Search NASA⌕ Search

SEARCH · Search NASA

Results for “Methods and Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs

Purpose: A robust and accurate method that allows the automatic detection of fiducial markers in MV and kV projection image pairs is proposed. The method allows to automatically correct for inter or intrafraction motion. Methods: Intratreatment MV projection images are acquired during each of five treatment beams of prostate cancer patients with four implanted fiducial markers. The projection images are first preprocessed using a series of marker enhancing filters. 2D candidate marker locations are generated for each of the filtered projection images and 3D candidate marker locations are reconstructed by pairing candidates in subsequent projection images. The correct marker positions are retrieved in 3D by the minimization of a cost function that combines 2D image intensity and 3D geometric or shape information for the entire marker configuration simultaneously. This optimization problem is solved using dynamic programming such that the globally optimal configuration for all markers is always found. Translational interfraction and intrafraction prostate motion and the required patient repositioning is assessed from the position of the centroid of the detected markers in different MV image pairs. The method was validated on a phantom using CT as ground-truth and on clinical data sets of 16 patients using manual marker annotations as ground-truth. Results: The entire setup was confirmed to be accurate to around 1 mm by the phantom measurements. The reproducibility of the manual marker selection was less than 3.5 pixels in the MV images. In patient images, markers were correctly identified in at least 99% of the cases for anterior projection images and 96% of the cases for oblique projection images. The average marker detection accuracy was 1.4{+-}1.8 pixels in the projection images. The centroid of all four reconstructed marker positions in 3D was positioned within 2 mm of the ground-truth position in 99.73% of all cases. Detecting four markers in a pair of MV images takes a little less than a second where most time is spent on the image preprocessing. Conclusions: The authors have developed a method to automatically detect multiple markers in a pair of projection images that is robust, accurate, and sufficiently fast for clinical use. It can be used for kV, MV, or mixed image pairs and can cope with limited motion between the projection images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A thermal porosimetry method to estimate pore size distribution in highly porous insulating materials

Standard pore size determination methods such as mercury porosimetry, nitrogen sorption, microscopy, or x-ray tomography are not always applicable to highly porous, low density, and thus very fragile materials. For this kind of materials, a method based on thermal characterization is proposed. Indeed, the thermal conductivity of a highly porous and insulating medium is significantly dependent on the thermal conductivity of the interstitial gas that depends on both gas pressure and size of the considered pore (Knudsen effect). It is also possible to link the pore size with the thermal conductivity of the medium. Thermal conductivity measurements are realized on specimens placed in an enclosure where the air pressure is successively set to different values varying from 10{sup -1} to 10{sup 5} Pa. Knowing the global porosity ratio, an effective thermal conductivity model for a two-phase air-solid material based on a combined serial-parallel model is established. Pore size distribution can be identified by minimizing the sum of the quadratic differences between measured values and modeled ones. The results of the estimation process are the volume fractions of the chosen ranges of pore size. In order to validate the method, measurements done on insulating materials are presented. The results are discussed and show that pore size distribution estimated by the proposed method is coherent.

36 MATERIALS SCIENCE↗

Learning the temporal evolution of multivariate densities via normalizing flows

In this work, we propose a method to learn multivariate probability distributions using sample path data from stochastic differential equations. Specifically, we consider temporally evolving probability distributions (e.g., those produced by integrating local or nonlocal Fokker–Planck equations). Here, we analyze this evolution through machine learning assisted construction of a time-dependent mapping that takes a reference distribution (say, a Gaussian) to each and every instance of our evolving distribution. If the reference distribution is the initial condition of a Fokker–Planck equation, what we learn is the time-T map of the corresponding solution. Specifically, the learned map is a multivariate normalizing flow that deforms the support of the reference density to the support of each and every density snapshot in time. We demonstrate that this approach can approximate probability density function evolutions in time from observed sampled data for systems driven by both Brownian and Lévy noise. We present examples with two- and three-dimensional, uni- and multimodal distributions to validate the method.

97 MATHEMATICS AND COMPUTING↗

Finite element analyses of single particle crushing tests incorporating computed tomography imaging and damage mechanics

Fracture of individual grains within a granular assembly affect the strength and deformation behavior of granular materials under large stress states. Interparticle forces, leading to contact stresses and ultimately fracture initiation, are influenced by particle morphology. A numerical method that incorporates both particle fracture and morphology can provide a more accurate model of a granular material’s macro-scale response. This research investigates an approach to modeling fracture initiation and propagation within individual grains, utilizing high resolution X-ray computed tomography (CT) imaging to consider grain morphology and an explicit finite element code optimized for high performance computing which incorporates damage mechanics. Using precisely measured force-displacement curves from single particle crushing tests of manufactured quartz spheres, the method is validated, and the effects of fracture properties on grain fragmentation are determined. This approach is then used to simulate single particle crushing of Ottawa sand, with grain morphology incorporated through discretized CT images. Here the effect of grain orientation on the force and applied displacement at catastrophic splitting is also explored. The proposed discrete particle based finite element framework can be applied to modeling granular assemblies, considering the effect of individual particle shape and fracture on the assembly’s deformation response through well calibrated numerical simulations.

