Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Deflection of a monochromatic THz beam by acousto-optic methods

The possibility of controlled deflection of an electromagnetic THz beam of a free-electron laser by acousto-optic (AO) methods has been demonstrated for the first time. The material of the AO deflector was chosen to be single-crystal germanium, which has a fairly large refractive index (n = 4.0) and a relatively low absorption coefficient for electromagnetic waves. The absorption coefficient α in germanium is 0.75 ± 0.02 cm{sup -1} at a wavelength λ = 140 μm. The diffracted beam intensity is shown to be maximum at an effective AO interaction length l = 1/α. A diffraction efficiency of 0.05% at a travelling acoustic wave power of 1.0 W is experimentally obtained. It is established that a change in the ultrasonic frequency from 25 to 39 MHz leads to variation in the external Bragg angle in the range from 19.5° to 27.5°. At a fixed Bragg angle θ{sub B} = 22.4° the frequency band of diffraction is 4.2 ± 0.1 MHz and the angular range of laser beam scanning reaches 2.5° ± 0.5°. The results obtained indicate that AO interaction can be used for controlled deflection of electromagnetic THz beams. (terahertz radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-329: Dosimetric Impact of Implementing Metal Artifact Reduction Methods and Metal Energy Deposition Kernels for Photon Dose Calculations

Purpose: To investigate two strategies for reducing dose calculation errors near metal implants: use of CT metal artifact reduction methods and implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) method. Methods: Radiochromic film was used to measure the dose upstream and downstream of titanium and Cerrobend implants. To assess the dosimetric impact of metal artifact reduction methods, dose calculations were performed using baseline, uncorrected images and metal artifact reduction Methods: Philips O-MAR, GE’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI imaging with metal artifact reduction software applied (MARs).To assess the impact of metal kernels, titanium and silver kernels were implemented into a commercial collapsed cone C/S algorithm. Results: The CT artifact reduction methods were more successful for titanium than Cerrobend. Interestingly, for beams traversing the metal implant, we found that errors in the dimensions of the metal in the CT images were more important for dose calculation accuracy than reduction of imaging artifacts. The MARs algorithm caused a distortion in the shape of the titanium implant that substantially worsened the calculation accuracy. In comparison to water kernel dose calculations, metal kernels resulted in better modeling of the increased backscatter dose at the upstream interface but decreased accuracy directly downstream of the metal. We also found that the success of metal kernels was dependent on dose grid size, with smaller calculation voxels giving better accuracy. Conclusion: Our study yielded mixed results, with neither the metal artifact reduction methods nor the metal kernels being globally effective at improving dose calculation accuracy. However, some successes were observed. The MARs algorithm decreased errors downstream of Cerrobend by a factor of two, and metal kernels resulted in more accurate backscatter dose upstream of metals. Thus, these two strategies do have the potential to improve accuracy for patients with metal implants in certain scenarios. This work was supported by Public Health Service grants CA 180803 and CA 10953 awarded by the National Cancer Institute, United States of Health and Human Services, and in part by Mobius Medical Systems.

60 APPLIED LIFE SCIENCES↗

Polarimetric performance of a Laue lens gamma-ray CdZnTe focal plane prototype

A gamma-ray telescope mission concept [gamma ray imager (GRI)] based on Laue focusing techniques has been proposed in reply to the European Space Agency call for mission ideas within the framework of the next decade planning (Cosmic Vision 2015-2025). In order to optimize the design of a focal plane for this satellite mission, a CdZnTe detector prototype has been tested at the European Synchrotron Radiation Facility under an {approx}100% polarized gamma-ray beam. The spectroscopic, imaging, and timing performances were studied and in particular its potential as a polarimeter was evaluated. Polarization has been recognized as being a very important observational parameter in high energy astrophysics (>100 keV) and therefore this capability has been specifically included as part of the GRI mission proposal. The prototype detector tested was a 5 mm thick CdZnTe array with an 11x11 active pixel matrix (pixel area of 2.5x2.5 mm{sup 2}). The detector was irradiated by a monochromatic linearly polarized beam with a spot diameter of about 0.5 mm over the energy range between 150 and 750 keV. Polarimetric Q factors of 0.35 and double event relative detection efficiency of 20% were obtained. Further measurements were performed with a copper Laue monochromator crystal placed between the beam and the detector prototype. In this configuration we have demonstrated that a polarized beam does not change its polarization level and direction after undergoing a small angle (<1 deg.) Laue diffraction inside a crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monochromatic plane-fronted waves in conformal gravity are pure gauge

