally dried wood at 35% MC (for an example 50-mile haul distance at $0.14 per one-way ton-mile). For longer haul distances, these savings in trucking costs become even more significant. These results have demonstrated how significant savings in transportation costs can be achieved through transpirational drying. Also, these results show that it may be possible to increase the procurement radius for a biorefinery by using transpirational drying. Further cost reductions can be realized by the biorefinery when drying costs are reduced. The goal of this study was development of a timber harvesting system as productive in stands optimized for biomass production as it was in stands grown for roundwood markets. If that goal is achieved, a logger can invest in a single suite of equipment and operate efficiently in any future silvicultural regime that might include energy feedstocks as an output. It was the premise of the study that a future biomass market would shift the age distribution and stem size in stands grown for energy downward, and the key strategy in developing a harvest system for that scenario would be creating one with logging costs relatively insensitive to tree size. Our vision for such a system included a felling machine with a large capacity head to minimize time spent building bunches, plus a skidder capable of moving large volumes of small trees. The study proposed building the system and testing it against existing equipment in stands similar to those envisioned as resulting from biomass-optimized silviculture. As stated previously, the new feller buncher and skidder evaluated on their own merits showed their designs were clearly a step in the right direction - their productivity was indeed high and less sensitive to reductions in stem size. Cost projections based on extensive time and production studies of the high tonnage and benchmark operations showed modest advantages in FOB costs of the new system in both ‘average’ and simulated ‘energy’ stands (7.7% and 9.5%, respectively). But it was clear, when coupled into a traditional logging system, the in-woods productivity advantage of the modified equipment was easily overwhelmed by inefficiencies in chipping or trucking. Some additional savings can be achieved by spreading the cost of the feller buncher over multiple chipping operations (another 7.5%), but generally, in stands with average DBH above 6 inches, the in-woods equipment was not limiting productivity, and costs were driven by chipping and transport. Our results were a positive step in lowering delivered cost of trees grown for energy purposes, but they also argue strongly for a more comprehensive approach in solving this issue. The procurement system in its entirety has to be optimized to take full advantage of the productivity gains achieved with the machines and transpirational drying techniques developed in this project. We have to understand the true costs of all logistical options, particularly those of the choice in chipping strategy and in truck allocation, both of which seemed, in this study, to be the greatest source of variability in cost, and often the most expensive operations as well.

09 BIOMASS FUELS↗