Search NASA⌕ Search

SEARCH · Search NASA

Results for “Match Machining”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

SU-E-T-659: Quantitative Evaluation of Patient Setup Accuracy of Stereotactic Radiotherapy with the Frameless 6D-ExacTrac System Using Statistical Modeling

Purpose: To evaluate patient setup accuracy and quantify individual and cumulative positioning uncertainties associated with different hardware and software components of the stereotactic radiotherapy (SRS/SRT) with the frameless-6D-ExacTrac system. Methods: A statistical model was used to evaluate positioning uncertainties of the different components of SRS/SRT treatment with the BrainLAB 6D-ExacTrac system using the positioning shifts of 35 patients having cranial lesions (49 total lesions treated in 1, 3, 5 fractions). All these patients were immobilized with rigid head-and-neck masks, simulated with BrainLAB-localizer and planned with iPlan treatment planning system. Infrared imaging (IR) was used initially to setup patients. Then, stereoscopic x-ray images (XC) were acquired and registered to corresponding digitally-reconstructed-radiographs using bony-anatomy matching to calculate 6D-translational and rotational shifts. When the shifts were within tolerance (0.7mm and 1°), treatment was initiated. Otherwise corrections were applied and additional x-rays were acquired (XV) to verify that patient position was within tolerance. Results: The uncertainties from the mask, localizer, IR-frame, x-ray imaging, MV and kV isocentricity were quantified individually. Mask uncertainty (Translational: Lateral, Longitudinal, Vertical; Rotational: Pitch, Roll, Yaw) was the largest and varied with patients in the range (−1.05−1.50mm, −5.06–3.57mm, −5.51−3.49mm; −1.40−2.40°, −1.24−1.74°, and −2.43−1.90°) obtained from mean of XC shifts for each patient. Setup uncertainty in IR positioning (0.88,2.12,1.40mm, and 0.64,0.83,0.96°) was extracted from standard-deviation of XC. Systematic uncertainties of the localizer (−0.03,−0.01,0.03mm, and −0.03,0.00,−0.01°) and frame (0.18,0.25,−1.27mm,−0.32,0.18, and 0.47°) were extracted from means of all XV setups and mean of all XC distributions, respectively. Uncertainties in isocentricity of the MV radiotherapy machine were (0.27,0.24,0.34mm) and kV-imager (0.15,−0.4,0.21mm). Conclusion: A statistical model was developed to evaluate the individual and cumulative systematic and random uncertainties induced by the different hardware and software components of the 6D-ExacTrac-system. The immobilization mask was associated with the largest positioning uncertainty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Status of Understanding for Gear Materials

Today's gear designer has a large selection of possible gear materials to choose from. The choice of which material to use should be based on the requirements of the application and will include the operating conditions of load, speed, and temperature in addition to reliability, weight, noise limitation, accuracy, and cost. The plastic materials are generally low in cost with low strength capabilities and are suitable for many light-duty applications. Die-cast alloy and sintered powder-metal gears are also fairly inexpensive and will operate at higher loads and temperatures than plastic gears. The three types of cast iron offer a medium-strength gear at a cost that varies with the accuracy of machining requirements. Gears can be manufactured from several aluminum alloys for lightweight and medium cost and may be anodized for improved load capacity. The copper alloys, bronze and brass, are more costly but have good sliding and wear properties that are useful for worm gear applications. The hot-forged powder-metal gears have the advantage of medium cost with good accuracy and high strength. Several low- to medium alloy steels are available for gear design and most can be heat treated for added strength. The medium-alloy gear materials offer high strength when case hardened and will satisfy most high-load medium-temperature applications. For more severe load, speed, and temperature requirements the advanced high temperature alloys must be used. These include EX-53, CBS 600, Vasco X-2, Super Nitralloy (5Ni-2Al), and forged AISI M-50. As the requirements become more stringent, the cost will also increase. It is necessary that the gear designer have a working knowledge of the various gear materials in order to match the most economical material with the design requirements.

