Search NASA⌕ Search

SEARCH · Search NASA

Results for “Kernel methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Spectrotemporal CT data acquisition and reconstruction at low dose

Purpose: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D + dual energy + time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. Methods: The authors approach the 5D reconstruction problem within the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.

60 APPLIED LIFE SCIENCES↗

SU-E-T-299: Small Fields Profiles Correction Through Detectors Spatial Response Functions and Field Size Dependence Analysis

Purpose: To calculate the spatial response function of various radiation detectors, to evaluate the dependence on the field size and to analyze the small fields profiles corrections by deconvolution techniques. Methods: Crossline profiles were measured on a Novalis Tx 6MV beam with a HDMLC. The configuration setup was SSD=100cm and depth=5cm. Five fields were studied (200×200mm2,100×100mm2, 20×20mm2, 10×10mm2and 5×5mm2) and measured were made with passive detectors (EBT3 radiochromic films and TLD700 thermoluminescent detectors), ionization chambers (PTW30013, PTW31003, CC04 and PTW31016) and diodes (PTW60012 and IBA SFD). The results of passive detectors were adopted as the actual beam profile. To calculate the detectors kernels, modeled by Gaussian functions, an iterative process based on a least squares criterion was used. The deconvolutions of the measured profiles were calculated with the Richardson-Lucy method. Results: The profiles of the passive detectors corresponded with a difference in the penumbra less than 0.1mm. Both diodes resolve the profiles with an overestimation of the penumbra smaller than 0.2mm. For the other detectors, response functions were calculated and resulted in Gaussian functions with a standard deviation approximate to the radius of the detector in study (with a variation less than 3%). The corrected profiles resolve the penumbra with less than 1% error. Major discrepancies were observed for cases in extreme conditions (PTW31003 and 5×5mm2 field size). Conclusion: This work concludes that the response function of a radiation detector is independent on the field size, even for small radiation beams. The profiles correction, using deconvolution techniques and response functions of standard deviation equal to the radius of the detector, gives penumbra values with less than 1% difference to the real profile. The implementation of this technique allows estimating the real profile, freeing from the effects of the detector used for the acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inverse Mapping of the Collision Kernel and Wall Flux Scaling in a Tall Convection‐Cloud Chamber Using Local Sensors and Knowledge‐Informed Deep Learning

Droplet collision–coalescence is a crucial process in cloud physics, but accurately representing this process under different dynamical conditions remains challenging. A proposed future convective‐cloud chamber aims to investigate this key process, but the method for observing it remains unclear, even though it is theoretically established that collision‐coalescence will occur. This study serves as a proof‐of‐concept demonstration of how knowledge‐informed deep learning, combined with measurement data from local sensors in the chamber, can be used to estimate the collision kernels, which determine how the droplet size distribution evolves during collision‐coalescence. In addition to estimating the collision kernel, we also address wall fluxes, another uncertain but important process that acts as a source of heat and moisture in the chamber. Ensemble runs of large‐eddy simulations are conducted by scaling the wall fluxes and the collision kernel, while the measured flow and cloud properties are used as inputs for a neural network. Results indicate that this approach successfully maps the scaling of wall fluxes and the collision kernel with biases of approximately 1% or less relative to the range of the target data. This proof‐of‐concept lays the groundwork for future applications; when the real measurements are available, real sensor data combined with the trained model presented in this work will enable estimation of the actual wall fluxes and collision kernel.

cloud chamber↗

SU-E-T-456: Development of An EPID-Based Output Measurement and Dosimetric Verification Tool for Electron Beam Therapy

