At least 703 records · Page 39

Evaluation of a microwave high-power reception-conversion array for wireless power transmission

Initial performance tests of a 24-sq m area array of rectenna elements are presented. The array is used as the receiving portion of a wireless microwave power transmission engineering verification test system. The transmitting antenna was located at a range of 1.54 km. Output dc voltage and power, input RF power, efficiency, and operating temperatures were obtained for a variety of dc load and RF incident power levels at 2388 MHz. Incident peak RF intensities of up to 170 mW/sq cm yielded up to 30.4 kW of dc output power. The highest derived collection-conversion efficiency of the array was greater than 80 percent.

Dickinson, R. M.↗

Terrestrial solar thermionic energy conversion systems concept

Results obtained from studies of a (1) solar concentrator, (2) solar energy receiver - thermionic converter system, and (3) solar thermionic topping system are described. Peripheral subsystems, which are required for any solar energy conversion system, are also discussed.

Shimada, K.↗

Design and performance of a no-single-failure control system for the mini-Brayton power conversion system

The control system consists of the ac-dc conversion, voltage regulation, speed regulation through parasitic load control, and overload control. A no-single-failure configuration was developed to attain the required reliability for a 10-year design life of unattended operation. The design principles, complete schematics, and performance are reported. Testing was performed on an alternator simulator pending construction of the actual Mini-Brayton alternator.

Brichenough, A. G.↗

Reception-Conversion Subsystem (RXCV) for microwave power transmission system

As part of a program to demonstrate the feasibility of power transmission from space, an approximately 25 sq m Reception-Conversion Subsystem was designed and tested. The device collects high power microwave energy, converts it into dc, and dissipates it in an instrumented demonstration load.

Raytheon Company↗

Comparative Evaluation of Phase 1 Results from the Energy Conversion Alternatives Study (ECAS)

Ten advanced energy conversion systems for central-station, based-load electric power generation using coal and coal-derived fuels which were studied by NASA are presented. Various contractors were selected by competitive bidding to study these systems. A comparative evaluation is provided of the contractor results on both a system-by-system and an overall basis. Ground rules specified by NASA, such as coal specifications, fuel costs, labor costs, method of cost comparison, escalation and interest during construction, fixed charges, emission standards, and environmental conditions, are presented. Each system discussion includes the potential advantages of the system, the scope of each contractor's analysis, typical schematics of systems, comparison of cost of electricity and efficiency for each contractor, identification and reconciliation of differences, identification of future improvements, and discussion of outside comments. Considerations common to all systems, such as materials and furnaces, are also discussed. Results of selected in-house analyses are presented, in addition to contractor data. The results for all systems are then compared.

Source record↗

Photovoltaic conversion of laser energy

The Schottky barrier photovoltaic converter is suggested as an alternative to the p/n junction photovoltaic devices for the conversion of laser energy to electrical energy. The structure, current, output, and voltage output of the Schottky device are summarized. The more advanced concepts of the multilayer Schottky barrier cell and the AMOS solar cell are briefly considered.

Stirn, R. J.↗

Laser plasmadynamic energy conversion

The generation of electrons ions by interacting an intense laser beam with cesium vapor is considered. Theoretical calculation shows that the conversion efficiency is as high as 40 percent if the entire photon energy is utilized in ionizing the cesium vapor that is generated initially by the incoming laser beam. An output voltage is expected to be generated across two electrodes, one of which is the liquid cesium, by keeping the other electrode at a different work function. Evaluation of the laser plasmadynamic (LPD) converter was performed using pulsed ruby and Nd-glass lasers. Although the results obtained to date indicate an efficiency smaller than that of theoretical predictions, an unoptimized LPD converter did demonstrate the capability of converting laser energy at large power levels. The limitations in the performance may by due to converter geometry, the types of lasers used, and other limitations inherent to the cesium plasma.

Shimada, K.↗

Space-based solar power conversion and delivery systems study

Even at reduced rates of growth, the demand for electric power is expected to more than triple between now and 1995, and to triple again over the period 1995-2020. Without the development of new power sources and advanced transmission technologies, it may not be possible to supply electric energy at prices that are conductive to generalized economic welfare. Solar power is renewable and its conversion and transmission from space may be advantageous. The goal of this study is to assess the economic merit of space-based photovoltaic systems for power generation and a power relay satellite for power transmission. In this study, satellite solar power generation and transmission systems, as represented by current configurations of the Satellite Solar Station (SSPS) and the Power Relay Satellite (PRS), are compared with current and future terrestrial power generation and transmission systems to determine their technical and economic suitability for meeting power demands in the period of 1990 and beyond while meeting ever-increasing environmental and social constraints.

Source record↗

Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 1: Introduction and summary and general assumptions

Nine advanced energy conversion concepts using coal or coal-derived fuels are summarized. They are; (1) open-cycle gas turbines, (2) combined gas-steam turbine cycles, (3) closed-cycle gas turbines, (4) metal vapor Rankine topping, (5) open-cycle MHD; (6) closed-cycle MHD; (7) liquid-metal MHD; (8) advanced steam; and (9) fuel cell systems. The economics, natural resource requirements, and performance criteria for the nine concepts are discussed.