42 ENGINEERING↗

Implementation of ANL’s Mechanics Based Evolutionary Fatigue Modeling Through ABAQUS-WARP3D Based High-Performance Computing Framework

This report presents an update on the environmental fatigue research that is being conducted at Argonne National Laboratory in support of the Department of Energy’s Light Water Reactor Sustainability (LWRS) program. Argonne is developing a fully mechanistic fatigue evaluation approach without using empirical fatigue (S~N) curves. This approach is based on the fundamental concept of the time evolution of progressive fatigue damage rather than on the conventional S~N curve approaches using end-of-life data. In FY 2017, we performed extensive validation of this approach with respect to fatigue test data for 316 stainless steel [1]. This validation was performed for different loading cases, including constant, variable, and random amplitude. In the present FY 2018 semi-annual report, we present the further advances of Argonne’s environmental fatigue research work in the context for more practical applications. In this report, we discuss a methodology for fully mechanistic (i.e., not using S~N curves) fatigue life evaluation of reactor components subjected to realistic loading cycles, namely, design-basis loading cycles. The loading cycles include plant heat-up, full-power, and cool-down operations. As a test case, we considered a typical pressurized water reactor surge line, which is made of 316 SS. To perform the fatigue simulation for thousands of fatigue cycles in a computationally cost effective way, we modified our previous desktop-based finite element (FE) modeling approach to work in a high-performance computing (HPC) framework. For the HPC implementation, we developed a hybrid framework based on commercial FE software (ABAQUS), open-source FE software (WARP3D), and Argonne-developed evolutionary cyclic-plasticity modeling methods. We validated this HPC-based cycle-by-cycle damage model for the entire fatigue life of a Pressurized Water Reactor (PWR) surge line (SL) pipe with respect to assumed loading cycles. The simulated fatigue life was found to be 5855 cycles, which is 85% accurate as compared to the corresponding small-specimen-based experimental fatigue life (6914 cycles). Also, the simulated stress history captures the cyclic hardening and softening behavior of the material for entire fatigue cycles. The FE simulation of the PWR SL pipe was conducted in a reasonable time of 12.5 days. These results show the promise that a fully mechanistic (not using S~N curves) fatigue life evaluation of a safety-critical nuclear reactor component (or even other safety critical components like those in aircraft, aero-engines, etc.) is possible. We anticipate that this type of methodology will drastically reduce the uncertainly associated with conventional fatigue life estimates based on empirical S~N curves. We also proposed an FE model that is based on a hybrid full-component and single-element approach and that can readily be used by industry if HPC resources are not available. In this approach, a single-cycle FE simulation has to be performed first for the required loading cycle. Then, the resulting strain/stress profile at the hotspot (highest strain/stress location) is used as input strain/stress loading to the single-element FE model. The single-element FE model is run under multiple fatigue cycles as long as the failure criteria are achieved. The cycle number at failure gives the fatigue life of the component in question. This cost-effective framework does not require expensive HPC hardware and can be performed in a reasonable time by using a desktop computer. We demonstrated this approach with respect to PWR SL fatigue evaluation under two realistic design-basis loading cycles (simple and detailed). The associated results were validated with respect to test data obtained through fatigue testing of uniaxial specimens under the in-air condition at 300 °C. The approach is in the development stage and requires further improvement and validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Applicable Experiment Selection

