Conference on Applications of Digital Image Processing to Astronomy, Pasadena, Calif., August 20-22, 1980, Proceedings

The astronomic applications of non-military digital image processing are covered in this conference volume. Systems like CCD's, interactive data analysis facilities, stellar speckle interferometry, sky flux subsystems, guide star systems and various image processing systems are described. Techniques in photometry including filtering, automatic photometry, and image restoration are examined. Digital spectral analyses of galaxies, supernova remnants, stars and other celestial bodies are discussed together with algorithms developed to calibrate, clean up, enhance, and quantitatively analyze data. The techniques of image processing permit astronomers to make much more efficient use of their data for both subjective and quantitative analyses. Future missions, such as the Space Telescope, representing a vast data base are briefly covered.

Elliott, D. A.↗

A theoretical analysis of the round-off propagation in different Kalman filter implementations

A theoretical analysis is made of the error propagation due to numerical round-off for four different Kalman filter implementations: the conventional Kalman filter, the square root covariance filter, the square root information filter and the Chandrasekhar square root filter. From these error models, new insights about the applicability of the different filters and their sensitivity to round-off, is obtained. It is shown that the CKF may become completely unreliable when the original plant is unstable, and that this is easily circumvented by a number of techniques. The square root filters, often quoted to possess a conditioning or sensitivity that is the square root of that of the CKF, are shown to possess this property only for the computation of the covariance of the filtered signal and not for the computation of the Kalman gain or the filtered estimate. Finally, the Chandrasekhar filter is shown to be numerically unstable.

Verhaegen, M.↗

Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor

Detection and measurement of radiation is used extensively for non-invasive material characterization in a range of industries. However, many practical applications are frustrated by pulse pile-up within the detector. Pulse pile-up, which occurs when multiple radiation events arrive within the temporal resolving time of the detector, degrades the fidelity of subsequent material analysis. Traditional pulse processing techniques use fast digital filters and logic circuits to detect piled-up events and discard the corrupted data, however, this leads to substantial detector dead time. Consequently, there is considerable interest in more complex signal-processing algorithms to extend the performance of pulse processors and improve material characterization techniques. We present a technology for real-time decoding of pulse pile-up events. It is a model-based signal-processing algorithm able to accurately characterize the number, time-of-arrival and energy of all events in the detector output. Even in the presence of severe multi-pulse pile-up, the composite events are decoded and the energy and time-of-arrival recovered. The technology has been evaluated using a range of detectors, sources and count rates. An exceptional improvement over traditional pulse processing techniques is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Software Reduces Radio-Interference Effects in Radar Data

A computer program suppresses the effects of narrow-band radio-frequency interference (RFI) on the data collected by a wide-band radar system. The need for this program arises because some advanced wide-band synthetic-aperture radar systems utilize frequency bands that include frequencies used by other radio services. In this program, the RFI environment is represented by an auto-regressive process, the frequency band of which is narrow relative to that of the radar. Most of the RFI signals, both narrow- and wide-band, are estimated in one pass of a least-mean-square (LMS) adaptive filter. The program implements three popular LMS algorithms: the time-domain LMS, the frequency-domain LMS, and the filter-bank LMS adaptive-filter algorithms. The program can be run in a manual or automatic mode. In the manual mode, the user selects the filter parameters prior to execution. In the automatic mode, the program utilizes median-filter and spectral-estimation techniques plus the variable-step-size LMS algorithm for automatic determination of filter parameters, and the parameters are adaptively changed as functions of the inputs, resulting in better overall performance.

Le, Charles T-C↗

Combining Particle Filters and Consistency-Based Approaches for Monitoring and Diagnosis of Stochastic Hybrid Systems

Fault detection and isolation are critical tasks to ensure correct operation of systems. When we consider stochastic hybrid systems, diagnosis algorithms need to track both the discrete mode and the continuous state of the system in the presence of noise. Deterministic techniques like Livingstone cannot deal with the stochasticity in the system and models. Conversely Bayesian belief update techniques such as particle filters may require many computational resources to get a good approximation of the true belief state. In this paper we propose a fault detection and isolation architecture for stochastic hybrid systems that combines look-ahead Rao-Blackwellized Particle Filters (RBPF) with the Livingstone 3 (L3) diagnosis engine. In this approach RBPF is used to track the nominal behavior, a novel n-step prediction scheme is used for fault detection and L3 is used to generate a set of candidates that are consistent with the discrepant observations which then continue to be tracked by the RBPF scheme.

