Search NASA⌕ Search

SEARCH · Search NASA

Results for “Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Correlation of Qualification and Accelerated Testing with Field Degradation

Qualification testing of solar photovoltaic (PV) modules per IEC 61215 standard encompasses a set of well-defined accelerated stress tests (irradiation, environmental, mechanical and electrical) with strict pass/fail criteria based on functionality/performance, electrical and mechanical safety, and visual requirements. The qualification testing does not identify all the possible reliability failures or durability issues witnessed in the actual field. However, it does identify the major/catastrophic design quality issues (infant mortality), which could occur early in a module’s field life. Unfortunately, in the industry, there is no consensus-based standard or protocol available to validate manufacturers’ warranty period claims based on the end-of-life wear-out failure mechanisms. Being able to predict the field degradation rates and lifetime using mode-specific accelerated tests on moderately field-aged modules, for example 10 years, for certain commonly occurring degradation modes would be a powerful contribution to all the stakeholders of the PV industry. There is a need to formulate guidelines to find the correlation of accelerated testing with field degradation for individual degradation modes observed in the field. Potential approaches to fulfill this need were experimented in this project and are presented in this report. Two of the most commonly seen degradation modes – encapsulant browning and solder bond thermomechanical fatigue – are addressed in this report through presenting the accelerated testing methods and physical modelling approaches. Two accelerated test methods (UV and thermal cycling) were designed to induce the wear-out mechanisms in the modules and not infant mortality failures. To focus on the wear-out failure modes, the tests were performed on field-aged modules, instead of fresh modules, with known degradation rates and degradation modes. The degradation rates were measured based on the degradation rates of individual cell parameters (short-circuit current, I sc and series resistance, R s ) instead of the degradation rate of maximum power (P max ) which cannot be used to study any specific/limited degradation mode as the P max degradation could be caused by many different degradation modes. The key characteristic parameter considered for encapsulant discoloration and solder bond degradation is I sc and R s , respectively. The developed physical models/equations relating the testing degradation data and field weather data were utilized to determine the acceleration factor (AF) and to predict the degradation rate for a specific degradation mode of PV modules installed in two different climates, Arizona (hot) and New York (cold). The predicted degradation rates for encapsulant browning and solder bond degradation have also been validated against the actual measured field degradation rates. UV testing cost reduction: To determine acceleration factor, single UV chamber was used for accelerated UV testing at three different temperatures simultaneously, instead of three chambers for three temperatures (or one chamber sequentially which is an extremely time-consuming approach). A passive heating approach was successfully used to achieve and maintain multiple temperatures in the accelerated UV chamber. Foam insulation boards of varying thicknesses were utilized to obtain three different temperatures for UV testing. However, these foam materials tend to disintegrate in the presence of moisture. To alleviate this problem, silicone heating blankets with temperature controls and humidifier can be used if the UV testing is to be performed under hot-humid conditions instead of conventional hot-dry conditions. Thermal cycling testing cost reduction: Single thermal cycling chamber was used for accelerated thermal cycling testing at three different upper temperatures simultaneously, instead of three chambers for three upper temperatures (or one chamber sequentially which is an extremely time-consuming approach). An active heating approach based on silicone heating blankets was successfully used to achieve and maintain multiple upper temperatures in the accelerated thermal cycling chamber. Such blankets provide stable temperature control and thereby more reliable and repeatable for replicate experiments.

14 SOLAR ENERGY↗

Tensile and fatigue characterization of multifunctional composites

This research is part of a larger effort to develop advanced self-sensing multifunctional polymer composites that are both lightweight and high-strength, while also enabling structural damage detection, fatigue cycle monitoring, and service life prediction. These multifunctional composites are particularly sought after in the automotive industry for their potential to significantly reduce vehicle weight and simultaneously provide additional functionality like condition monitoring to enhance safety. This study examines the tensile and fatigue properties of a composite material composed of acrylonitrile butadiene styrene (ABS) polymer embedded with piezoelectric barium titanate (BaTiO3) nanoparticles. The integration of BaTiO3 nanoparticles not only supplies the material with self-sensing capabilities but also influences its mechanical properties. While a high content of BaTiO3 nanoparticles is desired to enhance sensing capacity, the brittle nature of such materials causes concerns of decreased strength characteristics. To explore this, various composite samples were fabricated with nanoparticle contents ranging from 0 wt% to 20 wt%. These samples underwent tensile testing to measure their ultimate tensile strengths and Young’s moduli. Following this, fatigue tests were conducted to generate S-N curves, which are essential for understanding the material's durability under cyclic loading. The findings from these tests assess the impact of nanoparticle content on the composite’s tensile strength and fatigue life, providing essential insights that can guide the optimization and design of future self-sensing multifunctional composites. The results suggest that 5 wt% BaTiO3 provides an optimal balance between mechanical properties and nanoparticle concentration, making it a promising composition for semi-structural applications.

