Search NASA⌕ Search

SEARCH · Search NASA

Results for “Focal plane array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Global tropospheric and total ozone monitoring with a Double-Etalon Fabry-Perot interferometer

Knowledge of the global scale distribution of atmospheric ozone and its temporal variability can be achieved using a satellite-based nadir-viewing device making high spectral resolution measurements with high signal-to-noise ratios. This would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface and interfering species. The Fabry-Perot interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. The periodic nature of the Fabry-Perot instrument function can be advantageous when observation of periodic spectra is desired. However, for most applications, additional optical elements are necessary to reduce the effect of unwanted passbands. This is frequently accomplished using additional Fabry-Perot etalons in a series configuration in conjunction with a bandpass filter. This paper discusses a Fabry-Perot interferometer conceptual instrument design to achieve tropospheric and total ozone monitoring capability from a satellite-based nadir-viewing geometry. The design involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). The impact of inter-etalon reflections has been reduced to acceptable levels by placement of a slightly attenuating medium in between the etalons. A passive device is selected for low power consumption, and continuous day/night coverage, independent of solar zenith angle, is enabled by observing within the strong 9.6 micron ozone infrared band. The IR-FPI detection will be performed through implementation of the new Circle to Line Interferometer Optical (CLIO) system, developed by researchers at the Space Physics Research Laboratory (SPRL) of the University of Michigan, to accomplish focal plane fringe detection; the CLIO system converts the circular interferometric fringes into a linear pattern which then can be detected by conventional linear array detectors. A multiplex signal advantage is achievable as all necessary frequencies can be measured simultaneously using a multichannel configuration. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance.

Larar, Allen M.↗

Multi-element array signal reconstruction with adaptive least-squares algorithms

Two versions of the adaptive least-squares algorithm are presented for combining signals from multiple feeds placed in the focal plane of a mechanical antenna whose reflector surface is distorted due to various deformations. Coherent signal combining techniques based on the adaptive least-squares algorithm are examined for nearly optimally and adaptively combining the outputs of the feeds. The performance of the two versions is evaluated by simulations. It is demonstrated for the example considered that both of the adaptive least-squares algorithms are capable of offsetting most of the loss in the antenna gain incurred due to reflector surface deformations.

Kumar, R.↗

Conically scanned lidar telescope using holographic optical elements

Holographic optical elements (HOE) using volume phase holograms make possible a new class of lightweight scanning telescopes having advantages for lidar remote sensing instruments. So far, the only application of HOE's to lidar has been a non-scanning receiver for a laser range finder. We introduce a large aperture, narrow field of view (FOV) telescope used in a conical scanning configuration, having a much smaller rotating mass than in conventional designs. Typically, lidars employ a large aperture collector and require a narrow FOV to limit the amount of skylight background. Focal plane techniques are not good approaches to scanning because they require a large FOV within which to scan a smaller FOV mirror or detector array. Thus, scanning lidar systems have either used a large flat scanning mirror at which the receiver telescope is pointed, or the entire telescope is steered. We present a concept for a conically scanned lidar telescope in which the only moving part is the HOE which serves as the primary collecting optic. We also describe methods by which a multiplexed HOE can be used simultaneously as a dichroic beamsplitter.

Schwemmer, Geary K.↗

Development of a miniaturized, light-weight magnetic sector for a field-portable mass spectrograph

A miniaturized, lightweight magnetic sector for a focal plane mass spectrograph (Mattauch-Herzog design) has been designed and fabricated by using a new high-energy-product magnet material (Nd-B-Fe alloy) and a high permeability magnet yoke material (V-Co-Fe alloy). The magnetic sector weighs less than 10 kg, has a focal plane of 5.1 cm in length, and covers a nominal mass range of 40-240 amu. Such a magnetic sector, in conjunction with an array detector and a short microbore capillary column, is well suited for the development of a field-portable gas chromatograph-mass spectrometer instrument of high performance.

Sinha, M. P.↗

Development and Operation of the Microshutter Array System

The microshutter array (MSA) is a key component in the James Webb Space Telescope Near Infrared Spectrometer (NIRSpec) instrument. The James Webb Space Telescope is the next generation of a space-borne astronomy platform that is scheduled to be launched in 2013. However, in order to effectively operate the array and meet the severe operational requirements associated with a space flight mission has placed enormous constraints on the microshutter array subsystem. This paper will present an overview and description of the entire microshutter subsystem including the microshutter array, the hybridized array assembly, the integrated CMOS electronics, mechanical mounting module and the test methodology and performance of the fully assembled microshutter subsystem. The NIRSpec is a European Space Agency (ESA) instrument requiring four fully assembled microshutter arrays, or quads, which are independently addressed to allow for the imaging of selected celestial objects onto the two 4 mega pixel IR detectors. Each microshutter array must have no more than approx.8 shutters which are failed in the open mode (depending on how many are failed closed) out of the 62,415 (365x171) total number of shutters per array. The driving science requirement is to be able to select up to 100 objects at a time to be spectrally imaged at the focal plane. The spectrum is dispersed in the direction of the 171 shutters so if there is an unwanted open shutter in that row the light from an object passing through that failed open shutter will corrupt the spectrum from the intended object.

