Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Commissioning a CT-compatible LDR tandem and ovoid applicator using Monte Carlo calculation and 3D dosimetry

Purpose: To determine the geometric and dose attenuation characteristics of a new commercially available CT-compatible LDR tandem and ovoid (T and O) applicator using Monte Carlo calculation and 3D dosimetry. Methods: For geometric characterization, we quantified physical dimensions and investigated a systematic difference found to exist between nominal ovoid angle and the angle at which the afterloading buckets fall within the ovoid. For dosimetric characterization, we determined source attenuation through asymmetric gold shielding in the buckets using Monte Carlo simulations and 3D dosimetry. Monte Carlo code MCNP5 was used to simulate 1.5 Multiplication-Sign 10{sup 9} photon histories from a {sup 137}Cs source placed in the bucket to achieve statistical uncertainty of 1% at a 6 cm distance. For 3D dosimetry, the distribution about an unshielded source was first measured to evaluate the system for {sup 137}Cs, after which the distribution was measured about sources placed in each bucket. Cylindrical PRESAGE{sup Registered-Sign} dosimeters (9.5 cm diameter, 9.2 cm height) with a central channel bored for source placement were supplied by Heuris Inc. The dosimeters were scanned with the Duke Large field of view Optical CT-Scanner before and after delivering a nominal dose at 1 cm of 5-8 Gy. During irradiation the dosimeter was placed in a water phantom to provide backscatter. Optical CT scan time lasted 15 min during which 720 projections were acquired at 0.5 Degree-Sign increments, and a 3D distribution was reconstructed with a (0.05 cm){sup 3} isotropic voxel size. The distributions about the buckets were used to calculate a 3D distribution of transmission rate through the bucket, which was applied to a clinical CT-based T and O implant plan. Results: The systematic difference in bucket angle relative to the nominal ovoid angle (105 Degree-Sign ) was 3.1 Degree-Sign -4.7 Degree-Sign . A systematic difference in bucket angle of 1 Degree-Sign , 5 Degree-Sign , and 10 Degree-Sign caused a 1%{+-} 0.1%, 1.7%{+-} 0.4%, and 2.6%{+-} 0.7% increase in rectal dose, respectively, with smaller effect to dose to Point A, bladder, sigmoid, and bowel. For 3D dosimetry, 90.6% of voxels had a 3D {gamma}-index (criteria = 0.1 cm, 3% local signal) below 1.0 when comparing measured and expected dose about the unshielded source. Dose transmission through the gold shielding at a radial distance of 1 cm was 85.9%{+-} 0.2%, 83.4%{+-} 0.7%, and 82.5%{+-} 2.2% for Monte Carlo, and measurement for left and right buckets, respectively. Dose transmission was lowest at oblique angles from the bucket with a minimum of 56.7%{+-} 0.8%, 65.6%{+-} 1.7%, and 57.5%{+-} 1.6%, respectively. For a clinical T and O plan, attenuation from the buckets leads to a decrease in average Point A dose of {approx}3.2% and decrease in D{sub 2cc} to bladder, rectum, bowel, and sigmoid of 5%, 18%, 6%, and 12%, respectively. Conclusions: Differences between dummy and afterloading bucket position in the ovoids is minor compared to effects from asymmetric ovoid shielding, for which rectal dose is most affected. 3D dosimetry can fulfill a novel role in verifying Monte Carlo calculations of complex dose distributions as are common about brachytherapy sources and applicators.

61 RADIATION PROTECTION AND DOSIMETRY↗

Observations of the Gum Nebula with a Fabry-Perot spectrometer

Scans have been made of H-alpha, 6584-A forbidden N II, 5007-A forbidden O III, and 5876-A He I emissions in selected directions in the Gum Nebula. Analyses of the line profiles and line intensities indicate that much of the emitting gas in the Gum Nebula is confined to an expanding shell which has a radius of about 125 pc, an expansion velocity of approximately 20 km/s, an emission measure which ranges from about 15 units to about 500 units, and a temperature near 11,000 K. The ultraviolet flux from zeta Pup and gamma-2 Vel appears to be capable of producing most of the observed ionization, although the origin of the shell structure and high expansion velocity is not certain.-

Reynolds, R. J.↗

WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies.

