Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Skopi: a simulation package for diffractive imaging of noncrystalline biomolecules

X-ray free-electron lasers (XFELs) have the ability to produce ultra-bright femtosecond X-ray pulses for coherent diffraction imaging of biomolecules. While the development of methods and algorithms for macromolecular crystallography is now mature, XFEL experiments involving aerosolized or solvated biomolecular samples offer new challenges in terms of both experimental design and data processing. Skopi is a simulation package that can generate single-hit diffraction images for reconstruction algorithms, multi-hit diffraction images of aggregated particles for training machine learning classifiers using labeled data, diffraction images of randomly distributed particles for fluctuation X-ray scattering algorithms, and diffraction images of reference and target particles for holographic reconstruction algorithms. Skopi is a resource to aid feasibility studies and advance the development of algorithms for noncrystalline experiments at XFEL facilities.

59 BASIC BIOLOGICAL SCIENCES↗

Simulations of X-ray diffraction of shock-compressed single-crystal tantalum with synchrotron undulator sources

Polychromatic synchrotron undulator X-ray sources are useful for ultrafast single-crystal diffraction under shock compression. Here, simulations of X-ray diffraction of shock-compressed single-crystal tantalum with realistic undulator sources are reported, based on large-scale molecular dynamics simulations. Purely elastic deformation, elastic–plastic two-wave structure, and severe plastic deformation under different impact velocities are explored, as well as an edge release case. Transmission-mode diffraction simulations consider crystallographic orientation, loading direction, incident beam direction, X-ray spectrum bandwidth and realistic detector size. Diffraction patterns and reciprocal space nodes are obtained from atomic configurations for different loading (elastic and plastic) and detection conditions, and interpretation of the diffraction patterns is discussed.

Tang, M. X.↗

Femtosecond X-ray Diffraction From Two-Dimensional Protein Crystals

Here we present femtosecond x-ray diffraction patterns from two-dimensional (2-D) protein crystals using an x-ray free electron laser (XFEL). To date it has not been possible to acquire x-ray diffraction from individual 2-D protein crystals due to radiation damage. However, the intense and ultrafast pulses generated by an XFEL permits a new method of collecting diffraction data before the sample is destroyed. Utilizing a diffract-before-destroy methodology at the Linac Coherent Light Source, we observed Bragg diffraction to better than 8.5 Å resolution for two different 2-D protein crystal samples that were maintained at room temperature. These proof-of-principle results show promise for structural analysis of both soluble and membrane proteins arranged as 2-D crystals without requiring cryogenic conditions or the formation of three-dimensional crystals.

36 MATERIALS SCIENCE↗

Algorithms in Diffraction Profile Analysis

This chapter introduces several approaches to crystallographic structure refinement from diffraction profile data including the Rietveld method, global optimization methods, and Bayesian modeling. First, the Rietveld method and related nonlinear least squares approaches to analyzing diffraction profiles are briefly discussed. We then review the most common algorithms within global optimization as alternative methods of structure solution: grid search, simulated annealing, and genetic algorithms. As the Rietveld method is the standard tool for analyzing diffraction profile data, we catalogue its challenges and limitations. A Bayesian approach to diffraction profile analysis is presented as an alternative, along with several sampling algorithms including Gibbs sampling, variants of Metropolis sampling, Hamiltonian Monte Carlo, and approximate Bayesian computing. These sampling algorithms are applied to the fitting of a neutron diffraction profile from a National Institute of Standards and Technology silicon standard reference material, and their results are compared.

Singh, Susheela↗

To image, or not to image: class-specific diffractive cameras with all-optical erasure of undesired objects

Abstract Privacy protection is a growing concern in the digital era, with machine vision techniques widely used throughout public and private settings. Existing methods address this growing problem by, e.g., encrypting camera images or obscuring/blurring the imaged information through digital algorithms. Here, we demonstrate a camera design that performs class-specific imaging of target objects with instantaneous all-optical erasure of other classes of objects. This diffractive camera consists of transmissive surfaces structured using deep learning to perform selective imaging of target classes of objects positioned at its input field-of-view. After their fabrication, the thin diffractive layers collectively perform optical mode filtering to accurately form images of the objects that belong to a target data class or group of classes, while instantaneously erasing objects of the other data classes at the output field-of-view. Using the same framework, we also demonstrate the design of class-specific permutation and class-specific linear transformation cameras, where the objects of a target data class are pixel-wise permuted or linearly transformed following an arbitrarily selected transformation matrix for all-optical class-specific encryption, while the other classes of objects are irreversibly erased from the output image. The success of class-specific diffractive cameras was experimentally demonstrated using terahertz (THz) waves and 3D-printed diffractive layers that selectively imaged only one class of the MNIST handwritten digit dataset, all-optically erasing the other handwritten digits. This diffractive camera design can be scaled to different parts of the electromagnetic spectrum, including, e.g., the visible and infrared wavelengths, to provide transformative opportunities for privacy-preserving digital cameras and task-specific data-efficient imaging.

