Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Installation and commissioning of the ion source systems for the new spallation neutron source 2.5 MeV injector

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world’s most intense pulsed neutron beams to a wide array of instruments, which are used to conduct investigations in many fields of engineering, physics, chemistry, material science, and biology. Neutrons are produced by spallation of liquid Hg by the bombardment of short (∼1 µs), intense (∼35 A) pulses of protons delivered at 60 Hz by an accumulator ring which is fed by a high-intensity, 1 GeV, H− LINAC (linear accelerator). This facility has operated nearly continuously since 2006 but has recently undergone a 4-month maintenance period, which featured a complete replacement of the 2.5 MeV injector feeding the LINAC. The new injector was developed at ORNL in an off-line beam test facility and consists of an ion source, low energy beam transport, and a Radio Frequency Quadrupole (RFQ). This report first describes the installed configuration of the new injector detailing the ion source system. The first beam current, RFQ transmission, emittance, and energy measurements from the injector installed on the SNS are reported. These data not only show a significant performance improvement for our existing facility but will also make accessible the higher beam current requirements for future SNS upgrade projects: the proton power upgrade and second target station.

Welton, R. F.↗

Flexible Momentum Compaction Return Arcs for RLAs

Neutrino Factories and Muon Colliders require rapid acceleration of short-lived muons to multi-GeV and TeV energies. A Recirculating Linear Accelerator (RLA) that uses a single Linac and teardrop return arcs can provide exceptionally fast and economical acceleration to the extent that the focusing range of the RLA quadrupoles allows each muon to pass several times through each high-gradient cavity and the cost of the return arcs is appropriate. Flexible Momentum Compaction (FMC) lattice designs for the teardrop return arcs provide sufficient momentum acceptance to allow multiple passes of each sign of muon in one string of magnets to improve cost-effectiveness.

43 PARTICLE ACCELERATORS↗

SU-F-T-551: Beam Hardening and Attenuation of Photon Beams Using Integral Quality Monitor in Radiotherapy

Purpose: Aim of the multi-centre study was to analyse beam hardening effect of the Integral Quality Monitor (IQM) for high energy photon beams used in radiotherapy with linear accelerators. Generic values for attenuation coefficient k(IQM) of IQM system were additionally investigated. Methods: Beam hardening effect of the IQM system was studied for a set of standard nominal photon energies (6 MV–18 MV) and two flattening filter free (FFF) energies (6 MV FFF and 10 MV FFF). PDD curves were measured and analysed for various square radiation fields, with and without IQM in place. Differences between PDD curves were statistically analysed through comparison of respective PDD-20,10 values. Attenuation coefficients k(IQM) were determined for the same range of photon energies. Results: Statistically significant differences in beam qualities for all evaluated high energy photon beams were found, comparing PDD-20,10 values derived from PDD curves with and without IQM in place. Significance of beam hardening effect was statistically proven with high confidence (p < 0,01) for all analysed photon beams except for 15 MV (p = 0,078), although relative differences in beam qualities were minimal, ranging from 0,1 % to 0,5 %. Attenuation of the IQM system showed negligible dependence on radiation field size. However, clinically important dependence of kIQM versus TPRs20,10 was found: 0,941 for 6 MV photon beams, to 0,959 for 18 MV photon beams, with highest uncertainty below 0,006. k(IQM) versus TPRs were tabulated and polynomial equation for the determination of k(IQM) is suggested for clinical use. Conclusion: There was no clinically relevant beam hardening, when IQM system was on linear accelerators. Consequently, no additional commissioning is needed for the IQM system regarding the determination of beam qualities. Generic values for k(IQM) are proposed and can be used as tray factors for complete range of examined photon beam energies.

60 APPLIED LIFE SCIENCES↗

Concept, implementation and commissioning of the automation system for the accelerator module test facility AMTF

The European XFEL project launched on June 5, 2007 will require about 103 accelerator modules as a main part of the XFEL linear accelerator. All superconducting components constituting the accelerator module like cavities and magnets have to be tested before the assembly. For the tests of the individual cavities and the complete modules an XFEL Accelerator Module Test Facility (AMTF) has been erected at DESY. The process control system EPICS (Experimental Physics and Industrial Control System) is used to control and operate the cryogenic plant and all its subcomponents. A complementary component of EPICS is the Open Source software suit CSS (Control System Studio). CSS is an integrated engineering, maintenance and operating tool for EPICS. CSS enables local and remote operating and monitoring of the complete system and thus represents the human machine interface. More than 250 PROFIBUS nodes work at the accelerator module test facility. DESY installed an extensive diagnostic and condition monitoring system. With these diagnostic tools it is possible to examine the correct installation and configuration of all PROFIBUS nodes in real time. The condition monitoring system based on FDT/DTM technology shows the state of the PROFIBUS devices at a glance. This information can be used for preventive maintenance which is mandatory for continuous operation of the AMTF facility. The poster will describe all steps form engineering to implementation and commissioning.

