Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVALUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Status of the International Criticality Safety Benchmark Evaluation Project

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) has continued its work generating evaluations of new and historical benchmark experiments since the last update to the nuclear criticality safety (NCS) community at the 12th International Conference on Nuclear Criticality Conference held in 2023. One additional version of the ICSBEP Handbook has been published since that update, and the Technical Review Group (TRG) held two in-person meetings to review and approve additional benchmarks. The 2022 and 2023 editions of the handbook were combined into one release (published in November 2024) and contained 13 new evaluations with 46 different configurations and two major revisions to existing evaluations. The 2024 version of the handbook, currently under publication review, will contain two new evaluations with 15 new configurations and one major revision to HEU-MET-FAST-028, the evaluation of Flattop with a uranium core. The ICSBEP TRG met again in person in April 2025 to review benchmarks for the 2025 ICSBEP Handbook and final comment resolution is currently ongoing. Many of the new benchmarks represent contemporaneous experiments that have been specifically optimized to provide validation cases relevant to the NCS community. One major area of focus for new critical experiments is to target the sparsely populated intermediate energy (or resonance) region. Another focus of many of the new benchmarks is to provide experiments sensitive to different materials, such as chlorine, hafnium, tantalum, titanium, molybdenum, chromium, and polymethyl methacrylate (PMMA, or Lucite). The ICSBEP continues to deliver high-quality, peer reviewed evaluations of integral experiments relevant to the nuclear data community.

HEU-MET-FAST-028↗

Covariances Obtained from an Evaluation of the Neutron Cross Section Standards

New measurements and an improved evaluation process were used to obtain a new evaluation of the neutron cross section standards. Efforts were made to include as much information as possible on the components of the data uncertainties that were then used to obtain the covariance matrices for the experimental data. Evaluations were produced from this process for the {sup 6}Li(n,t), {sup 10}B(n,{alpha}), {sup 10}B(n,{alpha}{sub 1}{gamma}), {sup 197}Au(n,{gamma}), {sup 235}U(n,f), and {sup 238}U(n,f) standard cross sections as well as the non-standard {sup 6}Li(n,n), {sup 10}B(n,n), {sup 238}U(n,{gamma}) and {sup 239}Pu(n,f) cross sections. There is a general increase in the cross sections for most of the new evaluations, by as much as about 5%, compared with the ENDF/B-VI results. Covariance data were obtained for the {sup 6}Li(n,t), {sup 6}Li(n,n), {sup 10}B(n,{alpha}), {sup 10}B(n,{alpha}{sub 1}{gamma}), {sup 10}B(n,n), {sup 197}Au(n,{gamma}), {sup 235}U(n,f), {sup 238}U(n,f), {sup 238}U(n,{gamma}) and {sup 239}Pu(n,f) reactions. Also an independent R-Matrix evaluation was produced for the H(n,n) standard cross-section, however, covariance data are not available for this reaction. The evaluations were used in the new ENDF/B-VII library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed tool applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An integrated approach for water scarcity evaluation—a case study of Yunnan, China

In this paper, an integrated approach based on multiple indicators and individual and combinational evaluation methods is proposed to evaluate water scarcity. Four evaluation methods are employed, and their results are joined through three combination methods in order to obtain a consistent evaluation. This iterative-correction approach has been applied to Yunnan Province in China for water scarcity evaluation. The results demonstrate the capability of the iterative-correction framework to provide insightful analyses of water scarcity. Diqing Tibetan Autonomous Prefecture (Diqing) and Nujiang Li Autonomous Prefecture (Nujiang) ranked 1st and 2nd, indicating the best situation for water scarcity evaluation, while Yuxi and Zhaotong ranked 15th and 16th, indicating the worst situation. Two types of major water scarcities were observed in Yunnan Province. One was a typical representative of lack of water quality in the central part of Yunnan, and the other was a typical engineering type in the western part of Yunnan. The water scarcity has been found to arise from non-judicious water use, rapid urbanization and lack of protective measures for water resources. Finally and therefore, it is necessary to conduct more water conservancy projects in future to alleviate the water scarcity issue.