Jhabvala, M. D.↗

Position-Sensitive Magnetic Calorimeters for Lynx

We describe the performance of position-sensitive metallic magnetic calorimeter X-ray detectors for potential future astrophysics missions, such as Lynx. The motivation behind this is to achieve a large focal plane area by increasing the number of pixels compared to the number of readout channels (called hydra). The detector consists of a 5×5 array of gold absorbers thermally coupled to a paramagnetic sensor. Since each absorber has a different thermal link to the sensor, it generates a different pulse shape and enables discrimination of pixel position. Recently, we have been successfully able to discriminate 25 averaged pulse shapes by means of rise-time and pulse height. The measured pulse shapes and distribution agree well with the modeling results. The estimated energy resolutions based on the pulse height and noise data we measured are 2.8–3.7 eV for MnKα X-ray photons at 50 mK.

Magnetic calorimeters↗

Technologies for the multispectral mapping of earth resources

The application of solid-state detector array imaging to the remote sensing of the earth as a follow-on to currently planned Landsat missions provides the opportunity to achieve significantly increased performance. First-order advantages to be anticipated are higher sensitivity resulting in greater radiometric accuracies and improved geometric fidelity. The Multispectral Mapper design concept is responsive to a broad range of user needs by incorporating in-flight selection of spectral bands, instantaneous fields of view, and swath width. This versatility is achieved by the use of an imaging spectrometer which permits both spatial and spectral sampling in the image plane using area array detectors. Other improvements over the current Landsat multispectral scanner and Thematic Mapper include higher spatial resolution and inherently precise registration of the spectral bands. The key technologies required in order to realize these improvements include short-wavelength infrared detectors, wide field of view, broad spectral coverage optics, focal plane cooling, and high-speed onboard signal processing. Significant development activities will be required if an advanced remote sensing capability is to be implemented.

Wellman, J. B.↗

Enhancing efficiency of single, large-aperture antennas

Numerical analysis method provides means of describing energy distribution in focal plane of parabolic surface in terms of phase and wavelength. Two approaches for enhancing antenna efficiency include single, large reflector focused to feeding element, and array of smaller apertures whose individual outputs are summed.

Cohen, M.↗

Prototype Magnetic Calorimeter Arrays with Buried Wiring for the Lynx X-Ray Microcalorimeter

Metallic magnetic calorimeter (MMC) technology is a leading contender for detectors for the Lynx X-ray Microcalorimeter, which is an imaging spectrometer consisting of an array of greater than 100,000 pixels. The fabrication of such large arrays presents a challenge when attempting to route the superconducting wiring from the pixels to the multiplexed readout. If the wiring is designed to be planar, then an aggressive, submicron scale wiring pitch has to be employed, which is technically challenging to design and fabricate on account of the requirements of low inductance, low cross-talk, high critical currents and high yield. An alternative way to achieve large scale, high density wiring is through the use of multiple buried metal layers, planarized by Chemical Mechanical Planarization. This approach is well-suited for connecting thousands of pixels on a large focal plane to readout chips, and also for fabricating sensor meander coils with narrow line widths, which helps in increasing the sensor inductance and thus alleviates stray inductance issues associated with the wiring in large size arrays. In this work we describe the fabrication of high sensor inductance MMC arrays implementing Lynx concepts and incorporating multiple layers of buried Nb wiring. The detector array is composed of three sub-arrays with pixels optimized to meet the different science driven performance requirements of Lynx. In two of the sub-arrays we adopt a thermal multiplexing scheme to read out pixels by coupling 25 absorbers to a single sensor through thermal links of varied thermal conductance. We demonstrate the successful fabrication of multi-absorber MMCs with fine pitch pixels in very large size arrays.

Solid-State Physics↗

Integration, Testing and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator-class instrument for the Kitt Peak National Observatory 2.1 m and Mayall 3.8 m telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = lambda/delta lambda = 300 - 3000). On the 3.8 m telescope, IRMOS produces simultaneous spectra of approximately 100 objects in its approximately 3 x 2 arcmin field of view using a commercial micro electro-mechanical systems (MEMS) digital micro-mirror device (DMD) from Texas Instruments. The multi-mirror array DMD operates as a real-time programmable slit mask. The all-reflective optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto a large-format detector. The instrument operates at approximately 80 K, cooled by a single electro-mechanical cryocooler. The bench and all components are made from aluminum 6061-T651. There are three cryogenic mechanisms. We describe laboratory integration and test of IRMOS before shipment to Kitt Peak. We give an overview of the optical alignment technique and integration of optical, mechanical, electrical and cryogenic subsystems. We compare optical test results to model predictions of point spread function size and morphology, contrast, and stray light. We discuss some lessons learned and conclude with a prediction for performance on the telescope.