43 PARTICLE ACCELERATORS↗

Ion sources for MedAustron

The MedAustron Ion therapy center will be constructed in Wiener Neustadt (Austria) in the vicinity of Vienna. Its accelerator complex consists of four ion sources, a linear accelerator, a synchrotron, and a beam delivery system to the three medical treatment rooms and to the research irradiation room. The ion sources shall deliver beams of H{sub 3}{sup 1+}, C{sup 4+}, and light ions with utmost reliability and stability. This paper describes the features of the ion sources presently planned for the MedAustron facility, such as ion source main parameters, gas injection, temperature control, and cooling systems. A dedicated beam diagnostics technique is proposed in order to characterize electron cyclotron resonance (ECR) ion beams; in the first drift region after the ion source, a fraction of the mixed beam is selected via moveable aperture. With standard beam diagnostics, we then aim to produce position-dependant observables such as ion-current density, beam energy distribution, and emittance for each charge states to be compared to simulations of ECR e-heating, plasma simulation, beam formation, and transport.

43 PARTICLE ACCELERATORS↗

Free electron lasers: Present status and future challenges

With the scientific successes of the soft X-ray FLASH facility in Germany and the recent spectacular commissioning of the Linac Coherent Light Source at SLAC, free electron lasers are poised to take center stage as the premier source of tunable, intense, coherent photons of either ultra-short time resolution or ultra-fine spectral resolution, from the far infrared to the hard X-ray regime. This paper examines the state of the art in FEL performance and the underlying enabling technologies. It evaluates the state of readiness of the three basic machine architectures—SASE FELs, seeded FELs, and FEL oscillators—for the major X-ray science user facilities on the 5–10 years time scale and examines the challenges that lie ahead for FELs to achieve their full potential throughout the entire spectral range. In soft and hard X-rays, high longitudinal coherence, in addition to full transverse coherence, will be the key performance upgrade; ideas using laser-based or self-seeding or oscillators can be expected to be qualitatively superior to today&#x27;s SASE sources. Short pulses, from femtoseconds to attoseconds, can be realistically envisioned. With high repetition rate electron sources coupled to superconducting radiofrequency linear accelerators, unprecedented average beam brightness will be possible and many users would be served simultaneously by a single accelerator complex.

43 PARTICLE ACCELERATORS↗

LCLS undulator production.

Design and construction of the undulators for the linac coherent light source (LCLS) at the Stanford Linear Accelerator Center (SLAC) is the responsibility of Argonne National Laboratory (ANL). A full-scale prototype undulator was constructed in-house and extensively tested at Argonne's advanced photon source (APS). The device was tunable to well within the LCLS requirements and was stable for five years. Experience constructing the prototype undulator led us to conclude that with appropriate engineering design and detailed assembly procedures, precision undulators can be constructed by highly-qualified industrial vendors without undulator-construction experience. Argonne's detailed technological knowledge and experience were transferred to the successful bidders who produced outstanding undulators. Our production concept for the 3.4-m-long, fixed-gap, planar-hybrid undulators with a 30-mm period is discussed. Manufacturing, quality assurance, and acceptance testing details are also presented.

43 PARTICLE ACCELERATORS↗

Weekly Verification of Dosimetric Data for Virtual Wedge Using a 2D Diode Detector Array

A linac manufacturer has recommended that users measure virtual wedge (VW) angle and VW factor as a weekly quality assurance (QA) procedure. The purpose of this study was to investigate whether a 2D diode detector array (MapCHECK{sup TM}) is a useful tool for the verification of dosimetric data for VW. Measurements were performed on 2 linear accelerators (4, 6, and 10 MV) at 10-cm depth for a field size of 10 x 10 cm{sup 2} and with wedge angles of 15, 30, 45, and 60{sup o}. To verify the VW dose distributions generated by the treatment planning system (TPS), we confirmed that agreement between TPS data and measurements were {<=}2% dose difference or 2-mm distance-to-agreement based on American Association of Physicists in Medicine Task Group Report 53 (AAPM TG-53). We present here the results of a 1-year evaluation of VW by means of a 2D diode detector array. The maximum 2-fold standard deviation of the measured wedge angle turned out to be within 1.0, and all measured VW factors to be 1.00 {+-} 0.03. Although >95% of the points measured for 6 and 10 MV were generally within the tolerance of the dose distribution as mentioned above, the percentage of agreement between the measured data for 4 MV and TPS data were somewhat below 90%. We also verified generally good reproducibility for the dose distribution. The 2-D diode detector array was thus found to be useful as a tool for weekly VW QA.

