Search NASA⌕ Search

SEARCH · Search NASA

Results for “High loading rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Cyclic-load crack growth in ASME SA-105 grade II steel in high-pressure hydrogen at ambient temperature

ASME SA-105 Grade II steel, which is used in high-pressure hydrogen compressor systems, is similar to steels used or considered for use in high-pressure hydrogen storage vessels and pipelines. This paper summarizes the results of a program conducted to provide cyclic-load crack growth rate (da/dN) data for a fracture mechanics analysis of a 15,000 psi hydrogen compressor facility which contains pulse quieter and after-cooler separator vessels constructed of the ASME SA-105 Grade II steel. Included in the program were tests performed to assist in establishing operating procedures that could minimize the effect of hydrogen on crack growth rates during operation.

Walter, R. J.↗

Cognitive and affective components of mental workload: Understanding the effects of each on human decision making behavior

Human factors and ergonomics researchers have recognized for some time the increasing importance of understanding the role of the construct of mental workload in flight research. Current models of mental workload suggest that it is a multidimensional and complex construct, but one that has proved difficult to measure. Because of this difficulty, emphasis has usually been placed on using direct reports through subjective measures such as rating scales to assess levels of mental workload. The NASA Task Load Index (NASA/TLX, Hart and Staveland) has been shown to be a highly reliable and sensitive measure of perceived mental workload. But a problem with measures like TLX is that there is still considerable disagreement as to what it is about mental workload that these subjective measures are actually measuring. The empirical use of subjective workload measures has largely been to provide estimates of the cognitive components of the actual mental workload required for a task. However, my research suggests that these measures may, in fact have greater potential in accurately assessing the affective components of workload. That is, for example, TLX may be more likely to assess the positive and negative feelings associated with varying workload levels, which in turn may potentially influence the decision making behavior that directly bears on performance and safety issues. Pilots, for example, are often called upon to complete many complex tasks that are high in mental workload, stress, and frustration, and that have significant dynamic decision making components -- often ones that involve risk as well.

Nygren, Thomas E.↗

Zero-Gravity Locomotion Simulators: New Ground-Based Analogs for Microgravity Exercise Simulation

Maintaining health and fitness in crewmembers during space missions is essential for preserving performance for mission-critical tasks. NASA's Exercise Countermeasures Project (ECP) provides space exploration exercise hardware and monitoring requirements that lead to devices that are reliable, meet medical, vehicle, and habitat constraints, and use minimal vehicle and crew resources. ECP will also develop and validate efficient exercise prescriptions that minimize daily time needed for completion of exercise yet maximize performance for mission activities. In meeting these mission goals, NASA Glenn Research Center (Cleveland, OH, USA), in collaboration with the Cleveland Clinic (Cleveland, Ohio, USA), has developed a suite of zero-gravity locomotion simulators and associated technologies to address the need for ground-based test analog capability for simulating in-flight (microgravity) and surface (partial-gravity) exercise to advance the health and safety of astronaut crews and the next generation of space explorers. Various research areas can be explored. These include improving crew comfort during exercise, and understanding joint kinematics and muscle activation pattern differences relative to external loading mechanisms. In addition, exercise protocol and hardware optimization can be investigated, along with characterizing system dynamic response and the physiological demand associated with advanced exercise device concepts and performance of critical mission tasks for Exploration class missions. Three zero-gravity locomotion simulators are currently in use and the research focus for each will be presented. All of the devices are based on a supine subject suspension system, which simulates a reduced gravity environment by completely or partially offloading the weight of the exercising test subject s body. A platform for mounting treadmill is positioned perpendicularly to the test subject. The Cleveland Clinic Zero-g Locomotion Simulator (ZLS) utilizes a pneumatic subject load device to apply a near constant gravity-replacement load to the test subject during exercise, and is currently used in conjunction with the General Clinical Research Center for evaluating exercise protocols using a bedrest analog. The enhanced ZLS (eZLS) at NASA Glenn Research Center features an offloaded treadmill that floats on a thin film of air and interfaces to a force reaction frame via variably-compliant isolators, or vibration isolation system. The isolators can be configured to simulate compliant interfaces to the vehicle, which affects mechanical loading to crewmembers during exercise, and has been used to validate system dynamic models for new countermeasures equipment designs, such as the second International Space Station treadmill slated for use in 2010. In the eZLS, the test subject and exercise device can be pitched at the appropriate angle for partial gravity simulations, such as lunar gravity (1/6th earth gravity). On both the eZLS and the NASA-Johnson Space Center standalone ZLS installed at the University of Texas Medical Branch in Galveston, Texas, USA, the subject's body weight relative to the treadmill is controlled via a linear motor subject load device (LM-SLD). The LM-SLD employs a force-feedback closed-loop control system to provide a relatively constant force to the test subject during locomotion, and is set and verified for subject safety prior to each session. Locomotion data were collected during parabolic flight and on the eZLS. The purpose was to determine the similarities and differences between locomotion in actual and simulated microgravity. Subjects attained greater amounts of hip flexion during walking and running during parabolic flight. During running, subjects had greater hip range of motion. Trunk motion was significantly less on the eZLS than during parabolic flight. Peak impact forces, loading rate, and impulse were greater on the eZLS than during parabolic while walking with a low external load (EL) and rning with a high EL. Activation timing differences existed between locations in all muscles except for the rectus femoris. The tibialis anterior and gluteus maximus were active for longer durations on the eZLS than in parabolic flight during walking. Ground reaction forces were greater with the LM-SLD than with bungees during eZLS locomotion. While the eZLS serves as a ground-based analog, researchers should be aware that subtle, but measurable, differences in kinematics and leg musculature activities exist between the environments. Aside from space applications, zero-gravity locomotion simulators may help medical researchers in the future with development of rehabilitative or therapeutic protocols for injured or ill patients. Zero-gravity locomotion simulators may be used as a ground-based test bed to support future missions for space exploration, and eventually may be used to simulate planetary locomotion in partial gravity environments, including the Moon and Mars. Figure: Zero-gravity Locomotion Simulator at the Cleveland Clinic, Cleveland, Ohio, USA