Narasimhan, Sriram↗

Evaluation of digitally corrected ERTS imagery

Utilizing all digital processing techniques, precision rectified ERTS multispectral imagery have been produced. Precision geometric correction is accomplished by: (1) utilizing a low order piecewise approximation to the image distortions; (2) incorporating spacecraft attitude refinement derived from ground control points utilized in a Kalman filter; (3) utilizing interpolation techniques which preserve value and slope continuity in the image data. Imagery produced is represented in a UTM projection, and has been evaluated for precision by statistical and analytical methods. Extrapolations to modest size computers indicate good throughput with no sacrifice in precision.

Rifman, S. S.↗

Project: Micromachined High-Frequency Circuits For Sub-mm-wave Sensors

A novel micromachined resonator at 45 GHz based on a defect in a periodic electromagnetic bandgap structure (EBG) and a two-pole Tchebysbev filter with 1.4% 0.15 dB equiripple bandwidth and 2.3 dB loss employing this resonator are presented in this letter. The periodic bandgap structure is realized on a 400 micron thick high-resistivity silicon wafer using deep reactive ion etching techniques. The resonator and filter can be accessed via coplanar waveguide feeds.

Papapolymerou, Ioannis John↗

High-Speed Imaging Optical Pyrometry for Study of Boron Nitride Nanotube Generation

A high-speed imaging optical pyrometry system is designed for making in-situ measurements of boron temperature during the boron nitride nanotube synthesis process. Spectrometer measurements show molten boron emission to be essentially graybody in nature, lacking spectral emission fine structure over the visible range of the electromagnetic spectrum. Camera calibration experiments are performed and compared with theoretical calculations to quantitatively establish the relationship between observed signal intensity and temperature. The one-color pyrometry technique described herein involves measuring temperature based upon the absolute signal intensity observed through a narrowband spectral filter, while the two-color technique uses the ratio of the signals through two spectrally separated filters. The present study calibrated both the one- and two-color techniques at temperatures between 1,173 K and 1,591 K using a pco.dimax HD CMOS-based camera along with three such filters having transmission peaks near 550 nm, 632.8 nm, and 800 nm.

Inman, Jennifer A.↗

Reconstruction of the shuttle reentry air data parameters using a linearized Kalman filter

This paper presents the reconstruction of the space shuttle's wind-relative reentry trajectory for the orbital flights. The technique uses a linearized Kalman filter (LKF) to merge highand low-frequency inertial and wind-relative data to obtain enhanced high-frequency results that closely follow expected mean levels. Two verifications are presented. First, wind trajectories resulting from the reconstruction are compared with analytically predicted values. There is close comparison. Second, the frequency characteristics are investigated using system identification techniques. The stability and control model generated using the LKF trajectory shows good agreement between measured and predicted spacecraft response for both high and low frequencies.

Whitmore, S. A.↗

VUV thin films, chapter 7

The application of thin film technology to the vacuum ultraviolet (VUV) wavelength region from 120 nm to 230 nm has not been fully exploited in the past because of absorption effects which complicate the accurate determination of the optical functions of dielectric materials. The problem therefore reduces to that of determining the real and imaginary parts of a complex optical function, namely the frequency dependent refractive index n and extinction coefficient k. We discuss techniques for the inverse retrieval of n and k for dielectric materials at VUV wavelengths from measurements of their reflectance and transmittance. Suitable substrate and film materials are identified for application in the VUV. Such applications include coatings for the fabrication of narrow and broadband filters and beamsplitters. The availability of such devices open the VUV regime to high resolution photometry, interferometry and polarimetry both for space based and laboratory applications. This chapter deals with the optics of absorbing multilayers, the determination of the optical functions for several useful materials, and the design of VUV multilayer stacks as applied to the design of narrow and broadband reflection and transmission filters and beamsplitters. Experimental techniques are discussed briefly, and several examples of the optical functions derived for selected materials are presented.

