Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling system efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Heat pipes for terrestrial applications in dehumidification systems

A novel application of heat pipes which greatly enhances dehumidification performance of air-conditioning systems is presented. When an air-to-air heat pipe heat exchanger is placed between the warm return air and cold supply air streams of an air conditioner, heat is efficiently transferred from the return air to the supply air. As the warm return air precools during this process, it moves closer to its dew-point temperature. Therefore, the cooling system works less to remove moisture. This paper discusses the concept, its benefits, the challenges of incorporating heat pipes in an air-conditioning system, and the preliminary results from a field demonstration of an industrial application.

Khattar, Mukesh K.↗

Differential Absorption Lidar (DIAL) Measurements of Atmospheric Water Vapor Utilizing Robotic Aircraft

A new unpiloted air vehicle (UAV) based water vapor DIAL system will be described. This system is expected to offer lower operating costs, longer test duration and severe weather capabilities. A new high-efficiency, compact, light weight, diode-pumped, tunable Cr:LiSAF laser will be developed to meet the UAV payload weight and size limitations and its constraints in cooling capacity, physical size and payload. Similarly, a new receiver system using a single mirror telescope and an avalanche photo diode (APD) will be developed. Projected UAV parameters are expected to allow operation at altitudes up to 20 km, endurance of 24 hrs and speed of 400 km/hr. At these conditions measurements of water vapor at an uncertainty of 2-10% with a vertical resolution of 200 m and horizontal resolution of 10 km will be possible.

Hoang, Ngoc↗

Best Practices Guide for Energy-Efficient Data Center Design

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of Information Technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, on-site generation, and heat recovery.

Best Practices↗

Motor with Advanced Concepts for High power density and INtegrated cooling for Efficiency (MACHINE)

Raytheon Technologies Research Center (RTRC) is the central research and development (R&D) organization for RTX, and has extensive expertise in the design, modeling and analysis of high-performance electrical machines and thermal management for all its business units. The proposing team consists of researchers from RTRC and John Deere (JD), will be referred as “Team”. Each organization a has long track record of successful R&D of materials, manufacturing, components, and systems for energy efficiency applications. Motor power density and efficiency are limited by fundamental physical trade-offs between electromagnetics, thermal management, and structural design considerations. The team is proposing to utilize novel technologies and multi-physics design methods to develop a Motor with Advanced Concepts for High power density and INtegrated cooling for Efficiency (MACHINE), demonstrating an 8X improvement in power density.

33 ADVANCED PROPULSION SYSTEMS↗

Design, Project Execution, and Commissioning of the 1.8 K Superfluid Helium Refrigeration System for SRF Cryomodule Testing

The Fermilab Cryomodule Test Facility (CMTF) provides a test bed to measure the performance of superconducting radiofrequency (SRF) cryomodules (CM). These SRF components form the basic building blocks of future high intensity accelerators such as the International Linear Collider (ILC) and a Muon Collider. Linde Kryotechnik AG and Linde Cryogenics have designed, constructed and commissioned the superfluid helium refrigerator needed to support SRF component testing at the CMTF Facility. The hybrid refrigerator is designed to operate in a variety of modes and under a wide range of boundary conditions down to 1.8 Kelvin set by CM design. Special features of the refrigerator include the use of warm and cold compression and high efficiency turbo expanders.This paper gives an overview on the wide range of the challenging cooling requirements, the design, fabrication and the commissioning of the installed cryogenic system.

43 PARTICLE ACCELERATORS↗

A Review of Materials for Gas Turbines Firing Syngas Fuels

Following the extensive development work carried out in the 1990's, gas turbine combined-cycle (GTCC) systems burning natural gas represent a reliable and efficient power generation technology widely used in many parts of the world. A critical factor was that, in order to operate at the high turbine entry temperatures required for high efficiency operation, aero-engine technology, i.e., single-crystal blades, thermal barrier coatings, and sophisticated cooling techniques had to be rapidly scaled up and introduced into these large gas turbines. The problems with reliability that resulted have been largely overcome, so that the high-efficiency GTCC power generation system is now a mature technology, capable of achieving high levels of availability. The high price of natural gas and concern about emission of greenhouse gases has focused attention on the desirability of replacing natural gas with gas derived from coal (syngas) in these gas turbine systems, since typical systems analyses indicate that IGCC plants have some potential to fulfil the requirement for a zero-emissions power generation system. In this review, the current status of materials for the critical hot gas path parts in large gas turbines is briefly considered in the context of the need to burn syngas. A critical factor is that the syngas is a low-Btu fuel, and the higher mass flow compared to natural gas will tend to increase the power output of the engine. However, modifications to the turbine and to the combustion system also will be necessary. It will be shown that many of the materials used in current engines will also be applicable to units burning syngas but, since the combustion environment will contain a greater level of impurities (especially sulfur, water vapor, and particulates), the durability of some components may be prejudiced. Consequently, some effort will be needed to develop improved coatings to resist attack by sulfur-containing compounds, and also erosion.