Perusek, Gail P.↗

A highly active and Cr-resistant infiltrated cathode for practical solid oxide fuel cells

A critical obstacle to the commercialization of modern solid oxide fuel cells (SOFCs) loaded with metallic interconnects is the unacceptable degradation rate resulting from Cr (an element richly present in metallic interconnects) volatilization and its subsequent reaction with the cathode, forming insulating SrCrO 4 that blocks oxygen reduction reaction (ORR) active sites. Here we report a Cr-tolerant, yet ORR-active, cathode for sustainable operation of solid oxide fuel cells (SOFCs). The new resilient cathode consists of a continuous, nanoscaled, ORR-active SrCo 0.9 Ta 0.1 O 3–δ (SCT) as the capping layer and a commercial (La 0.6 Sr 0.4 ) 0.95 Co 0.2 Fe 0.8 O 3–δ (LSCF)–Ce 0.8 Gd 0.2 O 1.9 (GDC) composite as the underlying skeleton. Stability testing in a high-Cr-content environment shows that the cathode has a remarkable resistance to Cr-attack while retaining superior ORR activity. In conclusion, a successful implantation of this bilayer cathode into practical SOFC stacks will advance the commercialization of SOFC technology.

25 ENERGY STORAGE↗

Near infrared radio-luminescence of O{sub 2} loaded radiation hardened silica optical fibers: A candidate dosimeter for harsh environments

We report on an experimental investigation of the infrared Radio-Luminescence (iRL) emission of interstitial O{sub 2} molecules loaded in radiation hardened pure-silica-core and fluorine-doped silica-based optical fibers (OFs). The O{sub 2} loading treatment successfully dissolved high concentrations of oxygen molecules into the silica matrix. A sharp luminescence at 1272 nm was detected when 2.5 cm of the treated OFs were irradiated with 10 keV X-rays. This emission originates from the radiative decay of the first excited singlet state of the embedded O{sub 2} molecules. The dose, dose-rate, and temperature dependencies of the infrared emission are studied through in situ optical measurements. The results show that the iRL is quite stable in doses of up to 1 MGy(SiO{sub 2}) and is linearly dependent on the dose-rate up to the maximum investigated dose-rate of ∼200 kGy(SiO{sub 2})/h. The temperature dependency of the iRL shows a decrease in efficiency above 200 °C, which is attributed to the non-radiative decay of the excited O{sub 2} molecules. The results obtained and the long-term stability of the O{sub 2}-loading treatment (no out-gassing effect) strongly suggest the applicability of these components to real-time remote dosimetry in environments characterized by high radiation doses and dose-rates.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of lubrication on the performance of high speed spur gears

