Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Evaluation of the Room Temperature Field Quality Measurements of HL-LHC MQXFA Magnet Assemblies

As a member of the multi-lab U.S. High Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP), Lawrence Berkeley National Laboratory (LBNL) is assembling high-field Nb3Sn low-beta MQXFA quadrupole magnets for eventual installation at CERN as part of the HL-LHC upgrade. Each magnet undergoes room temperature magnetic measurements at two points during the assembly process: once after completion of the coil pack sub-assembly and once after the magnet is fully assembled and pre-loaded. Beyond its use to verify that each magnet assembly can meet operational requirements, the data from this two-stage measurement process allow for investigation into the impact of the pre-loading operation on field quality. Recent measurements on magnet rebuilds as well as exploratory coil pack reconfigurations also provide an opportunity to see in isolation the effects of changes to a magnet’s coil selection or coil layout. In this work, we present the magnetic measurement results of MQXFA magnets assembled or currently in process, focusing particularly on magnets with data corresponding to multiple builds, and discuss trends and insights which may be beneficial for the remaining MQXFA magnet production or for future Nb3Sn accelerator magnets.

Doyle, Jennifer [LBNL, Berkeley] (ORCID:0009000079↗

Change of Paradigm for the Reversed Field Pinch

The reversed field pinch (RFP) is a magnetic configuration germane to the tokamak, but it produces most of its magnetic field by the currents flowing inside the plasma; external coils provide only a small edge toroidal field whose sign is reversed with respect to the central one, whence the name of the configuration. Because of the presence of magnetic turbulence and chaos, the RFP had been considered for a long period as a terrible confinement configuration. However, recently a change of paradigm occurred for this device. Indeed, when the toroidal current is increased in the RFX-mod RFP in Padua (Italy), a self-organized helical state with an internal transport barrier (ITB) develops, and a broad zone of the plasma becomes hot (above 1 keV for a magnetic field above 0.8 T). The present theoretical picture of the RFP mainly comes from three-dimensional nonlinear visco-resistive MHD simulations whose dynamics has strong similarities with the experimental one, and triggered the experimental search for RFP states with improved confinement. The RFP ohmic state involves a helical electrostatic potential generating, as an electric drift, the so-called dynamo velocity field. The magnetic topology can bifurcate from a magnetic island to kink-like magnetic surfaces with higher resilience to magnetic chaos. This theoretical scenario was found to be relevant when ITB's enclosing a broad hot domain were discovered. The ITBs occur in the vicinity of the maximum of the safety factor. The new paradigm for the RFP supports its reappraisal as a low-external field, non-disruptive, ohmically heated approach to magnetic fusion, exploiting both self-organization and technological simplicity. Furthermore the RFP has the same Greenwald density limit as the tokamak, and it is an excellent test bed for the efficient control of multiple resistive wall modes. Its helical magnetic structure makes it germane to the stellarator too. As a result the RFP is also useful to bring support to the present two main lines of magnetic confinement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A measurement setup for acquiring the local magnetic properties of plastically deformed soft magnetic materials

This paper introduces a new measurement setup for extraction of the local magnetic properties. With the help of finite element method simulations, modifications are made on the previous double-C-yoke method. Small dimension measuring coils are applied in the stray field produced by the magnetic circuit to evaluate the local magnetic properties of the specified part of the specimen. Through the measurements with the plastically deformed materials at different temperatures, it indicates that the magnetic properties of soft magnetic materials are quite sensitive to plastic straining. After high-temperature thermal treatment on the plastically deformed specimen, the local magnetic properties exhibit an obvious recovery.

