Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dark Matter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Dark matter raining on DUNE and other large volume detectors

Direct detection is a powerful means of searching for particle physics evidence of dark matter (DM) heavier than about a GeV with o(kiloton) volume, low-threshold detectors. In many scenarios, some fraction of the DM may be boosted to large velocities enhancing and generally modifying possible detection signatures. We investigate the scenario where 100% of the DM is boosted at the Earth due to new attractive long-range forces. This leads to two main improvements in detection capabilities: (1) the large boost allows for detectable signatures of DM well below a GeV at large-volume neutrino detectors, such as DUNE, Super-K, Hyper-K, and JUNO, as possible DM detectors, and (2) the flux at the Earth’s surface is enhanced by a focusing effect. In addition, the model leads to a significant anisotropy in the signal with the DM flowing dominantly vertically at the Earth’s surface instead of the typical approximately isotropic DM signal. We develop the theory behind this model and also calculate realistic constraints using a detailed GENIE simulation of the signal inside detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phonon-mediated high-voltage detector with background rejection for low-mass dark matter and reactor coherent neutrino scattering experiments

We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. Furthermore, this new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for dark matter in events with missing transverse momentum and a Higgs boson decaying into two photons in pp collisions at $$ \sqrt{s} $$ = 13 TeV with the ATLAS detector

A search for dark-matter particles in events with large missing transverse momentum and a Higgs boson candidate decaying into two photons is reported. The search uses 139 fb - 1 of proton-proton collision data collected at $$ \sqrt{s} $$ s = 13 TeV with the ATLAS detector at the CERN LHC between 2015 and 2018. No significant excess of events over the Standard Model predictions is observed. The results are interpreted by extracting limits on three simplified models that include either vector or pseudoscalar mediators and predict a final state with a pair of dark-matter candidates and a Higgs boson decaying into two photons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for dark matter produced in association with a single top quark and an energetic W boson in $\sqrt{s}=$ 13 TeV $pp$ collisions with the ATLAS detector

This paper presents a search for dark matter, $χ$, using events with a single top quark and an energetic W boson. The analysis is based on proton–proton collision data collected with the ATLAS experiment at $\sqrt{s}=$ 13 TeV during LHC Run 2 (2015–2018), corresponding to an integrated luminosity of 139 fb -1 . The search considers final states with zero or one charged lepton (electron or muon), at least one $b$-jet and large missing transverse momentum. In addition, a result from a previous search considering two-charged-lepton final states is included in the interpretation of the results. The data are found to be in good agreement with the Standard Model predictions and the results are interpreted in terms of 95% confidence-level exclusion limits in the context of a class of dark matter models involving an extended two Higgs-doublet sector together with a pseudoscalar mediator particle. The search is particularly sensitive to on-shell pro duction of the charged Higgs boson state, $H$ ± , arising from the two-Higgs-doublet mixing, and its semi-invisible decays via the mediator particle, $a$: $H$ ± → $W$ ± $a$(→ $χ$ $χ$). Signal models with $H$ ± masses up to 1.5 TeV and a masses up to 350 GeV are excluded assuming a tan $β$ value of 1. For masses of a of 150 (250) GeV, tan $β$ values up to 2 are excluded for $H$ ± masses between 200 (400) GeV and 1.5 TeV. Signals with tan $β$ values between 20 and 30 are excluded for $H$ ± masses between 500 and 800 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmological structure formation and soliton phase transition in fuzzy dark matter with axion self-interactions

Herein we investigate cosmological structure formation in fuzzy dark matter (FDM) with the attractive self-interaction (SI) with numerical simulations. Such a SI would arise if the FDM boson were an ultra-light axion, which has a strong CP symmetry-breaking scale (decay constant). Although weak, the attractive SI may be strong enough to counteract the quantum ‘pressure’ and alter structure formation. We find in our simulations that the SI can enhance small-scale structure formation, and soliton cores above a critical mass undergo a phase transition, transforming from dilute to dense solitons.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid neutron star cooling triggered by dark matter

ABSTRACT We study the effect of asymmetric fermionic dark matter (DM) on the thermal evolution of neutron stars (NSs). No interaction between DM and baryonic matter is assumed, except the gravitational one. Using the two-fluid formalism, we show that DM accumulated in the core of a star pulls inwards the outer baryonic layers of the star, increasing the baryonic density in the NS core. As a result, it significantly affects the star’s thermal evolution by triggering an early onset of the direct Urca (DU) process and modifying the photon emission from the surface caused by the decrease of the radius. Thus, due to the gravitational pull of DM, the DU process becomes kinematically allowed for stars with lower masses. Based on these results, we discuss the importance of NS observations at different distances from the Galactic Centre. Since the DM distribution peaks towards the Galactic Centre, NSs in this region are expected to contain higher DM fractions that could lead to a different cooling behavior.