An experimental analysis was conducted to determine power loss and gear noise of high speed spur gears with long addendum under various conditions of load, speed, and oil jet pressure for into mesh lubrication. Power losses were calculated from temperature measurements of lubricating oil, gears, gear box, and oil flow rate. Furthermore, power loss was divided into windage loss, friction loss and churning loss. The results show that windage loss and churning loss were the main components of gear power loss of high gear speed. In addition, lubricating conditions had some influences on gear noise especially under low oil temperature or high viscosity.

Mizutani, Hachiro↗

Effects of lubrication on the performance of high speed spur gears

An experimental analysis was conducted to determine power loss and gear noise of high speed spur gears with long addendum under various conditions of load, speed, and oil jet pressure for into mesh lubrication. Power losses were calculated from temperature measurements of lubricating oil, gears, gear box, and oil flow rate. Furthermore, power loss was divided into windage loss, friction loss and churning loss. The results show that windage loss and churning loss were the main components of gear power loss of high gear speed. In addition, lubricating conditions had some influences on gear noise especially under low oil temperature or high viscosity.

Mizutani, H.↗

Effects of Blending and In-Tank Pretreatment on Direct Feed Hanford High Level Waste Vitrification - 18434

A direct feed high level waste (DFHLW) option is under consideration for early operations of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). In this option, the Pretreatment Facility would be bypassed in order to support an earlier start-up of the HLW Vitrification Facility. For HLW, this would mean that ultrafiltration and caustic leaching that would otherwise have been performed either would not be performed or would be replaced by interim pretreatment functions such as in-tank washings. These changes could result in higher aluminum contents, higher chromium contents, higher fractions of supernate, and lower solids contents in the HLW feed. As a result, glass formulations and downstream vitrification operations will be impacted. In the present work, we investigate the effects of various waste blending and in-tank pretreatment scenarios on DFHLW glass waste loadings, canister counts, and processing rates. Eleven source tanks and five waste groups were selected for the studies of waste blending. In addition, the five waste groups selected were the subjects of an in-tank pretreatment study. Glass property-composition models and melter test data were used to calculate waste loadings, canister counts, processing rates, and treatment durations for a range of DFHLW scenarios. The processing scenarios were defined by the types of waste blending and in-tank pretreatment that were assumed. Blending cases were evaluated that ranged between the 'No Blend' and 'Total Blend' extremes and included pairwise blending (blending of two source tanks, either completely or in various proportions) and macro-batches formed from various combinations of the source tanks. Over 36,000 possible pairwise blending scenarios were evaluated and an optimal retrieval/blending sequence was identified. The waste loading of this optimal sequence is within 0.03 wt% of the 'Total Blend' case. Further, a total of 38 retrieval sequences were identified that have waste loadings within 0.1 wt% of the 'Total Blend' case. To evaluate the effects of in-tank pretreatment, an in-tank wash/settle/decant process was assumed and tank-specific wash factors were employed. Washing of the macro-batch blends gave a general increase in HLW loading, decrease in canister count, and decrease in glass yield. Glass yields are towards the low end of the values expected for the WTP, which could lead to lower than nominal glass production rates. The waste loading increases and canister count reductions with washing were small for two of the wastes indicating that direct treatment of the unwashed waste may be practical. For wastes that are relatively low in sulfate and halides, excessive washing is counterproductive. The results highlight the importance of maintaining high solids content in the HLW feed to maintain glass production rates. The results also illustrate that the optimum washing strategy will need to be evaluated on a tank-to-tank basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanical Behavior of D-Shaped Hiperco Specimens under Tension Measured by Digital Image Correlation