Dennis P Townsend↗

An Open-Science Approach to Address Individual Response to Simulated GCR In Genetically Diverse Populations of Mice and Humans

This project addresses the challenge of understanding and predicting individual radiation sensitivity by integrating genetics, demographics and biomarker characteristics across species (mice and humans). We hypothesize that ex vivo DNA repair response to GCR components is a central determinant of cancer risk from space radiation and can serve as a biomarker of radiation risk in combination with genetics. Automated image quantification of 53BP1+ radiation-induced foci (RIF) during the first 4-48 h post-irradiation was performed as a function of dose and LET in non-immortalized primary skin fibroblasts derived from 76 mice across 15 strains (5 inbred reference strains and 10 collaborative-cross strains) exposed to X rays (0.1, 1 and 4 Gy), 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100sq. μm), as well as in peripheral blood mononuclear cells (PBMCs) from 768 healthy donors (matched ethnicity, 50/50 male/female, 18-70 years old) exposed to gamma rays (0.1 and 1 Gy), 350 MeV/n 28Si, 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100sq. μm). A genome-wide association study (GWAS) was performed on the mouse strains between DNA damage responses to space radiation and single nucleotide polymorphisms (SNPs). We found SNPs, which were significantly associated to the RIF phenotype, mapped to genes and pathways that are functionally linked to health hazards for deep space exploration (e.g. carcinogenesis, nervous system damage and immune dysfunction). Some of these SNPs were located within protein coding regions, potentially interfering with protein functions and providing promising genetic targets for countermeasures. We also found correlations between both spontaneous and radiation-induced DNA damage and SNPs mapped to pathways associated with cellular metabolism. GWAS is undergoing for the human data. All data have been made available via the NASA Space Biology Open-Science database (genelab.nasa.gov) and we will discuss how various genomic and transcriptomic datasets can be accessed for modeling and integrated using machine learning methods for discovering new radiation biology.

Sylvain V Costes↗

Extending Classification Algorithms to Case-Control Studies

Classification is a common technique applied to ’omics data to build predictive models and identify potential markers of biomedical outcomes. Despite the prevalence of case-control studies, the number of classification methods available to analyze data generated by such studies is extremely limited. Conditional logistic regression is the most commonly used technique, but the associated modeling assumptions limit its ability to identify a large class of sufficiently complicated ’omic signatures. We propose a data preprocessing step which generalizes and makes any linear or nonlinear classification algorithm, even those typically not appropriate for matched design data, available to be used to model case-control data and identify relevant biomarkers in these study designs. We demonstrate on simulated case-control data that both the classification and variable selection accuracy of each method is improved after applying this processing step and that the proposed methods are comparable to or outperform existing variable selection methods. Finally, we demonstrate the impact of conditional classification algorithms on a large cohort study of children with islet autoimmunity.

59 BASIC BIOLOGICAL SCIENCES↗

Classification of animal sounds in a hyperdiverse rainforest using convolutional neural networks with data augmentation

To protect tropical forest biodiversity, we need to be able to detect it reliably, cheaply, and at scale. Automated detection of sound producing animals from passively recorded soundscapes via machine-learning approaches is a promising technique towards this goal, but it is constrained by the necessity of large training data sets. Using soundscapes from a tropical forest in Borneo and a Convolutional Neural Network model (CNN), we investigate i) the minimum viable training data set size for accurate prediction of call types (‘sonotypes’), and ii) the extent to which data augmentation and transfer learning can overcome the issue of small and imbalanced training data sets. We found that even relatively high sample sizes (>80 per sonotype) lead to mediocre accuracy, which however improved significantly with data augmentation and transfer learning, including at extremely small sample sizes (3 per sonotype), regardless of taxonomic group or call characteristics. Neither transfer learning nor data augmentation alone achieved high accuracy. Our results suggest that transfer learning and data augmentation could make the use of CNNs to classify species’ vocalizations feasible even for small soundscape-based projects with many rare species. Retraining our open-source model requires only basic programming skills which makes it possible for individual conservation initiatives to match their local context, in order to enable more evidence-informed management of biodiversity.

