GPU-based implementations of the noniterative regularized-CCSD(T) corrections: applications to strongly correlated systems

The details of the Graphical Processing Unit (GPU) implementation of the most compu- tationally intensive (T)-part of the recently introduced regularized CCSD(T) (Reg-CCSD(T)) method [K. Kowalski, M.Valiev 131, 234107 (2010)] for calculating electronic energies of strongly interacting systems are discussed. Parallel tests performed for several molecular systems show very good scalability of the triples part of the Reg-CCSD(T) approach. We also discuss the performance of the Reg-CCSD(T) GPU implementation as a function of the parameters defining the partitioning of the spinorbital domain (tiling structure). The accuracy of the Reg-CCSD(T) method is illustrated on two examples: the NiO2 molecule and open-shell Spiro cation (5,5’(4H,4H’)-spirobi[cyclopenta[c]pyrrole]2,2’,6,6’-tetrahydro cation), which is a frequently used model to study electron transfer processes. It is demonstrated that a simple regularization of the cluster amplitudes used in the non-iterative corrections accounting for the effect of triply excited configurations significantly improves the accuracies of groundstate energies in the presence of strong quasidegeneracy effects. For NiO2 we compare the Reg-CCSD(T) results with the CCSDT energies, whereas for Spiro cation we compare Reg-CCSD(T) results with the energies obtained with completely renormalized CCSD(T) method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parallel implementation of multireference coupled-cluster theories based on the reference-level parallelism

A novel algorithm for implementing general type of multireference coupled-cluster (MRCC) theory based on the Jeziorski-Monkhorst exponential Ansatz [B. Jeziorski, H.J. Monkhorst, Phys. Rev. A 24, 1668 (1981)] is introduced. The proposed algorithm utilizes processor groups to calculate the equations for the MRCC amplitudes. In the basic formulation each processor group constructs the equations related to a specific subset of references. By flexible choice of processor groups and subset of reference-specific sufficiency conditions designated to a given group one can assure optimum utilization of available computing resources. The performance of this algorithm is illustrated on the examples of the Brillouin-Wigner and Mukherjee MRCC methods with singles and doubles (BW-MRCCSD and Mk-MRCCSD). A significant improvement in scalability and in reduction of time to solution is reported with respect to recently reported parallel implementation of the BW-MRCCSD formalism [J.Brabec, H.J.J. van Dam, K. Kowalski, J. Pittner, Chem. Phys. Lett. 514, 347 (2011)].

99 GENERAL AND MISCELLANEOUS↗

Assuring the Quality of Test Results in the Field of Nuclear Techniques and Ionizing Radiation. The Practical Implementation of Section 5.9 of the EN ISO/IEC 17025 Standard

The paper aims to present a practical approach for testing laboratories to ensure the quality of their test results. It is based on the experience gained in assessing a large number of testing laboratories, discussing with management and staff, reviewing results obtained in national and international PTs and ILCs and exchanging information in the EA laboratory committee.According to EN ISO/IEC 17025, an accredited laboratory has to implement a programme to ensure the quality of its test results for each measurand. Pre-analytical, analytical and post-analytical measures shall be applied in a systematic manner. They shall include both quality control and quality assurance measures.When designing the quality assurance programme a laboratory should consider pre-analytical activities (like personnel training, selection and validation of test methods, qualifying equipment), analytical activities ranging from sampling, sample preparation, instrumental analysis and post-analytical activities (like decoding, calculation, use of statistical tests or packages, management of results).Designed on different levels (analyst, quality manager and technical manager), including a variety of measures, the programme shall ensure the validity and accuracy of test results, the adequacy of the management system, prove the laboratory's competence in performing tests under accreditation and last but not least show the comparability of test results.Laboratory management should establish performance targets and review periodically QC/QA results against them, implementing appropriate measures in case of non-compliance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation on a desktop computer of the real time feedback control loop of a scanning probe microscope

A software package has been developed to implement the real time feedback control loop needed in scanning probe microscopy on a general purpose desktop computer of the current high-speed/multicore generation. The main features of the implementation of both the feedback loop and the control of the experiment on the same computer are discussed. The package can work with several general purpose data acquisition boards and can be extended in a modular way to further board models; timing performance has been tested with several hardware configurations and some applications common in scanning probe microscopy. The package is available under an Open Source license.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-photon absorption cross sections within equation-of-motion coupled-cluster formalism using resolution-of-the-identity and Cholesky decomposition representations: Theory, implementation, and benchmarks

