Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Ultra high bypass Nacelle aerodynamics inlet flow-through high angle of attack distortion test

A flow-through inlet test program was conducted to evaluate inlet test methods and determine the impact of the fan on inlet separation when operating at large angles of attack. A total of 16 model configurations of approximately 1/6 scale were tested. A comparison of these flow-through results with powered data indicates the presence of the fan increased separation operation 3 degrees to 4 degrees over the flow through inlet. Rods and screens located at the fan face station, that redistribute the flow, achieved simulation of the powered-fan results for separation angle of attack. Concepts to reduce inlet distortion and increase angle of attack capability were also evaluated. Vortex generators located on the inlet surface increased inlet angle of attack capability up to 2 degrees and reduced inlet distortion in the separated region. Finally, a method of simulating the fan/inlet aerodynamic interaction using blockage sizing method has been defined. With this method, a static blockage device used with a flow-through model will approximate the same inlet onset of separation angle of attack and distortion pattern that would be obtained with an inlet model containing a powered fan.

Larkin, Michael J.↗

Development of a Flow Field for Testing a Boundary-Layer-Ingesting Propulsor

In order to test embedded-propulsor technology, modifications were required of the 8x6 Supersonic Wind tunnel at NASA Glenn Research Center. The extent of the modifications required that a new tunnel calibration be completed to generate a new calibration dataset and operational procedures for the tunnel, as well as to map the boundary layer on the raised floor. This report describes the propulsor inflow that was to be simulated, documents the tunnel modifications that were required, and conveys the results of the calibration test that was completed to measure the resulting flow properties.

boundary layer↗

Flow energizer flight tests on a light twin aircraft

Experiments were conducted to explore the use of flow energizers (i.e., horizontally mounted vortex generators), using a special instrumentation subsystem installed on a light twin aircraft. The data, collected for energizer configurations with convergence ratios of 1.2, 1.5, and 1.7, included measurements of pressure on the wing surface, velocity components in the wake of the energizer, and forces on the flow energizer itself. Surface pressure data showed that flow energizer effects are highly localized. The energizer with the smallest convergence ratio tested produced an energizer lift/drag ratio about 75 percent lower that that of the other two configurations. For highly swept planforms, cambered energizers with overlaps of the order of 12-15 percent of the local chord provide the best results.

Ward, D. T.↗

Scaling and Design Analysis of a Sub-Scale, Reduced Temperature Stratified Flow Separate Effects Test Facility for the Experimental Investigation of Air Ingress in a High Temperature Reactor System

High temperature gas reactors (HTGR) are poised to spearhead the next generation of nuclear reactors, due to their passive safety characteristics and their applications flexibility. Able to provide base load power or process heat for industrial applications, HGTRs may be a critical component to reducing greenhouse gas emissions in the United States and abroad. However, increased interest and development has also highlighted areas requiring further investigation, one of which being the air-ingress accident. Air ingress may occur following a break in the coaxial cross duct and pressure vessel depressurization. The initial mode of ingress is hypothesized to be density driven cross flow as the cold air enters the lower plenum, at which point molecular diffusion and/or local buoyancy phenomena will dominate until a global natural circulation current is established. While computational simulations support this progression, little or no experimental data exists to validate and support this phenomenology. Therefore, it is necessary to generate such data; this research seeks to do so through the use of a sub-scale separate effects test facility - the Stratified Flow Separate Effects Test Facility (SFSETF). The goal of this facility is more specifically to focus on the transition to global natural circulation starting from air ingress after a double-ended guillotine break (DEGB) while neglecting depressurization. This paper will provide analyses performed in the design of this facility, including the geometric and hydraulic scaling analyses, safety analysis and instrumentation selection. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Mach number of the cosmic flow - A critical test for current theories

A new cosmological, self-contained test using the ratio of mean velocity and the velocity dispersion in the mean flow frame of a group of test objects is presented. To allow comparison with linear theory, the velocity field must first be smoothed on a suitable scale. In the context of linear perturbation theory, the Mach number M(R) which measures the ratio of power on scales larger than to scales smaller than the patch size R, is independent of the perturbation amplitude and also of bias. An apparent inconsistency is found for standard values of power-law index n = 1 and cosmological density parameter Omega = 1, when comparing values of M(R) predicted by popular models with tentative available observations. Nonstandard models based on adiabatic perturbations with either negative n or small Omega value also fail, due to creation of unacceptably large microwave background fluctuations.