60 APPLIED LIFE SCIENCES↗

SU-D-304-05: Validation of Low-Dose-Tail Modeling for Proton Pencil Beam Spot Scanning Using a Quality Assurance Test Pattern

Purpose: The purpose of this manuscript is to demonstrate the utility of a comprehensive test pattern in validating calculation models of the low-dose tails of proton pencil beam scanning (PBS) spots. Such a pattern has been used previously for quality assurance purposes to assess spot shape and location, and for determining monitor units. Methods: In this study, a scintillation detector was used to measure the test pattern in air at isocenter for two proton beam energies (115 and 225 MeV) of two IBA universal nozzles (UN). Planar measurements were compared with calculated dose distribution based on the weighted superposition of spot profiles previously measured using a pair-magnification method. Results: Including the halo component below 1% of the central dose is shown to improve the gamma-map comparison between calculation and measurement from 94.9% to 98.4% using 2 mm/2% criteria for the 115 MeV proton beam of UN #1. In contrast, including the halo component below 1% of the central dose does not improve the gamma agreement for the 115 MeV proton beam of UN #2, due to the cutoff of the halo component at off-axis locations. When location-dependent spot profiles are used for calculation instead of spot profiles at central axis, the gamma agreement is improved from 98.0% to 99.5% using 2 mm/2% criteria. The cutoff of the halo component is smaller at higher energies, and is not observable for the 225 MeV proton beam for UN #2. Conclusion: In conclusion, the use of a comprehensive test pattern can facilitate the validation of the halo component of proton PBS spots at off axis locations. The cutoff of the halo component should be taken into consideration for large fields or PBS systems that intend to trim spot profiles using apertures. This work was supported by the US Army Medical Research and Materiel Command under Contract Agreement No. DAMD17-W81XWH-07-2-0121 and W81XWH-09-2-0174.

60 APPLIED LIFE SCIENCES↗

Book Review: Radiation protection and measurement issues related to cargo scanning with accelerator-produced high-energy X rays, NCRP Commentary No. 20

Having spent roughly the first third of his health physics career on the Norfolk, VA waterfront area, the reviewer was excited to see the NCRP Commentary 20, 'Radiation Protection and Measurements Issues Related to Cargo Scanning with Accelerator Technology'. It signals the advent of the Cargo Advanced Automated Radiography System (CAARS). The waterfront is a border that challenges physical security programs and technology. As Commentary 20 provides in the introduction, waterfront cargo terminals and land border crossings together represent over 300 ports of entry in the USA. Every year, the USA receives over 10 million cargo containers from commercial shipping and a roughly equal amount from land border crossings. While rapidly processing containerized cargo, CAARS will be able to detect small quantities of high atomic number radioactive materials and dense shielding materials used for radioactive gamma ray sources and even illicit human cargo - important concerns for homeland security. It will also be able to detect other contraband such as explosives, weapons and drugs. Section 1 of the Commentary presents an executive summary with NCRP's radiation dose management recommendations and related operational recommendations for effective implementation of CAARS technology in the current regulatory environment.

43 PARTICLE ACCELERATORS↗

SU-F-T-565: Assessment of Dosimetric Accuracy for a 3D Gel-Based Dosimetry Service

