Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leak Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Autonomous Cryogenic Leak Detector for Improving Launch Site Operations

NASA, military, and commercial satellite users need launch services that are highly reliable, less complex, easier to test, and cost effective. This project has developed a tapered optical fiber sensor for detecting hydrogen. The invention involves incorporating chemical indicators on the tapered end of an optical fiber using organically modified silicate nanomaterials. The Hazardous Gas Detection Lab (HGDL) at Kennedy Space Center is involved in the design and development of instrumentation that can detect and qualify various mission-critical chemicals. Historically, hydrogen, helium, nitrogen, oxygen, and argon are the first five gases of HGDL focus. The use of these cryogenic fluids in the area of propulsion offers challenges. Due to their extreme low temperatures, these fluids induce contraction of the materials they contact, a potential cause of leakage. Among them, hydrogen is of particular concern. Small sensors are needed in multiple locations without adding to the structural weight. The most vulnerable parts of the engine are the connection flanges on the transfer lines, which have to support cycles of large thermal amplitude. The thermal protection of the engine provides a closed area, increasing the likelihood of an explosive atmosphere. Thus, even a small leak represents an unacceptable hazardous condition during loading operations, in flight, or after an aborted launch. Tapered fibers were first fabricated from 1/1.3-mm core/cladding (silica/ plastic) optical fibers. Typically a 1-ft (approx. 30- cm) section of the 1-mm fiber is cut from the bundle and marked with a pen into five 2-.-in. (.5.7-cm) sections. A propane torch is applied at every alternate mark to burn the jacket and soften the glass core. While the core is softening, the two ends of the fiber are pulled apart slowly to create fine tapers of .- to .-in. (.6- to 12-mm) long on the 1-mm optical fiber. Following this, the non-tapered ends of the fibers are polished to a 0.3-micron finish. Then these fibers were coated with indicators sensitive to hydrogen. The tapered hydrogen detection system with its unique flexibility is the only system that can be placed in many locations inside the vehicles and detect the exact location of leaks, saving millions of dollars for launch vehicle industries.

Goswami, Kisholoy↗

Propellant Feed System Leak Detection: Lessons Learned From the Linear Aerospike SR-71 Experiment (LASRE)

This paper presents pertinent results and assessment of propellant feed system leak detection as applied to the Linear Aerospike SR-71 Experiment (LASRE) program flown at the NASA Dryden Flight Research Center, Edwards, California. The LASRE was a flight test of an aerospike rocket engine using liquid oxygen and high-pressure gaseous hydrogen as propellants. The flight safety of the crew and the experiment demanded proven technologies and techniques that could detect leaks and assess the integrity of hazardous propellant feed systems. Point source detection and systematic detection were used. Point source detection was adequate for catching gross leakage from components of the propellant feed systems, but insufficient for clearing LASRE to levels of acceptability. Systematic detection, which used high-resolution instrumentation to evaluate the health of the system within a closed volume, provided a better means for assessing leak hazards. Oxygen sensors detected a leak rate of approximately 0.04 cubic inches per second of liquid oxygen. Pressure sensor data revealed speculated cryogenic boiloff through the fittings of the oxygen system, but location of the source(s) was indeterminable. Ultimately, LASRE was cancelled because leak detection techniques were unable to verify that oxygen levels could be maintained below flammability limits.

Hass, Neal↗

TEV-3349 "ATF-2 2A Loop Pin Cladding Requirements"

Industry partners, including Westinghouse, Framatome, General Electric, General Atomics, Toshiba, etc. require requirements for fuel pins they insert in the reactor for testing. This document contains those requirements. These requirements represent an agreement between ATR and NS&T, and include the requirements for pins fabricated at the INL. These include inspections such as radiography, helium leak check, etc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of materials from MSFC LDEF experiments

In preparation for the arrival of the Long Duration Exposure Facility (LDEF) samples, a material testing and handling approach was developed for the evaluation of the materials. A configured lab was made ready for the de-integration of the LDEF experiments. The lab was prepared to clean room specifications and arranged with the appropriate clean benches, tables, lab benches, clean room tools, particulate counter, and calibrated and characterized analytical instrumentation. Clean room procedures were followed. Clean room attire and shoe cleaning equipment were selected and installed for those entering. Upon arrival of the shipping crates they were taken to the lab, logged in, and opened for examination. The sample trays were then opened for inspection and test measurements. The control sample measurements were made prior to placement into handling and transport containers for the flight sample measurements and analysis. Both LDEF flight samples and LDEF type materials were analyzed and tested for future flight candidate material evaluation. Both existing and newly purchased equipment was used for the testing and evaluation. Existing Space Simulation Systems had to be upgraded to incorporate revised test objectives and approaches. Fixtures such as special configured sample holders, water, power and LN2 feed-throughs, temperature measurement and control, front surface mirrors for reflectance and deposition, and UV grade windows had to be designed, fabricated, and installed into systems to achieve the revised requirements. New equipment purchased for LDEF analysis was incorporated into and/or used with existing components and systems. A partial list of this equipment includes a portable monochromator, enhanced UV System, portable helium leak detector for porosity and leak measurements, new turbo pumping system, vacuum coaster assembly, cryopumps, and analytical and data acquisition equipment. A list of materials tested, equipment designed, fabricated and installed, systems used, and analytical research accomplished on both LDEF flight samples and on similar materials which were lab tested for a comparative analysis to the LDEF flight samples is presented.