54 ENVIRONMENTAL SCIENCES↗

A simple, rapid, and sensitive system for the evaluation of anti-viral drugs in rats

Highlights: Black-Right-Pointing-Pointer We established a novel, simple and rapid in vivo system for evaluation of anti-HIV-1 drugs with rats. Black-Right-Pointing-Pointer The system may be applicable for other antiviral drugs, and/or useful for initial screening in vivo. Black-Right-Pointing-Pointer In this system, TRI-1144 displayed the most potent anti-HIV-1 activity in vivo. -- Abstract: The lack of small animal models for the evaluation of anti-human immunodeficiency virus type 1 (HIV-1) agents hampers drug development. Here, we describe the establishment of a simple and rapid evaluation system in a rat model without animal infection facilities. After intraperitoneal administration of test drugs to rats, antiviral activity in the sera was examined by the MAGI assay. Recently developed inhibitors for HIV-1 entry, two CXCR4 antagonists, TF14016 and FC131, and four fusion inhibitors, T-20, T-20EK, SC29EK, and TRI-1144, were evaluated using HIV-1{sub IIIB} and HIV-1{sub BaL} as representative CXCR4- and CCR5-tropic HIV-1 strains, respectively. CXCR4 antagonists were shown to only possess anti-HIV-1{sub IIIB} activity, whereas fusion inhibitors showed both anti-HIV-1{sub IIIB} and anti-HIV-1{sub BaL} activities in rat sera. These results indicate that test drugs were successfully processed into the rat sera and could be detected by the MAGI assay. In this system, TRI-1144 showed the most potent and sustained antiviral activity. Sera from animals not administered drugs showed substantial anti-HIV-1 activity, indicating that relatively high dose or activity of the test drugs might be needed. In conclusion, the novel rat system established here, 'phenotypic drug evaluation', may be applicable for the evaluation of various antiviral drugs in vivo.

60 APPLIED LIFE SCIENCES↗

Evaluating the substantive effectiveness of SEA: Towards a better understanding

Evaluating the substantive effectiveness of strategic environmental assessment (SEA) is vital in order to know to what extent the tool fulfills its purposes and produces expected results. However, the studies that have evaluated the substantive effectiveness of SEA produce varying outcomes as regards the tool's contribution to decision-making and have used a variety of approaches to appraise its effectiveness. The aim of this article is to discuss the theoretical concept of SEA substantive effectiveness and to present a new approach that can be applied for evaluation studies. The SEA effectiveness evaluation framework that will be presented is composed of concepts of, and approaches to, SEA effectiveness derived from SEA literature and planning theory. Lessons for evaluation can be learned from planning theory in particular, given its long history of analyzing and understanding how sources of information and decisions affect (subsequent) decision-making. Key concepts of this new approach are 'conformance' and 'performance'. In addition, this article presents a systematic overview of process and context factors that can explain SEA effectiveness, derived from SEA literature. To illustrate the practical value of our framework for the assessment and understanding of substantive effectiveness of SEA, three Dutch SEA case studies are examined. The case studies have confirmed the usefulness of the SEA effectiveness assessment framework. The framework proved helpful in order to describe the cumulative influence of the three SEAs on decision-making and the ultimate plan. - Highlights: Black-Right-Pointing-Pointer A new framework to evaluate the substantive effectiveness of SEA is presented. Black-Right-Pointing-Pointer The framework is based on two key concepts: 'conformance' and 'performance.' Black-Right-Pointing-Pointer The practical applicability of the framework is demonstrated by three Dutch cases. Black-Right-Pointing-Pointer The framework allows for a more systematic understanding of SEA effectiveness. Black-Right-Pointing-Pointer Finally, this paper presents explanations for SEA effectiveness.