Purpose: To assess the 3D dosimetric accuracy when using a mail-in service for square and stereotactic fields in a clinical environment. Methods: The 3D dosimetry mail-in service (3DDaaS), offered by Modus QA (London, ON), was used to measure dose distributions from a 6 MV beam of a Varian Clinac. Plastic jars filled with radiosensitive ClearView™ gel were received, CT scanned (for registration and density information), irradiated, and then mailed back to the manufacturer for optical CT readout. Three square field irradiations (2×2, 4×4, and 10×10 cm{sup 2}) were performed with jars immobilized in a water tank, and a composite small-field stereotactic delivery was performed using an in-air holder. Dosimetric properties of the gel were quantified within the 25–50 Gy dose range using 3D optical attenuation (OA) distributions provided by the manufacturer. OA was normalized to 100% at the position of isocenter, which received 40Gy. Percentage depth dose, profiles, and 3D gamma distributions (3%/1mm criteria) were calculated to quantify feasibility for relative dosimetry. Results: Mean CT-measured density in the central (3×3×3) cm{sup 3} gel region was 40 ± 3 HU, indicating good homogeneity and near-water-equivalence. Measured and calculated central axis doses agreed to within ±3% in the 25–50 Gy dose range. For the square field irradiations, dose profiles agreed to within 1mm. Gamma analysis of the composite irradiation yielded 99.8%, 91.4%, and 79.1% passing rates for regions receiving at least 10, 5, and 2 Gy, respectively, indicating feasibility for use in high-dose regions. Absolute response varied by up to 16% between jars, indicating limitations for absolute dosimetry under the mail-in conditions. Conclusion: 3DDaaS is a novel near-water-equivalent dosimetry system accurate to within 3% dose and 1mm 3D spatial resolution, and is straightforward to use in a clinical setting. Future investigations are warranted to improve dosimeter response in low-dose regions. The authors would like to thank ModusQA (London, ON) for providing the gels and optical readouts used this work. This work was partially funded by NIH P01CA059827.

60 APPLIED LIFE SCIENCES↗

The beam filling error in the Nimbus 5 electronically scanning microwave radiometer observations of Global Atlantic Tropical Experiment rainfall

A comparison of rain rates retrieved from the Nimbus 5 electronically scanning microwave radiometer brightness temperatures and observed from shipboard radars during the Global Atlantic Tropical Experiment (GATE) phase I shows that the beam filling error is the major source of discrepancy between the two. When averaged over a large scene (the GATE radar array, 400 km in diameter), the beam filling error is quite stable, being 50 percent of the observed rain rate. This suggests the simple procedure of multiplying retrieved rain rates by 2 (correction factor). A statistical model of the beam filling error is developed by envisioning an idealized instrument field-of-view that encompasses an entire gamma distribution of rain rates. A modeled correction factor near 2 is found for rain rate and temperature characteristics consistent with GATE conditions. The statistical model also suggests that the correction factor varies from 1.5 to 2.5 for suppressed to enhanced tropical convective regimes, and decreases to 1.5 as the freezing level and average depth of the rain column decreases to 2.5 km.

Short, David A.↗

Mechanical Performance and Mesostructure Analysis of Proton-Irradiated Fused Filament Fabrication Acrylonitrile Butadiene Styrene Material

The use of fused filament fabrication (FFF) acrylonitrile butadiene styrene (ABS) and other thermoplastics in radiation environments is beginning to be studied as possible replacements for traditionally manufactured parts and tools. Interlayer adhesion within the mesostructure has been shown in published literature to be an integral component in the strength of FFF ABS. Research of irradiated 3D printed polymers has primarily focused on the influence of gamma irradiation on the mechanical properties of FFF ABS samples, without evaluating its impact on the mesostructure of the samples. The purpose of this paper is to understand the mechanical damage caused by proton radiation on FFF ABS samples through the evaluation of the mesostructure of the ABS samples. To achieve this objective, proton radiation at 40 MeV was applied to FFF ABS samples at radiation doses up to 1.0 MGy at a dose rate of 1 MGy/hr. Following the irradiation, tensile testing was performed on the samples. Here, the fractured surfaces of the tested samples were subsequently observed using a scanning electron microscope. The mechanical test results show an increase in the ultimate tensile strength (UTS) and a decrease in the ductility of the irradiated samples. Statistical analysis on the results shows that there is a statistically significant difference in the UTS and the ductility of unirradiated and 1.0 MGy irradiated samples and between irradiated samples and 1.0 MGy samples. In addition, the percentage elongation at break has statistically significant differences in the means between irradiated samples and 1.0 MGy samples. The UTS has statistically significant differences in the means between 0.1 MGy and 1.0 MGy. The difference in the means between the unirradiated and the 1.0 MGy samples is the most significant for both the UTS and elongation at break. The scanning electron microscopy (SEM) results indicated that interlayer adhesion improved as a function of radiation dose corresponding to the increase in tensile strength. The SEM results also showed that crazing and plastic deformation were reduced; aligning with the loss in ductility observed in the tensile tests results. The proton radiation is causing these mechanical and physical changes through two mechanisms: (1) dose rate effects on ionizing radiation-induced oxidative degradation; and (2) radiation heating effects of high energy (>1 MeV) charged particles.