Johnson, R. Barry↗

Development of a ROV Deployed Video Analysis Tool for Rapid Measurement of Submerged Oil/Gas Leaks

Expanded deep sea drilling around the globe makes it necessary to have readily available tools to quickly and accurately measure discharge rates from accidental submerged oil/gas leak jets for the first responders to deploy adequate resources for containment. We have developed and tested a field deployable video analysis software package which is able to provide in the field sufficiently accurate flow rate estimates for initial responders in accidental oil discharges in submarine operations. The essence of our approach is based on tracking coherent features at the interface in the near field of immiscible turbulent jets. The software package, UCB_Plume, is ready to be used by the first responders for field implementation. We have tested the tool on submerged water and oil jets which are made visible using fluorescent dyes. We have been able to estimate the discharge rate within 20% accuracy. A high end WINDOWS laptop computer is suggested as the operating platform and a USB connected high speed, high resolution monochrome camera as the imaging device are sufficient for acquiring flow images under continuous unidirectional illumination and running the software in the field. Results are obtained over a matter of minutes.

02 PETROLEUM↗

He-Ne and CW CO2 laser long-path systems for gas detection

This paper describes the design and testing of a laboratory prototype dual He-Ne laser system for the detection of methane leaks from underground pipelines and solid-waste landfill sites using differential absorption of radiation backscattered from topographic targets. A laboratory-prototype dual CW carbon dioxide laser system also using topographic backscatter is discussed, and measurement results for methanol are given. With both systems, it was observed that the time-varying differential absorption signal was useful in indicating the presence of a gas coming from a nearby source. Limitations to measurement sensitivity, especially the role of speckle and atmospheric turbulence, are described. The speckle results for hard targets are contrasted with those from atmospheric aerosols. The appendix gives appropriate laser lines and values of absorption coefficients for the hydrazine fuel gases.

Grant, W. B.↗

Improved Vacuum-Tight Connector

Simple reinforcing tube increases service life and improves seal. Short stainless-steel tube inserted in copper tube to reinforce against compression, preventing leaks due to thermal distortion or to collapse under squeeze of ferrule in compressure fitting. Several test specimens of improved connector constructed, tested, and evaluated. Fittings not only operated successfully at required operating conditions of vacuum and temperature but also consistently demonstrated high reliability after loosened and tightened many times.

Rudin, Frank↗

An experimental study on the static and dynamic characteristics of pump annular seals with two phase flow

A new test apparatus is reconstructed and is applied to investigate static and dynamic characteristics of annular seals leaked by two phase flow (gas and liquid) for turbopumps. The fluid forces acting on the seals are measured for various parameters such as void ratio, the preswirl velocity, the pressure difference between the inlet and outlet of the seal, the whirling amplitude, and the ratio of whirling speed to spinning speed of the rotor. Influence of these parameters on the static and dynamic characteristics is investigated from the experimental results. As a result, with regard to the two phase flow, as the void ratio increases, the flow induced force decreases. Another dynamic characteristic of two phase flow is as almost similar as that of the monophase flow.

Iwatsubo, T.↗

Use of Raman Spectroscopy and Delta Volume Growth from Void Collapse to Assess Overwrap Stress Gradients Compromising the Reliability of Large Kevlar/Epoxy COPVs