54 ENVIRONMENTAL SCIENCES↗

A short pulse (7 {mu}s FWHM) and high repetition rate (dc-5kHz) cantilever piezovalve for pulsed atomic and molecular beams

In this paper we report on the design and operation of a novel piezovalve for the production of short pulsed atomic or molecular beams. The high speed valve operates on the principle of a cantilever piezo. The only moving part, besides the cantilever piezo itself, is a very small O-ring that forms the vacuum seal. The valve can operate continuous (dc) and in pulsed mode with the same drive electronics. Pulsed operation has been tested at repetition frequencies up to 5 kHz. The static deflection of the cantilever, as mounted in the valve body, was measured as a function of driving field strength with a confocal microscope. The deflection and high speed dynamical response of the cantilever can be easily changed and optimized for a particular nozzle diameter or repetition rate by a simple adjustment of the free cantilever length. Pulsed molecular beams with a full width at half maximum pulse width as low as 7 {mu}s have been measured at a position 10 cm downstream of the nozzle exit. This represents a gas pulse with a length of only 10 mm making it well matched to for instance experiments using laser beams. Such a short pulse with 6 bar backing pressure behind a 150 {mu}m nozzle releases about 10{sup 16} particles/pulse and the beam brightness was estimated to be 4x10{sup 22} particles/(s str). The short pulses of the cantilever piezovalve result in a much reduced gas load in the vacuum system. We demonstrate operation of the pulsed valve with skimmer in a single vacuum chamber pumped by a 520 l/s turbomolecular pump maintaining a pressure of 5x10{sup -6} Torr, which is an excellent vacuum to have the strong and cold skimmed molecular beam interact with laser beams only 10 cm downstream of the nozzle to do velocity map slice imaging with a microchannel-plate imaging detector in a single chamber. The piezovalve produces cold and narrow ({Delta}v/v=2%-3%) velocity distributions of molecules seeded in helium or neon at modest backing pressures of only 6 bar. The low gas load of the cantilever valve makes it possible to design very compact single chamber molecular beam machines with high quality cold and intense supersonic beams. The high speed cantilever piezovalve may find broad applicability in experiments where short and strong gas pulses are needed with only modest pumping, the effective use of (expensive) samples, or the production of cold atomic and molecular beams.

43 PARTICLE ACCELERATORS↗

Actinium–DOTA coordination in water from hybrid ML/MM: Structure, free energies, and water-exchange pathways

Quantitative simulation of trivalent ƒ-block chelates in water remains challenging because bonded and non-bonded force-field models make different approximations for coordination structure, exchange dynamics, and ion–ligand interactions in highly charged systems. Here, we develop a hybrid machine-learning/molecular-mechanics (ML/MM) framework for Ac 3+ –DOTA in explicit solvent by training an E(3)-equivariant neural network potential (MACELES) on mechanically embedded QM/MM data for Ac aquo and Ac–DOTA species and coupling it to NAMD 2.14 with particle-mesh Ewald electrostatics. Nanosecond ML/MM trajectories remain numerically stable and preserve chelate integrity, yielding a compact DOTA inner shell with an inner-sphere water coordination number of CN Ac,O w ≈ 1.7 arising from a dynamic equilibrium between one- and two-water states (37.5% and 59.9% of frames; three waters 2.5%). A 5 ns potential of mean force shows two low-lying basins at CN Ac,O w ≈ 1 and CN Ac,O w ≈ 2. DFT end-state free energies are consistent with the ML/MM profile, and DFT minimum-energy paths provide a qualitative electronic-structure reference for the observed basin connectivity. State-resolved kinetics reveal picosecond water-exchange pathways that couple hydration changes to transient DOTA arm fluctuations, and training-set comparisons show that temperature-matched Ac–DOTA data optimize energy/force accuracy while more diverse solvated data improve charge prediction. Overall, the present hybrid ML/MM model provides a practical description of Ac 3+ –DOTA hydration thermodynamics and short-time exchange behavior in explicit water at MD-like cost.