electron microscopy↗

SU-F-T-142: An Analytical Model to Correct the Aperture Scattered Dose in Clinical Proton Beams

Purpose: Apertures or collimators are used to laterally shape proton beams in double scattering (DS) delivery and to sharpen the penumbra in pencil beam (PB) delivery. However, aperture-scattered dose is not included in the current dose calculations of treatment planning system (TPS). The purpose of this study is to provide a method to correct the aperture-scattered dose based on an analytical model. Methods: A DS beam with a non-divergent aperture was delivered using a single-room proton machine. Dose profiles were measured with an ion-chamber scanning in water and a 2-D ion chamber matrix with solid-water buildup at various depths. The measured doses were considered as the sum of the non-contaminated dose and the aperture-scattered dose. The non-contaminated dose was calculated by TPS and subtracted from the measured dose. Aperture scattered-dose was modeled as a 1D Gaussian distribution. For 2-D fields, to calculate the scatter-dose from all the edges of aperture, a sum of weighted distance was used in the model based on the distance from calculation point to aperture edge. The gamma index was calculated between the measured and calculated dose with and without scatter correction. Results: For a beam with range of 23 cm and aperture size of 20 cm, the contribution of the scatter horn was ∼8% of the total dose at 4 cm depth and diminished to 0 at 15 cm depth. The amplitude of scatter-dose decreased linearly with the depth increase. The 1D gamma index (2%/2 mm) between the calculated and measured profiles increased from 63% to 98% for 4 cm depth and from 83% to 98% at 13 cm depth. The 2D gamma index (2%/2 mm) at 4 cm depth has improved from 78% to 94%. Conclusion: Using the simple analytical method the discrepancy between the measured and calculated dose has significantly improved.

60 APPLIED LIFE SCIENCES↗

SU-F-T-304: Complex Multi-PTV Treatment Evaluation Using a Remotely Processed 3D Gel Dosimeter

Purpose: A new 3D gel dosimeter (ClearView™, Modus Medical Systems) was investigated for use as a QA tool for stereotactic radiosurgery (SRS) plans exhibiting high dose gradients and spatially separated treatment targets. The unique feature of this gel dosimeter is the remote processing service provided by Modus Medical Systems. Methods: The gel dosimeters were filled in either 10 cm diameter or 15 cm diameter clear plastic jars. The jars were then shipped in ice-cooled containers to our department for irradiation. Clinical SRS plans for treatment of multiple metastases and plans with simulated concave structures were applied to a CT scan of the gel dosimeter. The gel was irradiated in treatment position using modulated arcs and then returned in the cooled container for processing. The 3D gel dose was compared to the DICOM-RT dose from the treatment plan to assess dosimetric and geometric agreement. Results: There was no discernible difference between the planned and measured dose for dose gradients as high as 10%/mm, which was the highest gradient we evaluated. Geometric agreement for distant metastases separated by 6 cm was within 1.5 mm. Among three identically irradiated gels using a plan intended for nine metastases, the 3%/3mm gamma passing rate was 84.5% with a range of 14.7%, measured over the entire volume of the dosimeter. Regions of larger gamma values correlated with geometric offsets between the planned and measured data. Conclusion: The gel dosimeter exhibits the dosimetric and geometric characteristics necessary for 3D evaluation of treatment plan deliverability. The range of observed gamma passing rates suggests a high sensitivity to geometric registration. With proper management of geometric registration between planned and measured data, this service should enable a radiation oncology department to use 3D dosimetry in end-to-end testing or patient plan delivery QA without the expense of an in-house processing system.