Composite Overwrapped Pressure Vessels (COPVs) are frequently used for storing pressurized gases aboard spacecraft and aircraft when weight saving is desirable compared to all-metal versions. Failure mechanisms in fibrous COPVs and variability in lifetime can be very different from their metallic counterparts; in the former, catastrophic stress-rupture can occur with virtually no warning, whereas in latter, a leak before burst design philosophy can be implemented. Qualification and certification typically requires only one burst test on a production sample (possibly after several pressure cycles) and the vessel need only meet a design burst strength (the maximum operating pressure divided by a knockdown factor). Typically there is no requirement to assess variability in burst strength or lifetime, much less determine production and materials processing parameters important to control of such variability. Characterizing such variability and its source is crucial to models for calculating required reliability over a given lifetime (e.g. R = 0.9999 for 15 years). In this paper we present a case study of how lack of control of certain process parameters in COPV manufacturing can result in variations among vessels and between production runs that can greatly increase uncertainty and reduce reliability. The vessels considered are 40-inch ( NASA Glenn Research center, Cleveland, OH, 44135 29,500 in3 ) spherical COPVs with a 0.74 in. thick Kevlar49/epoxy overwrap and with a titanium liner of which 34 were originally produced. Two burst tests were eventually performed that unexpectedly differed by almost 5%, and were 10% lower than anticipated from burst tests on 26-inch sister vessels similar in every detail. A major observation from measurements made during proof testing (autofrettage) of the 40-inch vessels was that permanent volume growth from liner yielding varied by a factor of more than two (150 in3 to 360 in3 ), which suggests large differences in the residual stress gradient through their overwraps. This resulted in large uncertainty in true fiber stress ratio (fiber stress at operating pressure divided by fiber stress at burst) which governs lifetime. The vessels were originally designed with tight safety margins, so it became crucial to develop a non-destructive evaluation (NDE) technique to directly measure the overwrap residual stress state of each vessel, and to identify those vessels at highest risk of having poor reliability. This paper describes a Raman Spectroscopy technique for measuring certain patterns of fluctuation in fiber elastic strains over the outside vessel surface (where all but one wrap is exposed at certain locations) that are shown to directly correlate to increased fiber stress ratios and reduced reliability.

Kezirian, Michael T.↗

Helium-Cooled Black Shroud for Subscale Cryogenic Testing

This shroud provides a deep-space simulating environment for testing scaled-down models of passively cooling systems for spaceflight optics and instruments. It is used inside a liquid-nitrogen- cooled vacuum chamber, and it is cooled by liquid helium to 5 K. It has an inside geometry of approximately 1.6 m diameter by 0.45 m tall. The inside surfaces of its top and sidewalls have a thermal absorptivity greater than 0.96. The bottom wall has a large central opening that is easily customized to allow a specific test item to extend through it. This enables testing of scale models of realistic passive cooling configurations that feature a very large temperature drop between the deepspace-facing cooled side and the Sun/Earth-facing warm side. This shroud has an innovative thermal closeout of the bottom wall, so that a test sample can have a hot (room temperature) side outside of the shroud, and a cold side inside the shroud. The combination of this closeout and the very black walls keeps radiated heat from the sample s warm end from entering the shroud, reflecting off the walls and heating the sample s cold end. The shroud includes 12 vertical rectangular sheet-copper side panels that are oriented in a circular pattern. Using tabs bent off from their edges, these side panels are bolted to each other and to a steel support ring on which they rest. The removable shroud top is a large copper sheet that rests on, and is bolted to, the support ring when the shroud is closed. The support ring stands on four fiberglass tube legs, which isolate it thermally from the vacuum chamber bottom. The insides of the cooper top and side panels are completely covered with 25- mm-thick aluminum honeycomb panels. This honeycomb is painted black before it is epoxied to the copper surfaces. A spiral-shaped copper tube, clamped at many different locations to the outside of the top copper plate, serves as part of the liquid helium cooling loop. Another copper tube, plumbed in a series to the top plate s tube, is clamped to the sidewall tabs where they are bolted to the support ring. Flowing liquid helium through these tubes cools the entire shroud to 5 K. The entire shroud is wrapped loosely in a layer of double-aluminized Kapton. The support ring s inner diameter is the largest possible hole through which the test item can extend into the shroud. Twelve custom-sized trapezoidal copper sheets extend inward from the support ring to within a few millimeters of the test item. Attached to the inner edge of each of these sheets is a custom-shaped strip of Kapton, which is aluminum- coated on the warm-facing (outer) side, and has thin Dacron netting attached to its cold-facing side. This Kapton rests against the test item, but the Dacron keeps it from making significant thermal contact. The result is a non-contact, radiatively reflective thermal closeout with essentially no gap through which radiation can pass. In this way, the part of the test item outside the shroud can be heated to relatively high temperatures without any radiative heat leaking to the inside.