Ohl, Raymond G.↗

Lucy L’Ralph In-Flight Calibration and Results at (152830) Dinkinesh

The L'Ralph instrument is a key component of NASA's Lucy mission, intended to provide spectral image data of multiple Jupiter Trojans. The instrument operates from ∼0.35 to 4 μm using two focal plane assemblies: a 350–950 nm multispectral imager, Multi-spectral Visible Imaging Camera (MVIC), and a 0.97–4 μm imaging spectrometer, Linear Etalon Imaging Spectral Array (LEISA). Instrument calibration was established through ground testing before launch and has been monitored during cruise utilizing internal calibration sources and stellar targets. In-flight data have shown that the instrument thermal performance is exceeding expectations, allowing for early updates to LEISA radiometric and pointing calibrations. MVIC radiometric performance remains stable more than 3 yr since launch. The serendipitous identification of a new flyby target, (152830) Dinkinesh, allowed testing of instrument performance and interleaved LEISA and MVIC acquisitions on an asteroid target. Both MVIC and LEISA obtained data of Dinkinesh and its moon, Selam, demonstrating that they show good spectral agreement with an S- or Sq-type asteroid, along with evidence of a 3 μm absorption feature.

Amy A Simon↗

Miniaturized Electronic System for the Planetary Integrated Camera Spectrometer

This paper discusses the design and implementation of a miniaturized electronic system for the Planetary Integrated Camera-Spectrometer (PICS). The PICS electronics demonstrates the application of Field Programmable Gate Arrays (FPGAs) and of analog hybrid technology to space flight multispectral systems. A discussion of the electronic system design illustrates how a multisensor instrument consisting of an UV CCD, two visible CCDs, and a near-IR focal plane assembly can be processed through a common set of electronics. Following the system design discussion, the actual electronic design will be presented. Each miniaturized module will be discussed as to functionality and performance. The test setup for bench checkout of a cooled CCD and an IR FPA, including results with breadboard electronics and with the hybrids are also described.

CCD↗

Si:Bi switched photoconducttor infrared detector array

A multiplexed infrared detector array is described. The small demonstration prototype consisted of two cryogenically cooled, bismuth doped silicon, extrinsic photoconductor pixels multiplexed onto a single output channel using an on focal plane switch integration sampling technique. Noise levels of the order of 400 to 600 rms electrons per sample were demonstrated for this chip and wire hybrid version.

Eakin, C. E.↗

The Santa Barbara Research Center multimodule shortwave IR linear array and scene simulator

Alignment test results and scene simulator imagery are presented for a 1 x 1280 element linear assembly consisting of 5 end-butted modules. The modules include a Si readout chip, a 256 element photovoltaic HgCdTe detector array, and a Si/sapphire carrier. At 145 K, the operation of the LPE shortwave HgCdTE detector array yielded Resistance Area products of 420,000 ohm-sq cm. The results demonstrate the ability to fabricate high-performance, long linear multimodule shortwave IR focal planes for space applications.

Cizdziel, Philip↗

Imaging the Moon's Core with Seismology

Constraining the structure of the lunar core is necessary to improve our understanding of the present-day thermal structure of the interior and the history of a lunar dynamo, as well as the origin and thermal and compositional evolution of the Moon. We analyze Apollo deep moonquake seismograms using terrestrial array processing methods to search for the presence of reflected and converted energy from the lunar core. Although moonquake fault parameters are not constrained, we first explore a suite of theoretical focal spheres to verify that fault planes exist that can produce favorable core reflection amplitudes relative to direct up-going energy at the Apollo stations. Beginning with stacks of event seismograms from the known distribution of deep moonquake clusters, we apply a polarization filter to account for the effects of seismic scattering that (a) partitions energy away from expected components of ground motion, and (b) obscures all but the main P- and S-wave arrivals. The filtered traces are then shifted to the predicted arrival time of a core phase (e.g. PcP) and stacked to enhance subtle arrivals associated with the Moon s core. This combination of filtering and array processing is well suited for detecting deep lunar seismic reflections, since we do not expect scattered wave energy from near surface (or deeper) structure recorded at varying epicentral distances and stations from varying moonquakes at varying depths to stack coherently. Our results indicate the presence of a solid inner and fluid outer core, overlain by a partial-melt-containing boundary layer (Table 1). These layers are consistently observed among stacks from four classes of reflections: P-to-P, S-to-P, P-to-S, and S-to-S, and are consistent with current indirect geophysical estimates of core and deep mantle properties, including mass, moment of inertia, lunar laser ranging, and electromagnetic induction. Future refinements are expected following the successful launch of the GRAIL lunar orbiter and SELENE 2 lunar lander missions.