We consider plane-fronted, monochromatic gravitational waves on a Minkowski background, in a conformally invariant theory of general relativity. By this we mean waves of the form: g{sup {mu}{nu}}={eta}{sup {mu}{nu}}+{epsilon}{sup {mu}{nu}}F(k{center_dot}x), where {epsilon}{sup {mu}{nu}} is a constant polarization tensor, and k{sub {mu}} is a lightlike vector. We also assume the coordinate gauge condition |g|{sup -1/4}{partial_derivative}{sub {tau}}(|g|{sup 1/4}g{sup {sigma}{tau}})=0 which is the conformal analog of the harmonic gauge condition g{sup {mu}{nu}}{Gamma}{sub {mu}{nu}}{sup {sigma}}=-|g|{sup -1/2}{partial_derivative}{sub {tau}}(|g|{sup 1/2}g{sup {sigma}{tau}})=0, where det{open_square}[g{sub {mu}{nu}}]{identical_to}g. Requiring additionally the conformal gauge condition g=-1 surprisingly implies that the waves are both transverse and traceless. Although the ansatz for the metric is eminently reasonable when considering perturbative gravitational waves, we show that the metric is reducible to the metric of Minkowski space-time via a sequence of coordinate transformations which respect the gauge conditions, without any perturbative approximation that {epsilon}{sup {mu}{nu}} be small. This implies that we have, in fact, exact plane-wave solutions; however, they are simply coordinate/conformal artifacts. As a consequence, they carry no energy. Our result does not imply that conformal gravity does not have gravitational wave phenomena. A different, more generalized ansatz for the deviation, taking into account the fourth-order nature of the field equation, which has the form g{sup {mu}{nu}}={eta}{sup {mu}{nu}}+B{sup {mu}{nu}}(n{center_dot}x)G(k{center_dot}x), indeed yields waves which carry energy and momentum [P. D. Mannheim, Gen. Relativ. Gravit. 43, 703 (2010)]. It is just surprising that transverse, traceless, plane-fronted gravitational waves, those that would be used in any standard, perturbative, quantum analysis of the theory, simply do not exist.

79 ASTRONOMY AND ASTROPHYSICS↗

Monitoring microstructural evolution in irradiated steel with second harmonic generation

Material damage in structural components is driven by microstructural evolution that occurs at low length scales and begins early in component life. In metals, these microstructural features are known to cause measurable changes in the acoustic nonlinearity parameter. Physically, the interaction of a monochromatic ultrasonic wave with microstructural features such as dislocations, precipitates, and vacancies, generates a second harmonic wave that is proportional to the acoustic nonlinearity parameter. These nonlinear ultrasonic techniques thus have the capability to evaluate initial material damage, particularly before crack initiation and propagation occur. This paper discusses how the nonlinear ultrasonic technique of second harmonic generation can be used as a nondestructive evaluation tool to monitor microstructural changes in steel, focusing on characterizing neutron radiation embrittlement in nuclear reactor pressure vessel steels. Current experimental evidence and analytical models linking microstructural evolution with changes in the acoustic nonlinearity parameter are summarized.

