Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A tuning fork based wide range mechanical characterization tool with nanorobotic manipulators inside a scanning electron microscope

This study proposes a tuning fork probe based nanomanipulation robotic system for mechanical characterization of ultraflexible nanostructures under scanning electron microscope. The force gradient is measured via the frequency modulation of a quartz tuning fork and two nanomanipulators are used for manipulation of the nanostructures. Two techniques are proposed for attaching the nanostructure to the tip of the tuning fork probe. The first technique involves gluing the nanostructure for full range characterization whereas the second technique uses van der Waals and electrostatic forces in order to avoid destroying the nanostructure. Helical nanobelts (HNB) are proposed for the demonstration of the setup. The nonlinear stiffness behavior of HNBs during their full range tensile studies is clearly revealed for the first time. Using the first technique, this was between 0.009 N/m for rest position and 0.297 N/m before breaking of the HNB with a resolution of 0.0031 N/m. For the second experiment, this was between 0.014 N/m for rest position and 0.378 N/m before detaching of the HNB with a resolution of 0.0006 N/m. This shows the wide range sensing of the system for potential applications in mechanical property characterization of ultraflexible nanostructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscopic description of large-amplitude shape-mixing dynamics with local QRPA inertial functions

We introduce a microscopic approach to derive all the inertial functions in the five-dimensional quadrupole collective Hamiltonian. Local normal modes are evaluated on the constrained mean field in the quasiparticle random-phase approximation in order to derive the inertial functions. The collective Hamiltonians for neutron-rich Mg isotopes are determined with use of this approach, and the shape coexistence/mixing around the N = 20 region is analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In situ nanomechanical testing in focused ion beam and scanning electron microscopes

The recent interest in size-dependent deformation of micro- and nanoscale materials has paralleled both technological miniaturization and advancements in imaging and small-scale mechanical testing methods. Here we describe a quantitative in situ nanomechanical testing approach adapted to a dual-beam focused ion beam and scanning electron microscope. A transducer based on a three-plate capacitor system is used for high-fidelity force and displacement measurements. Specimen manipulation, transfer, and alignment are performed using a manipulator, independently controlled positioners, and the focused ion beam. Gripping of specimens is achieved using electron-beam assisted Pt-organic deposition. Local strain measurements are obtained using digital image correlation of electron images taken during testing. Examples showing results for tensile testing of single-crystalline metallic nanowires and compression of nanoporous Au pillars will be presented in the context of size effects on mechanical behavior and highlight some of the challenges of conducting nanomechanical testing in vacuum environments.

36 MATERIALS SCIENCE↗

Note: Seesaw actuation of atomic force microscope probes for improved imaging bandwidth and displacement range

The authors describe a method of actuation for atomic force microscope (AFM) probes to improve imaging speed and displacement range simultaneously. Unlike conventional piezoelectric tube actuation, the proposed method involves a lever and fulcrum ''seesaw'' like actuation mechanism that uses a small, fast piezoelectric transducer. The lever arm of the seesaw mechanism increases the apparent displacement range by an adjustable gain factor, overcoming the standard tradeoff between imaging speed and displacement range. Experimental characterization of a cantilever holder implementing the method is provided together with comparative line scans obtained with contact mode imaging. An imaging bandwidth of 30 kHz in air with the current setup was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscopic Description of the Exotic Nuclei Reactions by Using Folding model Potentials

A microscopic folding approach based upon the effective M3Y nucleon-nucleon interaction and the nuclear matter densities of the interacting nuclei has been carried out to explain recently measured experimental data of the {sup 6}He+{sup 120}Sn elastic scattering reaction at four different laboratory energies near the Coulomb barrier. The corresponding reaction cross sections are also considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlation between resistance-change effect in transition-metal oxides and secondary-electron contrast of scanning electron microscope images

Conductive atomic-force microscopy (C-AFM) writing is attracting attention as a technique for clarifying the switching mechanism of resistive random-access memory by providing a wide area filled with filaments, which can be regarded as one filament with large radius. The writing area on a nickel-oxide (NiO) film formed by conductive atomic-force microscopy was observed by scanning electron microscope, and a correlation between the contrast in a secondary-electron image (SEI) and the resistance written by C-AFM was revealed. In addition, the dependence of the SEI contrast on the beam accelerating voltage (V{sub accel}) suggests that the resistance-change effect occurs near the surface of the NiO film. As for the effects of electron irradiation and vacuum annealing on the C-AFM writing area, it was shown that the resistance-change effect is caused by exchange of oxygen with the atmosphere at the surface of the NiO film. This result suggests that the low-resistance and high-resistance areas are, respectively, p-type Ni{sub 1+{delta}}O ({delta} < 0) and insulating (stoichiometric) or n-type Ni{sub 1+{delta}}O ({delta}{>=} 0).