47 OTHER INSTRUMENTATION↗

Controlling the sign of chromatic dispersion in diffractive optics with dielectric metasurfaces

Diffraction gratings disperse light in a rainbow of colors with the opposite order than refractive prisms, a phenomenon known as negative dispersion. While refractive dispersion can be controlled via material refractive index, diffractive dispersion is fundamentally an interference effect dictated by geometry. Here we show that this fundamental property can be altered using dielectric metasurfaces, and we experimentally demonstrate diffractive gratings and focusing mirrors with positive, zero, and hyper-negative dispersion. These optical elements are implemented using a reflective metasurface composed of dielectric nano-posts that provide simultaneous control over phase and its wavelength derivative. In addition, as a first practical application, we demonstrate a focusing mirror that exhibits a five-fold reduction in chromatic dispersion, and thus an almost three-times increase in operation bandwidth compared with a regular diffractive element. In conclusion, this concept challenges the generally accepted dispersive properties of diffractive optical devices and extends their applications and functionalities.

42 ENGINEERING↗

Liquid X-ray diffraction on the NIF: Phase transitions into and within the liquid phase

Traditional Hugoniot velocity measurements have always been severely limited in their ability to determine structural properties of materials. However, the advent of x-ray diffraction1 on laser compression experiments is recently allowing unprecedented opportunities to directly measure the in-situ structure of compressed materials. Unfortunately, much of the phase space accessible to shock compression in general and on the NIF specifically is in the liquid or fluid phases, so that traditional Bragg diffraction cannot be used. This proposal seeks beam time to address this issue by developing a reliable capability for liquid diffraction on the NIF. There are currently three primary applications of liquid x-ray diffraction in highpressure science. First, the substitution of liquid diffuse scattering for Bragg scattering is the preferred method for documenting melting in laser-heated DAC experiments.2-4 Second, the search for and observation of liquid-liquid phase transitions requires a direct structural diagnostic.5 And finally, great progress has been achieved in measuring static-high-pressure liquid diffraction in diamond-anvil cells (DACs) in the past decade. We propose to use our recent successes on Omega and Omega EP on diffraction of iron and diamond to 5 Mbar to design and perform our NIF experiments. The critical advance in these experiments is the use of a diamond-sandwich target.

42 ENGINEERING↗

Materials Characterization Techniques Lecture Series: X-Ray Diffraction, A Summary of LANL's Materials Capabilities in MPA-11 [Slides]

This presentation provides an overview on X-Ray Diffraction (XRD) to cover background, fundamentals, limitations, best practices, applications, analysis, software, and resources. To summarize: XRD is a great tool for characterizing solid crystalline samples. X-Rays are E-Mag radiation and generate diffraction profiles based on the phase of the sample. Diffraction patterns are unique to the phase of the sample. Powder diffraction gives us better diffraction profiles. We can obtain both qualitative and quantitative data. Analysis requires us to know a little about our sample and a lot about our diffractometer.

36 MATERIALS SCIENCE↗

A new method for focusing and imaging X-rays and gamma-rays with diffraction crystals

Bent diffraction crystals in which the intercrystalline-plane spacing is varied as a function of position in the crystal are used to focus monochromatic radiation from a point source or parallel beam down to a point image. Conversely, radiation from a point source can be focused into an outgoing parallel beam. The Bragg angle for diffraction of monochromatic radiation will now vary as a function of position in the crystal and this new degree of freedom is used to obtain focusing and imaging of the diffracted beam. This approach to focusing and imaging is applied to the design of a large-area, high resolution X-ray telescope that is also a high resolution monochromator with the unique feature that the width of the energy increment that is diffracted can be controlled and varied during the operation of the instrument. The field can be scanned with a wide energy increment and then switched to a narrow energy increment for the high resolution work. Both transmission and reflection type diffraction crystals can be used.

Smither, R. K.↗

Real-time X-ray Diffraction: Applications to Materials Characterization

With the high speed growth of materials it becomes necessary to develop measuring systems which also have the capabilities of characterizing these materials at high speeds. One of the conventional techniques of characterizing materials was X-ray diffraction. Film, which is the oldest method of recording the X-ray diffraction phenomenon, is not quite adequate in most circumstances to record fast changing events. Even though conventional proportional counters and scintillation counters can provide the speed necessary to record these changing events, they lack the ability to provide image information which may be important in some types of experiment or production arrangements. A selected number of novel applications of using X-ray diffraction to characterize materials in real-time are discussed. Also, device characteristics of some X-ray intensifiers useful in instantaneous X-ray diffraction applications briefly presented. Real-time X-ray diffraction experiments with the incorporation of image X-ray intensification add a new dimension in the characterization of materials. The uses of real-time image intensification in laboratory and production arrangements are quite unlimited and their application depends more upon the ingenuity of the scientist or engineer.