Ávila, Afonso (ORCID:000000028880039X)↗

Dark Matter Candidates of a Very Low Mass

We review dark matter (DM) candidates of a very low mass appearing in the window below the traditional weakly interacting massive particle (m χ ≲ 10 GeV) and extending down to m χ ≳ 1 meV, somewhat below the mass limit at which DM becomes wavelike. Such candidates are motivated by hidden sectors such as hidden valleys, which feature hidden forces and rich dynamics, but have evaded traditional accelerator searches for New Physics because of their relatively weak coupling to the Standard Model (SM). Such sectors can still be detected through dedicated low-energy colliders, which, through their intense beams, can have sensitivity to smaller couplings, or through astrophysical observations of the evolution of DM halos and stellar structures, which, through the Universe's epochs, can be sensitive to small DM interactions. We also consider mechanisms whereby the DM abundance is fixed through the interaction with the SM, which directly motivates the search for light DM in terrestrial experiments. The bulk of this review is dedicated to the new ideas that have been proposed for direct detection of such DM candidates of a low mass through nuclear recoils, electronic excitations, or collective modes such as phonons and magnons. The rich tapestry of materials and modes in the condensed matter landscape is reviewed along with specific prospects for detection.

Physics↗

Search for low mass WIMP dark matter with DarkSide-50

DarkSide-50 is a direct dark matter detection experiment at Laboratori Nazionali del Gran Sasso that uses argon as the target material. Exploiting the ionization signal from a dual-phase time projection chamber filled with low-radioactivity argon, it has set the most stringent exclusion limit on WIMPs with a mass of few \mathrm{GeV}/c^2 G e V / c 2 . A new analysis has recently been carried out with a larger exposure, profiting from an improved understanding of the detector response and background model. An improvement of about a factor 10 in sensitivity is expected for a WIMP mass of 2 GeV/c ^2 2 .

Kimura, Masato↗

How accurately can we detect the splashback radius of dark matter haloes and its correlation with accretion rate?

ABSTRACT The splashback radius (Rsp) of dark matter haloes has recently been detected using weak gravitational lensing and cross-correlations with galaxies. However, different methods have been used to measure Rsp and to assess the significance of its detection. In this paper, we use simulations to study the precision and accuracy to which we can detect the splashback radius with 3D density, 3D subhalo, and weak lensing profiles. We study how well various methods and tracers recover Rsp by comparing it with the value measured directly from particle dynamics. We show that estimates of Rsp from density and subhalo profiles correspond to different percentiles of the underlying Rsp distribution of particle orbits. At low accretion rates, a second caustic appears and can bias results. Finally, we show that upcoming lensing surveys may be able to constrain the Rsp–Γdyn relation directly.

79 ASTRONOMY AND ASTROPHYSICS↗

Milky Way white dwarfs as sub-GeV to multi-TeV dark matter detectors

Here, we show that Milky Way white dwarfs are excellent targets for dark matter (DM) detection. Using Fermi and H.E.S.S. Galactic center gamma-ray data, we investigate sensitivity to DM annihilating within white dwarfs into long-lived or boosted mediators and producing detectable gamma rays. Depending on the Galactic DM distribution, we set new constraints on the spin-independent scattering cross section down to 10 -45 -10 -41 cm 2 in the sub-GeV DM mass range, which is multiple orders of magnitude stronger than existing limits. For a generalized NFW DM profile, we find that our white dwarf constraints exceed spin-independent direct detection limits across most of the sub-GeV to multi-TeV DM mass range, achieving sensitivities as low as about 10 -46 cm 2 . In addition, we improve earlier versions of the DM capture calculation in white dwarfs, by including the low-temperature distribution of nuclei when the white dwarf approaches crystallization. This yields smaller capture rates than previously calculated by a factor of a few up to two orders of magnitude, depending on white dwarf size and the astrophysical system.

79 ASTRONOMY AND ASTROPHYSICS↗

The data acquisition system of the LZ dark matter detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. Furthermore, the hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Constraints on dark matter with future MeV gamma-ray telescopes

A number of new balloon or space-based γ -ray observatories have been proposed to close a “MeV gap” in sensitivity to γ rays in the MeV–GeV energy band. One aspect of the science case for these instruments is their ability to constrain or discover decaying or annihilating dark matter. In this work, we forecast the sensitivity of these instruments for dark matter annihilation or decay for a range of possible Standard Model final states and compare to existing bounds. Published by the American Physical Society 2025

O’Donnell, Kayla E. (ORCID:0009000532266844)↗

First Measurement of Discrimination between Helium and Electron Recoils in Liquid Xenon for Low-Mass Dark Matter Searches

We report the first measurement of discrimination between low-energy helium recoils and electron recoils in liquid xenon. This result is relevant to proposed low-mass dark matter searches which seek to dissolve light target nuclei in the active volume of liquid-xenon time projection chambers. Low-energy helium recoils were produced by degrading α particles from Po 210 with a gold foil situated on the cathode of a liquid xenon time-projection chamber. The resulting population of helium recoil events is well separated from electron recoils and is also offset from the expected position of xenon nuclear recoil events. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigating Electro-Nuclear Interactions in a New Dark Matter Search

Electro-nuclear (EN) interactions are interactions in which an incident electron collides with a nucleus, scattering the electron and creating byproduct particles. Such interactions are of interest to neutrino physicists, who use EN interactions to inform model building of neutrino-nucleus interactions. The Light Dark Matter Experiment (LDMX) is a small-scale, fixed-target, electron beam experiment which seeks to probe for dark matter and mediator particle production in the sub-GeV mass region. The 8GeV LDMX electron beam will serve as an opportunity to study electro-nuclear interactions in their final states in the multi-GeV region. LDMX’s missing energy trigger however, will not be sufficient to efficiently capture EN interactions. An additional trigger needs to be created. Using simulated background events, including EN interactions, for the LDMX experiment, a trigger on momentum was developed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