Bowland, Christopher [ORNL] (ORCID:000000021229431↗

RERTR-7 Irradiation Summary Report

The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-7A, was designed to test several modified fuel designs to target fission densities representative of a peak low enriched uranium (LEU) burnup in excess of 90% U-235 at peak experiment power sufficient to generate a peak surface heat flux of approximately 300 W/cm 2 . The RERTR-7B experiment was designed as a high power test of 'second generation' dispersion fuels at peak experiment power sufficient to generate a surface heat flux on the order of 230 W/cm 2 . The following report summarizes the life of the RERTR-7A and RERTR-7B experiments through end of irradiation, including as-run neutronic analyses, thermal analyses and hydraulic testing results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Functional strategies drive community assembly of stream fishes along environmental gradients and across spatial scales

Trade-offs among functional traits produce multi-trait strategies that shape species interactions with the environment and drive the assembly of local communities from regional species pools. Stream fish communities vary along stream size gradients and among hierarchically structured habitat patches, but little is known about how the dispersion of strategies varies along environmental gradients and across spatial scales. We used null models to quantify the dispersion of reproductive life history, feeding, and locomotion strategies in communities sampled at three spatial scales in a prairie stream network in Kansas, USA. Strategies were generally underdispersed at all spatial scales, corroborating the longstanding notion of abiotic filtering in stream fish communities. We tested for variation in strategy dispersion along a gradient of stream size and between headwater streams draining different ecoregions. Reproductive life history strategies became increasingly underdispersed moving from downstream to upstream, suggesting that abiotic filtering is stronger in headwaters. This pattern was stronger among reaches compared to mesohabitats, supporting the premise that differences in hydrologic regime among reaches filter reproductive life history strategies. Feeding strategies became increasingly underdispersed moving from upstream to downstream, indicating that environmental filters associated with stream size affect the dispersion of feeding and reproductive life history in opposing ways. Weak differences in strategy dispersion were detected between ecoregions, suggesting that different abiotic filters or strategies drive community differences between ecoregions. Lastly, given the pervasiveness of multi-trait strategies in plant and animal communities, we conclude that the assessment of strategy dispersion offers a comprehensive approach for elucidating mechanisms of community assembly.

54 ENVIRONMENTAL SCIENCES↗

Estimating pediatric entrance skin dose from digital radiography examination using DICOM metadata: A quality assurance tool

Purpose: To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Methods: Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken from DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k{sub air}) value based on an x-ray characteristic radiation output curve; (2) scaling k{sub air} with a BSF value; and (3) correcting k{sub air} for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass–energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. Results: ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19–0.42 mGy for dual view chest, 0.28–1.2 mGy for AP abdomen, 0.18–0.65 mGy for LAT view skull, 0.15–0.63 mGy for dual view knee, and 0.10–0.12 mGy for bone age (left hand) examinations. Conclusions: A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for digital x-ray imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-T-361: Energy Dependent Radiation/light-Field Misalignment On Truebeam Linear Accelerator

Purpose: Verifying the co-incidence of the radiation and light field is recommended by TG-142 for monthly and annual checks. On a digital accelerator, it is simple to verify that beam steering settings are consistent with accepted and commissioned values. This fact should allow for physicists to verify radiation-light-field co-incidence for a single energy and accept that Result for all energies. We present a case where the radiation isocenter deviated for a single energy without any apparent modification to the beam steering parameters. Methods: The radiation isocenter was determined using multiple Methods: Gafchromic film, a BB test, and radiation profiles measured with a diode. Light-field borders were marked on Gafchromic film and then irradiated for all photon energies. Images of acceptance films were compared with films taken four months later. A phantom with a radio-opaque BB was aligned to isocenter using the light-field and imaged using the EPID for all photon energies. An unshielded diode was aligned using the crosshairs and then beam profiles of multiple field sizes were obtained. Field centers were determined using Omni-Pro v7.4 software, and compared to similar scans taken during commissioning. Beam steering parameter files were checked against backups to determine that the steering parameters were unchanged. Results: There were no differences between the configuration files from acceptance. All three tests demonstrated that a single energy had deviated from accepted values by 0.8 mm in the inline direction. The other two energies remained consistent with previous measurements. The deviated energy was re-steered to be within our clinical tolerance. Conclusions: Our study demonstrates that radiation-light-field coincidence is an energy dependent effect for modern linacs. We recommend that radiation-light-field coincidence be verified for all energies on a monthly basis, particularly for modes used to treat small fields, as these may drift without influencing results from other tests.