Rosemeier, R. G.↗

Structural anomalies in undoped Gallium Arsenide observed in high resolution diffraction imaging with monochromatic synchrotron radiation

Novel, streak-like disruption features restricted to the plane of diffraction have recently been observed in images obtained by synchrotron radiation diffraction from undoped, semi-insulating gallium arsenide crystals. These features were identified as ensembles of very thin platelets or interfaces lying in (110) planes, and a structural model consisting of antiphase domain boundaries was proposed. We report here the other principal features observed in high resolution monochromatic synchrotron radiation diffraction images: (quasi) cellular structure; linear, very low-angle subgrain boundaries in (110) directions, and surface stripes in a (110) direction. In addition, we report systematic differences in the acceptance angle for images involving various diffraction vectors. When these observations are considered together, a unifying picture emerges. The presence of ensembles of thin (110) antiphase platelet regions or boundaries is generally consistent not only with the streak-like diffraction features but with the other features reported here as well. For the formation of such regions we propose two mechanisms, operating in parallel, that appear to be consistent with the various defect features observed by a variety of techniques.

Steiner, B.↗

Structural anomalies in undoped gallium arsenide observed in high-resolution diffraction imaging with monochromatic synchrotron radiation

Novel, streak-like disruption features restricted to the plane of diffraction have recently been observed in images obtained by synchrotron radiation diffraction from undoped, semi-insulating gallium arsenide crystals. These features were identified as ensembles of very thin platelets or interfaces lying in (110) planes, and a structural model consisting of antiphase domain boundaries was proposed. We report here the other principal features observed in high resolution monochromatic synchrotron radiation diffraction images: (quasi) cellular structure; linear, very low-angle subgrain boundaries in (110) directions, and surface stripes in a (110) direction. In addition, we report systematic differences in the acceptance angle for images involving various diffraction vectors. When these observations are considered together, a unifying picture emerges. The presence of ensembles of thin (110) antiphase platelet regions or boundaries is generally consistent not only with the streak-like diffraction features but with the other features reported here as well. For the formation of such regions we propose two mechanisms, operating in parallel, that appear to be consistent with the various defect features observed by a variety of techniques.

Steiner, B.↗

Correcting for diffraction in the far-infrared reflectance measurement of rough surfaces

The manner in which diffraction can increase the reflectance measured from very rough surfaces is shown by observations of diffracted light within the instrument profile of a far-IR reflectometer system. A correction to the calibration signal based on numerical integration of the diffracted part of the instrument profile is described. Diffraction correction factors as large as 2.94 have been found with small optics at long wavelength (630 microns). The effect of diffraction on diffuse reflectance measurements of a very rough perfect reflector is shown at wavelengths from 56 to 200 microns.

Smith, Sheldon M.↗

Nondestructive evaluation of fatigue damage in aluminum 2024 by x-ray diffraction

Aluminum alloys are widely used in the automobile and aerospace industries. This is due to their attractive low density-high modulus and low density-high strength characteristics. Unfortunately, cyclic stress-strain deformations alter the microstructure of aluminum alloys when they are placed into service. These structural changes can lead to fatigue damage and ultimately service failure. Since x-ray diffraction analysis is known to be a sensitive nondestructive indicator of structural changes due to deformations, this technique is being used to evaluate changes in the microstructure of cycled aluminum 2024 commercial alloys. Line shapes, widths, and positions in an x-ray diffraction pattern depend on microstructural properties such as grain size, grain orientation, residual stress, microstrain, etc. Changes in the microstructure due to fatigue will appear as changes in the diffraction pattern. One parameter used to characterize a reflection in a diffraction pattern is the full width at half maximum (FWHM). Preliminary x-ray diffraction results on cycled Al 2024 indicate that the (111) and (222) reflections of the matrix phase do not show any variations in the FWHM due to an increase in the fatigue cycles. However, the FWHM of the (200) and (400) reflections of the same phase unexpectedly showed a dramatic decrease. These results can be interpreted as due to the relaxation of some initial nonuniform residual stresses in the matrix phase lattice. Further work is in progress to evaluate the FWHM of the second phase of the cycled alloys.