36 MATERIALS SCIENCE↗

Coil optimization for quasi-helically symmetric stellarator configurations

Filament-based coil optimizations are performed for several quasi-helical stellarator configurations, beginning with the one from Landreman & Paul ( Phys. Rev. Lett. , vol. 128, 2022, 035001), demonstrating that precise quasi-helical symmetry can be achieved with realistic coils. Several constraints are placed on the shape and spacing of the coils, such as low curvature and sufficient plasma–coil distance for neutron shielding. The coils resulting from this optimization have a maximum curvature 0.8 times that of the coils of the Helically Symmetric eXperiment (HSX) and a mean squared curvature 0.4 times that of the HSX coils when scaled to the same plasma minor radius. When scaled up to reactor size and magnetic field strength, no fast particle losses were found in the free-boundary configuration when simulating 5000 alpha particles launched at $3.5\,\mathrm {MeV}$ on the flux surface with a normalized toroidal flux of $s=0.5$ . An analysis of the tolerance of the coils to manufacturing errors is performed using a Gaussian process model, and the coils are found to maintain low particle losses for smooth, large-scale errors up to amplitudes of approximately $0.15\,\mathrm {m}$ . Another coil optimization is performed for the Landreman–Paul configuration with the additional constraint that the coils are purely planar. Visual inspection of the Poincaré plot of the resulting magnetic field-lines reveal that the planar modular coils alone do a poor job of reproducing the target equilibrium. Additional non-planar coil optimizations are performed for the quasi-helical configuration with $5\,\%$ volume-averaged plasma beta from Landreman et al. ( Phys. Plasma , vol. 29, issue 8, 2022, 082501), and a similar configuration also optimized to satisfy the Mercier criterion. The finite beta configurations had larger fast-particle losses, with the free-boundary Mercier-optimized configuration performing the worst, losing approximately $5.5\,\%$ of alpha particles launched at $s=0.5$ .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of Fatigue Cracks at Rivets with Self-Nulling Probe

A new eddy current probe developed at NASA Langley Research Center has been used to detect small cracks at rivets in aircraft lap splices [1]. The device has earlier been used to detect isolated fatigue cracks with a minimum detectable flaw size of roughly 1/2 to 1/3 the diameter of the probe [2]. The present work shows that the detectable flaw size for cracks originating at rivets can be greatly improved upon from that of isolated flaws. The use of a rotating probe method combined with spatial filtering has been used to detect 0.18 cm EDM notches, as measured from the rivet shank, with a 1.27 cm diameter probe and to detect flaws buried under the rivet head, down to a length of 0.076 cm, using a 0.32 cm diameter probe. The Self-Nulling Electromagnetic Flaw Detector induces a high density eddy current ring in the sample under test. A ferromagnetic flux focusing lens is incorporated such that in the absence of any inhomogeneities in the material under test only a minimal magnetic field will reach the interior of the probe. A magnetometer (pickup coil) located in the center of the probe therefore registers a null voltage in the absence of material defects. When a fatigue crack or other discontinuity is present in the test article the path of the eddy currents in the material is changed. The magnetic field associated with these eddy currents then enter into the interior of the probe, producing a large output voltage across the pickup coil leads. Further

Wincheski, Buzz↗

Nb3Sn High Field Magnets for the High Luminosity LHC Upgrade Project

The High Luminosity upgrade of the Large Hadron Collider at CERN requires a new generation of high field superconducting magnets. High field large aperture quadrupoles (MQXF) are needed for the low-beta triplets close to the ATLAS and CMS detectors, and high field two-in-one dipoles (11 T dipoles) are needed to make room for additional collimation. The MQXF quadrupoles, with a field gradient of 140 T/m in 150 mm aperture, have a peak coil field of 12.1 T at nominal current. The 11 T dipoles, with an aperture of 60 mm, have a peak coil field of 11.6 T at nominal current. Both magnets require Nb3Sn conductor and are the first applications of this superconductor to actual accelerator magnets.

43 PARTICLE ACCELERATORS↗

Elliptical Muon Helical Cooling Channel Coils

A helical cooling channel (HCC) consisting of a pressurized gas absorber imbedded in a magnetic channel that provides solenoid, helical dipole and helical quadrupole fields has shown considerable promise in providing six-dimensional phase space reduction for muon beams. The most effective approach to implementing the desired magnetic field is a helical solenoid (HS) channel composed of short solenoid coils arranged in a helical pattern. The HS channel along with an external solenoid allows the B$_z$ and B$_{\phi}$ components along the reference orbit to be set to any desired values. To set dB$_{\phi}$/dr to the desired value for optimum focusing requires an additional variable to tune. We shall show that using elliptical shaped coils in the HS channel allows the flexibility to achieve the desired dB$_{\phi}$/dr on the reference orbit without significant change to B$_z$ and B$_{\phi}$.

43 PARTICLE ACCELERATORS↗

Models of radiofrequency coupling for negative ion sources

Radiofrequency heating for ICP (inductively coupled plasma) ion sources depends on the source operating pressure, the presence or absence of a Faraday shield, the driver coil geometry, the frequency used, and the magnetic field configuration: in negative ion source a magnetic filter seems necessary for H{sup -} survival. The result of single particle simulations showing the possibility of electron acceleration in the preglow regime and for reasonable driver chamber radius (15 cm) is reported, also as a function of the static external magnetic field. An effective plasma conductivity, depending not only from electron density, temperature, and rf field but also on static magnetic field is here presented and compared to previous models. Use of this conductivity and of multiphysics tools for a plasma transport and heating model is shown and discussed for a small source.