Actinium↗

Data Report on the Newest Batch of PCEA Graphite for the VHTR Baseline Graphite Characterization Program

This report details a comparison of mechanical and physical properties from the first billet of extruded PCEA nuclear-grade graphite from the newest batch of PCEA procured from GrafTech. Testing has largely been completed on three of the billets from the original batch of PCEA, with data distributions for those billets exhibiting a much wider range of values when compared to the distributions of properties from other grades. A higher propensity for extremely low values or specimens that broke while machining or handling was also characteristic of the billets from the first batch, owing to unusually large fissures or disparate flaws in the billets in an as-manufactured state. Coordination with GrafTech prior to placing the order for a second batch of PCEA included discussions on these large disparate flaws and how to prevent them during the manufacturing process. This report provides a comparison of the observed data distributions from properties measured in the first billet from the new batch of PCEA with those observed in the original batch, in order that an evaluation of tighter control of the manufacturing process and the outcome of these controls on final properties can be ascertained. Additionally, this billet of PCEA is the first billet to formally include measurements from two alternate test techniques that will become part of the Baseline Graphite Characterization database – the three-point bend test on sub-sized cylinders and the Brazilian disc splitting tensile strength test. As the program moves forward, property distributions from these two tests will be based on specimen geometries that match specimen geometries being used in the irradiated Advanced Graphite Creep (AGC) program. This will allow a more thorough evaluation of both the utility of the test and expected variability in properties when using those approaches on the constrained geometries of specimens irradiated in the Advanced Test Reactor as part of the AGC experiment.

36 MATERIALS SCIENCE↗

Automated generation and ensemble-learned matching of X-ray absorption spectra

X-ray absorption spectroscopy (XAS) is a widely used materials characterization technique to determine oxidation states, coordination environment, and other local atomic structure information. Analysis of XAS relies on comparison of measured spectra to reliable reference spectra. However, existing databases of XAS spectra are highly limited both in terms of the number of reference spectra available as well as the breadth of chemistry coverage. In this work, we report the development of XASdb, a large database of computed reference XAS, and an Ensemble-Learned Spectra IdEntification (ELSIE) algorithm for the matching of spectra. XASdb currently hosts more than 800,000 K-edge X-ray absorption near-edge spectra (XANES) for over 40,000 materials from the open-science Materials Project database. We discuss a high-throughput automation framework for FEFF calculations, built on robust, rigorously benchmarked parameters. FEFF is a computer program uses a real-space Green’s function approach to calculate X-ray absorption spectra. Here, we will demonstrate that the ELSIE algorithm, which combines 33 weak “learners” comprising a set of preprocessing steps and a similarity metric, can achieve up to 84.2% accuracy in identifying the correct oxidation state and coordination environment of a test set of 19 K-edge XANES spectra encompassing a diverse range of chemistries and crystal structures. The XASdb with the ELSIE algorithm has been integrated into a web application in the Materials Project, providing an important new public resource for the analysis of XAS to all materials researchers. Finally, the ELSIE algorithm itself has been made available as part of veidt, an open source machine-learning library for materials science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication of an Absorber-Coupled MKID Detector

Absorber-coupled microwave kinetic inductance detector (MKID) arrays were developed for submillimeter and far-infrared astronomy. These sensors comprise arrays of lambda/2 stepped microwave impedance resonators patterned on a 1.5-mm-thick silicon membrane, which is optimized for optical coupling. The detector elements are supported on a 380-mm-thick micro-machined silicon wafer. The resonators consist of parallel plate aluminum transmission lines coupled to low-impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The transmission lines simultaneously act to absorb optical power and employ an appropriate surface impedance and effective filling fraction. The fabrication techniques demonstrate high-fabrication yield of MKID arrays on large, single-crystal membranes and sub-micron front-to-back alignment of the micro strip circuit. An MKID is a detector that operates upon the principle that a superconducting material s kinetic inductance and surface resistance will change in response to being exposed to radiation with a power density sufficient to break its Cooper pairs. When integrated as part of a resonant circuit, the change in surface impedance will result in a shift in its resonance frequency and a decrease of its quality factor. In this approach, incident power creates quasiparticles inside a superconducting resonator, which is configured to match the impedance of free space in order to absorb the radiation being detected. For this reason MKIDs are attractive for use in large-format focal plane arrays, because they are easily multiplexed in the frequency domain and their fabrication is straightforward. The fabrication process can be summarized in seven steps: (1) Alignment marks are lithographically patterned and etched all the way through a silicon on insulator (SOI) wafer, which consists of a thin silicon membrane bonded to a thick silicon handle wafer. (2) The metal microwave circuitry on the front of the membrane is patterned and etched. (3) The wafer is then temporarily bonded with wafer wax to a Pyrex wafer, with the SOI side abutting the Pyrex. (4) The silicon handle component of the SOI wafer is subsequently etched away so as to expose the membrane backside. (5) The wafer is flipped over, and metal microwave circuitry is patterned and etched on the membrane backside. Furthermore, cuts in the membrane are made so as to define the individual detector array chips. (6) Silicon frames are micromachined and glued to the silicon membrane. (7) The membranes, which are now attached to the frames, are released from the Pyrex wafer via dissolution of the wafer wax in acetone.