The equation-of-motion coupled-cluster (EOM-CC) methods provide a robust description of electronically excited states and their properties. Here, we present a formalism for two-photon absorption (2PA) cross sections for the equation-of-motion for excitation energies CC with single and double substitutions (EOM-CC for electronically excited states with single and double substitutions) wave functions. Rather than the response theory formulation, we employ the expectation-value approach which is commonly used within EOM-CC, configuration interaction, and algebraic diagrammatic construction frameworks. In addition to canonical implementation, we also exploit resolution-of-the-identity (RI) and Cholesky decomposition (CD) for the electron-repulsion integrals to reduce memory requirements and to increase parallel efficiency. The new methods are benchmarked against the CCSD and CC3 response theories for several small molecules. We found that the expectation-value 2PA cross sections are within 5% from the quadratic response CCSD values. The RI and CD approximations lead to small errors relative to the canonical implementation (less than 4%) while affording computational savings. RI/CD successfully address the well-known issue of large basis set requirements for 2PA cross sections calculations. The capabilities of the new code are illustrated by calculations of the 2PA cross sections for model chromophores of the photoactive yellow and green fluorescent proteins.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of EPICS based vacuum control system for variable energy cyclotron centre, Kolkata

The vacuum system of the Room Temperature (K = 130) Cyclotron of Variable Energy Cyclotron Centre is comprised of vacuum systems of main machine and Beam Transport System. The vacuum control system is upgraded to a PLC based Automated system from the initial relay based Manual system. The supervisory control of the vacuum system is implemented in Experimental Physics and Industrial Control System (EPICS). An EPICS embedded ARM based vacuum gauge controller is developed to mitigate the requirement of vendor specific gauge controller for gauges and also for seamless integration of the gauge controllers with the control system. A set of MS-Windows ActiveX components with embedded EPICS Channel Access interface are developed to build operator interfaces with less complex programming and to incorporate typical Windows feature, e.g., user authentication, file handling, better fonts, colors, mouse actions etc. into the operator interfaces. The control parameters, monitoring parameters, and system interlocks of the system are archived in MySQL based EPICS MySQL Archiver developed indigenously. In this paper, we describe the architecture, the implementation details, and the performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation multi representation and oral communication skills in Department of Physics Education on Elementary Physics II

The ability of multi representation has been widely studied, but there has been no implementation through a model of learning. This study aimed to determine the ability of the students multi representation, relationships multi representation capabilities and oral communication skills, as well as the application of the relations between the two capabilities through learning model Presentatif Based on Multi representation (PBM) in solving optical geometric (Elementary Physics II). A concurrent mixed methods research methods with qualitative–quantitative weights. Means of collecting data in the form of the pre-test and post-test with essay form, observation sheets oral communication skills, and assessment of learning by observation sheet PBM–learning models all have a high degree of respectively validity category is 3.91; 4.22; 4.13; 3.88. Test reliability with Alpha Cronbach technique, reliability coefficient of 0.494. The students are department of Physics Education Unnes as a research subject. Sequence multi representation tendency of students from high to low in sequence, representation of M, D, G, V; whereas the order of accuracy, the group representation V, D, G, M. Relationship multi representation ability and oral communication skills, comparable/proportional. Implementation conjunction generate grounded theory. This study should be applied to the physics of matter, or any other university for comparison.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and implementation of wireless dose logger network for radiological emergency decision support system

A decision support system (DSS) is implemented in Radiological Safety Division, Indira Gandhi Centre for Atomic Research for providing guidance for emergency decision making in case of an inadvertent nuclear accident. Real time gamma dose rate measurement around the stack is used for estimating the radioactive release rate (source term) by using inverse calculation. Wireless gamma dose logging network is designed, implemented, and installed around the Madras Atomic Power Station reactor stack to continuously acquire the environmental gamma dose rate and the details are presented in the paper. The network uses XBee–Pro wireless modules and PSoC controller for wireless interfacing, and the data are logged at the base station. A LabView based program is developed to receive the data, display it on the Google Map, plot the data over the time scale, and register the data in a file to share with DSS software. The DSS at the base station evaluates the real time source term to assess radiation impact.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a Fe-He Three-body Interatomic Potential

The implementation of a recently-developed interatomic potential describing the interactions of helium in bcc iron is described. This He-Fe potential was based on an empirical fit to the results of ab initio calculations of both the formation and relaxation energies of small helium defect structures in iron. The fitting database included substitutional and interstitial helium, as well as small helium and helium-vacancy clusters. In contrast to previous He-Fe pair potentials, fitting the ab initio forces and energies required the use of a three-body interaction term. The implementation of this potential for atomistic simulations using molecular dynamics presented certain challenges which are discussed here to facilitate its further use in materials research, particularly to investigate the behavior of iron-based alloys that may be employed in fusion energy systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MapReduce Implementation of a Hybrid Spectral Library-Database Search Method for Large-Scale Peptide Identification

A MapReduce-based implementation called MR- MSPolygraph for parallelizing peptide identification from mass spectrometry data is presented. The underlying serial method, MSPolygraph, uses a novel hybrid approach to match an experimental spectrum against a combination of a protein sequence database and a spectral library. Our MapReduce implementation can run on any Hadoop cluster environment. Experimental results demonstrate that, relative to the serial version, MR-MSPolygraph reduces the time to solution from weeks to hours, for processing tens of thousands of experimental spectra. Speedup and other related performance studies are also reported on a 400-core Hadoop cluster using spectral datasets from environmental microbial communities as inputs.