54 ENVIRONMENTAL SCIENCES↗

Effect of odour on multisensory environmental evaluations of road traffic

This study investigated the effect of odour on multisensory environmental evaluations of road traffic. The study aimed to answer: (1) Does odour have any effect on evaluations on noise, landscape and the overall environment? (2) How different are participants' responses to odour stimuli and are these differences influential on the evaluations? Experimental scenarios varied in three Traffic levels, three Tree screening conditions and two Odour presence conditions were designed, and presented to participants in virtual reality. Perceived Loudness, Noise Annoyance, Landscape Quality and Overall Pleasantness of each scenario were evaluated and the results were analysed. It shows that Odour presence did not have significant main effect on any of the evaluations, but has significant interactions with Traffic level on Noise Annoyance and with Tree screening on Landscape Quality, indicating the potential of odour to modulate noise and visual landscape perceptions in specific environmental content. Concerning participants' responses to odour stimuli, large differences were found in this study. However, the differences did not seem to be influential on environmental evaluations in this study. Larger samples of participants may benefit this study for more significant results of odour effect.

54 ENVIRONMENTAL SCIENCES↗

Progressing quality control in environmental impact assessment beyond legislative compliance: An evaluation of the IEMA EIA Quality Mark certification scheme

The effectiveness of Environmental Impact Assessment (EIA) systems is contingent on a number of control mechanisms: procedural; judicial; evaluative; public and government agency; professional; and development aid agency. If we assume that procedural and judicial controls are guaranteed in developed EIA systems, then progressing effectiveness towards an acceptable level depends on improving the performance of other control mechanisms over time. These other control mechanisms are either absent, or are typically centrally controlled, requiring public finances; this we argue is an unpopular model in times of greater Government austerity. Here we evaluate a market-based mechanism for improving the performance of evaluative and professional control mechanisms, the UK Institute of Environmental Management and Assessments' EIA Quality Mark. We do this by defining dimensions of effectiveness for the purposes of our evaluation, and by identifying international examples of the approaches taken to delivering the other control measures to validate the approach taken in the EIA Quality Mark. We then evaluate the EIA Quality Mark, when used in combination with legal procedures and an active judiciary, against the effectiveness dimensions and use time-series analysis of registrant data to examine its ability to progress practice. We conclude that the EIA Quality Mark has merit as a model for a market-based mechanism, and may prove a more financially palatable approach for delivering effective EIA in mature systems in countries that lack centralised agency oversight. It may, therefore, be of particular interest to some Member States of the European Union for ensuring forthcoming certification requirements stemming from recent amendments to the EIA Directive. - Highlights: • Quality control mechanisms in EIA are identified. • Effectiveness of EIA is conceptualised for evaluation purposes. • The UK IEMA EIA Quality Mark is introduced as a market-based mechanism. • The EIA Quality Mark is found to progress quality in many, but not all, areas.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Investigation of the Performance of the Unified Monte Carlo Method of Neutron Cross Section Data Evaluation

The Unified Monte Carlo method (UMC) has been suggested to avoid certain limitations and approximations inherent to the well-known Generalized Least Squares (GLS) method of nuclear data evaluation. This contribution reports on an investigation of the performance of the UMC method in comparison with the GLS method. This is accomplished by applying both methods to simple examples with few input values that were selected to explore various features of the evaluation process that impact upon the quality of an evaluation. Among the issues explored are: i) convergence of UMC results with the number of Monte Carlo histories and the ranges of sampled values; ii) a comparison of Monte Carlo sampling using the Metropolis scheme and a brute force approach; iii) the effects of large data discrepancies; iv) the effects of large data uncertainties; v) the effects of strong or weak model or experimental data correlations; and vi) the impact of ratio data and integral data. Comparisons are also made of the evaluated results for these examples when the input values are first transformed to comparable logarithmic values prior to performing the evaluation. Some general conclusions that are applicable to more realistic evaluation exercises are offered.