Ostriker, Jeremiah P.↗

Resistively Heated Target Tests Using Helium Flow Loop

A helium flow and heat transfer experiment has been conducted using the helium flow loop facility at the Los Alamos National Laboratory. In order to replicate the helium cooled Mo-100 plant design disks during beam heating, an array of resistive heaters were placed within the helium flow loop, and cooled via helium. The resistively heated test piece is comprised of seven ceramic electric heaters with embedded thermocouples allowing temperature measurements of each heater.Computation fluid dynamic (CFD) simulations and analysis from theory are compared to the experiment results in order to have predictable capabilities for future experiments.

42 ENGINEERING↗

Apparatus and method for generating large mass flow of high temperature air at hypersonic speeds

High temperature, high mass air flow and a high Reynolds number test air flow in the Mach number 8-10 regime of adequate test flow duration is attained by pressurizing a ceramic-lined storage tank with air to a pressure of about 100 to 200 atmospheres. The air is heated to temperatures of 7,000 to 8,000 R prior to introduction into the tank by passing the air over an electric arc heater means. The air cools to 5,500 to 6,000 R while in the tank. A decomposable gas such as nitrous oxide or a combustible gas such as propane is injected into the tank after pressurization and the heated pressurized air in the tank is rapidly released through a Mach number 8-10 nozzle. The injected gas medium upon contact with the heated pressurized air effects an exothermic reaction which maintains the pressure and temperature of the pressurized air during the rapid release.

Sabol, A. P.↗

High Air-Flow Aerosol Filtration Testing

Pressure losses and aerosol collection efficiencies were measured for fibrous filter materials at air-flow rates consistent with high efficiency filtration (hundreds of cubic feet per minute). Microfiber filters coated with nanofibers were purchased and fabricated into test assemblies for a 12-inch duct system designed to mimic high efficiency filtration testing of commercial and industrial processes. Standards and specifications for high efficiency filtration were studied from a variety of institutions to assess protocols for design, testing, operations and maintenance, and quality assurance (e.g., DOE, ASHRAE, ASME). Three materials with varying Minimum Efficiency Reporting Values (MERV) were challenged with sodium chloride aerosol. Substantial filter loading was observed where aerosol collection efficiencies and pressure losses increased during experiments. Filter designs will be optimized and characterized in subsequent years of this study. Additional testing will be performed with higher hazard aerosols at Oak Ridge National Laboratory.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A flight test of laminar flow control leading-edge systems

NASA's program for development of a laminar flow technology base for application to commercial transports has made significant progress since its inception in 1976. Current efforts are focused on development of practical reliable systems for the leading-edge region where the most difficult problems in applying laminar flow exist. Practical solutions to these problems will remove many concerns about the ultimate practicality of laminar flow. To address these issues, two contractors performed studies, conducted development tests, and designed and fabricated fully functional leading-edge test articles for installation on the NASA JetStar aircraft. Systems evaluation and performance testing will be conducted to thoroughly evaluate all system capabilities and characteristics. A simulated airline service flight test program will be performed to obtain the operational sensitivity, maintenance, and reliability data needed to establish that practical solutions exist for the difficult leading-edge area of a future commercial transport employing laminar flow control.

Fischer, M. C.↗

A flight test of laminar flow control leading-edge systems

NASA's program for development of a laminar flow technology base for application to commercial transports has made significant progress since its inception in 1976. Current efforts are focused on development of practical reliable systems for the leading-edge region where the most difficult problems in applying laminar flow exist. Practical solutions to these problems will remove many concerns about the ultimate practicality of laminar flow. To address these issues, two contractors performed studies, conducted development tests, and designed and fabricated fully functional leading-edge test articles for installation on the NASA JetStar aircraft. Systems evaluation and performance testing will be conducted to thoroughly evaluate all system capabilities and characteristics. A simulated airline service flight test program will be performed to obtain the operational sensitivity, maintenance, and reliability data needed to establish that practical solutions exist for the difficult leading-edge area of a future commercial transport employing laminar flow control.