Purpose: To develop an efficient and robust method for output and absolute dosimetric measurements of electron beam therapy by using a high spatialresolution and high frame-rate amorphous silicon flat-panel electronic portal imaging device (EPID). Methods: A previously-established EPID dosimetry system was extended to measure the output factors of electron beams of various sizes and their planar dose distributions at reference depths. Specific EPID responses to different electron energies were derived from Monte Carlo (MC) simulations to de-convolve the EPID raw images to the incident electron fluence map. To reconstruct the 2D water-based dose distribution map at reference depths for different energies, the fluence map was further convolved with a MC simulated pencil beam kernel. Different energies of 6, 9, 12, 16, and 20 MeV from a Varian C-series linac were tested. Standard square fields ranging from 2×2 to 15×15 cm{sup 2} were measured and validated against film/ion chamber measurements. Small fields of different patient cases with irregular cutout shapes were also tested. Results: The EPIDmeasured output factors for 2×2, 3×3, 6×6, and 10×10 cm{sup 2} fields with all electron energies agree with the film/ion chamber data within 2.7%. The average discrepancy between EPID and film/ion chamber measurements was 1.4%. The differences for the three patient cases were 0.1%, 2.1%, and 1.6%. Deliveries with different monitor units were tested and the results exhibited good linearity. Measurements with different dose rate showed that the dose rate dependence was less than 1%. Using the proposed method, 2D absolute dose maps were created from the EPID raw images and the results were consistent with film measurements. Conclusion: The efficient data readout and portability of the newly developed EPID system provides an efficient and accurate solution for electron beam therapy. It addresses an important unmet clinical need for a fast and reliable small field output factor measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Data‐driven variational method for discrepancy modeling: Dynamics with small‐strain nonlinear elasticity and viscoelasticity

Abstract The effective inclusion of a priori knowledge when embedding known data in physics‐based models of dynamical systems can ensure that the reconstructed model respects physical principles, while simultaneously improving the accuracy of the solution in the previously unseen regions of state space. This paper presents a physics‐constrained data‐driven discrepancy modeling method that variationally embeds known data in the modeling framework. The hierarchical structure of the method yields fine scale variational equations that facilitate the derivation of residuals which are comprised of the first‐principles theory and sensor‐based data from the dynamical system. The embedding of the sensor data via residual terms leads to discrepancy‐informed closure models that yield a method which is driven not only by boundary and initial conditions, but also by measurements that are taken at only a few observation points in the target system. Specifically, the data‐embedding term serves as residual‐based least‐squares loss function, thus retaining variational consistency. Another important relation arises from the interpretation of the stabilization tensor as a kernel function, thereby incorporating a priori knowledge of the problem and adding computational intelligence to the modeling framework. Numerical test cases show that when known data is taken into account, the data driven variational (DDV) method can correctly predict the system response in the presence of several types of discrepancies. Specifically, the damped solution and correct energy time histories are recovered by including known data in the undamped situation. Morlet wavelet analyses reveal that the surrogate problem with embedded data recovers the fundamental frequency band of the target system. The enhanced stability and accuracy of the DDV method is manifested via reconstructed displacement and velocity fields that yield time histories of strain and kinetic energies which match the target systems. The proposed DDV method also serves as a procedure for restoring eigenvalues and eigenvectors of a deficient dynamical system when known data is taken into account, as shown in the numerical test cases presented here.

Masud, Arif↗

Scale-dependent galaxy bias, CMB lensing-galaxy cross-correlation, and neutrino masses

One of the most powerful cosmological datasets when it comes to constraining neutrino masses is represented by galaxy power spectrum measurements, P gg ($k$). The constraining power of P gg ($k$) is however severely limited by uncertainties in the modeling of the scale-dependent galaxy bias b($k$). In this work we present a new proof-of-principle for a method to constrain b($k$) by using the cross-correlation between the Cosmic Microwave Background (CMB) lensing signal and galaxy maps (C$Kg\atop{l}$) using a simple but theoretically well-motivated parametrization for b($k$). We apply the method using C$Kg\atop{l}$ measured by cross-correlating Planck lensing maps and the Baryon Oscillation Spectroscopic Survey (BOSS) Data Release 11 (DR11) CMASS galaxy sample, and P gg ($k$) measured from the BOSS DR12 CMASS sample. We detect a non-zero scale-dependence at moderate significance, which suggests that a proper modeling of b($k$) is necessary in order to reduce the impact of non-linearities and minimize the corresponding systematics. The accomplished increase in constraining power of P gg ($k$) is demonstrated by determining a 95% confidence level upper bound on the sum of the three active neutrino masses M $v$ of M $v$ < 0:19 eV. This limit represents a significant improvement over previous bounds with comparable datasets. Our method will prove especially powerful and important as future large-scale structure surveys will overlap more significantly with the CMB lensing kernel providing a large cross-correlation signal.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-EF-303-04: An Advanced Image Processing Method to Improve the Spatial Resolution of Proton Radiographies