59 BASIC BIOLOGICAL SCIENCES↗

Deterministic implementation of weak quantum cubic nonlinearity

We propose a deterministic implementation of weak cubic nonlinearity, which is a basic building block of a full-scale continuous-variable quantum computation. Our proposal relies on preparation of a specific ancillary state and transferring its nonlinear properties onto the desired target by means of deterministic Gaussian operations and feed forward. We show that, despite the imperfections arising from the deterministic nature of the operation, the weak quantum nonlinearity can be implemented and verified with the current level of technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementing an X-ray validation pipeline for the Protein Data Bank

The implementation of a validation pipeline, based on community recommendations, for future depositions of X-ray crystal structures in the Protein Data Bank is described. There is an increasing realisation that the quality of the biomacromolecular structures deposited in the Protein Data Bank (PDB) archive needs to be assessed critically using established and powerful validation methods. The Worldwide Protein Data Bank (wwPDB) organization has convened several Validation Task Forces (VTFs) to advise on the methods and standards that should be used to validate all of the entries already in the PDB as well as all structures that will be deposited in the future. The recommendations of the X-ray VTF are currently being implemented in a software pipeline. Here, ongoing work on this pipeline is briefly described as well as ways in which validation-related information could be presented to users of structural data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implementing High Performance Remote Method Invocation in CCA

We report our effort in engineering a high performance remote method invocation (RMI) mechanism for the Common Component Architecture (CCA). This mechanism provides a highly efficient and easy-to-use mechanism for distributed computing in CCA, enabling CCA applications to effectively leverage parallel systems to accelerate computations. This work is built on the previous work of Babel RMI. Babel is a high performance language interoperability tool that is used in CCA for scientific application writers to share, reuse, and compose applications from software components written in different programming languages. Babel provides a transparent and flexible RMI framework for distributed computing. However, the existing Babel RMI implementation is built on top of TCP and does not provide the level of performance required to distribute fine-grained tasks. We observed that the main reason the TCP based RMI does not perform well is because it does not utilize the high performance interconnect hardware on a cluster efficiently. We have implemented a high performance RMI protocol, HPCRMI. HPCRMI achieves low latency by building on top of a low-level portable communication library, Aggregated Remote Message Copy Interface (ARMCI), and minimizing communication for each RMI call. Our design allows a RMI operation to be completed by only two RDMA operations. We also aggressively optimize our system to reduce copying. In this paper, we discuss the design and our experimental evaluation of this protocol. Our experimental results show that our protocol can improve RMI performance by an order of magnitude.

99 GENERAL AND MISCELLANEOUS↗

TH-A-16A-01: Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation

The expansion and integration of diagnostic imaging technologies such as On Board Imaging (OBI) and Cone Beam Computed Tomography (CBCT) into radiation oncology has required radiation oncology physicists to be responsible for and become familiar with assessing image quality. Unfortunately many radiation oncology physicists have had little or no training or experience in measuring and assessing image quality. Many physicists have turned to automated QA analysis software without having a fundamental understanding of image quality measures. This session will review the basic image quality measures of imaging technologies used in the radiation oncology clinic, such as low contrast resolution, high contrast resolution, uniformity, noise, and contrast scale, and how to measure and assess them in a meaningful way. Additionally a discussion of the implementation of an image quality assurance program in compliance with Task Group recommendations will be presented along with the advantages and disadvantages of automated analysis methods. Learning Objectives: Review and understanding of the fundamentals of image quality. Review and understanding of the basic image quality measures of imaging modalities used in the radiation oncology clinic. Understand how to implement an image quality assurance program and to assess basic image quality measures in a meaningful way.