Zukic, Muamer↗

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parallelized Kalman-Filter-Based Reconstruction of Particle Tracks on Many-Core Processors and GPUs

For over a decade now, physical and energy constraints have limited clock speed improvements in commodity microprocessors. Instead, chipmakers have been pushed into producing lower-power, multi-core processors such as Graphical Processing Units (GPU), ARM CPUs, and Intel MICs. Broad-based efforts from manufacturers and developers have been devoted to making these processors user-friendly enough to perform general computations. However, extracting performance from a larger number of cores, as well as specialized vector or SIMD units, requires special care in algorithm design and code optimization. One of the most computationally challenging problems in high-energy particle experiments is finding and fitting the charged-particle tracks during event reconstruction. This is expected to become by far the dominant problem at the High-Luminosity Large Hadron Collider (HL-LHC), for example. Today the most common track finding methods are those based on the Kalman filter. Experience with Kalman techniques on real tracking detector systems has shown that they are robust and provide high physics performance. This is why they are currently in use at the LHC, both in the trigger and offine. Previously we reported on the significant parallel speedups that resulted from our investigations to adapt Kalman filters to track fitting and track building on Intel Xeon and Xeon Phi. Here, we discuss our progresses toward the understanding of these processors and the new developments to port the Kalman filter to NVIDIA GPUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EFQPSK Versus CERN: A Comparative Study

This report presents a comparative study on Enhanced Feher's Quadrature Phase Shift Keying (EFQPSK) and Constrained Envelope Root Nyquist (CERN) techniques. These two techniques have been developed in recent times to provide high spectral and power efficiencies under nonlinear amplifier environment. The purpose of this study is to gain insights into these techniques and to help system planners and designers with an appropriate set of guidelines for using these techniques. The comparative study presented in this report relies on effective simulation models and procedures. Therefore, a significant part of this report is devoted to understanding the mathematical and simulation models of the techniques and their set-up procedures. In particular, mathematical models of EFQPSK and CERN, effects of the sampling rate in discrete time signal representation, and modeling of nonlinear amplifiers and predistorters have been considered in detail. The results of this study show that both EFQPSK and CERN signals provide spectrally efficient communications compared to filtered conventional linear modulation techniques when a nonlinear power amplifier is used. However, there are important differences. The spectral efficiency of CERN signals, with a small amount of input backoff, is significantly better than that of EFQPSK signals if the nonlinear amplifier is an ideal clipper. However, to achieve such spectral efficiencies with a practical nonlinear amplifier, CERN processing requires a predistorter which effectively translates the amplifier's characteristics close to those of an ideal clipper. Thus, the spectral performance of CERN signals strongly depends on the predistorter. EFQPSK signals, on the other hand, do not need such predistorters since their spectra are almost unaffected by the nonlinear amplifier, Ibis report discusses several receiver structures for EFQPSK signals. It is observed that optimal receiver structures can be realized for both coded and uncoded EFQPSK signals with not too much increase in computational complexity. When a nonlinear amplifier is used, the bit error rate (BER) performance of the CERN signals with a matched filter receiver is found to be more than one decibel (dB) worse compared to the bit error performance of EFQPSK signals. Although channel coding is found to provide BER performance improvement for both EFQPSK and CERN signals, the performance of EFQPSK signals remains better than that of CERN. Optimal receiver structures for CERN signals with nonlinear equalization is left as a possible future work. Based on the numerical results, it is concluded that, in nonlinear channels, CERN processing leads towards better bandwidth efficiency with a compromise in power efficiency. Hence for bandwidth efficient communications needs, CERN is a good solution provided effective adaptive predistorters can be realized. On the other hand, EFQPSK signals provide a good power efficient solution with a compromise in band width efficiency.

Borah, Deva K.↗

Characterization of Infrared Diode Laser Beams and Atmospheric CO Imaging Instrument

During June-August 1997 Dr. Jonathan Miles participated in the ASEE-sponsored summer faculty research program at NASA Langley Research Center (LaRC). The Aerospace Electronic Systems Division (AESD), Sensor Systems Branch (SSB), at NASA LARC had proposed a new mission, GEOstationary TROpospheric Pollution SATellite (GEO TROPSAT), to address critical science questions of tropospheric chemistry. The troposphere is a complex system, comprising "point" and distributed sources of natural and anthropogenic origin; complicated transport processes, both lateral and vertical; and photochemistry driven by UV flux, temperature, atmospheric composition, and other variables. GEO TROPSAT would be implemented about a geostationary Earth orbital (GEO) position at the equator between 600 and 80" West longitude to observe the Americas and large portions of the oceans of either coast. This mission would advance our knowledge of the atmosphere by capturing the wide temporal and spatial variability of tropospheric phenomena which is undetectable from low Earth orbit. A pre-prototype imaging carbon monoxide (CO) imaging system operating within a narrow waveband about 4.7 [Lm was built, demonstrated, and evaluated. This system applies the gas-filter correlation radiometry (GFCR) technique and produces digitized images comprising 4096 pixels, each representing a single CO mixing ratio measurement inferred from radiometric data. Associated tasks accomplished included specification for the next-generation prototype system to operate in the 2.3-@tm waveband; characterization of a 64x64, InSb focal-plane-array (FPA) imager; design, fabrication, and assembly of a filter wheel; and software development. Laboratory evaluation of this system involved imaging of a test cell placed in the path of radiant flux emanating from a blackbody source used to simulate the radiant energy reflected by Earth in real application. The cell was evacuated for system balancing and then charged with measured quantities of CO to provide a means for system characterization. Two related research efforts were undertaken during the term of the study reported here - continued development of an atmospheric CO imaging instrument and characterization of diode-laser beams. Both efforts were successful and are described within the body of this report. A second objective was to provide a means for undergraduate ISAT majors to become involved with the research described, to be afforded the opportunity to learn the technologies associated with the work performed. Two ISAT students gained a comprehensive understanding and interest in missions supported by NASA through direct involvement in this project. Many more students were exposed to these technologies through demonstrations, laboratory tours, and explanations provided in lectures.