Purpose: We present an optimization method to improve the spatial resolution and the water equivalent thickness accuracy of proton radiographies. Methods: The method is designed for imaging systems measuring only the residual range of protons without relying on tracker detectors to determine the beam trajectory before and after the target. Specifically, the method was used for an imaging set-up consisting of a stack of 61 parallel-plate ionization chambers (PPIC) working as a range telescope. The method uses a decomposition approach of the residual range signal measured by the PPIC and constructs subimages with small size pixels geometrically rearranged and appropriately averaged to be merged into a final single radiography. The method was tested using Monte Carlo simulated and experimental proton radiographies of a PMMA step phantom and an anthropomorphic head phantom. Results: For the step phantom, the effective spatial resolution was found to be 4 and 3 times higher than the nominal resolution for the simulated and experimental radiographies, respectively. For the head phantom, a gamma index was calculated to quantify the conformity of the simulated proton radiographies with a digitally reconstructed X-ray radiography convolved with a Gaussian kernel equal to the proton beam spot-size. For DTA=2.5 mm and RD=2.5%, the passing ratio was 100%/85% for the optimized/non-optimized case, respectively. An extension of the method allows reducing the dose given to the patient during radiography acquisition. We show that despite a dose reduction of 25 times (leading to a dose of 0.016 mGy for the current imaging set-up), the image quality of the optimized radiographies remains fairly unaffected for both the simulated and experimental results. Conclusion: The optimization method leads to a significant increase of the spatial resolution allowing recovering image details that are unresolved in non-optimized radiographies. These results represent a major step towards clinical application of proton radiography.

60 APPLIED LIFE SCIENCES↗

Carbothermic Synthesis of 820 m UN Kernels: Literature Review, Thermodynamics, Analysis, and Related Experiments

The U.S. Department of Energy is considering a new nuclear fuel that would be less susceptible to ruptures during a loss-of-coolant accident. The fuel would consist of tristructural isotropic coated particles with large, dense uranium nitride (UN) kernels. This effort explores many factors involved in using gel-derived uranium oxide-carbon microspheres to make large UN kernels. Analysis of recent studies with sufficient experimental details is provided. Extensive thermodynamic calculations are used to predict carbon monoxide and other pressures for several different reactions that may be involved in conversion of uranium oxides and carbides to UN. Experimentally, the method for making the gel-derived microspheres is described. These were used in a microbalance with an attached mass spectrometer to determine details of carbothermic conversion in argon, nitrogen, or vacuum. A quantitative model is derived from experiments for vacuum conversion to an uranium oxide-carbide kernel.

carothermic↗

Python for Development of OpenMP and CUDA Kernels for Multidimensional Data

Design of data structures for high performance computing (HPC) is one of the principal challenges facing researchers looking to utilize heterogeneous computing machinery. Heterogeneous systems derive cost, power, and speed efficiency by being composed of the appropriate hardware for the task. Yet, each type of processor requires a specific organization of the application state in order to achieve peak performance. Discovering this and refactoring the code can be a challenging and time-consuming task for the researcher, as the data structures and the computational model must be co-designed. We present a methodology that uses Python as the environment for which to explore tradeoffs in both the data structure design as well as the code executing on the computation accelerator. Our method enables multi-dimensional arrays to be used effectively in any target environment. We have chosen to focus on OpenMP and CUDA environments, thus exploring the development of optimized kernels for the two most common classes of computing hardware available today: multi-core CPU and GPU. Python s large palette of file and network access routines, its associative indexing syntax and support for common HPC environments makes it relevant for diverse hardware ranging from laptops through computing clusters to the highest performance supercomputers. Our work enables researchers to accelerate the development of their codes on the computing hardware of their choice.