Ferguson, Milton W.↗

Multipath analysis diffraction calculations

This report describes extensions of the Kirchhoff diffraction equation to higher edge terms and discusses their suitability to model diffraction multipath effects of a small satellite structure. When receiving signals, at a satellite, from the Global Positioning System (GPS), reflected signals from the satellite structure result in multipath errors in the determination of the satellite position. Multipath error can be caused by diffraction of the reflected signals and a method of calculating this diffraction is required when using a facet model of the satellite. Several aspects of the Kirchhoff equation are discussed and numerical examples, in the near and far fields, are shown. The vector form of the extended Kirchhoff equation, by adding the Larmor-Tedone and Kottler edge terms, is given as a mathematical model in an appendix. The Kirchhoff equation was investigated as being easily implemented and of good accuracy in the basic form, especially in phase determination. The basic Kirchhoff can be extended for higher accuracy if desired. A brief discussion of the method of moments and the geometric theory of diffraction is included, but seems to offer no clear advantage in implementation over the Kirchhoff for facet models.

Statham, Richard B.↗

Maximizing Macromolecule Crystal Size for Neutron Diffraction Experiments

A challenge in neutron diffraction experiments is growing large (greater than 1 cu mm) macromolecule crystals. In taking up this challenge we have used statistical experiment design techniques to quickly identify crystallization conditions under which the largest crystals grow. These techniques provide the maximum information for minimal experimental effort, allowing optimal screening of crystallization variables in a simple experimental matrix, using the minimum amount of sample. Analysis of the results quickly tells the investigator what conditions are the most important for the crystallization. These can then be used to maximize the crystallization results in terms of reducing crystal numbers and providing large crystals of suitable habit. We have used these techniques to grow large crystals of Glucose isomerase. Glucose isomerase is an industrial enzyme used extensively in the food industry for the conversion of glucose to fructose. The aim of this study is the elucidation of the enzymatic mechanism at the molecular level. The accurate determination of hydrogen positions, which is critical for this, is a requirement that neutron diffraction is uniquely suited for. Preliminary neutron diffraction experiments with these crystals conducted at the Institute Laue-Langevin (Grenoble, France) reveal diffraction to beyond 2.5 angstrom. Macromolecular crystal growth is a process involving many parameters, and statistical experimental design is naturally suited to this field. These techniques are sample independent and provide an experimental strategy to maximize crystal volume and habit for neutron diffraction studies.

Judge, R. A.↗

Phase Sensitive X-Ray Diffraction Imaging Study of Protein Crystals

The study of defects and growth of protein crystals is of importance in providing a fundamental understanding of this important category of systems and the rationale for crystallization of better ordered crystals for structural determination and drug design. Yet, as a result of the extremely weak scattering power of x-rays in protein and other biological macromolecular crystals, the extinction lengths for those crystals are extremely large and, roughly speaking, of the order of millimeters on average compared to the scale of micrometers for most small molecular crystals. This has significant implication for x-ray diffraction and imaging study of protein crystals, and presents an interesting challenge to currently available x-ray analytical techniques. We proposed that coherence-based phase sensitive x-ray diffraction imaging could provide a way to augment defect contrast in x-ray diffraction images of weakly diffracting biological macromolecular crystals. I shall examine the principles and ideas behind this approach and compare it to other available x-ray topography and diffraction methods. I shall then present some recent experimental results in two model protein systems-cubic apofemtin and tetragonal lysozyme crystals to demonstrate the capability of the coherence-based imaging method in mapping point defects, dislocations, and the degree of perfection of biological macromolecular crystals with extreme sensitivity. While further work is under way, it is intended to show that the observed new features have yielded important information on protein crystal perfection and nucleation and growth mechanism otherwise unobtainable.

Hu, Z. W.↗

Micron-Accurate Laser Fresnel-Diffraction Ranging System

Two versions of an optoelectronic system undergoing development are depicted. The system is expected to be capable of measuring a distance between 2 and 10 m with an error of no more than 1 micrometer. The system would be designed to exploit Fresnel diffraction of a laser beam. In particular, it would be designed to take advantage of the fact that a Fresnel diffraction pattern is ultrasensitive to distance. The two versions would differ in the following respects: In version 1, the focus of the telescope would be in the Fresnel region, and the telescope would have a small depth of focus. As a consequence, the Fresnel pattern would be imaged directly onto the photodetector array; in version 2, a multielement lens module would displace the Fresnel region from the vicinity of the pinhole to the vicinity of the optical receiver. As the distance to be measured varied, the location of the receiver relative to the displaced Fresnel-diffraction region would vary, thereby causing the Fresnel diffraction pattern on the focal plane to vary. The multielement lens module would also correct for aberrations. The processing of the digitized Fresnel diffraction pattern in the computer might be accelerated by using only parts of the pattern or even only one small part - the central pixel. As the distance from the pinhole increased, the central pixel would rapidly cycle between maximum and minimum light intensity. This in itself would not be sufficient to uniquely determine the distance. However, by varying the size of the pinhole or the wavelength of the laser, one could obtain a second cycle of variation of intensity that, in conjunction with the first cycle, could enable a unique determination of distance. Alternatively, for a single wavelength and a single pinhole size, it should suffice to consider the data from only two different key pixels in the Fresnel pattern.

Lehner, David↗