Tuttle, James↗

FInd Gas Source

FIGS is a neural network software that ingests real time synchronized field data on environmental flow fields and turbulence and gas concentration variations at high frequency and uses an error minimization algorithm to locate the gas source and quantify its strength. The software can be interfaced with atmospheric, oceanic and subsurface instruments in a variety of platforms stationary or mobile (e.g. cars, UAVs, submersible vehicles or boreholes) and used to find gas sources by smart use of data and phenomenology. FIGS can be trained by phenomenological model of the flow fields in the environment of interest and/or be calibrated by controlled release. After initial deployment the FIGS learning will grow with time as it accumulates data on source quantification. FIGS can be installed on any computer from small beagle-bones for field deployment/end-use to PC/MACs/main-frame for training/analysis. FIGS has been trained (using LANL's high resolution atmospheric simulations) and calibrated, tested and evaluated in the field and shown to perform well in finding and quantifying methane leaks at 10-100m scales at well pads by ingesting atmospheric measurements. The code is applicable to gas and particle source location at large scales.

Travis, Bryan↗

Effects of flow separation and cove leakage on pressure and heat-transfer distributions along a wing-cove-elevon configuration at Mach 6.9

External and internal pressure and cold-wall heating-rate distributions were obtained in hypersonic flow on a full-scale heat-sink representation of the space shuttle orbiter wing-elevon-cove configuration in an effort to define effects of flow separation on cove aerothermal environment as a function of cove seal leak area, ramp angle, and free-stream unit Reynolds number. Average free-stream Mach number from all tests was 6.9; average total temperature from all tests was 3360 R; free-stream dynamic pressure ranged from about 2 to 9 psi; and wing angle of attack was 5 deg (flow compression). For transitional and turbulent flow separation, increasing cove leakage progressively increased heating rates in the cove. When ingested mass flow was sufficient to force large reductions in extent of separation, increasing cove leakage reduced heating rates in the cove to those for laminar attached flow. Cove heating-rate distributions calculated with a method that assumed laminar developing channel flow agreed with experimentally obtained distributions within root-mean-square differences that varied between 11 and 36 percent where cove walls were parallel for leak areas of 50 and 100 percent.

Deveikis, W. D.↗

SSME Propellant Path Leak Detection

The primary objective of this phase of the investigation is the experimental validation of techniques for detecting and analyzing propellant path external leaks which have a high probability of occurring on the SSME. The selection of candidate detection methods requires a good analytic model for leak plumes which would develop from external leaks and an understanding of radiation transfer through the leak plume. One advanced propellant path leak detection technique is obtained by using state-of-art technology of infrared (IR) thermal imaging systems combined with computer, digital image processing and expert systems for the engine protection. The feasibility of the IR leak plume detection will be evaluated on subscale simulated laboratory plumes to determine sensitivity, signal to noise, and general suitability for the application. The theoretical analysis was undertaken with the objective of developing and testing simple, easy-to-use models to predict the amount of radiation coming from a radiation source, background plate (BP), which can be absorbed, emitted and scattered by the gas leaks.

Roger Crawford↗

BioID/LID System Cartridge Testing Report

LLNL produced two lots of lyophilized LAMP assay containing cartridges, LNL022818 and LNL071818, for testing on Gen3 BioID systems. Thirty-nine cartridges were tested for lot LNL022818. All thirty-nine cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Five different templates were tested on these 39 cartridges. The BioID system detected 79.1% true positives and 9.3% false positives along with 98.9% true negatives and 2.9% false negatives for cartridge lot LNL022818. Thirty cartridges were tested for lot LNL071818. It was noted early that due to a manufacturing issue with the cartridges related to incomplete sonic welding of the cartridge, a large fraction of lot LNL071818 cartridges leaked. Insufficient funds were available to replace this lot of cartridges. Twenty three of 30 cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Four different templates were tested on these 30 cartridges. The BioID system detected 77% true positives and 23% false positives along with 96.9% true negatives and 3.1% false negatives for cartridge lot LNL071818. For all tested cartridges using DNA template, DNA was added at a final concentration of 25 pg/ul. All reactions contained positive control DNA at 2.5 pg/ul.

42 ENGINEERING↗

Study of the integrity of pressurized LEH window assemblies at cryogenic temperatures for NIF targets