43 PARTICLE ACCELERATORS↗

Monte Carlo mesh tallies based on a Kernel Density Estimator approach using integrated particle tracks

A new Monte Carlo mesh tally based on a Kernel Density Estimator (KDE) approach using integrated particle tracks is presented. We first derive the KDE integral-track estimator and present a brief overview of its implementation as an alternative to the MCNP fmesh tally. To facilitate a valid quantitative comparison between these two tallies for verification purposes, there are two key issues that must be addressed. The first of these issues involves selecting a good data transfer method to convert the nodal-based KDE results into their cell-averaged equivalents (or vice versa with the cell-averaged MCNP results). The second involves choosing an appropriate resolution of the mesh, since if it is too coarse this can introduce significant errors into the reference MCNP solution. After discussing both of these issues in some detail, we present the results of a convergence analysis that shows the KDE integral-track and MCNP fmesh tallies are indeed capable of producing equivalent results for some simple 3D transport problems. In all cases considered, there was clear convergence from the KDE results to the reference MCNP results as the number of particle histories was increased. (authors)

97 MATHEMATICS AND COMPUTING↗

Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images

Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5°/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (−15.50 ± 5.59)% to (−2.12 ± 1.05)% and (−7.28 ± 2.30)% to (−0.23 ± 0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

60 APPLIED LIFE SCIENCES↗

Efficient 3-D velocity model building using joint inline and crossline plane-wave wave-equation migration velocity analyses

SUMMARY Wave-equation migration velocity analysis (WEMVA) is an image-domain inversion method for velocity model building. Automatic plane-wave WEMVA (PWEMVA) calculates the moveouts of plane-wave common-image gathers (CIGs) by searching a best-fitting parabola with semblance analysis and backprojects residual CIG moveouts into wavefield wave paths with a reflection tomographic kernel. However, 3-D PWEMVA is very computationally expensive because 3-D reflection tomographic inversion requires at least five 3-D reverse-time migrations per iteration and stores two types of source wavefields at model boundaries. We develop a joint inline and crossline PWEMVA method for efficient 3-D velocity model building. We alternatively implement the inline and crossline PWEMVAs with a constraint for each other, in which we iteratively construct the 3-D velocity model update through 1-D spline interpolation of 2-D gradients. The inline and crossline joint inversion is practical since PWEMVA only inverts for low-wavenumber velocity perturbations along wave paths, and the method can take less than 1 per cent of the computational cost of full 3-D PWEMVA. To construct unaliased plane waves for our joint inline and crossline PWEMVA, we develop a 3-D data interpolation method in the frequency–wavenumber (FK) domain to recover regularly and randomly missing traces. The method minimizes the misfit on sufficiently localized data subsets with iterative optimal step lengths and a gradient preconditioner that iteratively selects dominant dips along different azimuths. In numerical experiments, we use a 3-D synthetic seismic data set and a land 3-D field seismic data set acquired at the Farnsworth CO2-EOR (enhanced oil recovery) field to demonstrate the efficacy of our velocity model building and data interpolation methods.

Liu, Xuejian↗

Data-Efficient Strategies for Probabilistic Voltage Envelopes under Network Contingencies

This work presents an efficient data-driven method to construct probabilistic voltage envelopes (PVE) using power flow learning in grids with network contingencies. First, a network-aware Gaussian process (GP) termed Vertex-Degree Kernel (VDK-GP), developed in prior work, is used to estimate voltage–power functions for a few network configurations. The paper introduces a novel multi-task vertex degree kernel (MT-VDK) that amalgamates the learned VDK-GPs to determine power flows for unseen networks, with a significant reduction in the computational complexity and hyperparameter requirements compared to alternate approaches. Simulations on the IEEE 30-Bus network demonstrate the retention and transfer of power flow knowledge in both N-1 and N-2 contingency scenarios. The MT-VDK-GP approach achieves over 50 % reduction in mean prediction error for novel N-1 contingency network configurations in low training data regimes (50–250 samples) over VDK-GP. Additionally, MT-VDK-GP outperforms a hyper-parameter based transfer learning approach in over 75 % of N-2 contingency network structures, even without historical N-2 outage data. Furthermore, the proposed method demonstrates the ability to achieve PVEs using sixteen times fewer power flow solutions compared to Monte-Carlo sampling-based methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulating Hydrodynamics in Cosmology with CRK-HACC