43 PARTICLE ACCELERATORS↗

Analysis of toroidal phasing of resonant magnetic perturbation effects on edge transport in the DIII-D tokamak

Resonant Magnetic Perturbation (RMP) fields produced by external control coils are considered a viable option for the suppression of Edge Localized Modes in present and future tokamaks. In DIII-D, the RMPs are generated by six pairs of I-coils, each spanning 60° in toroidal angle, with the currents flowing in opposite directions in adjacent pairs of I-coils. Reversal of the currents in all I-coils, which produces a 60° toroidal shift in the RMP field configuration, generates uniquely different edge pedestal profiles of the density, temperature, and rotation velocities, implying different effects on the related edge transport phenomena caused by the difference in toroidal phase of the I-coil currents. The diffusive and non-diffusive transport effects of this RMP toroidal phase reversal are analyzed by comparing the ion and electron heat diffusivities, angular momentum transport frequencies, ion diffusion coefficients, and the particle pinch velocities interpreted from the measured profiles for the two phases of the I-coil currents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a cryogenically cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Program [Development of a cryogenically-cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Concept]

A cryogenically cooled hardware platform has been developed and commissioned on the Z Facility at Sandia National Laboratories in support of the Magnetized Liner Inertial Fusion (MagLIF) Program. MagLIF is a magneto-inertial fusion concept that employs a magnetically imploded metallic tube (liner) to compress and inertially confine premagnetized and preheated fusion fuel. The fuel is preheated using a ~2 kJ laser that must pass through a ~1.5-3.5-μm-thick polyimide “window” at the target’s laser entrance hole (LEH). As the terawatt-class laser interacts with the dense window, laser plasma instabilities (LPIs) can develop, which reduce the preheat energy delivered to the fuel, initiate fuel contamination, and degrade target performance. Cryogenically cooled targets increase the parameter space accessible to MagLIF target designs by allowing nearly 10 times thinner windows to be used for any accessible gas density. Thinner LEH windows reduce the deleterious effects of difficult to model LPIs. The Z Facility’s cryogenic infrastructure has been significantly altered to enable compatibility with the premagnetization and fuel preheat stages of MagLIF. The MagLIF cryostat brings the liquid helium coolant directly to the target via an electrically resistive conduit. This design maximizes cooling power while allowing rapid diffusion of the axial magnetic field supplied by external Helmholtz-like coils. A variety of techniques have been developed to mitigate the accumulation of ice from vacuum chamber contaminants on the cooled LEH window, as even a few hundred nanometers of ice would impact laser energy coupling to the fuel region. Here, the MagLIF cryostat has demonstrated compatibility with the premagnetization and preheat stages of MagLIF and the ability to cool targets to liquid deuterium temperatures in approximately 5 min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-R-06: Traumatic Brachial Plexus Injury Imaging, Developing a Coherent Clinical Protocol From Literature Review Through Practice

Purpose: Medical Physics teams can now play a critical role to help plan and provide studied approaches for traumatic brachial plexus MR imaging (tbpMRI). This is especially important for coordination with uncommon applications, since it is challenging to select the right modality, parameters, and train technologists on the essential components. For this work, we started with a review of the medical literature, performed crossover/volunteer studies to bring tbpMRI to practice with greater image QC and protocol management. Methods: To the best of our knowledge, we reviewed the known searchable domain for tbpMRI. We found 69 total articles since 2000. Articles were evaluated with our published protocol for literature management (LIMES3). Two physicists and two radiologists condensed the information from all articles into a knowledgebase. Results: The initial literature demonstrated great heterogeneity, which was a sign that this area needed greater consistency. Despite inconsistency and imprecision, we extracted the most relevant targets using our long-term experience with protocol development in MSK. We ran volunteers on six different magnets of various field strengths with multiple receiver coils, and rebuilt a coherent protocol for tbpMRI. Our radiologists rated LIMES3 work as superior. We have received referrals from the ER and have conducted four patient evaluations. Conclusion: Traumatic brachial plexus MRI has great possible benefits for patients. This work supports the complexity of tbpMRI scanning. As this is rarely performed, it requires a more diligent protocol workflow, coordination of caregivers, and education within multiple clinical departments. Choosing the correct imaging exam can be critical, as patients can have significant neuropathy and/or paralysis. The LIMES3 protocol is well liked at our institution, and forms the cornerstone of understanding for our work. Our literature management led to a better clinical protocol creation despite the diffuse and inconclusive information presented in the existing medical literature.