Hiperco, manufactured by Carpenter Technology Corporation, is the trademark name for an alloy of equal composition iron and cobalt, with 2 percent vanadium added for enhanced mechanical properties (49Fe-49Co-2V). The alloy is interesting due to its very high magnetic saturation and flux density, yet undesirable mechanical properties such as brittleness and low strength. Several Hiperco specimens cut to a "D”-shaped geometry were placed under tension in a load frame, with a constant strain rate at room temperature, until failure occurred. Digital image correlation was used to obtain strain field data throughout the experiment. The data is to be used to compare with a finite element model, to investigate if Hiperco's unusual behavior can be modeled accurately with chosen model parameters. Between the five specimens tested, high-level results were consistent. Maximum strain and ultimate tensile strength all fell within acceptable bounds. However, several qualitative results differed from specimen to specimen. These differing results include the point of failure, the start point of Liiders band formation, as well as the presence or absence of Liiders bands on the curved section of the "D” specimens.

36 MATERIALS SCIENCE↗

The effects of Suspended Sediment on Japanese Medaka (Oryzias latipes) and Mosquitofish (Gambusia affinis) Metabolism

Sedimentation is recognized as a significant environmental stressor in aquatic ecosystems and high amounts of suspended sediments (SS) in streams are known to negatively affect aquatic organisms. In particular, it has been hypothesized that many fish species may exhibit increased respiration rates when exposed to elevated SS. To evaluate this hypothesis, we evaluated the acute response (3 hour exposure) of two small, freshwater fish species exposed to high suspended sediment loads using experimental respirometry chambers which measure oxygen consumption as a proxy of metabolism. Our results indicate that Japanese Medaka (Oryzias latipes) did not exhibit a significantly greater oxygen consumption, as compared to control fish, when exposed to chamber sediment of 0.17 g/L (p-value of 0.41), though oxygen consumption was higher for sediment treatments. However, mosquitofish (Gambusia affinis) exposed to 0.17 g/L did exhibit noticeably greater oxygen consumption compared to fish in no-sediment control test, but not at statistically significant levels (p-value of 0.07). In this work, further study is needed with increased sample sizes and across SS levels to determine the threshold of increased metabolic rate among freshwater species exposed to SS.

59 BASIC BIOLOGICAL SCIENCES↗

Impact resistance of fiber composites

Stress-strain curves are obtained for a variety of glass fiber and carbon fiber reinforced plastics in dynamic tension, over the stress-strain range of 0.00087-2070/sec. The test method is of the one-bar block-to-bar type, using a rotating disk or a pendulum as the loading apparatus and yielding accurate stress-strain curves up to the breaking strain. In the case of glass fiber reinforced plastic, the tensile strength, strain to peak impact stress, total strain and total absorbed energy all increase significantly as the strain rate increases. By contrast, carbon fiber reinforced plastics show lower rates of increase with strain rate. It is recommended that hybrid composites incorporating the high strength and rigidity of carbon fiber reinforced plastic with the high impact absorption of glass fiber reinforced plastics be developed for use in structures subjected to impact loading.

Chamis, C. C.↗

Predicting nepheline precipitation in waste glasses using ternary submixture model and machine learning

Nepheline precipitation in nuclear waste glasses during vitrification can be detrimental due to its negative effect on chemical durability. Developing models to accurately predict nepheline precipitation from compositions is important to increase waste loading since existing models can be overly conservative. In this study, an expanded dataset containing 955 glasses was compiled from literature data, where 355 glasses are for high-level waste (HLW). Previously developed submixture models were refitted using the new dataset, where a misclassification rate of 7.8% was achieved. Nine machine learning (ML) algorithms (e.g., k-nearest neighbor, Gaussian process regression, artificial neural network, support vector machine, decision tree, etc.) were applied to evaluate their ability of predicting nepheline precipitation from compositions. Model accuracy, precision, recall/sensitivity, and F1 score were systemically compared between different ML algorithms and modeling protocols. Good model prediction with an accuracy ~0.9 (misclassification rate of ~10%) was observed with different algorithms under certain protocol. This study evaluated various ML models to predict nepheline precipitations in waste glasses, highlighting the importance of data preparation, modeling protocol, and their effect on model stability and reproducibility. The results provide insights into applying ML to predict glass properties and suggest areas for future research on modeling nepheline precipitations.