Brown, Ari↗

Characterizing Families of Spectral Similarity Scores and Their Use Cases for Gas Chromatography–Mass Spectrometry Small Molecule Identification

Metabolomics provides a unique snapshot into the world of small molecules and the complex biological processes that govern the human, animal, plant, and environmental ecosystems encapsulated by the One Health modeling framework. However, this “molecular snapshot” is only as informative as the number of metabolites confidently identified within it. The spectral similarity (SS) score is traditionally used to identify compound(s) in mass spectrometry approaches to metabolomics, where spectra are matched to reference libraries of candidate spectra. Unfortunately, there is little consensus on which of the dozens of available SS metrics should be used. This lack of standard SS score creates analytic uncertainty and potentially leads to issues in reproducibility, especially as these data are integrated across other domains. In this work, we use metabolomic spectral similarity as a case study to showcase the challenges in consistency within just one piece of the One Health framework that must be addressed to enable data science approaches for One Health problems. Here, using a large cohort of datasets comprising both standard and complex datasets with expert-verified truth annotations, we evaluated the effectiveness of 66 similarity metrics to delineate between correct matches (true positives) and incorrect matches (true negatives). We additionally characterize the families of these metrics to make informed recommendations for their use. Our results indicate that specific families of metrics (the Inner Product, Correlative, and Intersection families of scores) tend to perform better than others, with no single similarity metric performing optimally for all queried spectra. This work and its findings provide an empirically-based resource for researchers to use in their selection of similarity metrics for GC-MS identification, increasing scientific reproducibility through taking steps towards standardizing identification workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Bayesian inverse modeling of the atmospheric transport and emissions of a controlled tracer release from a nuclear power plant

Probability distribution functions (PDFs) of model inputs that affect the transport and dispersion of a trace gas released from a coastal California nuclear power plant are quantified using ensemble simulations, machine-learning algorithms, and Bayesian inversion. The PDFs are constrained by observations of tracer concentrations and account for uncertainty in meteorology, transport, diffusion, and emissions. Meteorological uncertainty is calculated using an ensemble of simulations of the Weather Research and Forecasting (WRF) model that samples five categories of model inputs (initialization time, boundary layer physics, land surface model, nudging options, and reanalysis data). The WRF output is used to drive tens of thousands of FLEXPART dispersion simulations that sample a uniform distribution of six emissions inputs. Machine-learning algorithms are trained on the ensemble data and used to quantify the sources of ensemble variability and to infer, via inverse modeling, the values of the 11 model inputs most consistent with tracer measurements. We find a substantial ensemble spread in tracer concentrations (factors of 10 to 10 3 ), most of which is due to changing emissions inputs (about 80%), though the cumulative effects of meteorological variations are not negligible. The performance of the inverse method is verified using synthetic observations generated from arbitrarily selected simulations. When applied to measurements from a controlled tracer release experiment, the inverse method satisfactorily determines the location, start time, duration and amount. In a 2 km × 2 km area of possible locations, the actual location is determined to within 200m. The start time is determined to within 5min out of 2h, and the duration to within 50min out of 4h. Over a range of release amounts of 10 to 1000kg, the estimated amount exceeds the actual amount of 146kg by only 32kg. The inversion also estimates probabilities of different WRF configurations. In conclusion, to best match the tracer observations, the highest-probability cases in WRF are associated with using a late initialization time and specific reanalysis data products.