01 COAL, LIGNITE, AND PEAT↗

Economic and environmental impacts of a non-traditional combined heat and power system for a discrete manufacturing facility

Combined heat and power (CHP) is an electricity generation strategy that benefits all sides with a vested interest in the nations’ energy future. The technology allows for the efficient production of electricity and heat, which in turn reduces the carbon footprint and energy costs of a facility with significant heat and electricity loads. This paper investigates, through a detailed dynamic simulation, how a highly non-traditional CHP facility can leverage those forces to economically and environmentally benefit. Four system configurations of a composites manufacturing facility, one existing and three proposed systems, including two CHP configurations and one combined cooling, heating, and power (CCHP) configuration are evaluated from both economic and environmental views. The three proposed configurations are based on a 600 kW microturbine as the primary mover. The dynamic model showed great potential to capture the dynamics of the system configurations including the dynamics of temperature, oven exhaust fraction, electrical efficiency, and overall efficiency of the system configurations. All 3 CHP systems have a payback period between 8.03 and 8.33 years. The proposed system configurations reduce up to 22.7% of the CO 2 emission compared to the existing facility, supplying the demands in a cleaner manner.

42 ENGINEERING↗

Engineering Nanoscale Thermal Transport: Size- and Spacing-Dependent Cooling of Nanostructures

Nanoscale thermal transport is becoming ever more technologically important with the development of next-generation nanoelectronics, nanomediated thermal therapies, and high efficiency thermoelectric devices. However, direct experimental measurements of nondiffusive heat flow in nanoscale systems are challenging, and first-principle models of real geometries are not yet computationally feasible. In recent work, we used ultrafast pulses of short-wavelength light to uncover a previously-unobserved regime of nanoscale thermal transport that occurs when the width and separation of heat sources are comparable to the mean free paths of the dominant heat-carrying phonons in the substrate. We now systematically compare thermal transport from gratings of metallic nanolines with different periodicities, on both silicon and fused-silica substrates, to map the entire nanoscale thermal transport landscape – from closely spaced through increasingly isolated to fully isolated heat-transfer regimes. By monitoring the surface profile dynamics with subangstrom sensitivity, we directly measure thermal transport from the nanolines into the substrate. This allows us to quantify for the first time how the nanoline separation significantly impacts thermal transport into the substrate, making it possible to reach efficiencies that are within a factor of 2 of the diffusive (i.e., thin-film) limit. We also show that partially isolated nanolines perform significantly worse, because cooling occurs in a regime that is intermediate between close-packed and fully isolated heat sources. This work thus confirms the surprising prediction that closely spaced nanoscale heat sources can cool more quickly than when far apart. In conclusion, these results show that our predictive model is validated by experiment over a broad parameter space, which is important for benchmarking theories that go beyond the Fourier model of heat diffusion, and for informed design of nanoengineered systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

System analysis of nuclear-assisted syngas production from coal - article no. 042901

A system analysis has been performed to assess the efficiency and carbon utilization of a nuclear-assisted coal gasification process. The nuclear reactor is a high-temperature helium-cooled reactor that is used primarily to provide power for hydrogen production via high-temperature electrolysis. The supplemental hydrogen is mixed with the outlet stream from an oxygen-blown coal gasifier to produce a hydrogen-rich gas mixture, allowing most of the carbon dioxide to be converted into carbon monoxide, with enough excess hydrogen to produce a syngas product stream with a hydrogen/carbon monoxide molar ratio of about 2:1. Oxygen for the gasifier is also provided by the high-temperature electrolysis process. The results of the analysis predict 90.5% carbon utilization with a syngas production efficiency (defined as the ratio of the heating value of the produced syngas to the sum of the heating value of the coal plus the high-temperature reactor heat input) of 64.4% at a gasifier temperature of 1866 K for the high-moisture-content lignite coal considered. Usage of lower moisture coals such as bituminous can yield carbon utilization approaching 100% and 70% syngas production efficiency.