36 MATERIALS SCIENCE↗

Three-Dimensional Wigner-Function Description of the Quantum Free-Electron Laser

A free-electron laser (FEL) operating in the quantum regime can provide a compact and monochromatic x-ray source. Here we present the complete quantum model for a FEL with a laser wiggler in three spatial dimensions, based on a discrete Wigner-function formalism taking into account the longitudinal momentum quantization. The model describes the complete spatial and temporal evolution of the electron and radiation beams, including diffraction, propagation, laser wiggler profile and emittance effects. The transverse motion is described in a suitable classical limit, since the typical beam emittance values are much larger than the Compton wavelength quantum limit. In this approximation we derive an equation for the Wigner function which reduces to the three-dimensional Vlasov equation in the complete classical limit. Preliminary numerical results are presented together with parameters for a possible experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin-flip M1 strengths in {sup 208}Pb

Spin-flip M1 strength in {sup 208}Pb has been measured in photon scattering experiments with a quasi-monochromatic, linearly polarized photon beam. The data resolve an M1 giant resonance into at least seven, possibly eight, discrete transitions at energies between 7.1 and 7.4 MeV below the neutron separation energy. The measured M1 strength in this region is found to be larger than the previous report. By comparing the data with a self-consistent RPA estimation using a semi-realistic interaction, a role of the tensor force is reconfirmed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multilepton signatures of a hidden sector in rare B decays

We explore the sensitivity of flavor-changing b{yields}s transitions to a (sub-) GeV hidden sector with generic couplings to the standard model through the Higgs, vector, and axion portals. The underlying two-body decays of B mesons, B{yields}X{sub s}S, and B{sup 0}{yields}SS, where S denotes a generic new GeV-scale particle, may significantly enhance the yield of monochromatic lepton pairs in the final state via prompt S{yields}ll decays. Existing measurements of the charged lepton spectrum in neutral-current semileptonic B decays provide bounds on the parameters of the light sector that are significantly more stringent than the requirements of naturalness. New search modes, such as B{yields}X{sub s}+n(ll) and B{sup 0}{yields}n(ll) with n{>=}2, can provide additional sensitivity to scenarios in which both the Higgs and vector portals are active, and are accessible to (super-) B factories and hadron colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A DISK-WIND MODEL FOR THE NEAR-INFRARED EXCESS EMISSION IN PROTOSTARS

Protostellar systems, ranging from low-luminosity classical T Tauri and Herbig Ae stars to high-luminosity Herbig Be stars, exhibit a near-infrared (NIR) excess in their spectra that is dominated by a bump in the monochromatic luminosity with a peak near 3 {mu}m. The bump can be approximated by a thermal emission component of temperature {approx}1500 K that is of the order of the sublimation temperature of interstellar dust grains. In the currently popular 'puffed-up rim' scenario, the bump represents stellar radiation that propagates through the optically thin inner region of the surrounding accretion disk and is absorbed and reemitted by the dust that resides just beyond the dust sublimation radius r {sub sub}. However, this model cannot account for the strongest bumps measured in these sources, and it predicts a pronounced secondary bounce in the interferometric visibility curve that is not observed. In this paper we present an alternative interpretation, which attributes the bump to reemission of stellar radiation by dust that is uplifted from the disk by a centrifugally driven wind. Winds of this type are a leading candidate for the origin of the strong outflows associated with protostars, and there is observational evidence for disk winds originating on scales {approx}r {sub sub}. Using a newly constructed Monte Carlo radiative transfer code and focusing on low-luminosity sources, we show that this model can account for the NIR excess emission even in bright Herbig Ae stars such as AB Auriga and MWC 275, and that it successfully reproduces the basic features of the visibilities measured in these protostars. We argue that a robust dusty outflow in these sources could be self-limiting-through shielding of the stellar FUV photons-to a relatively narrow launching region between r {sub sub} and {approx}2 r {sub sub}. We also suggest that the NIR and scattered-light variability exhibited by a source like MWC 275 can be attributed in this picture to the uplifting of dust clouds from the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance and Application of FEL and PXR Sources at Nihon University