99 GENERAL AND MISCELLANEOUS↗

Seismic evaluation of vulnerability for SAMA educational buildings in Tehran

Earthquake is a destructive phenomenon that trembles different parts of the earth yearly and causes many destructions. Iran is one of the (high seismicity) quack- prone parts of the world that has received a lot of pecuniary damages and life losses each year, schools are of the most important places to be protected during such crisis.There was no special surveillance on designing and building of school's building in Tehran till the late 70's, and as Tehran is on faults, instability of such buildings may cause irrecoverable pecuniary damages and especially life losses, therefore preventing this phenomenon is in an urgent need.For this purpose, some of the schools built during 67-78 mostly with Steel braced frame structures have been selected, first, by evaluating the selected Samples, gathering information and Visual Survey, the prepared questionnaires were filled out. With the use of ARIA and SABA (Venezuela) Methods, new modified combined method for qualified evaluations was found and used.Then, for quantified evaluation, with the use of computer 3D models and nonlinear statically analysis methods, a number of selected buildings of qualified evaluation, were reevaluated and finally with nonlinear dynamic analysis method the real behavior of structures on the earthquakes is studied.The results of qualified and quantified evaluations were compared and a proper Pattern for seismic evaluation of Educational buildings was presented. Otherwise the results can be a guidance for the person in charge of retrofitting or if necessary rebuilding the schools.

58 GEOSCIENCES↗

Resolved Resonance Evaluation for Neutron Interactions with 103 Rh up to 8 keV

A neutron cross-section evaluation for the n + 103 Rh reaction in the resolved resonance region was carried out in the energy range 10−5 eV to 8 keV encompassing thermal energy at 0.0253 eV. The scope of this work is to generate resonance parameters and resonance parameter covariances based on the Reich-Moore reduced R-matrix formalism using the code SAMMY. Some features of the new evaluation are the inclusion of high-resolution capture data in the SAMMY evaluation process and the extension of the resolved resonance range from 4 to 8 keV. Furthermore, the evaluation employs more accurate resonance parameter representation by exploring the use of the LRF = 7 ENDF feature and also the use of the LCOMP = 2 compact format for resonance parameter covariance representation. Included in the SAMMY evaluation are transmission data, capture cross-section data, and neutron scattering length information. Thermal cross-section values listed in the literature, as well as capture resonance integrals, were also incorporated into the evaluation process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

How to select distracted driving countermeasures evaluation metrics: A systematic review

While there are numerous performance metrics that have been developed for the evaluation of distracted driving prevention programs, there is little information on how to select them depending on the requirements and/or objectives of the study. Here, this paper describes a systematic literature review that was conducted on the metrics for evaluating distracted driving countermeasures in order to bridge this research gap. A summary of the evaluation metrics used for the existing distracted driving countermeasures was provided. Guidance for choosing an evaluation measure was provided by analyzing the metrics from the perspectives of functionality, spatial-temporal dimension, and equity. Three examples of distracted driving countermeasure evaluation processes were thoroughly reviewed in order to offer insight into metric selection and measurement. This paper contributes to the body of knowledge by discussing the implications for policy on how to enhance the thoroughness and accuracy of the evaluation of distracted driving countermeasures. Analysis from multiple angles, the development of data collection tools and direct behavior indicators, taking into account temporal dimensions, and equity considerations, are proposed.

99 GENERAL AND MISCELLANEOUS↗

Development of evaluation models of manpower needs for dismantling the dry conversion process-related equipment in uranium refining and conversion plant (URCP)