Beecher, D. T.↗

Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 2: Materials considerations

Extensive studies are presented which were carried out on materials behavior in nine advanced energy conversion systems employing coal and coal-derived fuels. The areas of materials behavior receiving particular attention in this regard are: (1) fireside corrosion and erosion in boiler and heat exchanger materials, (2) oxidation and hot corrosion of gas turbine materials, (3) liquid metal corrosion and mass transport, (4) high temperature steam corrosion, (5) compatability of materials with coal slag and MHD seed, (6) reaction of materials with impure helium, (7) allowable stresses for boiler and heat exchanger materials, (8) environmental effects on mechanical properties, and (9) liquid metal purity control and instrumentation. Such information was then utilized in recommending materials for use in the critical components of the power systems, and at the same time to identify materials problem areas and to evaluate qualitatively the difficulty of solving those problems. Specific materials recommendations for critical components of the nine advanced systems under study are contained in summary tables.

Thomas, D. E.↗

Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 5: Combined gas-steam turbine cycles

The energy conversion efficiency of gas-steam turbine cycles was investigated for selected combined cycle power plants. Results indicate that it is possible for combined cycle gas-steam turbine power plants to have efficiencies several point higher than conventional steam plants. Induction of low pressure steam into the steam turbine is shown to improve the plant efficiency. Post firing of the boiler of a high temperature combined cycle plant is found to increase net power but to worsen efficiency. A gas turbine pressure ratio of 12 to 1 was found to be close to optimum at all gas turbine inlet temperatures that were studied. The coal using combined cycle plant with an integrated low-Btu gasifier was calculated to have a plant efficiency of 43.6%, a capitalization of $497/kW, and a cost of electricity of 6.75 mills/MJ (24.3 mills/kwh). This combined cycle plant should be considered for base load power generation.

Amos, D. J.↗

Conversion of LARSYS III.1 to an IBM 370 computer

A software system for processing multispectral aircraft or satellite data (LARSYS) was designed and written at the Laboratory for Applications of Remote Sensing at Purdue University. This system, being implemented on an IBM 360/67 computer utilizing the Cambridge Monitor System, is of an interactive nature. TAMU LARSYS maintains the essential capabilities of Purdue's LARSYS. The machine configuration for which it has been converted is an IBM-compatible Amdahl 470V/6 computer utilizing the time sharing option of the currently implemented OS/VS2 Operating System. Due to TSO limitations, the NASA-JSC deliverable TAMU LARSYS is comprised of two parts. Part one is a TSO Control Card Checker for LARSYS control cards, and part two is a batch version of LARSYS. Used together, they afford most of the capabilities of the original LARSYS III.1. Additionally, two programs have been written by TAMU to support LARSYS processing. The first is an ERTS-to-MIST conversion program used to convert ERTS data to the LARSYS input form, the MIST tape. The second is a system runtable code which maintains tape/file location information for the MIST data sets.

Williams, G. N.↗

Diminiode thermionic conversion with 111-iridium electrodes

Preliminary data indicating thermionic-conversion potentialities for a 111-iridium emitter and collector spaced 0.2 mm apart are presented. These results comprise output densities of current and of power as functions of voltage for three sets of emitter, collector, and reservoir temperatures: 1553, 944, 561 K; 1605, 898, 533 K; and 1656, 1028, 586 K. For the 1605 K evaluation, estimates produced work-function values of 2.22 eV for the emitter and 1.63 eV for the collector with a 2.0-eV barrier index (collector work function plus interelectrode voltage drop) corresponding to the maximum output of 5.5 W/sq cm at 0.24 volt. The current, voltage curve for the 1656 K 111-iridium diminiode yields a 6.2 W/sq cm maximum at 0.25 volt and is comparable with the 1700 K envelope for a diode with an etched-rhenium emitter and a 0.025-mm electrode gap made by TECO and evaluated by NASA.

Koeger, E. W.↗

The NASA thermionic-conversion (TEC-ART) program

The current emphasis is on out-of-core thermionic conversion (TEC). The additional degrees of freedom offer new potentialities, but high-temperature material effects determine the level and lifetime of TEC performance: New electrodes not only raise power outputs but also maintain them regardless of emitter-vapor deposition on collectors. In addition, effective electrodes serve compatibly with hot-shell alloys. Space TEC withstands external and internal high-temperature vaporization problems, and terrestrial TEC tolerates hot corrosive atmospheres outside and near-vacuum inside. Finally, reduction of losses between converter electrodes is essential even though rather demanding geometries appear to be required for some modes of enhanced operation.

Morris, J. F.↗

Formation of fatty acids in photochemical conversions of saturated hydrocarbons

Abiogenic synthesis of fatty acids was studied in photochemical conversions of saturated hydrocarbons. It was shown that, in a hydrocarbon water CaCO3 suspension, the action of 254 nm UV rays caused the formation of fatty acids with a maximum number of carbon atoms in the chain not exceeding that in the initial hydrocarbon. Synthesis of acetic, propionic, butyric, valeric, caproic, enanthic and caprylic (in the case of octane) acids occurs in heptane water CaCO3 and octane water CaCO3 systems.

Telegina, T. A.↗

Ocean Thermal Energy Conversion (OTEC)

Energy Research and Development Administration research progress in Ocean Thermal Energy Conversion (OTEC) is outlined. The development program is being focused on cost effective heat exchangers; ammonia is generally used as the heat exchange fluid. Projected costs for energy production by OTEC vary between $1000 to $1700 per kW.

Lavi, A.↗

NASA thermionic-conversion program

Technological processes in out-of-core thermionic energy conversion are described. The emphasis was on high temperature electrode materials and system engineering of converter geometries to produce practical power densities.

Morris, J. F.↗