The infrared free electron laser (FEL) and the parametric X-ray radiation (PXR) developed on the basis of the 125 MeV electron linac at Nihon University have been applied to studies in a variety of scientific fields. Primary users so far are the faculty members in the university, approximately 2000 hr/year of the machine time having been dedicated to the experiments since 2004. Currently the wavelength range of the FEL served for users' experiments covers 1500 to 6000 nm at the optical power level of 10 to 30 mJ/macropulse. Combination of the fundamental infrared FEL with BBO non-linear optical crystals yielded higher harmonics with good conversion efficiencies, which has extended the available wavelength range as short as approximately 400 nm. The PXR generator has employed a double-crystal system so that the monochromatic X-ray beam is available at a fixed output port independently of the X-ray center energy. By using a Si(111) crystal as the PXR target the energy variable monochromatic X-ray beam from 5 to 20 keV has been successfully applied to users' experiments. The latest work on the PXR generation using a Si(220) target crystal has demonstrated availability of the X-ray beam with energies up to approximately 34 keV.

43 PARTICLE ACCELERATORS↗

Monochromatic radiography of high energy density physics experiments on the MAGPIE generator

A monochromatic X-ray backlighter based on Bragg reflection from a spherically bent quartz crystal has been developed for the MAGPIE pulsed power generator at Imperial College (1.4 MA, 240 ns) [I. H. Mitchell et al., Rev. Sci. Instrum. 67, 1533 (2005)]. This instrument has been used to diagnose high energy density physics experiments with 1.865 keV radiation (Silicon He-α) from a laser plasma source driven by a ∼7 J, 1 ns pulse from the Cerberus laser. The design of the diagnostic, its characterisation and performance, and initial results in which the instrument was used to radiograph a shock physics experiment on MAGPIE are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonproportional scintillation response of NaI:Tl to low energy x-ray photons and electrons

Nonproportional response of the scintillation yield of NaI:Tl was measured using highly monochromatic synchrotron irradiation ranging from 9-100 keV. Special attention is paid to the x-ray escape peaks. They provide us additional information about photon response in the range 0.9-12 keV. A rapid variation in the photon response curve is observed near the iodine K-electron binding energy. A dense sampling of data is performed around this energy and that data are used to apply a method, which we call K-dip spectroscopy. This method allows us to derive the electron response curve of NaI:Tl down to energies as low as 30 eV. A comparison of our data with data of others employing different methods is made. Advantages, limitations, and peculiarities of presented techniques and methods are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of electron density in dual-energy x-ray CT with monochromatic x rays and evaluation of its accuracy

Information on electron density is important for radiotherapy treatment planning in order to optimize the dose distribution in the target volume of a patient. At present, the electron density is derived from a computed tomography (CT) number measured in x-ray CT scanning; however, there are uncertainties due to the beam hardening effect and the method by which the electron density is converted from the CT number. In order to measure the electron density with an accuracy of {+-}1%, the authors have developed dual-energy x ray CT using monochromatic x rays. They experimentally proved that the measured linear attenuation coefficients were only a few percent lower than the theoretical ones, which led to an accuracy within 2% for the electron density. There were three factors causing inaccuracy in the linear attenuation coefficient and the electron density: the influence of scattered radiation, the nonlinearity in the detector response function, and a theoretical process to derive the electron density from the linear attenuation coefficients. The linear attenuation coefficients of water were experimentally proved to differ by 1%-2% from the theoretical one even when the scattering effect was negligible. The nonlinearity of the response function played an important role in correcting the difference in the linear attenuation coefficient. Furthermore, the theoretical process used for deriving the electron density from the linear attenuation coefficients introduces about 0.6% deviation from the theoretical value into the resultant electron density. This deviation occurs systematically so that it can be corrected. The authors measured the electron densities for seven samples equivalent to soft tissue in dual-energy x-ray CT, and finally obtained them with an accuracy of around {+-}1%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of the host composition on the lifetime decay properties of barium/strontium aluminates compounds