Evaluation models for determining the manpower needs for dismantling various types of equipment in uranium refining and conversion plant (URCP) have been developed. The models are widely applicable to other uranium handling facilities. Additionally, a simplified model was developed for easily and accurately calculating the manpower needs for dismantling dry conversion process-related equipment (DP equipment). It is important to evaluate beforehand project management data such as manpower needs to prepare an optimized decommissioning plan and implement effective dismantling activity. The Japan Atomic Energy Agency (JAEA) has developed the project management data evaluation system for dismantling activities (PRODIA code), which can generate project management data using evaluation models. For preparing an optimized decommissioning plan, these evaluation models should be established based on the type of nuclear facility and actual dismantling data. In URCP, the dry conversion process of reprocessed uranium and others was operated until 1999, and the equipment related to the main process was dismantled from 2008 to 2011. Actual data such as manpower for dismantling were collected during the dismantling activities, and evaluation models were developed using the collected actual data on the basis of equipment classification considering the characteristics of uranium handling facility. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy

Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, the similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of the gamma evaluation method in Gamma Knife film dosimetry

Purpose: Gamma Knife (GK) radiosurgery is a minimally invasive surgical technique for the treatment of intracranial lesions. To minimize neurological deficits, submillimeter accuracy is required during treatment delivery. In this paper, the delivery accuracy of GK radiosurgery was assessed with the gamma evaluation method using planning dose distribution and film measurement data. Methods: Single 4, 8, and 16 mm and composite shot plans were developed for evaluation using the GK Perfexion (PFX) treatment planning system (TPS). The planning dose distributions were exported as digital image communications in medicine - radiation therapy (DICOM RT) files using a new function of GK TPS. A maximum dose of 8 Gy was prescribed for four test plans. Irradiation was performed onto a spherical solid water phantom using Gafchromic EBT2 films in the axial and coronal planes. The exposed films were converted to absolute dose based on a 4th-order polynomial calibration curve determined using ten calibration films. The film measurement results and planning dose distributions were registered for further analysis in the same Leksell coordinate using in-house software. The gamma evaluation method was applied to two dose distributions with varying spatial tolerance (0.3-2.0 mm) and dosimetric tolerance (0.3-2.0%), to verify the accuracy of GK radiosurgery. The result of gamma evaluation was assessed using pass rate, dose gamma index histogram (DGH), and dose pass rate histogram (DPH). Results: The 20, 50, and 80% isodose lines found in film measurements were in close agreement with the planning isodose lines, for all dose levels. The comparison of diagonal line profiles across the axial plane yielded similar results. The gamma evaluation method resulted in high pass rates of >95% within the 50% isodose line for 0.5 mm/0.5% tolerance criteria, in both the axial and coronal planes. They satisfied 1.0 mm/1.0% criteria within the 20% isodose line. Our DGH and DPH also showed that low isodose lines exhibited inferior gamma indexes and pass rates compared with higher isodose lines. Conclusions: The gamma evaluation method was applicable to GK radiosurgery. For all test plans, planning dose distribution and film measurement met the tolerance criteria of 0.5 mm/0.5% within the 50% isodose line which are used for marginal dose prescription.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of potential internal target volume of liver tumors using cine-MRI