The National Ignition Facility (NIF) is a directorate of LLNL, a DOE Lab, and is home to the world’s largest laser. This laser shoots its 192 beams at a target about the size of a pencil eraser. Within the target are two main chambers; and depending on the type of shot, those chambers need to be pressurized to a certain point at a very low temperature (18 Kelvin). The component used for keeping the hohlraum at its designated pressure is a Laser Entrance Hole (LEH) window, made from a thin (0.5um) polyimide film and an aluminum washer attached with a miniscule amount of polymeric adhesive. One issue that has been known to happen is the chambers will leak, at very low rates (5.0E-7 mBar-liter/s and under). At higher pressures significantly larger leak rates have been observed.There are three proposed mechanisms by which the LEH windows are leaking. The first is that there is a small pinhole somewhere in the freestanding film. This is the most unlikely because before any film is shipped from Luxel, it must pass a 50-75 torr room temperature pressure test. The second is a tear in the film at the edge of the washer. This type of damage suggests that the film is under additional stress at this edge portion and/or the edge of the washer itself is what is doing the damage. Lastly, it has been hypothesized that there are small channels under the window that do not get completely filled by the glue and, if they connect to the edge of the freestanding portion of the film, then the pressure can escape through them. These channels were the mechanism being most directly tested over the course of the experiments.

42 ENGINEERING↗

xPLSS Structural Backplate Design, Manufacture, and Test Overview

NASA Johnson Space Center (JSC) has been developing and building a new detailed design of the Exploration Extravehicular Mobility Unit (xEMU) space suit to support future International Space Station (ISS) and Lunar Artemis missions. The Exploration Portable Life Support System (xPLSS) of the xEMU contains some clever new technologies to meet the requirements to provide Extra Vehicular Activity (EVA) capability on the ISS and the Moon. The suit must interface with and fit through ports and airlocks of at least three vehicles: ISS, Human Landing System (HLS), and Gateway. The first partial xPLSS experimental flight unit called SWME EXPRESS Rack Flight Experiment (SERFE) that was a rack-deployed thermal control system payload on the ISS for two years (2020-2022). The first complete assembly of the xEMU was built as a Design Verification Test (DVT) unit (2022); similar to but more extensive than an Engineering Development Unit (EDU). The xPLSS Backplate serves not only as the structural backbone of the xPLSS and SERFE systems but also contains innovative design features to reduce the: mass, complexity, parts count, number ofseals (and therefore leak potential), and outer dimensions of the entire assembly. This paper provides an overview of these new design features, manufacturing processes, system interfaces, and SERFE/DVT test results of the Backplate as part of the xPLSS/xEMU.

xPLSS↗

xPLSS Structural Backplate Design, Manufacture, and Test Overview

NASA Johnson Space Center (JSC) has been developing and building a new detailed design of the Exploration Extravehicular Mobility Unit (xEMU) space suit to support future International Space Station (ISS) and Lunar Artemis missions. The Exploration Portable Life Support System (xPLSS) of the xEMU contains some clever new technologies to meet the requirements to provide Extra Vehicular Activity (EVA) capability on the ISS and the Moon. The suit must interface with and fit through ports and airlocks of at least three vehicles: ISS, Human Landing System (HLS), and Gateway. The first partial xPLSS experimental flight unit called SWME EXPRESS Rack Flight Experiment (SERFE) that was a rack-deployed thermal control system payload on the ISS for two years (2020-2022). The first complete assembly of the xEMU was built as a Design Verification Test (DVT) unit (2022); similar to but more extensive than an Engineering Development Unit (EDU). The xPLSS Backplate serves not only as the structural backbone of the xPLSS and SERFE systems but also contains innovative design features to reduce the: mass, complexity, parts count, number ofseals (and therefore leak potential), and outer dimensions of the entire assembly. This paper provides an overview of these new design features, manufacturing processes, system interfaces, and SERFE/DVT test results of the Backplate as part of the xPLSS/xEMU.

xPLSS↗

Cryogenic Propellant Long-term Storage With Zero Boil-off

Significant boil-off losses of cryogenic propellant storage systems in long-duration space mission applications result in additional propellant and large tanks. The zero boil-off (ZBO) concept consists of an active cryo-cooling system integrated with traditional passive thermal insulation. The potential mass reductions with the ZBO concept are Substantial; therefore, further exploration through technology programs has been initiated within NASA. A large-scale demonstration of the ZBO concept has been devised utilizing the Marshall Space Flight Center (MSFC) Multipurpose Hydrogen Test Bed (MHTB) along with a cryo-cooler unit. The cryo-cooler with the MHTB and spraybar recirculation/mixer system in a manner that enables thermal energy removal at a rate that equals the total tank heat leak. The liquid hydrogen is withdrawn from the tank, passed through a heat exchanger, and then the chilled liquid is sprayed back into the tank through a spraybar. The test series will be performed over a 30-40 day period. Tests will be conducted at multiple fill levels and various mixer operational cycles to demonstrate concept viability and to provide benchmark data to be used in analytical model development. In this paper. analytical models for heat flows through the MHTB tank, cryo-cooler performance. and spraybar performance will be presented.

Hedayat, A.↗