36 MATERIALS SCIENCE↗

Non-destructive observation of in-grown stacking faults in 4H-SiC epitaxial layer using mirror electron microscope

Mirror electron microscope (MEM) observation has been conducted for a 4-{mu}m-thick n-doped 4H-SiC epitaxial layer. If the sample is simultaneously illuminated with ultraviolet (UV) light of a slightly greater energy than the bandgap energy of 4H-SiC, in-grown stacking faults (IGSFs) can be clearly observed in MEM images. These observations were performed non-destructively, as almost all irradiated electrons returned without impinging the sample surface due to the negative voltage applied to the sample. High spatial resolution observation via MEM showed that multiple IGSFs were stacked up. The phenomenon in which the contrast of the IGSFs vanished in the absence of UV illumination and under UV illumination with a lower energy than the bandgap energy revealed that the origin of the contrast was the negative charging of IGSFs trapping electrons excited by UV light.

36 MATERIALS SCIENCE↗

Scanning photoelectron microscope for nanoscale three-dimensional spatial-resolved electron spectroscopy for chemical analysis

In order to achieve nondestructive observation of the three-dimensional spatially resolved electronic structure of solids, we have developed a scanning photoelectron microscope system with the capability of depth profiling in electron spectroscopy for chemical analysis (ESCA). We call this system 3D nano-ESCA. For focusing the x-ray, a Fresnel zone plate with a diameter of 200 {mu}m and an outermost zone width of 35 nm is used. In order to obtain the angular dependence of the photoelectron spectra for the depth-profile analysis without rotating the sample, we adopted a modified VG Scienta R3000 analyzer with an acceptance angle of 60 deg. as a high-resolution angle-resolved electron spectrometer. The system has been installed at the University-of-Tokyo Materials Science Outstation beamline, BL07LSU, at SPring-8. From the results of the line-scan profiles of the poly-Si/high-k gate patterns, we achieved a total spatial resolution better than 70 nm. The capability of our system for pinpoint depth-profile analysis and high-resolution chemical state analysis is demonstrated.

36 MATERIALS SCIENCE↗

Scanning tunneling microscopic studies of laser-induced modifications of Si(001)-(2 x 1) surface

Scanning tunneling microscopic studies of Si(001)-2 x 1 surfaces excited with 532-nm laser pulses of intensities below melting and ablation thresholds have revealed two different modes of structural modifications, strongly depending on the intensity of laser lights. The excitation below 100 mJ/cm{sup 2} causes bond rupture at individual dimer-sites leading to the formation of vacancies selectively on the outermost layer. The bond rupture, which shows a strongly site-sensitive rate, forms efficiently vacancy-strings elongated along the surface dimer-rows. Selective removal of surface dimers results in the exposure of flat and defect-less underlying layer as reported previously, which is resistive to the excitation at this range of intensity. At intensities above 100 mJ/cm{sup 2}, on the other hand, the excitation forms not only vacancies but also ad-dimers on terraces. The number density of ad-dimers is in proportion to the square of that for vacancies, indicating strongly that silicon atoms released by laser-induced bond rupture are associated with each other to form ad-dimers. The repeated irradiations at this range of intensities induce anisotropic growth of ad-dimer islands and of vacancy clusters on terrace regions, leading to multiply terraced structure. The primary processes of the structural modifications are discussed based on the quantitative analyses of the growth of vacancy and ad-dimer under excitation.

36 MATERIALS SCIENCE↗

Microscopic calculations of Qp-values in well-deformed odd-Z proton emitters

Within the Hartree-Fock-BCS and Highly Truncated Diagonalization microscopic approaches we have calculated the ground-state binding energies of axially-deformed odd-Z, even-N nuclei in the A {approx} 130 region and of the even-even daughter nuclei resulting from one-proton emission. The deduced Q{sub p} values are in fair agreement with available experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of thermal and acoustic noise interferences in low stiffness atomic force microscope cantilevers and characterization of their dynamic properties