54 ENVIRONMENTAL SCIENCES↗

Thermal Dispersion Within a Porous Medium Near a Solid Wall

The regenerator is a key component to Stirling cycle machine efficiency. Typical regenerators are of sintered fine wires or layers of fine-wire screens. Such porous materials are contained within solid-waH casings. Thermal energy exchange between the regenerator and the casing is important to cycle performance for the matrix and casing would not have the same axial temperature profile in an actual machine. Exchange from one to the other may allow shunting of thermal energy, reducing cycle efficiency. In this paper, temperature profiles within the near-wall region of the matrix are measured and thermal energy transport, termed thermal dispersion, is inferred. The data show how the wall affects thermal transport. Transport normal to the mean flow direction is by conduction within the solid and fluid and by advective transport within the matrix. In the near-wall region, both may be interrupted from their normal in-core pattern. Solid conduction paths are broken and scales of advective transport are damped. An equation is presented which describes this change for a wire screen mesh. The near-wall layer typically acts as an insulating layer. This should be considered in design or analysis. Effective thermal conductivity within the core is uniform. In-core transverse thermal effective conductivity values are compared to direct and indirect measurements reported elsewhere and to 3D numerical simulation results, computed previously and reported elsewhere. The 3-D CFD model is composed of six cylinders in cross flow, staggered in arrangement to match the dimensions and porosity of the matrix used in the experiments. The commercial code FLUENT is used to obtain the flow and thermal fields. The thermal dispersion and effective thermal conductivities for the matrix are computed from the results.

Simon, T.↗

SU-E-T-379: Evaluation of An EPID-Based System for Daily Dosimetry Check by Comparison with a Widely-Used Ionization Chamber-Based Device

Purpose: To examine the feasibility of using Varian’s EPID-based Machine Performance Check (MPC) system to track daily machine output through comparison with Sun Nuclear’s DailyQA3 (DQA) device. Methods: Daily machine outputs for two photon energies (6 and 16MV) and five electron energies (6, 9, 12, 16, 20MeV) were measured for one month using both MPC and DQA. Baselines measurements for MPC were taken at the start of the measurement series, while DQA baselines were set at an earlier date. In order to make absolute comparisons with MPC, all DQA readings were referenced to the average of the first three DQA readings in that series, minimizing systematic differences between the measurement techniques due to baseline differences. In addition to daily output measurements, weekly averages were also calculated and compared. Finally, the electron energy dependence of each measurement technique was examined by comparing energy-specific measurements to the average electron output of all energies each day. Results: For 6 and 16MV photons, the largest absolute percent differences between MPC and DQA were 0.60% and 0.73%, respectively. Weekly averages were within 0.17% and 0.23%, respectively. For all five electron energies, the greatest absolute percent differences between MPC and DQA for each energy ranged from 0.49%–0.83%. Weekly averages ranged from 0.07%–0.28%. DQA energy-specific electron readings matched the average electron output within 0.29% for all days and all energies. MPC energy-specific readings matched the average within 0.21% for 9–20MeV. However, 6MeV showed a larger distribution about the average with four days showing a difference greater than 0.30% and a maximum difference of 0.51%. Conclusion: MPC output measurements correlated well with the widely-used DQA3 for most beam energies, making it a reliable back up technique for daily output monitoring. However, MPC may display an energy dependence for lower electrons energies, requiring additional investigation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The F-15B Lifting Insulating Foam Trajectory (LIFT) Flight Test

A series of flight tests has been performed to assess the structural survivability of space shuttle external tank debris, known as divots, in a real flight environment. The NASA F-15B research test bed aircraft carried the Aerodynamic Flight Test Fixture configured with a shuttle foam divot ejection system. The divots were released in flight at subsonic and supersonic test conditions matching points on the shuttle ascent trajectory. Very high-speed digital video cameras recorded the divot trajectories. The objectives of the flight test were to determine the structural survivability of the divots in a real flight environment, assess the aerodynamic stability of the divots, and provide divot trajectory data for comparison with debris transport models. A total of 10 flights to Mach 2 were completed, resulting in 36 successful shuttle foam divot ejections. Highspeed video was obtained at 2,000 pictures per second for all of the divot ejections. The divots that were cleanly ejected remained structurally intact. The conical frustum-shaped divots tended to aerodynamically trim in both the subsonic and supersonic free-stream flow.