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 36: Implementation of constant dose rate and gantry speed arc therapy(CDR-CAS-IMAT) for thoracic esophageal carcinoma on Varian 23EX

Objective: The purpose of this study is to propose an alternative planning approach for VMAT using constant dose rate and gantry speed arc therapy(CDR-CAS-IMAT) implementation on conventional Linac Varian 23EX and used IMRT as a benchmark to evaluate the performance. Methods and materials: Eighteen patients with thoracic esophageal carcinoma who were previously treated with IMRT on Varian 23EX were retrospectively planned for CDR-CAS-IMAT plans. Dose prescription was set to 60 Gy to PTVs in 30 fractions. The planning objectives for PTVs and OAR were corresponding with the IMRT plans. Dose to the PTVs and OAR were compared to IMRT with respect to plan quality, MU, treatment time and delivery accuracy. Results: CDR-CAS-IMAT plans led to equivalent or superior plan quality as compared to IMRT, PTV's CI relative increased 16.2%, while small deviations were observed on minimum dose for PTV. Volumes in the cord receiving 40Gy were increased from 3.6% with IMRT to 7.0%. Treatment times were reduced significantly with CDR-CAS-IMAT(mean 85.7s vs. 232.1s, p < .05), however, MU increased by a factor of 1.3 and lung V10/5/3.5/aver were relative increase 6.7%,12%,17.9%,4.2%, respectively. And increased the E-P low dose area volume decreased the hight dose area. There were no significant difference in Delta4 measurements results between both planning techniques. Conclusion: CDR-CAS-IMAT plans can be implemented smoothly and quickly into a busy cancer center, which improved PTV CI and reduces treatment time but increased the MU and low dose irradiated area. An evaluation of weight loss must be performed during treatment for CDR-CAS-IMAT patients.

60 APPLIED LIFE SCIENCES↗

SU-F-T-248: FMEA Risk Analysis Implementation (AAPM TG-100) in Total Skin Electron Irradiation Technique

Purpose: Total Skin Electron Irradiation (TSEI) is a radiotherapy treatment which involves irradiating the entire body surface as homogeneously as possible. It is composed of an extensive multi-step technique in which quality management requires high consumption of resources and a fluid communication between the involved staff, necessary to improve the safety of treatment. The TG-100 proposes a new perspective of quality management in radiotherapy, presenting a systematic method of risk analysis throughout the global flow of the stages through the patient. The purpose of this work has been to apply TG-100 approach to the TSEI procedure in our institution. Methods: A multidisciplinary team specifically targeting TSEI procedure was formed, that met regularly and jointly developed the process map (PM), following TG-100 guidelines of the AAPM. This PM is a visual representation of the temporal flow of steps through the patient since start until the end of his stay in the radiotherapy service. Results: This is the first stage of the full risk analysis, which is being carried out in the center. The PM provides an overview of the process and facilitates the understanding of the team members who will participate in the subsequent analysis. Currently, the team is implementing the analysis of failure modes and effects (FMEA). The failure modes of each of the steps have been identified and assessors are assigning a value of severity (S), frequency of occurrence (O) and lack of detection (D) individually. To our knowledge, this is the first PM made for the TSEI. The developed PM can be useful for those centers that intend to implement the TSEI technique. Conclusion: The PM of TSEI technique has been established, as the first stage of full risk analysis, performed in a reference center in this treatment.

60 APPLIED LIFE SCIENCES↗

TH-AB-202-12: The First Clinical Implementation of a Real-Time Six Degree of Freedom Tracking System During Radiation Therapy

Purpose: In current practice, imaging is typically performed prior to treatment; the cancer target motion during treatment is unknown. We present the first clinical implementation of real time Kilovoltage Intrafraction Monitoring (KIM) system which tracks the cancer target translational and rotational motions during treatment. Methods: KIM technology: KIM estimates the 3D position of the target tumour based on segmented 2D positions of the three implanted fiducials in each of the kV images (125 kV, 10 mA at 11 fps) taken continuously during the treatment arc. The 2D-3D target estimation is based on a probability distribution function, obtained during pre-treatment CBCT. Rotations about each axis with the centroid of the markers as the pivot were calculated using the iterative closest point algorithm in real time. Patient: A patient with prostate adenocarcinoma undergoing stereotactic body radiotherapy (SBRT) with 36.25 Gy delivered in 5 fractions (Varian TrueBeam, 6X, VMAT) was enrolled in the study. The trial complies with Australian ethical and regulatory standards. Results: Of the 5 fractions of treatment the patient received, KIM was utilised successfully in 4 fractions with 3 couch shifts due to large persistent prostate movements (>2mm for more than 5 seconds). KIM translational accuracy and precision in comparison with post treatment kV-MV triangulation are 0.28±0.59 mm, −0.19±0.25 mm and 0.23±0.69 mm in the Left-Right, Superior-Inferior and Anterior-Posterior directions, respectively. KIM rotational accuracy as compared with triangulation is: 0.429°±2.22°, −0.44°±4.7° and 0.06°±1.08° in the roll, pitch and yaw direction, respectively. Conclusion: The first six degree of freedom KIM system was successfully implemented clinically. The presented KIM system has sub-millimeters accuracy and precision in all three translational axes, and less than 1° of mean error in all three rotational axes. Acknowledgement: This work is supported by Cancer Australia grants APPXXX, APPYYY.