01 COAL, LIGNITE, AND PEAT↗

WE-G-BRE-01: A High Power Nanotube X-Ray Microbeam Irradiator for Preclinical Brain Tumor Treatment

Purpose: Microbeam radiation therapy (MRT) is a new type of cancer treatment undergoing studies at various synchrotron facilities. The principle of MRT is using arrays of microscopically small, low-energy X-radiation for the treatment of various radio-resistant, deep-seated tumors. Our motivation is to develop a compact and inexpensive image guided MRT irradiator to use in the research lab setting. After a successful initial demonstration, here we report a second generation carbon nanotube (CNT) cathode based MRT tube, capable of producing multiple microbeam lines with an anticipated dose rate of 11 Gy/min per line. Methods: The system uses multiple line CNT source arrays to generate multiple focal lines on the anode. The increase in dose-rate, compared to our first generation system, is achieved by increasing the operating voltage from 160 kVp to 225kVp, adding multiple simultaneous focal lines on the anode, and a more efficient cooling mechanism using a 6kW oil-cooled anode. Results: This work will present the design and development process, challenges and solutions to meeting operating specifications, and the final design of the tube and collimator, along with optimization and stabilization of its use. A detailed characterization of its capabilities will be included with a comprehensive measurement of its X-ray focal line dimensions, an evaluation of its collimator alignment and microbeam dimensions, and phantom-based quantification of its dosimetric output. Conclusion: The development of a second generation, compact, multiple line MRT device using carbon nanotube (CNT) cathode based X-ray technology and a novel oil cooled anode design is presented here. With this new source, we are capable of delivering a total microbeam radiation dose comparable to the low end of the synchrotron based MRT systems for small animal brain tumor models.

60 APPLIED LIFE SCIENCES↗

A Continuous Adiabatic Demagnetization Refrigerator for Use with Mechanical Coolers

We have begun developing an adiabatic demagnetization refrigerator (ADR) which can produce continuous cooling at temperatures of 50 mK or lower, with high cooling power (goal of 10 PW). The design uses multiple stages to cascade heat from a continuously-cooled stage up to a heat sink. The serial arrangement makes it possible to add stages to extend the operating range to lower temperature, or to raise the heat rejection temperature. Compared to conventional single-shot ADRS, this system achieves higher cooling power per unit mass and is able to reject its heat at a more uniform rate. For operation with a mechanical cryocooler, this latter feature stabilizes the heat sink temperature and allows both the ADR and cryocooler to operate more efficiently. The ADR is being designed to operate with a heat sink as warm as 10-12 K to make it compatible with a wide variety of mechanical coolers as part of a versatile, cryogen-free low temperature cooling system. A two-stage system has been constructed and a proof-of-principle demonstration was conducted at 100 mK. Details of the design and test results, as well as the direction of future work, are discussed.

Shirron, P.↗

Membrane-based Ionic Liquid Absorption System for Ultra-Efficient Dehumidification and Heating

The project team – comprising the University of Florida (UF), GTI Energy, and Modine Manufacturing – sought to develop a highly efficient heat-powered absorption cycle with combined dehumidification and heat pumping. This DOE-supported project advanced the technology from a TRL of 3 to 6, culminating in the development of a 1,000 CFM system. Key innovations implemented in the system addressed the low efficiency, size, cost, and reliability challenges of conventional absorption cycles. Specifically, the system was enabled by: (1) a semi-open cycle that allowed simultaneous dehumidification and heat recovery, (2) non-crystallizing ionic liquids (ILs) that enabled “double-effect” operation at elevated temperatures without the need for costly control equipment, (3) a compact membrane-based absorber that confined the IL and directly cooled it to achieve low dew points, and (4) a novel, highly integrated desorber–condenser assembly that reduced size, weight, and cost. The technology was developed with commercial HVAC applications in mind, particularly for separate sensible and latent cooling (SSLC), an innovation aimed at achieving independent and more efficient humidity control.

42 ENGINEERING↗

Shape optimization and fluid control of near isothermal compressor for transcritical carbon dioxide cycle

The compressor holds great promise for enhanced energy efficiency over a wide range of vapor compression systems (VCS). However, the majority of them focused on liquid refrigerant injection or inter-stage cooling technologies to improve heat transfer. Increasing the heat transfer area provides another perspective to promote heat dissipation, which commonly involves shape optimization whilst bringing some limitations, mainly from the manufacturing side. To fill the research gap, this paper compares the performance of isothermal compressors under different compression chamber shapes and chamber connection configurations. Additionally, the fluid control of the liquid piston was combined with shape optimization to explore the potential for further heat transfer enhancement. The simulation results have demonstrated that the COP improvements can reach up to 9% compared with the baseline case by optimizing the chamber shape and properly controlling the liquid piston speed, which provides a guideline for designing and customizing the isothermal compression chamber.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and Reducing Plug and Process Loads in Retail Buildings (Brochure)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in retail spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and Reducing Plug and Process Loads in Office Buildings (Brochure)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retail Buildings: Assessing and Reducing Plug and Process Loads in Retail Buildings (Fact Sheet)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in retail spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Office Buildings: Assessing and Reducing Plug and Process Loads in Office Buildings (Fact Sheet)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