60 APPLIED LIFE SCIENCES↗

Study of Lead Free Ferroelectric Films for New Solar Cells

We report on the deposition by a sol-gel process of Ba{sub 0.8}Sr{sub 0.2}TiO{sub 3} and Ba{sub 0.9}Sr{sub 0.1}TiO{sub 3} films on platinum coated silicon substrates. X-Ray diffraction patterns show that the films are (111) preferentially oriented. The surface morphology is smooth, without cracks and the grain size is about 50 nm as determined by AFM and SEM. The dielectric constant measured from 10{sup 2} to 10{sup 6} Hz decreases slightly and is around 400 at 10{sup 4} Hz. The losses are constant in a first approximation for a 1.5 {mu}m thick BST(80/20) film with a value of 0.03 at 10 kHz. The existence of an hysteresis cycle attests that the films, whatever their thickness, are in a ferroelectric state. Pyroelectric coefficients have been determined and the best figure of merit obtained on BST(90/10) at 293 K and 10 kHz is of 149 {mu}C/m{sup 3}/K. The best dielectric and pyroelectric properties (tg{delta} = 0.006 at 1 MHz, tunability = 30%, {gamma} = 340 {mu}C/m{sup 2}/K) were obtained on the 400 nm BST(90/10) film. Work is in progress to characterize the piezoelectric and photovoltaic properties of our BST films.

36 MATERIALS SCIENCE↗

A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy

Purpose: Measurement of actual dose delivered during radiotherapy treatment aids in checking the accuracy of dose delivered to the patient. In this study, a couch-based real time dosimetric device has been proposed to measure the exit or entrance dose to a patient during external beam radiotherapy. The utility and feasibility of such a device using a 2D array of diodes has been demonstrated. Methods: Two MAPCHECK devices: MAPCHECK (1175) and MAPCHECK 2 (both SunNuclear) were embedded in a foam block in the treatment couch of a Varian 21iX linear accelerator. The angular dependence of the detector response for both devices was studied before implementing the MAPCHECKs for experimental purposes. An Alderson Rando head phantom was scanned with the MAPCHECK and MAPCHECK 2 devices separately and four different treatment plans were generated with target volumes at three different positions simulating typical clinical situations. The analytical anisotropic algorithm (AAA) was used to compute the doses in an Eclipse treatment planning system (Varian Medical Systems). The Rando phantom with the MAPCHECK device was exposed in Clinac 21iX linear accelerator. The measured dose distribution was compared with the calculated dose distribution to check for the accuracy in dose delivery. Results: Measured and computed dose distribution were found to agree with more than 93% of pixels passing at 3% and 3 mm gamma criteria for all the treatment plans. The couch-based real time dosimetry system may also be applied for noncoplanar beams where electronic portal imaging device (EPID) is not practical to measure the dose. Other advantages include checking the beam stability during the patient treatment, performing routine morning quality assurance (QA) tests in the linear accelerator, and to perform pretreatment verification of intensity modulated radiation therapy (IMRT). One of the drawbacks of this system is that it cannot be used for measuring the dose at 90 deg. or 270 deg. gantry angles. Conclusions: This preliminary study shows that a 2D array of detectors may be used as part of the treatment couch for real time patient dosimetry in studying the dose delivered to the patient in real time and also for performing routine quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Auroral spectrum between 1200 and 4000 angstroms.

Results of spectroscopic observations of an auroral event made simultaneously by airborne and satellite-borne scanning spectrometers in the wavelength region between 1200 and 4000 A. Photon emission rates of several vibrational bands of the N2, 2nd positive, Vegard-Kaplan, and Lyman-Birge-Hopfield systems, the N I lines at 1200 and 3466 A, and O I lines at 1304, 1356, and 2972 A were recorded. Model calculations of the emission rates of the observed features are found to be in reasonable agreement with the measurements. Electron impact excites the nitrogen band systems, as well as the O I 1356-A line. A spectral feature at 2150 A is tentatively identified as the (1, 0) gamma band of N O.