The atomic force microscope (AFM) is a powerful tool for the measurement of forces at the micro/nano scale when calibrated cantilevers are used. Besides many existing calibration techniques, the thermal calibration is one of the simplest and fastest methods for the dynamic characterization of an AFM cantilever. This method is efficient provided that the Brownian motion (thermal noise) is the most important source of excitation during the calibration process. Otherwise, the value of spring constant is underestimated. This paper investigates noise interference ranges in low stiffness AFM cantilevers taking into account thermal fluctuations and acoustic pressures as two main sources of noise. As a result, a preliminary knowledge about the conditions in which thermal fluctuations and acoustic pressures have closely the same effect on the AFM cantilever (noise interference) is provided with both theoretical and experimental arguments. Consequently, beyond the noise interference range, commercial low stiffness AFM cantilevers are calibrated in two ways: using the thermal noise (in a wide temperature range) and acoustic pressures generated by a loudspeaker. We then demonstrate that acoustic noises can also be used for an efficient characterization and calibration of low stiffness AFM cantilevers. The accuracy of the acoustic characterization is evaluated by comparison with results from the thermal calibration.

36 MATERIALS SCIENCE↗

Nanosecond in situ transmission electron microscope studies of the reversible Ge{sub 2}Sb{sub 2}Te{sub 5} crystalline <==> amorphous phase transformation

Chalcogenide-based phase-change materials have wide use in optical recording media and are growing in importance for use in non-volatile electronic memory. For both applications, rapid switching between the amorphous and crystalline phases is necessary, and understanding the changes during rapidly driven phase transitions is of scientific and technological significance. Laser-induced crystallization and amorphization occur rapidly and changes in atomic structure, microstructure, and temperature are difficult to observe experimentally and determine computationally. We have used nanosecond-scale time-resolved diffraction with intense electron pulses to study Ge{sub 2}Sb{sub 2}Te{sub 5} during laser crystallization. Using a unique and unconventional specimen geometry, cycling between the amorphous and crystalline phases was achieved, enabling in situ transmission electron microscope (TEM) study of both microstructural and crystallographic changes caused by repeated switching. Finite element analysis was used to simulate interactions of the laser with the nano-structured specimens and to model the rapidly changing specimen temperature. Such time-resolved experimental methods combined with simulation of experimentally inaccessible physical characteristics will be fundamental to advancing the understanding of rapidly driven phase transformations.

36 MATERIALS SCIENCE↗

The long range voice coil atomic force microscope

Most current atomic force microscopes (AFMs) use piezoelectric ceramics for scan actuation. Piezoelectric ceramics provide precision motion with fast response to applied voltage potential. A drawback to piezoelectric ceramics is their inherently limited ranges. For many samples this is a nonissue, as imaging the nanoscale details is the goal. However, a key advantage of AFM over other microscopy techniques is its ability to image biological samples in aqueous buffer. Many biological specimens have topography for which the range of piezoactuated stages is limiting, a notable example of which is bone. In this article, we present the use of voice coils in scan actuation for an actuation range in the Z-axis an order of magnitude larger than any AFM commercially available today. The increased scan size will allow for imaging an important new variety of samples, including bone fractures.

36 MATERIALS SCIENCE↗

Microscopic probing of the size dependence in hydrophobic solvation

We report small angle x-ray scattering data demonstrating the direct experimental microscopic observation of the small-to-large crossover behavior of hydrophobic effects in hydrophobic solvation. By increasing the side chain length of amphiphilic tetraalkyl-ammonium (C{sub n}H{sub 2n+1}){sub 4}N{sup +} (R{sub 4}N{sup +}) cations in aqueous solution we observe diffraction peaks indicating association between cations at a solute size between 4.4 and 5 A, which show temperature dependence dominated by hydrophobic attraction. Using O K-edge x-ray absorption we show that small solutes affect hydrogen bonding in water similar to a temperature decrease, while large solutes affect water similar to a temperature increase. Molecular dynamics simulations support, and provide further insight into, the origin of the experimental observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative comparison of two independent lateral force calibration techniques for the atomic force microscope

Two independent lateral-force calibration methods for the atomic force microscope (AFM)--the hammerhead (HH) technique and the diamagnetic lateral force calibrator (D-LFC)--are systematically compared and found to agree to within 5% or less, but with precision limited to about 15%, using four different tee-shaped HH reference probes. The limitations of each method, both of which offer independent yet feasible paths toward traceable accuracy, are discussed and investigated. We find that stiff cantilevers may produce inconsistent D-LFC values through the application of excessively high normal loads. In addition, D-LFC results vary when the method is implemented using different modes of AFM feedback control, constant height and constant force modes, where the latter is more consistent with the HH method and closer to typical experimental conditions. Specifically, for the D-LFC apparatus used here, calibration in constant height mode introduced errors up to 14 %. In constant force mode using a relatively stiff cantilever, we observed an {approx_equal} 4 % systematic error per {mu}N of applied load for loads {<=} 1 {mu}N. The issue of excessive load typically emerges for cantilevers whose flexural spring constant is large compared with the normal spring constant of the D-LFC setup (such that relatively small cantilever flexural displacements produce relatively large loads). Overall, the HH method carries a larger uncertainty, which is dominated by uncertainty in measurement of the flexural spring constant of the HH cantilever as well as in the effective length dimension of the cantilever probe. The D-LFC method relies on fewer parameters and thus has fewer uncertainties associated with it. We thus show that it is the preferred method of the two, as long as care is taken to perform the calibration in constant force mode with low applied loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A pressure gauge based on gas density measurement from analysis of the thermal noise of an atomic force microscope cantilever