60 APPLIED LIFE SCIENCES↗

WE-E-201-01: Use and Abuse of Common Statistics in Radiological Physics

Physicists are often expected to have a solid grounding in experimental design and statistical analysis, sometimes filling in when biostatisticians or other experts are not available for consultation. Unfortunately, graduate education on these topics is seldom emphasized and few opportunities for continuing education exist. Clinical physicists incorporate new technology and methods into their practice based on published literature. A poor understanding of experimental design and analysis could Result in inappropriate use of new techniques. Clinical physicists also improve current practice through quality initiatives that require sound experimental design and analysis. Academic physicists with a poor understanding of design and analysis may produce ambiguous (or misleading) results. This can Result in unnecessary rewrites, publication rejection, and experimental redesign (wasting time, money, and effort). This symposium will provide a practical review of error and uncertainty, common study designs, and statistical tests. Instruction will primarily focus on practical implementation through examples and answer questions such as: where would you typically apply the test/design and where is the test/design typically misapplied (i.e., common pitfalls)? An analysis of error and uncertainty will also be explored using biological studies and associated modeling as a specific use case. Learning Objectives: Understand common experimental testing and clinical trial designs, what questions they can answer, and how to interpret the results Determine where specific statistical tests are appropriate and identify common pitfalls Understand the how uncertainty and error are addressed in biological testing and associated biological modeling.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP1-04: Novel 3D Printed Plastic Cutouts Filled with Aluminum Oxide for Same Day Electron Radiotherapy

Purpose: Clinics that outsource electron cutout manufacturing may be unable to simulate and treat patients on the same day. To enable same day treatment, we investigate the use of 3D printed hollow cutouts filled with 30 grit Al{sub 2}O{sub 3} powder. We verified the dosimetric equivalence of such a cutout relative to an outsourced Copper cutout. Methods: Printing was performed using a Ultibots Kossel 250 V-Slot 3D printer and polylactic acid filament. Printing files were derived from an in-house 3D model designed to mate with a Varian 6 cm electron cone. Relative to conventional cutouts (Copper or Cerrobend), the height of the hollow plastic cutout was extended by 1.0 cm to increase attenuation. Measurements were performed for 6 MeV in solid water at dmax (1.4 cm) with Gafchromic™ EBT3 film; the cutout was kidney-shaped with a long and short axis of approximately 5 and 2 cm, respectively. The Copper cutout was based on an outline of the 3D printed cutout.A calibration film was exposed immediately after the electron irradiations. All films, including an un-irradiated one, were from the same batch. Films were scanned on an Epson 10000XL flatbed scanner. Film analysis was performed in DoseLab (MOBIUS Medical Systems, Houston, Tx). Results: Visual comparison of the physical cutouts revealed that the Copper cutout had a slightly smaller opening than the printed cutout. Line profiles through the registered films indicated agreement within 5% in the open section. 99.9% of pixels passed gamma analysis with 2% local percent difference, 2 mm DTA, and a 25% threshold. Conclusion: Same day simulation and treatment with electrons is feasible with 3D printing of a hollow cutout filled with Al{sub 2}O{sub 3}. Future work will include evaluations of additional cutout shapes at different depths for higher energies. Other printing materials, such as bismuth, are being tested.