Sharp, W. E.↗

The Germanium GAlactic Plane Patrol mission

The goal of the Germanium GAlactic Plane Patrol mission (GGAPP) is to provide a continuous monitor of the Galactic Plane (GP) for variable sources of gamma-ray lines. Potentially interesting sources include black hole candidates, X-ray binary systems, pulsars, gamma-ray bursts, and solar flares. The GGAPP instrument is an array of Ge detectors cooled by a mechanical refrigerator to achieve a spectral resolution of 2 keV at 1 MeV (1/500). A bismuth germanate (BGO) shield will restrict the field-of-view (FOV) to within 20 deg of the GP, and a modulation collimator system will locate strong sources to less than 0.3 deg in galactic longitude, provide a direct means of subtracting background, and mapping the diffuse emission from the GP. The spacecraft will be rotationally stabilized with the spin axis perpendicular to the GP such that the modulator scans in galactic longitude. A HEO or L1 orbit will keep GGAPP far away from the strong background produced by the Earth. GGAPP will provide a natural bridge between GRO and future missions such as INTEGRAL/NAE.

Tueller, Jack↗

SU-E-T-105: Development of 3D Dose Verification System for Volumetric Modulated Arc Therapy Using Improved Polyacrylamide-Based Gel Dosimeter

Purpose: The aim of this dosimetric study was to develop 3D dose verification system for volumetric modulated arc therapy (VMAT) using polyacrylamide-based gel (PAGAT) dosimeter improved the sensitivity by magnesium chloride (MgCl{sub 2}). Methods: PAGAT gel containing MgCl{sub 2} as a sensitizer was prepared in this study. Methacrylic-acid-based gel (MAGAT) was also prepared to compare the dosimetric characteristics with PAGAT gel. The cylindrical glass vials (4 cm diameter, 12 cm length) filled with each polymer gel were irradiated with 6 MV photon beam using Novalis Tx linear accelerator (Varian/BrainLAB). The irradiated polymer gel dosimeters were scanned with Signa 1.5 T MRI system (GE), and dose calibration curves were obtained using T{sub 2} relaxation rate (R{sub 2} = 1/T{sub 2}). Dose rate (100-600 MU min{sup −1}) and fractionation (1-8 fractions) were varied. In addition, a cubic acrylic phantom (10 × 10 × 10 cm{sup 3}) filled with improved PAGAT gel inserted into the IMRT phantom (IBA) was irradiated with VMAT (RapidArc). C-shape structure was used for the VMAT planning by the Varian Eclipse treatment planning system (TPS). The dose comparison of TPS and measurements with the polymer gel dosimeter was accomplished by the gamma index analysis, overlaying the dose profiles for a set of data on selected planes using in-house developed software. Results: Dose rate and fractionation dependence of improved PAGAT gel were smaller than MAGAT gel. A high similarity was found by overlaying the dose profiles measured with improved PAGAT gel dosimeter and the TPS dose, and the mean pass rate of the gamma index analysis using 3%/3 mm criteria was achieved 90% on orthogonal planes for VMAT using improved PAGAT gel dosimeter. Conclusion: In-house developed 3D dose verification system using improved polyacrylamide-based gel dosimeter had a potential as an effective tool for VMAT QA.

60 APPLIED LIFE SCIENCES↗

Performance of a Novel Repositioning Head Frame for Gamma Knife Perfexion and Image-Guided Linac-Based Intracranial Stereotactic Radiotherapy

Purpose: To evaluate the geometric positioning and immobilization performance of a vacuum bite-block repositioning head frame (RHF) system for Perfexion (PFX-SRT) and linac-based intracranial image-guided stereotactic radiotherapy (SRT). Methods and Materials: Patients with intracranial tumors received linac-based image-guided SRT using the RHF for setup and immobilization. Three hundred thirty-three fractions of radiation were delivered in 12 patients. The accuracy of the RHF was estimated for linac-based SRT with online cone-beam CT (CBCT) and for PFX-SRT with a repositioning check tool (RCT) and offline CBCT. The RCT's ability to act as a surrogate for anatomic position was estimated through comparison to CBCT image matching. Immobilization performance was evaluated daily with pre- and postdose delivery CBCT scans and RCT measurements. Results: The correlation coefficient between RCT- and CBCT-reported displacements was 0.59, 0.75, 0.79 (Right, Superior, and Anterior, respectively). For image-guided linac-based SRT, the mean three-dimensional (3D) setup error was 0.8 mm with interpatient ({Sigma}) and interfraction ({sigma}) variations of 0.1 and 0.4 mm, respectively. For PFX-SRT, the initial, uncorrected mean 3D positioning displacement in stereotactic coordinates was 2.0 mm, with {Sigma} = 1.1 mm and {sigma} = 0.8 mm. Considering only RCT setups <1mm (PFX action level) the mean 3D positioning displacement reduced to 1.3 mm, with {Sigma} = 0.9 mm and {sigma} = 0.4 mm. The largest contributing systematic uncertainty was in the superior-inferior direction (mean displacement = -0.5 mm; {Sigma} = 0.9 mm). The largest mean rotation was 0.6{sup o} in pitch. The mean 3D intrafraction motion was 0.4 {+-} 0.3 mm. Conclusion: The RHF provides excellent immobilization for intracranial SRT and PFX-SRT. Some small systematic uncertainties in stereotactic positioning exist and must be considered when generating PFX-SRT treatment plans. The RCT provides reasonable surrogacy for internal anatomic displacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the Fe-Doped Mixed-Valent Tunnel Structure 2 Manganese Oxide KOMS-2