We describe a gas-density gauge based on the analysis of the thermally-driven fluctuations of an atomic force microscope (AFM) cantilever. The fluctuations are modeled as a ring-down of a simple harmonic oscillator, which allows fitting of the resonance frequency and damping of the cantilever, which in turn yields the gas density. The pressure is obtained from the density using the known equation of state. In the range 10-220 kPa, the pressure readings from the cantilever gauge deviate by an average of only about 5% from pressure readings on a commercial gauge. The theoretical description we use to determine the pressure from the cantilever motion is based upon the continuum hypothesis, which sets a minimum pressure for our analysis. It is anticipated that the cantilever gauge could be extended to measure lower pressures given a molecular theoretical description. Alternatively, the gauge could be calibrated for use in the non-continuum range. Our measurement technique is similar to previous AFM cantilever measurements, but the analysis produces improved accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Macroscopic and microscopic defects and nonlinear optical properties of KH{sub 2}PO{sub 4} crystals with embedded TiO{sub 2} nanoparticles

Results from the successful growth of high quality KH{sub 2}PO{sub 4} (KDP) crystals with incorporated TiO{sub 2} anatase nanoparticles and the characterization of these crystals using several complementary methods are presented. The study allowed the nature and distribution of macroscopic and microscopic defects in the KDP:TiO{sub 2} crystals to be clarified. The relationship between these defects and the distribution of TiO{sub 2} nanoparticles, and the influence of incorporated nanoparticles on the nonlinear optical properties of composite crystals in comparison with pure crystals were also elucidated. Visual observations, transmission and scanning electron microscopy have shown that the anatase nanoparticles were captured mainly by the pyramidal growth sector and, to a considerably lesser extent, by the prismatic growth sector. Energy dispersive x-ray analysis was able to confirm that the growth layer stacks contain the TiO{sub 2} particles. Fourier transformation infrared spectra have clearly shown the presence of an absorption band at about 800 cm{sup -1} in both KDP:TiO{sub 2} and TiO{sub 2}, and the disappearance of the band, associated with hydroxyl OH{sup -} groups on the TiO{sub 2} surface in KDP:TiO{sub 2}. Significant variation in the imaginary and real parts of the cubic nonlinear optical susceptibilities and refractive index changes at continuous wave excitation were found in prism and pyramid parts of pure KDP and KDP:TiO{sub 2} samples. Deciphering complicated electron paramagnetic resonance spectra in KDP:TiO{sub 2} and comparison with published data permitted the identification of paramagnetic defects along with their associated g-factors and zero-field splitting parameters (in some cases for the first time). It was found that the dominant lines belong to four different centers Fe{sub A}{sup 3+}, Fe{sub B}{sup 3+}, Cr{sub R}{sup 3+}, and Cr{sub GB}{sup 3+}. From analysis of line intensities it was concluded that the concentration of intrinsic defects like potassium and hydrogen vacancies in KDP:TiO{sub 2} is comparatively small, that the concentration of non-controlled impurities in nominally pure KDP samples is several times larger than in KDP:TiO{sub 2}, and that the concentration of non-controlled impurities in the prismatic part of the KDP:TiO{sub 2} boule is approximately twice as large as in the pyramid part.

36 MATERIALS SCIENCE↗

Compact Kirkpatrick–Baez microscope mirrors for imaging laser-plasma x-ray emission

Compact Kirkpatrick–Baez microscope mirror components for use in imaging laser-plasma x-ray emission have been manufactured, coated, and tested. A single mirror pair has dimensions of 14 × 7 × 9 mm and a best resolution of ~5 μm. The mirrors are coated with Ir providing a useful energy range of 2-8 keV when operated at a grazing angle of 0.7°. The mirrors can be circularly arranged to provide 16 images of the target emission a configuration best suited for use in combination with a custom framing camera. As a result, an alternative arrangement of the mirrors would allow alignment of the images with a fourstrip framing camera.

47 OTHER INSTRUMENTATION↗