This paper reports the influence of the structural change on the luminescence of Eu-doped barium/strontium aluminates when excited with monochromatic X-rays (also known as X-ray excited optical luminescence—XEOL). Ba{sub 1−x}Sr{sub x}Al{sub 2}O{sub 4} samples, with 0 < x < 1, were produced via proteic sol-gel route and it was observed that the XEOL emission spectra are composed by the Eu{sup 2+} and Eu{sup 3+} transitions, although no Eu{sup 2+} was observed in the X-ray absorption spectra. The XEOL intensities while the sample is under irradiation decreased as a function of the irradiation time, indicating the buildup of radiation damage. The saturation level of the XEOL is directly correlated to the amount of damages induced by the irradiation and the sample composition. The Ba-rich samples are the ones with higher XEOL yield. X-ray induced long lasting phosphorescence (LLP) was also observed for all samples and it was found that the duration of the phosphorescence emission also depends on the sample composition. In Sr-rich samples, the LLP has a slower decay time constant than in Ba-rich samples. A model of the radiation induced luminescence is presented and all these features are discussed in terms of the energetic costs and the type of defects generated in the sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Environmentally selected WIMP dark matter with high-scale supersymmetry breaking

We explore the possibility that both the weak scale and the thermal relic dark matter abundance are environmentally selected in a multiverse. An underlying supersymmetric theory containing the states of the minimal supersymmetric standard model (MSSM) and singlets, with supersymmetry and R symmetry broken at unified scales, has just two realistic low-energy effective theories. One theory (SM+w-tilde) is the standard model augmented only by the wino, having a mass near 3 TeV, and has a Higgs boson mass in the range of (127-142) GeV. The other theory (SM+h-tilde/s-tilde) has Higgsinos and a singlino added to the standard model. The Higgs boson mass depends on the single new Yukawa coupling of the theory, y, and is near 141 GeV for small y but grows to be as large as 210 GeV as this new coupling approaches strong coupling at high energies. Much of the parameter space of this theory will be probed by direct detection searches for dark matter that push 2 orders of magnitude below the present bounds; furthermore, the dark matter mass and cross section on nucleons are correlated with the Higgs boson mass. The indirect detection signal of monochromatic photons from the Galactic center is computed, and the range of parameters that may be accessible to LHC searches for trilepton events is explored. Taking a broader view, allowing the possibility of R symmetry protection to the TeV scale or axion dark matter, we find four more theories: (SM+axion), two versions of split supersymmetry, and the E-MSSM, where a little supersymmetric hierarchy is predicted. The special Higgs mass value of (141{+-}2) GeV appears in symmetry limits of three of the six theories, (SM+axion), (SM+w-tilde), and (SM+h-tilde/s-tilde), motivating a comparison of other signals of these three theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematic Study of EC Decays in the {sup 146}Gd Region Relevant for a Monoenergetic Neutrino Beam Facility

The availability of a monochromatic neutrino source with adjustable energy could be an invaluable tool for the study of neutrino oscillations and related phenomena. We have studied the beta decay of {sup 152}Yb, {sup 150}Er and {sup 156}Yb, which could be possible candidate nuclei for the construction of such facility, using the Total Absorption Gamma Spectroscopy (TAGS) technique. The results from these measurements are compared with High Resolution (HR) data available from databases. The importance of the use of the TAGS technique is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of TG-61 dose for synchrotron-produced monochromatic x-ray beams using fluence-normalized MCNP5 calculations