Weber, Renee C.↗

Wideband comet camera lens design

A quarter-meter diameter, modified Ritchey-Chretien camera is described for spacecraft-based observation of Halley's Comet. The system will operate over an unusually broad spectral region, from 0.1216 micron (the hydrogen Lyman-alpha line) to 1.1 microns using reflective primary and secondary mirror optics and a thin UV-grade lithium fluoride refractive element as a field corrector near the image plane. The f/12, 3000 mm focal length camera has a 0.4 deg full field of view for operation with a 15 x 15 mm charge-coupled device detector array. The UV-enhanced silicon CCD detector is a 1000 x 1000 array of 15 micron pixels which establishes the system resolution requirement. The optical design and performance are discussed, with an emphasis on the image analysis with respect to pixel resolution elements used for viewing extended objects such as comets.

Huber, E. D.↗

The X-ray Microcalorimeter Spectrometer (XMS): A Reference Cryogenic Instrument Design for Constellation-X

Constellation-X, a mission now belonging to the Beyond Einstein initiative, is being planned to inherit the x-ray sky from Chandra, XMM-Newton and Astro-E. The first two of four observatories in the constellation will be launched together in 2013 and followed a year later by the launch of the remaining two. The four will independently orbit the Sun-Earth Lagrange point L2. An instrument compliment resides in the Focal Plane Module (FPM) of each observatory 10 m from the Optics Module and consists of three Hard X-ray Telescope (HXT) detectors, a Reflection Grating Spectrometer (RGS) focal plane CCD camera and an X-ray Microcalorimeter Spectrometer (XMS). Instrument awards are scheduled for early 2006. The reference detector for XMS is a 32 x 32 array of microcalorimetric superconducting Transition Edge Sensors (TES). Each pixel casts a variable resistance in a SQUID based multiplexed readout circuit which is coupled to series SQUID arrays for amplification and finally read out by external electronics. A multi-stage continuous ADR will provide the stable 50 mK desired for the TES array and a stable 1 K for the series SQUID arrays while also lifting thermal parasitic and inefficiency loads to a 6 K cryocooler interface. The 6 K cryocooler is expected to emerge from the joint-project Advanced Cryocooler Technology Development Program (ACTDP) in which Constellation-X is an active participant. Project Pre-Formulation activities are marked by extensive technology development necessitating early, but realistic, thermal and cooling load requirements for ADR and ACTDP-cryocooler design points. Such requirements are driven by the encompassing XMS cryostat and ultimately by the thermal environment imposed by the FPM. It is further desired that the XMS instrument be able to operate on its side in the laboratory, with a warm vacuum shell, during an extensive calibration regime. It is that reference system design of the XMS instrument (microcalorimeter, ADR, cryocooler and cryostat) which is the subject of this paper.

Whitehouse, Paul L.↗

N2 Lyman-Birge-Hopfield dayglow from ATLAS 1

Spectral measurements of the far ultraviolet dayglow were made from the ATLAS 1 shuttle mission using an intensified charge coupled device (CCD) imaging spectrometer array. The instrument imaged relatively large (177 A) segments of the spectrum simultaneously and had the capability to image altitude in the second dimension of the two-dimensional focal plane detector when the entrance slit of the instrument was oriented perpendicular to the limb of the Earth. The far ultraviolet (FUV) channel of the instrument used a CsTe photocathode rather than the more conventionally used and more solar blind CsI photocathode material. As a result, the spectra were also measured with good sensitivity at FUV wavelengths longer than 1500 A. In this paper, data are selected of specific interest to a study of the N2 Lyman-Birge-Hopfield system using two shuttle attitudes: In the first the field of view was held at a fixed tangent ray height of approximately 140 km while scanning in wavelength, providing repeated FUV spectra over a range of latitudes and allowing comparison with our thermospheric airglow model. In the second observing sequence the line of sight of the instrument was scanned down through the atmosphere but covered about 75% of the full wavelength range. This sequence allows comparison of height dependence,including O2 absorption effects, with the thermospheric model. In all cases, relatively good agreement is obtained with the model (run strictly in a predictive mode) in comparisions in which the line of sight must be intergrated along a path that spans a considerable range of conditions (height, local time, latitude, solar zenith angle). In the case of the data sets examined in this study the vibrational population distributions show mixed results. In one case the distribution agrees well with a theoretical model based on direct electron impact excitation without a significant cascade contribution. A second case indicated a lower population in nu' = 3 and a higher population in nu' = 6 than would be expected from direct impact excitation alone. This supports previous indications that conditions resulting in the cascade mechanism may not always be operative.

Torr, Marsha R.↗