60 APPLIED LIFE SCIENCES↗

Pathogenicity testing of influenza candidate vaccine viruses in the ferret model

The development of influenza candidate vaccine viruses (CVVs) for pre-pandemic vaccine production represents a critical step in pandemic preparedness. The multiple subtypes and clades of avian or swine origin influenza viruses circulating world-wide at any one time necessitates the continuous generation of CVVs to provide an advanced starting point should a novel zoonotic virus cross the species barrier and cause a pandemic. Furthermore, the evolution and diversity of novel influenza viruses that cause zoonotic infections requires ongoing monitoring and surveillance, and, when a lack of antigenic match between circulating viruses and available CVVs is identified, the production of new CVVs. Pandemic guidelines developed by the WHO Global Influenza Program govern the design and preparation of reverse genetics-derived CVVs, which must undergo numerous safety and quality tests prior to human use. Confirmation of reassortant CVV attenuation of virulence in ferrets relative to wild-type virus represents one of these critical steps, yet there is a paucity of information available regarding the relative degree of attenuation achieved by WHO-recommended CVVs developed against novel viruses with pandemic potential. To better understand the degree of CVV attenuation in the ferret model, we examined the relative virulence of six A/Puerto Rico/8/1934-based CVVs encompassing five different influenza A subtypes (H2N3, H5N1, H5N2, H5N8, and H7N9) compared with the respective wild-type virus in ferrets. Despite varied virulence of wild-type viruses in the ferret, all CVVs examined showed reductions in morbidity and viral shedding in upper respiratory tract tissues. Furthermore, unlike the wild-type counterparts, none of the CVVs spread to extrapulmonary tissues during the acute phase of infection. While the magnitude of virus attenuation varied between virus subtypes, collectively we show the reliable and reproducible attenuation of CVVs that have the A/Puerto Rico/9/1934 backbone in a mammalian model. - Highlights: • Confirmation of candidate vaccine viruses (CVVs) attenuation of virulence was demonstrated. • All influenza CVVs showed reductions in morbidity compared to wild-type (wt) viruses. • When compared with the wt viruses, all CVVs exhibited reductions in virus shedding in ferrets.

60 APPLIED LIFE SCIENCES↗

SAVY-4000 Lifetime Extension Overview for FY23

The SAVY-4000 (hereafter “SAVY) was granted a 15 year design life as of June 11, 2019. Since that time, a concerted effort to evaluate the SAVY lifetime beyond 15 years initiated. Several key gaps in knowledge were identified by subject matter expert reviewers across the complex, along with testing that should be included or addressed in the next technical basis. While surveillance has not fundamentally changed since the last life extension, many key techniques have since been identified as necessary to evaluate key container performance requirements not addressed previously (i.e. drop qualification release rate). FY23 provided an opportunity to establish the groundwork for the development of those key techniques that aid in addressing DOE Manual 441.1-1 (hereafter “Manual”) requirements for safe storage of nuclear material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precise measurement of the half-life of the Fermi {beta} decay of {sup 26}Al{sup m}

State-of-the-art signal digitization and analysis techniques have been used to measure the half-life of the Fermi {beta} decay of {sup 26}Al{sup m}. The half-life was determined to be 6347.8 {+-} 2.5 ms. This new datum contributes to the experimental testing of the conserved-vector-current hypothesis and the required unitarity of the Cabibbo-Kobayashi-Maskawa matrix: two essential components of the standard model. Detailed discussion of the experimental techniques and data analysis and a thorough investigation of the statistical and systematic uncertainties are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AFIP-4 Irradiation Summary Report

The Advanced Test Reactor (ATR) Full size plate In center flux trap Position (AFIP) experiment AFIP-4 was designed to evaluate the performance of monolithic uranium-molybdenum (U-Mo) fuels at a scale prototypic of research reactor fuel plates. The AFIP-4 test further examine the fuel/clad interface and its behavior under extreme conditions. After irradiation, fission gas retention measurements will be performed during post irradiation (PIE). The following report summarizes the life of the AFIP-4 experiment through end of irradiation, including a brief description of the safety analysis, as-run neutronic analysis results, hydraulic testing results, and thermal analysis results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

COMPARISON OF ELASTIC OF POROUS CORDIERITE BY FLEXURE AND DYNAMIC TEST METHODS

Previous work showed differences in apparent elastic modulus between mechanical flexure testing and resonance methods. Flexure tests have been conducted using non-contact optical systems to directly measure deflection for calculation of elastic modulus. Dynamic test methods for elastic modulus measurement were conducted on the same material for comparison. The results show significant difference in the apparent elastic modulus for static flexure versus dynamic methods. The significance of the difference in apparent elastic modulus on thermal stress and the hypotheses for these differences will be discussed. Dynamic measurement (resonance) and static measurement (mechanical) produce different values for elastic modulus of porous cordierite ceramic. The elastic modulus from resonance is a measure of the material response at very low strain which is different from the material response in a mechanical test with relatively large strain. The apparent elastic moduli for dynamic versus static test methods in this study are different by a factor of two. This result has significant impact on calculated stress and life in an aftertreatment component.