Purpose: Ion chamber dosimetry is being used to calibrate dose for cell irradiations designed to investigate photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. This study performed a dosimetry intercomparison for synchrotron-produced monochromatic x-ray beams at 25 and 35 keV. Ion chamber depth-dose measurements in a polymethylmethacrylate (PMMA) phantom were compared with the product of MCNP5 Monte Carlo calculations of dose per fluence and measured incident fluence. Methods: Monochromatic beams of 25 and 35 keV were generated on the tomography beamline at CAMD. A cylindrical, air-equivalent ion chamber was used to measure the ionization created in a 10 Multiplication-Sign 10 Multiplication-Sign 10-cm{sup 3} PMMA phantom for depths from 0.6 to 7.7 cm. The American Association of Physicists in Medicine TG-61 protocol was applied to convert measured ionization into dose. Photon fluence was determined using a NaI detector to make scattering measurements of the beam from a thin polyethylene target at angles 30 Degree-Sign -60 Degree-Sign . Differential Compton and Rayleigh scattering cross sections obtained from xraylib, an ANSI C library for x-ray-matter interactions, were applied to derive the incident fluence. MCNP5 simulations of the irradiation geometry provided the dose deposition per photon fluence as a function of depth in the phantom. Results: At 25 keV the fluence-normalized MCNP5 dose overestimated the ion-chamber measured dose by an average of 7.2 {+-} 3.0%-2.1 {+-} 3.0% for PMMA depths from 0.6 to 7.7 cm, respectively. At 35 keV the fluence-normalized MCNP5 dose underestimated the ion-chamber measured dose by an average of 1.0 {+-} 3.4%-2.5 {+-} 3.4%, respectively. Conclusions: These results showed that TG-61 ion chamber dosimetry, used to calibrate dose output for cell irradiations, agreed with fluence-normalized MCNP5 calculations to within approximately 7% and 3% at 25 and 35 keV, respectively.

60 APPLIED LIFE SCIENCES↗

An adaptive regularization parameter choice strategy for multispectral bioluminescence tomography

Purpose: Bioluminescence tomography (BLT) provides an effective tool for monitoring physiological and pathological activities in vivo. However, the measured data in bioluminescence imaging are corrupted by noise. Therefore, regularization methods are commonly used to find a regularized solution. Nevertheless, for the quality of the reconstructed bioluminescent source obtained by regularization methods, the choice of the regularization parameters is crucial. To date, the selection of regularization parameters remains challenging. With regards to the above problems, the authors proposed a BLT reconstruction algorithm with an adaptive parameter choice rule. Methods: The proposed reconstruction algorithm uses a diffusion equation for modeling the bioluminescent photon transport. The diffusion equation is solved with a finite element method. Computed tomography (CT) images provide anatomical information regarding the geometry of the small animal and its internal organs. To reduce the ill-posedness of BLT, spectral information and the optimal permissible source region are employed. Then, the relationship between the unknown source distribution and multiview and multispectral boundary measurements is established based on the finite element method and the optimal permissible source region. Since the measured data are noisy, the BLT reconstruction is formulated as l{sub 2} data fidelity and a general regularization term. When choosing the regularization parameters for BLT, an efficient model function approach is proposed, which does not require knowledge of the noise level. This approach only requests the computation of the residual and regularized solution norm. With this knowledge, we construct the model function to approximate the objective function, and the regularization parameter is updated iteratively. Results: First, the micro-CT based mouse phantom was used for simulation verification. Simulation experiments were used to illustrate why multispectral data were used rather than monochromatic data. Furthermore, the study conducted using an adaptive regularization parameter demonstrated our ability to accurately localize the bioluminescent source. With the adaptively estimated regularization parameter, the reconstructed center position of the source was (20.37, 31.05, 12.95) mm, and the distance to the real source was 0.63 mm. The results of the dual-source experiments further showed that our algorithm could localize the bioluminescent sources accurately. The authors then presented experimental evidence that the proposed algorithm exhibited its calculated efficiency over the heuristic method. The effectiveness of the new algorithm was also confirmed by comparing it with the L-curve method. Furthermore, various initial speculations regarding the regularization parameter were used to illustrate the convergence of our algorithm. Finally, in vivo mouse experiment further illustrates the effectiveness of the proposed algorithm. Conclusions: Utilizing numerical, physical phantom and in vivo examples, we demonstrated that the bioluminescent sources could be reconstructed accurately with automatic regularization parameters. The proposed algorithm exhibited superior performance than both the heuristic regularization parameter choice method and L-curve method based on the computational speed and localization error.

61 RADIATION PROTECTION AND DOSIMETRY↗