Miles, Jonathan J.↗

SU-E-T-359: Emulation of Yb-169 Gamma-Ray Spectrum Using Metal-Filtered 250 KVp X-Rays for Pre-Clinical Studies of Gold Nanoparticle-Aided Radiation Therapy

Purpose: To develop an external beam surrogate of the Yb-169 brachytherapy source applying a filter-based spectrum modulation technique to 250 kVp x-rays. In-vitro/vivo studies performed with the modulated 250 kVp beam will help gauge the benefits of implementing gold nanoparticle-aided radiotherapy with the Yb-169 source. Methods: A previously validated MCNP5 model of the Phillips RT-250 orthovoltage unit was used to obtain the percentage depth dose (PDD) and filtered photon spectra for a variety of filtration and irradiation conditions. Photon spectra were obtained using the average flux F4 tally in air right after all collimation. A 30 x 30 x 30 cm{sup 3} water phantom was used to compute the PDD along the central axis (CAX) under the standards conditions of a 10 x 10 cm{sup 2} field size at 50 cm SSD. Cylindrical cells of 4 cm in diameter and the energy deposition F6 tally were used along the CAX to score the doses down to 20 cm depth. The number of particle history was set to 2 x 10{sup 8} in order to keep the relative uncertainty within each cell < 0.3%. The secondary electron spectrum within a gold-loaded tissue due to each photon spectrum was also calculated using EGSnrc and compared with that due to Yb-169 gamma rays. Results: Under the practical constraints for the spectrum modulation task, 250 kVp x-rays filtered by a 0.25 mm Erbium (Er) foil produced the best match with Yb-169 gamma rays, in terms of PDD and, more importantly, secondary electron spectrum. Conclusion: Modulation of 250kVp x-ray spectrum by an Er-filter was found effective in emulating the gamma ray spectrum of Yb-169. Possible benefits as predicted from the current MC model such as enhanced radiosensitization with the Er-filtered beam (as a surrogate of Yb-169) was confirmed with a separate in-vitro study. Supported by DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

Perforation of the IVC: Rule Rather Than Exception After Longer Indwelling Times for the Guenther Tulip and Celect Retrievable Filters

Purpose: This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Guenther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging. Methods: Guenther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Guenther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissue injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful. Results: Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%). Conclusions: Longer indwelling times usually result in vena caval perforation by retrievable Guenther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗

Radar Back End for NASA/ISRO Synthetic Aperture Radar (NISAR) Instrument

In this paper we present design, manufacture and qualification of a Radar Back End (RBE) for NISAR Mission’s Synthetic Aperture Radar (SAR) Instrument. The instrument uses Sweep SAR technique to generate high fidelity radar images while capturing an image over a large swath. It requires highly stable clocks to accomplish that. NISAR RBE is the heart of the L-band Synthetic Aperture Radar (LSAR) instrument. It generates radar’s transmit chirp signals, ultra-stable clocks and oscillators signals. In order to generate ultra-stable clocks some novel filtering and frequency multiplication techniques were utilized. These techniques have been presented in this paper. NISAR mission requires over 200 chirps to perform science measurements. Hardware and firmware architecture utilized to generate chirps have been presented in this paper. Unique space qualified techniques for DC to DC conversion has been presented in this paper. In addition, RBE was designed to be block redundant space qualified assembly. Novel cross strapping techniques were implemented to achieve that. Validation and qualification process employed to certify RBE flight hardware for flight has been presented in this paper.