Fischer, M. C.↗

Flight Tests of a Supersonic Natural Laminar Flow Airfoil

A flight test campaign of a supersonic natural laminar flow airfoil has been recently completed. The test surface was an 80-inch (203 cm) chord and 40-inch (102 cm) span article mounted on the centerline store location of an F-15B airplane. The wing was designed with a leading edge sweep of effectively 0 deg to minimize boundary layer crossflow. The test article surface was coated with an insulating material to avoid significant heat transfer to and from the test article structure to maintain a quasi-adiabatic wall. An aircraft-mounted infrared camera system was used to determine boundary layer transition and the extent of laminar flow. The tests were flown up to Mach 2.0 and chord Reynolds numbers in excess of 30 million. The objectives of the tests were to determine the extent of laminar flow at high Reynolds numbers and to determine the sensitivity of the flow to disturbances. Both discrete (trip dots) and 2-D disturbances (forward-facing steps) were tested. A series of oblique shocks, of yet unknown origin, appeared on the surface, which generated sufficient crossflow to affect transition. Despite the unwanted crossflow, the airfoil performed well. The results indicate the sensitivity of the flow to the disturbances, which can translate into manufacturing tolerances, were similar to that of subsonic natural laminar flow wings.

Frederick, M. A.↗

F-111 natural laminar flow glove flight test data analysis and boundary layer stability analysis

An analysis of 34 selected flight test data cases from a NASA flight program incorporating a natural laminar flow airfoil into partial wing gloves on the F-111 TACT airplane is given. This analysis determined the measured location of transition from laminar to turbulent flow. The report also contains the results of a boundary layer stability analysis of 25 of the selected cases in which the crossflow (C-F) and Tollmien-Schlichting (T-S) disturbance amplification factors are correlated with the measured transition location. The chord Reynolds numbers for these cases ranges from about 23 million to 29 million, the Mach numbers ranged from 0.80 to 0.85, and the glove leading-edge sweep angles ranged from 9 deg to 25 deg. Results indicate that the maximum extent of laminar flow varies from 56% chord to 9-deg sweep on the upper surface, and from 51% chord at 16-deg sweep to 6% chord at 25-deg sweep on the lower. The results of the boundary layer stability analysis indicate that when both C-F and T-S disturbances are amplified, an interaction takes place which reduces the maximum amplification factor of either type of disturbance that can be tolerated without causing transition.

Runyan, L. J.↗

Analysis and Design of Rectangular-Cross-Section Nozzles for Scramjet Engine Testing

The flow in the square-cross-section Mach-6 nozzle used in the NASA Langley Research Center Arc-Heated Scramjet Test Facility has been analyzed using three-dimensional viscous CFD methods. The primary cause of the non-uniform flow exiting the nozzle is identified as cross-flow pressure gradients imposed on wall boundary layers. The cross-flow pressure gradients cause the boundary layer to roll up into counter-rotating vortex pairs on each of the four sides of the nozzle. These four vortex pairs produce significant non-uniformity in the nozzle-exit flow. In order to improve the quality of the test flow in the facility, two alternative nozzle designs (one axisymmetric and one rectangular with a 2-D contour) have been investigated. While the axisymmetric design produced the most uniform flow, the 2-D design also produced very good flow. The 2-D design was selected for further refinement, resulting in a new nozzle design which has been constructed and awaits calibration.

Gaffney, Richard L., Jr.↗

Preliminary Design Study for an Eddy Current Flow Meter for Versatile Test Reactor

The eddy current flow meter (ECFM) serves the purpose of monitoring velocities and temperatures of conductive liquid coolant surrounding nuclear reactor cells. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of this flow in reactor cells can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core, as well as, aid in mapping any non-uniformities in fluid flow, its temperature estimation and phase. With modeling and experimental verification, an extensible ECFM for multiple facilities and environments can lead to an understanding of the liquid coolant flow; while saving cost of calibration and development. This can be done by characterizing the ECFM performance based on its parameters and then optimizing a sensor for a given use case. Simulation results using an ECFM and an aluminum rod medium are presented and discussed herein. Additionally, liquid metal simulations for Mercury and Galinstan will compare the ECFM behavior for different liquid velocities and excitation frequencies. After sensor calibration curves are generated and experimentally verified, ECFMs can be developed and deployed using the model introduced.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fan Noise Source Diagnostic Test: LDV Measured Flow Field Results

Results are presented of an experiment conducted to investigate potential sources of noise in the flow developed by two 22-in. diameter turbofan models. The R4 and M5 rotors that were tested were designed to operate at nominal take-off speeds of 12,657 and 14,064 RPMC, respectively. Both fans were tested with a common set of swept stators installed downstream of the rotors. Detailed measurements of the flows generated by the two were made using a laser Doppler velocimeter system. The wake flows generated by the two rotors are illustrated through a series of contour plots. These show that the two wake flows are quite different, especially in the tip region. These data are used to explain some of the differences in the rotor/stator interaction noise generated by the two fan stages. In addition to these wake data, measurements were also made in the R4 rotor blade passages. These results illustrate the tip flow development within the blade passages, its migration downstream, and (at high rotor speeds) its merging with the blade wake of the adjacent (following) blade. Data also depict the variation of this tip flow with tip clearance. Data obtained within the rotor blade passages at high rotational speeds illustrate the variation of the mean shock position across the different blade passages.