36 MATERIALS SCIENCE↗

Solar PV Energy: Myths and Realities (Spanish Translation)

Solar energy is growing at record rates, but its rapid expansion brings little-discussed challenges. I will present the global deployment goals and how these translate into future amounts of waste and critical material needs. I will also address common myths about end of life, toxicity, and the real impacts of technological changes, and why research in reliability and field testing is essential to ensure a resilient, sustainable network prepared for the next decades of photovoltaic growth.

14 SOLAR ENERGY↗

Improving Solar PV Degradation Prediction Certainty: PREDICTS2 (Final Technical Report)

The rate and type of in-service PV performance degradation vary for different module designs, vintages, and operating climates. The current IEC 61215 module qualification testing standard can be used to identify design and manufacturing flaws that may lead to early life failures, but it was not intended to accurately predict degradation rates in the first 5 to 10 years of a PV plant’s lifetime, nor long-term performance, under varied operating conditions. Correlations between accelerated aging data and real-world degradation data are needed to better predict wear-out degradation in response to environmental stressors, such as elevated temperature, temperature cycling, moisture, wind load, and solar radiation. The PREDICTS2 project aged 36 pristine-condition ‘spare’ modules from a commercial PV power plant in the U.S. Southwest using the IEC 61215 and Qualification Plus (Qual Plus) testing standards. The study is unique in its ability to compare performance degradation data for fielded modules operating outdoors for 6 years in a commercial plant environmental with degradation data for modules of the same make, model and vintage that have been aged artificially in an indoor laboratory. Changes in individual module current-voltage (I-V) curve data were measured before and after the artificial aging process and compared to I-V curve data for the fielded modules. This project advanced the industry’s understanding of how environmental stressors affect performance degradation and established relationships between degradation mechanisms and changes to module electrical parameters and power loss. Improved certainty in degradation rates is expected to be the greatest source of LCOE reduction resulting from this project. Reducing the spread in the degradation rate probability distribution lowers project risk, which translates to lower project financing costs.

14 SOLAR ENERGY↗

Tensile and Fatigue Testing and Material Hardening Model Development for 508 LAS Base Metal and 316 SS Similar Metal Weld under In-air and PWR Primary Loop Water Conditions

This report provides an update on an assessment of environmentally assisted fatigue for light water reactor components under extended service conditions. This report is a deliverable in September 2015 under the work package for environmentally assisted fatigue under DOE’s Light Water Reactor Sustainability program. In an April 2015 report we presented a baseline mechanistic finite element model of a two-loop pressurized water reactor (PWR) for systemlevel heat transfer analysis and subsequent thermal-mechanical stress analysis and fatigue life estimation under reactor thermal-mechanical cycles. In the present report, we provide tensile and fatigue test data for 508 low-alloy steel (LAS) base metal, 508 LAS heat-affected zone metal in 508 LAS–316 stainless steel (SS) dissimilar metal welds, and 316 SS-316 SS similar metal welds. The test was conducted under different conditions such as in air at room temperature, in air at 300 oC, and under PWR primary loop water conditions. Data are provided on materials properties related to time-independent tensile tests and time-dependent cyclic tests, such as elastic modulus, elastic and offset strain yield limit stress, and linear and nonlinear kinematic hardening model parameters. The overall objective of this report is to provide guidance to estimate tensile/fatigue hardening parameters from test data. Also, the material models and parameters reported here can directly be used in commercially available finite element codes for fatigue and ratcheting evaluation of reactor components under in-air and PWR water conditions.

316 Stainless Steel↗

RERTR-8 Irradiation Summary Report

The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-8, was designed to test monolithic mini-fuel plates fabricated via hot isostatic pressing (HIP), the effect of molybdenum (Mo) content on the monolithic fuel behavior, and the efficiency of ternary additions to dispersion fuel particles on the interaction layer behavior at higher burnup. The following report summarizes the life of the RERTR-8 experiment through end of irradiation, including as-run neutronic analysis, thermal analysis and hydraulic testing results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