Purpose: Four-dimensional computed tomography (4DCT) is widely used for evaluating moving tumors, including lung and liver cancers. For patients with unstable respiration, however, the 4DCT may not visualize tumor motion properly. High-speed magnetic resonance imaging (MRI) sequences (cine-MRI) permit direct visualization of respiratory motion of liver tumors without considering radiation dose exposure to patients. Here, the authors demonstrated a technique for evaluating internal target volume (ITV) with consideration of respiratory variation using cine-MRI. Methods: The authors retrospectively evaluated six patients who received stereotactic body radiotherapy (SBRT) to hepatocellular carcinoma. Before acquiring planning CT, sagittal and coronal cine-MRI images were acquired for 30 s with a frame rate of 2 frames/s. The patient immobilization was conducted under the same condition as SBRT. Planning CT images were then acquired within 15 min from cine-MRI image acquisitions, followed by a 4DCT scan. To calculate tumor motion, the motion vectors between two continuous frames of cine-MRI images were calculated for each frame using the pyramidal Lucas–Kanade method. The target contour was delineated on one frame, and each vertex of the contour was shifted and copied onto the following frame using neighboring motion vectors. 3D trajectory data were generated with the centroid of the contours on sagittal and coronal images. To evaluate the accuracy of the tracking method, the motion of clearly visible blood vessel was analyzed with the motion tracking and manual detection techniques. The target volume delineated on the 50% (end-exhale) phase of 4DCT was translated with the trajectory data, and the distribution of the occupancy probability of target volume was calculated as potential ITV (ITV {sub Potential}). The concordance between ITV {sub Potential} and ITV estimated with 4DCT (ITV {sub 4DCT}) was evaluated using the Dice’s similarity coefficient (DSC). Results: The distance between blood vessel positions determined with motion tracking and manual detection was analyzed. The mean and SD of the distance were less than 0.80 and 0.52 mm, respectively. The maximum ranges of tumor motion on cine-MRI were 2.4 ± 1.4 mm (range, 1.0–5.0 mm), 4.4 ± 3.3 mm (range, 0.8–9.4 mm), and 14.7 ± 5.9 mm (range, 7.4–23.4 mm) in lateral, anterior–posterior, and superior–inferior directions, respectively. The ranges in the superior–inferior direction were larger than those estimated with 4DCT images for all patients. The volume of ITV {sub Potential} was 160.3% ± 13.5% (range, 142.0%–179.2%) of the ITV {sub 4DCT}. The maximum DSC values were observed when the cutoff value of 24.7% ± 4.0% (range, 20%–29%) was applied. Conclusions: The authors demonstrated a novel method of calculating 3D motion and ITV {sub Potential} of liver cancer using orthogonal cine-MRI. Their method achieved accurate calculation of the respiratory motion of moving structures. Individual evaluation of the ITV {sub Potential} will aid in improving respiration management and treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-F-J-85: Evaluation of the Velocity Deformable Image Registration Algorithm

Purpose: To perform validation and commissioning of a commercial deformable image registration (DIR) algorithm (Velocity, Varian Medical Systems) for numerous clinical sites using single and multi-modality images. Methods: In this retrospective study, the DIR algorithm was evaluated for 10 patients in each of the following body sites: head and neck (HN), prostate, liver, and gynecological (GYN). HN DIRs were evaluated from planning (p)CT to re-pCT and pCTs to daily CBCTs using dice similarity coefficients (DSC) of corresponding anatomical structures. Prostate DIRs were evaluated from pCT to CBCTs using DSC and target registration error (TRE) of implanted RF beacons within the prostate. Liver DIRs were evaluated from pMR to pCT using DSC and TRE of vessel bifurcations. GYN DIRs were evaluated between fractionated brachytherapy MRIs using DSC of corresponding anatomical structures. Results: Analysis to date has given average DSCs for HN pCT-to-(re)pCT DIR for the brainstem, cochleas, constrictors, spinal canal, cord, esophagus, larynx, parotids, and submandibular glands as 0.88, 0.65, 0.67, 0.91, 0.77, 0.69, 0.77, 0.87, and 0.71, respectively. Average DSCs for HN pCT-to-CBCT DIR for the constrictors, spinal canal, esophagus, larynx, parotids, and submandibular glands were 0.64, 0.90, 0.62, 0.82, 0.75, and 0.69, respectively. For prostate pCT-to-CBCT DIR the DSC for the bladder, femoral heads, prostate, and rectum were 0.71, 0.82, 0.69, and 0.61, respectively. Average TRE using implanted beacons was 3.35 mm. For liver pCT-to-pMR, the average liver DSC was 0.94 and TRE was 5.26 mm. For GYN MR-to-MR DIR the DSC for the bladder, sigmoid colon, GTV, and rectum were 0.79, 0.58, 0.67, and 0.76, respectively. Conclusion: The Velocity DIR algorithm has been evaluated over a number of anatomical sites. This work functions to document the uncertainties in the DIR in the commissioning process so that these can be accounted for in the development of downstream clinical processes. This work was supported in part by a co-development agreement with Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