Abstract We introduce CRK-HACC, an extension of the Hardware/Hybrid Accelerated Cosmology Code (HACC), to resolve gas hydrodynamics in large-scale structure formation simulations of the universe. The new framework couples the HACC gravitational N -body solver with a modern smoothed-particle hydrodynamics (SPH) approach called conservative reproducing kernel SPH (CRKSPH). CRKSPH utilizes smoothing functions that exactly interpolate linear fields while manifestly preserving conservation laws (momentum, mass, and energy). The CRKSPH method has been incorporated to accurately model baryonic effects in cosmology simulations—an important addition targeting the generation of precise synthetic sky predictions for upcoming observational surveys. CRK-HACC inherits the codesign strategies of the HACC solver and is built to run on modern GPU-accelerated supercomputers. In this work, we summarize the primary solver components and present a number of standard validation tests to demonstrate code accuracy, including idealized hydrodynamic and cosmological setups, as well as self-similarity measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Semi-classical Kinetic Theory for Massive Spin-half Fermions with Leading-order Spin Effects

We consider the quantum kinetic-theory description for interacting massive spin-half fermions using the Wigner function formalism. We derive a general kinetic theory description assuming that the spin effects appear at the classical and quantum level. To track the effect of such different contributions we use the semi-classical expansion method to obtain the generalized dynamical equations including spin, analogous to classical Boltzmann equation. This approach can be used to obtain a collision kernel involving local as well as non-local collisions among the microscopic constituent of the system and eventually, a framework of spin hydrodynamics ensuring the conservation of the energy-momentum tensor and total angular momentum tensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Bayesian Learning Approach to Wireless Outdoor Heatmap Construction using Deep Gaussian Process

We present a novel Bayesian learning approach to outdoor radio heatmap construction utilizing deep Gaussian process (GP). The proposed approach employs a two-layer hierarchy which consists of two cascaded Gaussian processes that are capable of modeling more complex input-output relations than standard single-layer Gaussian processes. Since deriving the exact model likelihood is challenging, a lower bound is optimized instead so that gradient descent-based methods can be performed to find out the optimal model parameters. Typically, inducing points are used in GPs to facilitate low-rank approximation of covariance (kernel) matrices for computation speedup. However, the inaccuracy induced by inducing points can accumulate when stacking multiple layers of GP which may hinder the performance of deep GP. Moreover, since inducing points need to be learned, having them at all layers of deep GP also incurs computational burden. To overcome the above challenges, in contrast to the canonical deep GP model, we use a modified architecture where a full standard GP resides in the first layer and inducing points are only introduced for the second layer. This modified architecture strikes a balance between model accuracy and training complexity. In the proposed model, the noise parameter of the first GP layer is also eliminated to improve the training efficiency as the noise parameter at the output of the second layer suffices to model the uncertainty in the output. The proposed approach is evaluated on real-world datasets, in the form of location-Received Signal Strength (RSS) pairs, collected from the Platform for Open Wireless Data-driven Experimental Research (POWDER) located at the campus of the University of Utah. Experiment results show that the proposed approach can achieve smaller prediction errors on various training and testing data configurations than DNN-based and GP-based methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward a better thermal scattering law of (C 5 O 2 H 8 ) n : Inelastic neutron scattering and oClimax + NJOY2016

With the advancements in technology (both experimental and computational) the determination of the“true” experimental phonon spectrum became more accessible. Here a methodology for producing thermal scattering libraries from the experimental data (namely the DFT+oClimax method) for lucite (C 5 O 2 H 8 ) n is discussed. Double differential scattering cross section (DDSCS) experiments were performed at the Spallation Neutron Source of Oak Ridge National Laboratory (SNS ORNL). Novel scattering kernel evaluations, based on the phonon spectrum for (C 5 O 2 H 8 ) n ,were created using oClimax and NJOY2016 codes. In order to compare and asses the performance of the newly created library, the experimental setup was simulated using MCNP6.1. Compared to the current ENDF/B-VIII.0, the resulting RPI (C 5 O 2 H 8 ) n library improved the calculation of both double differential scattering and total scattering cross sections. A set of criticality benchmarks containing (C 5 O 2 H 8 ) n from HEU-MET-THERM resulted in an overall improved calculation of K eƒƒ . The DFT + oClimax method is shown to be the most comprehensive method for analysis of moderator materials, due to the fact that it can be verified against all data measured at VISION, ARCS and SEQUOIA neutron spectrometers at SNS ORNL, and experimental total scattering cross section measurements. This technique also provides a new technique for calculating any phonon spectrum-related quantities such as scattering law kernel, specific heat capacity, thermal conductivity, etc. for any solid state material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