Corda, Stephen↗

Simulating water dynamics related to pedogenesis across space and time: Implications for four-dimensional digital soil mapping

Digital soil mapping (DSM) relies on machine-learning and geostatistics to represent soil property observations across space. DSM techniques are powerful but often empirical, being limited to the quality and density of point samples. Water dynamics are closely related to soil variability, and the physics that govern water movement are well known. Hydrological properties can hence be simulated by physical models through space and time, unveiling key characteristics about soils. We propose the use of hydrologic models to map soils across the surface (2D), depth (1D), and time (1D)–which provides a 4D approach to digital soil mapping (4DSM). The Distributed Hydrology Soil Vegetation Model (DHSVM) was applied to a watershed currently under pasture. Moisture sensors and wells were installed at different depths in the watershed on summit, sideslope and toeslope positions to validate the model. DHSVM simulations of soil moisture distribution and depth to saturation were performed during the hydrological year (October 2008-September 2009). Clusters of similar pixels based on soil moisture values were determined using Dynamic Time Warping (DTW) to align temporal data and K-means. Clustering was performed both seasonally and for the entire year. Temporal patterns simulated by DHSVM matched measurements given by moisture sensors and wells. Seasonal clusters differed from the annual cluster. Distinct clusters were observed for each season and with depth, showing that spatiotemporal soil variability is lost when statically assessing soils. Spatiotemporal clusters corroborated field observations of fragipan occurrence not explicitly spatially mapped by Soil Survey Geographic Database (SSURGO). If a connection can be made between water and soils, static and dynamic soil variability can be predicted using physically based hydrologic models. Hydrologic models can benefit soil mapping by enabling reliable 4D simulation of water dynamics, which are fundamental to soil variability and soil classification and directly relate to biological, physical and chemical soil processes not captured by typical soil sampling protocols.

54 ENVIRONMENTAL SCIENCES↗

Impact of Color Space and Color Resolution on Vehicle Recognition Models

In this study, we analyze both linear and nonlinear color mappings by training on versions of a curated dataset collected in a controlled campus environment. We experiment with color space and color resolution to assess model performance in vehicle recognition tasks. Color encodings can be designed in principle to highlight certain vehicle characteristics or compensate for lighting differences when assessing potential matches to previously encountered objects. The dataset used in this work includes imagery gathered under diverse environmental conditions, including daytime and nighttime lighting. Experimental results inform expectations for possible improvements with automatic color space selection through feature learning. Moreover, we find there is only a gradual decrease in model performance with degraded color resolution, which suggests the need for simplified data collection and processing. By focusing on the most critical features, we could see improved model generalization and robustness, as the model becomes less prone to overfitting to noise or irrelevant details in the data. Such a reduction in resolution will lower computational complexity, leading to quicker training and inference times.

47 OTHER INSTRUMENTATION↗

Sampling Within k-Means Algorithm to Cluster Large Datasets

Due to current data collection technology, our ability to gather data has surpassed our ability to analyze it. In particular, k-means, one of the simplest and fastest clustering algorithms, is ill-equipped to handle extremely large datasets on even the most powerful machines. Our new algorithm uses a sample from a dataset to decrease runtime by reducing the amount of data analyzed. We perform a simulation study to compare our sampling based k-means to the standard k-means algorithm by analyzing both the speed and accuracy of the two methods. Results show that our algorithm is significantly more efficient than the existing algorithm with comparable accuracy. Further work on this project might include a more comprehensive study both on more varied test datasets as well as on real weather datasets. This is especially important considering that this preliminary study was performed on rather tame datasets. Also, these datasets should analyze the performance of the algorithm on varied values of k. Lastly, this paper showed that the algorithm was accurate for relatively low sample sizes. We would like to analyze this further to see how accurate the algorithm is for even lower sample sizes. We could find the lowest sample sizes, by manipulating width and confidence level, for which the algorithm would be acceptably accurate. In order for our algorithm to be a success, it needs to meet two benchmarks: match the accuracy of the standard k-means algorithm and significantly reduce runtime. Both goals are accomplished for all six datasets analyzed. However, on datasets of three and four dimension, as the data becomes more difficult to cluster, both algorithms fail to obtain the correct classifications on some trials. Nevertheless, our algorithm consistently matches the performance of the standard algorithm while becoming remarkably more efficient with time. Therefore, we conclude that analysts can use our algorithm, expecting accurate results in considerably less time.

99 GENERAL AND MISCELLANEOUS↗