A sol-gel-assisted combustion method was used to prepare Fe-doped manganese oxide octahedral molecular sieve (Fe-KOMS-2) materials with the cryptomelane structure. Characterization of the nanopowder samples over a wide range of Fe-doping levels (0 {le} Fe/Mn {le} 1/2) was carried out using a variety of experimental techniques. For each sample, Cu K{alpha} XRD and ICP-AES were used to index the cryptomelane structure and determine the elemental composition, respectively. A combination of SEM and TEM images revealed that the morphology changes from nanoneedle to nanorod after Fe doping. Furthermore, TGA scans indicated that the thermal stability is also enhanced with the doping. Anomalous XRD demonstrated that the Fe ions replace the Mn ions in the cryptomelane structure, particularly in the (211) planes, and results in a lattice expansion along the c axis, parallel to the tunnels. Reasonable fits to EXAFS data were obtained using a model based on the cryptomelane structure. Moessbauer spectra for selected Fe-KOMS-2 samples indicated that the Fe is present as Fe{sup 3+} in an octahedral environment similar to Mn in the MnO{sub 6} building blocks of KOMS-2. Magnetization measurements detected a small amount of {gamma}-Fe{sub 2}O{sub 3} second phase (e.g., 0.6 wt % for the Fe/Mn = 1/10 sample), the vast majority of the Fe being in the structure as Fe{sup 3+} in the high-spin state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Central Engine of GRB 130831A and the Energy Breakdown of a Relativistic Explosion

Gamma-ray bursts (GRBs) are the most luminous explosions in the Universe, yet the nature and physical properties of their energy sources are far from understood. Very important clues, however, can be inferred by studying the afterglows of these events. We present optical and X-ray observations of GRB 130831A obtained by Swift, Chandra, Skynet, Reionization And Transients Infra-Red camera, Maidanak, International Scientific Optical-Observation Network, Nordic Optical Telescope, Liverpool Telescope and Gran Telescopio Canarias. This burst shows a steep drop in the X-ray light curve at asymptotically equal to 10(exp 5) s after the trigger, with a power-law decay index of alpha that is approximately 6. Such a rare behaviour cannot be explained by the standard forward shock (FS) model and indicates that the emission, up to the fast decay at 10(exp 5) s, must be of internal origin, produced by a dissipation process within an ultrarelativistic outflow. We propose that the source of such an outflow, which must produce the X-ray flux for an asymptotically equal to 1 d in the cosmological rest frame, is a newly born magnetar or black hole. After the drop, the faint X-ray afterglow continues with a much shallower decay. The optical emission, on the other hand, shows no break across the X-ray steep decrease, and the late-time decays of both the X-ray and optical are consistent. Using both the X-ray and optical data, we show that the emission after an asymptotically equal to 10(exp 5) scan be explained well by the FS model. We model our data to derive the kinetic energy of the ejecta and thus measure the efficiency of the central engine of a GRB with emission of internal origin visible for a long time. Furthermore, we break down the energy budget of this GRB into the prompt emission, the late internal dissipation, the kinetic energy of the relativistic ejecta,and compare it with the energy of the associated supernova, SN 2013 fu.

radiation mechanisms: non-thermal – shock waves ↗