Podboy, Gary C.↗

Testing to Transition the J-2X from Paper to Hardware

The J-2X Upper Stage Engine (USE) will be the first new human-rated upper stage engine since the Apollo program of the 1960s. It is designed to carry the Ares I and Ares V into orbit and send the Ares V to the Moon as part of NASA's Constellation Program. This paper will provide an overview of progress on the design, testing, and manufacturing of this new engine in 2009 and 2010. The J-2X embodies the program goals of basing the design on proven technology and experience and seeking commonality between the Ares vehicles as a way to minimize risk, shorten development times, and live within current budget constraints. It is based on the proven J-2 engine used on the Saturn IB and Saturn V launch vehicles. The prime contractor for the J-2X is Pratt & Whitney Rocketdyne (PWR), which is under a design, development, test, and engineering (DDT&E) contract covering the period from June 2006 through September 2014. For Ares I, the J-2X will provide engine start at approximately 190,000 feet, operate roughly 500 seconds, and shut down. For Ares V, the J-2X will start at roughly 190,000 feet to place the Earth departure stage (EDS) in orbit, shut down and loiter for up to five days, re-start on command and operate for roughly 300 seconds at its secondary power level to perform trans lunar injection (TLI), followed by final engine shutdown. The J-2X development effort focuses on four key areas: early risk mitigation, design risk mitigation, component and subassembly testing, and engine system testing. Following that plan, the J-2X successfully completed its critical design review (CDR) in 2008, and it has made significant progress in 2009 and 2010 in moving from the drawing board to the machine shop and test stand. Post-CDR manufacturing is well under way, including PWR in-house and vendor hardware. In addition, a wide range of component and sub-component tests have been completed, and more component tests are planned. Testing includes heritage powerpack, turbopump inducer water flow, turbine air flow, turbopump seal testing, main injector and gas generator, injector testing, augmented spark igniter testing, nozzle side loads cold flow testing, nozzle extension film cooling flow testing, control system testing with hardware in the loop, and nozzle extension emissivity coating tests. In parallel with hardware manufacturing, work is progressing on the new A-3 test stand to support full duration altitude testing. The Stennis A-2 test stand is scheduled to be turned over to the Constellation Program in September 2010 to be modified for J-2X testing also. As the structural steel was rising on the A-3 stand, work was under way in the nearby E complex on the chemical steam generator and subscale diffuser concepts to be used to evacuate the A-3 test cell and simulate altitude conditions.

Byrd, Tom↗

Scaled Rocket Testing in Hypersonic Flow

NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was strongly based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Detailed base heating results are outside of the scope of the current work, rather test methodology and techniques are presented along with broader applicability toward scaled rocket testing in supersonic and hypersonic flow.

Dufrene, Aaron↗

Utilizing Strain Rate Jump Testing to Predict Flow Formability of Al Alloys Sensitive to Portevin-Le Chatelier Instabilities

Predicting the flow formability of Al alloys is challenging due to the incremental deformation, complex loading path, and wide range of strain rates characteristic of the process. State-of-the-art research efforts have primarily focused on formability metrics derived from ambient temperature, constant strain rate uniaxial tensile testing. However, Al alloys in formable tempers tend to exhibit serrated Portevin-Le Chatelier (PLC) flow. The appearance of PLC instabilities implies a negative strain rate sensitivity, loss of tensile area reduction capacity, and decreased formability. Elevated temperature and interrupted strain rate tensile tests of relevant Al alloys were conducted to investigate the effects of rapid changes in strain rate (analogous to a forming increment by a passing roller) on common formability metrics. Emphasis was placed on the character/extent of PLC instabilities using digital image correlation strain measurements. The outcome of this work highlights the possibility of predicting flow formability using strain rate jump testing.

flow forming↗