60 APPLIED LIFE SCIENCES↗

Magnetic induced heating of nanoparticle solutions

Magnetic induced heating of nanoparticles (NP) provides a useful advantage for many energy transfer applications. This study aims to gain an understanding of the key parameters responsible for maximizing the energy transfer leading to nanoparticle heating through the use of simulations and experimental results. It was found that magnetic field strength, NP concentration, NP composition, and coil size can be controlled to generate accurate temperature profiles in NP aqueous solutions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Laser beam deflection control: A concept

Improved control of laser beam deflection angles may result from new conceptual device. Reflectively coated magnetized particles are suspended in liquid-filled cell surrounded by two pairs of crossed electromagnetic coils and are selectively aligned by controlling magnetic fields. Ultrasonic energy source keeps particles suspended.

Garvie, C. L.↗

Magnetic simulation of gravity.

Investigation of the feasibility of a magnetically simulated gravity that could make it possible to simulate aircraft jettison processes in a wind tunnel. It is shown that coils capable to produce a thereto suitable magnetic field configuration do exist. Circumstances are defined for which multiple jettison releases may be simulated, and an approximate calculation for the errors due to magnetic field nonuniformities is presented.

Covert, E. E.↗

VLF-emissions from ring current electrons. An interpretation of the band of missing emissions

VLF-emissions associated with the enhancement of ring current electrons during magnetic storms and substorms which were detected by the equatorially orbiting S-A satellite (Explorer 45) are described. The emissions observed near the geomagnetic equator consist of essentially two frequency regimes, i.e., one above the electron gyrofrequency, f sub H at the equator and the other below f sub H. This is indicated as a part of the wide-band data obtained during the main phase of the December 17, 1971 magnetic storm. The upper figure is the ac-magnetic field data measured by the search-coil magnetometer with the upper cutoff of 3kHz and the lower figure is the ac-electric field data obtained by the electric field sensor with the upper cutoff of 10kHz. These figures show the time sequence of the observed emissions along the inbound orbit (No. 101) of the satellite as f sub H changes approximately from 3 kHz at 20 UT to 6 kHz at 21 UT. The emissions above f sub H are electrostatic mode, which peak near the frequencies of (n + 1/2) f sub H where n is positive integer, and sometimes emissions up to n = 10 are observed. The emissions below f sub H are whistler mode, which have a conspicuous gap along exactly half electron gyrofrequency, f sub H/2.

Maeda, K.↗

Magnifying image intensifier

A magnetically focused image intensifier was improved to increase the usable range of magnification without degradation of image quality. The power requirements of the focusing coils are minimal. The arrangement of the focusing coils reverses the direction of the axial magnetic field distribution between the planes of the photocathode and the phosphor screen.

Vine, J.↗

Acoustic/Magnetic Stress Sensor

High-resolution sensor fast, portable, does not require permanent bonding to structure. Sensor measures nondestructively type (compressive or tensile) and magnitude of stresses and stress gradients present in class of materials. Includes precise high-resolution acoustic interferometer, sending acoustic transducer, receiving acoustic transducer, electromagnet coil and core, power supply, and magnetic-field-measuring device such as Hall probe. This measurement especially important for construction and applications where steel is widely used. Sensor useful especially for nondestructive evaluation of stress in steel members because of portability, rapid testing, and nonpermanent installation.

Heyman, J. S.↗

Single-state selection system for hydrogen masers

The design and operation of a single-state selection system based on the adiabatic fast-passage technique for atomic state inversion is described. The system uses a variable-pitch dc solenoid and orthogonal four-wire RF coil to create the state-changing magnetic fields, and a half-wavelength state selection magnet to remove the inverted state atoms from the hydrogen beam. The system's performance was determined by measuring maser power as a function of line Q. The system removes more than 85 percent of undesired atoms from the beam. The potential effects of improvements in the maser on its frequency stability have been calculated. The use of single-state selection combined with increased RF coupling to the cavity and increased storage bulb collimation offers the possibility of frequency stability in the 10 to the -17th regime over intervals on the order of 60,000 s.

Mattison, Edward M.↗