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-IP calculations performed to select applicable experiments for validation of 11 MPC-32 DPCs. The companion paper discusses the TSUNAMI-3D calculations used to generate sensitivity data to support the experiment selections discussed here. Experiment selection is based on the sensitivity/uncertainty (S/U) methods used to validate criticality safety calculations of as-loaded DPCs containing pressurized water reactor (PWR) spent nuclear fuel (SNF). This process has been demonstrated and is summarized in this paper. The approach is similar to that used in NUREG/CR-7109, which provides an approach for validation of PWR burnup credit (BUC), including major and minor actinides and major fission products. The premise of S/U-based validation is that applicable experiments—those having a similar bias to a given application system—will have similar sensitivities for each isotope and reaction in the two systems. It is assumed that cross sections with larger uncertainties are more likely to contain data errors which contribute to the bias. The integral index c k thus propagates the system sensitivities with the nuclear covariance data to calculate a correlation coefficient representing the similarity of the two systems. In this work, a c k value of 0.8 or higher is interpreted as identifying an experiment with sufficient similarity for use in validation. This paper presents a brief summary of the characteristics of the 11 MPC-32 DPCs used in the proof of-principle analysis for as-loaded criticality safety calculation validation and an overview of the critical experiment suite with which each of these DPC models was compared. A summary and discussion of c k results is also presented, followed by conclusions and a discussion of future work to be performed for validation of UNF ST&DARDS as-loaded criticality safety calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstruction of implanted marker trajectories from cone-beam CT projection images using interdimensional correlation modeling

Purpose: Cone-beam CT (CBCT) is a widely used imaging modality for image-guided radiotherapy. Most vendors provide CBCT systems that are mounted on a linac gantry. Thus, CBCT can be used to estimate the actual 3-dimensional (3D) position of moving respiratory targets in the thoracic/abdominal region using 2D projection images. The authors have developed a method for estimating the 3D trajectory of respiratory-induced target motion from CBCT projection images using interdimensional correlation modeling. Methods: Because the superior–inferior (SI) motion of a target can be easily analyzed on projection images of a gantry-mounted CBCT system, the authors investigated the interdimensional correlation of the SI motion with left–right and anterior–posterior (AP) movements while the gantry is rotating. A simple linear model and a state-augmented model were implemented and applied to the interdimensional correlation analysis, and their performance was compared. The parameters of the interdimensional correlation models were determined by least-square estimation of the 2D error between the actual and estimated projected target position. The method was validated using 160 3D tumor trajectories from 46 thoracic/abdominal cancer patients obtained during CyberKnife treatment. The authors’ simulations assumed two application scenarios: (1) retrospective estimation for the purpose of moving tumor setup used just after volumetric matching with CBCT; and (2) on-the-fly estimation for the purpose of real-time target position estimation during gating or tracking delivery, either for full-rotation volumetric-modulated arc therapy (VMAT) in 60 s or a stationary six-field intensity-modulated radiation therapy (IMRT) with a beam delivery time of 20 s. Results: For the retrospective CBCT simulations, the mean 3D root-mean-square error (RMSE) for all 4893 trajectory segments was 0.41 mm (simple linear model) and 0.35 mm (state-augmented model). In the on-the-fly simulations, prior projections over more than 60° appear to be necessary for reliable estimations. The mean 3D RMSE during beam delivery after the simple linear model had established with a prior 90° projection data was 0.42 mm for VMAT and 0.45 mm for IMRT. Conclusions: The proposed method does not require any internal/external correlation or statistical modeling to estimate the target trajectory and can be used for both retrospective image-guided radiotherapy with CBCT projection images and real-time target position monitoring for respiratory gating or tracking.

60 APPLIED LIFE SCIENCES↗

Objectively Quantifying Radiation Esophagitis With Novel Computed Tomography–Based Metrics

Purpose: To study radiation-induced esophageal expansion as an objective measure of radiation esophagitis in patients with non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy. Methods and Materials: Eighty-five patients had weekly intra-treatment CT imaging and esophagitis scoring according to Common Terminlogy Criteria for Adverse Events 4.0, (24 Grade 0, 45 Grade 2, and 16 Grade 3). Nineteen esophageal expansion metrics based on mean, maximum, spatial length, and volume of expansion were calculated as voxel-based relative volume change, using the Jacobian determinant from deformable image registration between the planning and weekly CTs. An anatomic variability correction method was validated and applied to these metrics to reduce uncertainty. An analysis of expansion metrics and radiation esophagitis grade was conducted using normal tissue complication probability from univariate logistic regression and Spearman rank for grade 2 and grade 3 esophagitis endpoints, as well as the timing of expansion and esophagitis grade. Metrics' performance in classifying esophagitis was tested with receiver operating characteristic analysis. Results: Expansion increased with esophagitis grade. Thirteen of 19 expansion metrics had receiver operating characteristic area under the curve values >0.80 for both grade 2 and grade 3 esophagitis endpoints, with the highest performance from maximum axial expansion (MaxExp1) and esophageal length with axial expansion ≥30% (LenExp30%) with area under the curve values of 0.93 and 0.91 for grade 2, 0.90 and 0.90 for grade 3 esophagitis, respectively. