Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVACUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A fixed tilt solar collector employing reversible vee-through reflectors and evaluated tube receivers for solar heating and cooling systems

The Vee-Trough/Evacuated Tube Collector (VTETC) was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrators, and the quasi-steady state thermal performance of the evacuated tube receivers. Tests were run to verify the mathematical analyses. Back-silvered glass mirror, Alzak, Aluminized Teflon, and Kinglux (electropolished aluminum reflectors) were tested. Additional tests were run at temperatures ranging from 80 to 190 C (176-374 F). For the glass mirror reflectors, peak efficiencies, based on aperture area and operating temperatures of 125 C (257 F), were over 40%. Efficiencies of about 40% were observed at temperatures of 150 C (302 F) and 30% at 175 C (347 F). Test data for several days, predicted daily useful heats, and efficiency values are presented for a full year. These theoretical values were then compared with actual data points for the same temperature range.

Selcuk, M. K.↗

Multiwall TPS

A study of multiwall TPS as an alternative to LRSI for the space shuttle indicated that vented multiwall, with foil thicknesses limited to those used in multiwall fabricated to date, is some what heavier than LRSI. With reduced foil thicknesses, multiwall TPS may equal the weight of LRSI. Metallic conduction through multiwall TPS transfered less heat than gas conduction or radiation. Radiation heat transfer was greatest at high temperatures; however, the number of layers selected can significantly reduce radiation. At low-to-intermediate temperatures, gas conduction transfered the most heat through multiwall TPS. Gas conduction may be eliminated by evacuation of panels. Oxidation rates required a trade of foil thickness against life.

Jackson, L. R.↗

Solar heating and hot water system installed at Cherry Hill, New Jersey

The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.

Source record↗

Airport flammability, full scale fire tests

The primary objectives of the fire tests are: (1) conduct full scale test with 737 fuselages by the end of 1980; (2) demonstrate evacuation time increase to five minutes minimum; (3) show that exterior fire will not penetrate an intact cabin for five minutes; (4) show that closed cabin will not have excess smoke or temperatures above 400 F; and (5) demonstrate that fire in cabin opening will not propagate throughout cabin. The test program has three phases. A test schedule and status of required materials are presented.

Bricker, R. W.↗

Status of candidate materials for full-scale tests in the 737 fuselage

The test program has the objectives to: (1) increase passenger evacuation time to a minimum of five minutes from commercial aircraft in case of a fire; (2) prevent an external fire from entering closed cabins for five minutes by using fire barrier materials in the exterior wall; (3) demonstrate that a closed cabin will not reach 400 F; and (4) prove that a fire near a cabin opening will not propagate through the cabin for a minimum of five minutes. The materials status is outlined for seat cushions, upholstery and associated seat materials, wall and ceiling panels, floor panels, carpet and carpet underlay, windows, cargo bay liners, insulation bagging, and thermal acoustical insulation.

Supkis, D.↗

Low background focal plane array testing in the far infrared

A new long-wavelength infrared test facility is being developed to conduct proof-of-performance tests of focal plane arrays for the Infrared Astronomical Satellite (IRAS) telescope. This facility is believed to be unique in that it will calibrate full-sized arrays designed for the 5-120-micron region of the IR spectrum under simulated spaceflight conditions and at background levels as low as 8 million photons/sq cm-sec. Most of the tests will be performed in a main test chamber which contains a liquid helium shroud, blackbody sources, an arrangement to simulate zodiacal background, and spot scanning optics. A noncontaminating high-vacuum pumping system will be used to evacuate the chamber prior to cool-down to prevent molecular deposition. All housekeeping and focal plane signal outputs are multiplexed, digitized, and transmitted on high-speed data lines to a PDP-11/70 computer. The computer provides real-time displays on a color CRT terminal and stores data for subsequent reduction and hard copy output. An overview of the conceptual design and performance specifications of the test facility are given.

Iufer, E. J.↗

Shock tube spectroscopy of C3 + C2H mixture in the 140 to 700 nm range

Absorption spectroscopy has been performed in the reflected-shock region of a shock tube. Acetylene was shock-heated to produce a mixture, at around 4000 K, rich in C3 and C2H to simulate the ablation layer over the Jovian entry probe, and the spectral range from 140 to 700 nm was surveyed with an evacuable spectrograph. The observed spectra were dominated by those of C2 and C3 and an unknown band at wavelengths below 300 nm. The cross sections of the C3 Swings band in the 300 to 450 nm range agreed with previous measurements within a factor of 1.5. No absorption was observed in the wavelength range from 550 to 700 nm. The unknown broadband absorption with a peak cross section of 4 times 10 to the minus 17/sq cm at around 170 nm was attributed tentatively to the C2H radical. A preliminary calculation showed that the newly found absorption band would reduce the radiative heat flux to the stagnation point wall by about 12.5% in a typical flight condition.

Prakash, S. G.↗

Containerless materials processing in the laboratory

Drop tube makes possible preparation of exotic materials. The 100 foot tube is oriented precisely vertical to prevent free-falling drop from hitting tube walls. Inert-gas supply, evacuation pumps, viewing ports, and flexibility in choice of melt technique allow precise control and monitoring of solidification.

Lacy, L. L.↗

Time-sharing switch for vacuum brazing

Switching unit changes power and cooling-water connections between two vacuum-brazing machines. It allows both units to be powered by single radio-frequency (RF) generator. One machine can be used for brazing while bell jar of other is being evacuated (20 minute process) in preparation for brazing or is being cooled after brazing (10 minute process).

Stein, J. A.↗

Lightweight cryogenic vessel

Thin cooling jacket of recirculating liquid nitrogen is contained by relatively thin walls. Nitrogen is maintained at slight positive pressure, unlike full atmospheric pressure of conventional Dewar design, eliminating need for evacuated insulating spaces and heavy-walled shells. Besides cryogenic applications, design keeps liquids hot when recirculating liquid hotter than nitrogen is used.

Lewis, J. C.↗

Method of purifying metallurgical grade silicon employing reduced pressure atmospheric control

A method in which a quartz tube is charged with chunks of metallurgical grade silicon and/or a mixture of such chunks and high purity quartz sand, and impurities from a class including aluminum, boron, as well as certain transition metals including nickel, iron, and manganese is described. The tube is then evacuated and heated to a temperature within a range of 800 C to 1400 C. A stream of gas comprising a reactant, such as silicon tetrafluoride, is continuously delivered at low pressures through the charge for causing a metathetical reaction of impurities of the silicon and the reactant to occur for forming a volatile halide and leaving a residue of silicon of an improved purity. The reactant which included carbon monoxide gas and impurities such as iron and nickel react to form volatile carbonyls.

Ingle, W. M.↗

Solar heating and cooling demonstration project at the Florida solar energy center

The retrofitted solar heating and cooling system installed at the Florida Solar Energy Center is described. The system was designed to supply approximately 70 percent of the annual cooling and 100 percent of the heating load. The project provides unique high temperature, nonimaging, nontracking, evacuated tube collectors. The design of the system was kept simple and employs five hydronic loops. They are energy collection, chilled water production, space cooling, space heating and energy rejection. Information is provided on the system's acceptance test results operation, controls, hardware and installation, including detailed drawings.

Source record↗

Isothermal-desorption-rate measurements in the vicinity of the Curie temperature for H2 chemisorbed on nickel films

Measurements of the isothermal desorption rate of H2 chemisorbed onto polycrystalline nickel films made for temperatures spanning the Curie temperature of the nickel film are presented. Desorption kinetics were followed by measuring the decay of the change in resistance of the nickel film brought about by hydrogen chemisorption after gas-phase H2 had been rapidly evacuated. The desorption rate is found to undergo an anomalous decrease in the vicinity of the Curie temperature, accompanied by an increase in the desorption activation energy and the equilibrium constant for the chemisorbed hydrogen. The results are interpreted in terms of anomalous variations in rate constants for the formation of the precursor molecular adsorbed state and the chemisorbed atomic state due to the phase transition in the nickel. The changes in rate constants are also considered to be in qualitative agreement with theoretical predictions based on a spin coupling between the adatom and the magnetic substrate.

Shanabarger, M. R.↗

Storage, transmission and distribution of hydrogen

Current practices and future requirements for the storage, transmission and distribution of hydrogen are reviewed in order to identify inadequacies to be corrected before hydrogen can achieve its full potential as a substitute for fossil fuels. Consideration is given to the storage of hydrogen in underground solution-mined salt caverns, portable high-pressure containers and dewars, pressure vessels and aquifers and as metal hydrides, hydrogen transmission in evacuated double-walled insulated containers and by pipeline, and distribution by truck and internal distribution networks. Areas for the improvement of these techniques are indicated, and these technological deficiencies, including materials development, low-cost storage and transmission methods, low-cost, long-life metal hydrides and novel methods for hydrogen storage, are presented as challenges for research and development.

Kelley, J. H.↗

Solar-Cooled Classroom Building--Columbus, Ohio

Advanced, evacuated tubular collectors supply energy for heating and cooling of a university building. Report includes site files, specification references, drawings, and installation, operation and maintenance instructions.

Source record↗

Solar Heating for a Bottling Plant -- Jackson, Tennessee

Report describes retrofit solar-heating system designed for and installed in bottle works in Tennessee. System consists of 9,480 square feet (880 Square meters) of evacuated-tube solar collectors with attached specular cylindrical reflectors. Tubular collectors are expected to supply 55 percent of total thermal load.

Source record↗

Solar heating and cooling system installed at Columbus, Ohio

The Solar Energy System was installed as a part of a new construction of a college building. The building will house classrooms and laboratories, administrative offices and three lecture halls. The Solar Energy System consists of 4,096 square feet (128 panels) Owens/Illinois Evacuated Glass Tube Collector Subsystem, and a 5,000 gallon steel tank below ground storage system. Hot water is circulated between the collectors and storage tank, passing through a water/lithium bromide absorption chiller to cool the building.

Source record↗