61 RADIATION PROTECTION AND DOSIMETRY↗

Note: A pulsed laser ion source for linear induction accelerators

We have developed a high-current laser ion source for induction accelerators. A copper target was irradiated by a frequency-quadrupled Nd:YAG laser (266 nm) with relatively low intensities of 10{sup 8} W/cm{sup 2}. The laser-produced plasma supplied a large number of Cu{sup +} ions (∼10{sup 12} ions/pulse) during several microseconds. Emission spectra of the plasma were observed and the calculated electron temperature was about 1 eV. An induction voltage adder extracted high-current ion beams over 0.5 A/cm{sup 2} from a plasma-prefilled gap. The normalized beam emittance measured by a pepper-pot method was smaller than 1 π mm mrad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of two compact permanent magnet spectrometers for high current electron linear induction accelerators

In this work, two compact, permanent magnet, electron spectrometers have been built to measure the electron beam energy at the Dual Axis Radiographic Hydrodynamic Test facility. Using H - and OH - anions, the spectrometers were calibrated at the Special Technologies Laboratory in Santa Barbara, California (USA). The spectrometers were mounted on a custom drift tube that allows the magnet assemblies to be translated, which increases the path length of the electrons traveling through the magnetic field and therefore increases the upper bound of the measurable electron kinetic energy. The measurable range of electron kinetic energies is between 2.8 MeV–4.1 MeV for the first spectrometer and 14.1 MeV–21.1 MeV for the second spectrometer, with an overall measurement uncertainty of 0.32%.

47 OTHER INSTRUMENTATION↗

Beam loading compensation of traveling wave linacs through the time dependence of the rf drive

Beam loading in traveling-wave linear accelerating structures leads to unacceptable spread of particle energies across an extended train of bunched particles due to beam-induced field and dispersion. Methods for modulating the rf power driving linacs are effective at reducing energy spread, but for general linacs do not have a clear analytic foundation. We report here methods for calculating how to modulate the rf drive in arbitrarily nonuniform traveling-wave linacs within the convective-transport (power-diffusion) model that results in no additional energy spread due to beam loading (but not dispersion). Varying group velocity, loss factor, and cell quality factor within a structure, and nonzero particle velocity, are handled.

43 PARTICLE ACCELERATORS↗

SU-E-T-271: Direct Measurement of Tenth Value Layer Thicknesses for High Density Concretes with a Clinical Machine

Purpose: Use of high density concrete for radiation shielding is increasing, trading cost for space savings associated with the reduced tenth value layer (TVL). Precise information on the attenuation properties of high-density concretes is not readily present in the literature. A simple approximation is to scale the TVLs from NCRP 151 according relative increase in density. Here we present measured TVLs for heavy concretes of various densities using a built-in shielding test port. Methods: Concrete densities tested range from 2.35 g cc{sup −1} (147 pcf) to 5.6 g cc{sup −1} (350 pcf). Measurements were taken using 6MV, 6FFF, and 10FFF on a Varian Truebeam linear accelerator. Field sizes of 4x4, 9x9 and 30x30 cm{sup 2} were measured. A PTW 31013 Farmer chamber with a buildup cap was positioned 5.5 m from isocenter along the beam CAX. Concrete thicknesses were incremented in 5 cm intervals. Comparison TVLs were determined by scaling the NCRP 151 TVLs by the density ratio between the sample and standard density. Results: The trend from the first to equilibrium TVL was an increase in thickness, compared with MC modeling, which predicted a decrease. Measured TVLs for 6 MV were reduced by as much as 8.9 cm for TVL{sub 1} and 3.4 cm for TVL{sub E} compared to values scaled from NCRP 151. There was 1–3 mm difference in TVL between measurements done at 4x4 versus 30x30 cm{sup 2}. TVL{sub 1} for 6FFF was 1.1 cm smaller than TVL{sub 1} for 6MV, but TVL{sub E} was consistent to within 4 mm. TVL{sub 1} and TVL{sub E} for 10FFF were reduced by 8.8 and 3.7 cm from scaled NCRP values, respectively. Conclusions: We have measured the TVL thicknesses for various concretes. Simple density scaling of the values in NCRP 151 is a conservatively safe approximation, but actual TVLs may be reduced enough to eliminate some of the expense of installation. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that built the vault discussed in this abstract. Manjit Chopra is an employee of Universal Minerals International, Inc, the company that provided the aggregates for the high density concretes used in the vault construction.

43 PARTICLE ACCELERATORS↗

2.5-Dimensional numerical simulation of a high-current ion linear induction accelerator

Results are presented from numerical particle simulations of the transport and acceleration of a high-current tubular ion beam through one to five magnetically insulated accelerating gaps. The ion beam is neutralized by an accompanying electron beam. The possibility of transporting a high-current neutralized ion beam through five cusps is demonstrated. It is shown that the quality of the distribution function of a high-current ion beam at the exit from the accelerator can be substantially improved by optimizing the energy of the neutralizing electron beam. It is also shown that, by injecting additional high-current electron beams into the cusps, the accelerated ion beam can be made more monoenergetic and its divergence can be reduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