Lu, Xiaonan↗

Frequency–Magnitude Statistics of Laboratory Foreshocks Vary With Shear Velocity, Fault Slip Rate, and Shear Stress

Understanding the nucleation phase of earthquakes is key for advancing earthquake hazard assessment and improving earthquake early warning systems. However, little progress has been made in this area due to a poor understanding of nucleation processes and incomplete seismic and fault zone measurements. The ability to integrate measured fault zone properties with seismic data could significantly improve our understanding of how earthquakes begin and whether there are systematic variations in seismic properties preceding failure. In this work, we use high-resolution laboratory measurements of fault zone properties along with acoustic emission data to document temporal variations of foreshock properties. Our data show that foreshock size increases with shear stress, loading rate, and fault slip rate. We propose that the preseismic fault slip rate and fault zone thickness (i.e., porosity) work in concert to modulate foreshock properties.

15 GEOTHERMAL ENERGY↗

Instrumentation and data acquisition for full-scale aircraft crash testing

The Landing and Impact Dynamics Branch of the NASA Langley Research Center has been conducting full-scale aircraft crash tests since the 1970s. Using a pendulum method, aircraft are suspended by cables from a 240-ft high gantry and swung into the impact surface at various attitudes and velocities. Instrumentation for these tests include on-board high-speed cameras, strain gages, load cells, displacement transducers, and accelerometers. Transducers in the aircraft are hard-wired through a long umbilical cable to the data acquisition room. Up to 96 channels of data can be collected at a typical rate of 4000 samples per second. Data acquisition using an FM multiplexed analog system and a high-speed personal computer based digital system is described.

Jones, Lisa E.↗

Grain reorientation and stress-state evolution during cyclic loading of an α -Ti alloy below the elastic limit

Here, high-energy synchrotron x-rays are used to track grain-averaged lattice reorientation and stress-state evolution in Ti–7Al as it is cyclically loaded to 90% of its macroscopic yield stress. This evolution provides clear indication of accumulating plastic strain even though the sample never exceeded the elastic limit. The largest changes in lattice orientation and stress state are observed following the first cycle then evolution continues at a lower rate with subsequent cycles. Variation of the axes about which lattice reorientation occurs is found to be highly dependent on the maximum resolved shear stress and corresponding activation of various families of slip systems.

36 MATERIALS SCIENCE↗

The Impact of Operational Strategies and Load Fluctuations on Anion Exchange Membrane Water Electrolyzer Degradation

This study reports on the durability of anion exchange membrane water electrolyzers (AEMWEs) at the cell level in a supporting electrolyte (1 M) and the impact of operational profiles on cell degradation. While constant load shows significant voltage loss, including a current hold at 1 A cm −2 and a potential hold at 2 V, it generally occurs in the first 70 h of testing. These losses are likely due to passivation altering site reactivity and cell kinetics, and are largely recoverable upon load cycling and diagnostics at the end of test. Furthermore, square and triangular-wave cycling do not show cell degradation and indicate that AEMWEs are not vulnerable to load cycling. When operating outside of this potential window (1.45–2 V), cell voltage decay rates markedly increase and the losses are not recoverable. This includes a current density hold at 4.0 A cm −2 with high cell voltages (>2.4 V for test duration) and cycling between 0 and 2 V to simulate start–stop, where more than a 50% loss in current density occurs over 50 h. The findings presented here demonstrate the high durability of AEMWEs, particularly when operating with load fluctuations, and may allow for durability advantages compared to iridium and proton exchange membrane systems.

08 HYDROGEN↗

High speed interference heating loads and pressure distributions resulting from elevon deflections

Effects of elevon-induced three-dimensional shock-wave turbulent boundary-layer interactions on hypersonic aircraft surfaces are analyzed. Detailed surface pressure and heating rate distributions obtained on wing-elevon-fuselage models representative of aft portions of hypersonic aircraft are compared with analytical and experimental results from other sources. Examples are presented that may be used to evaluate the adequacy of current theoretical methods for estimating the effects of three-dimensional shock-wave turbulent boundary-layer interactions on hypersonic aircraft surfaces.

Johnson, C. B.↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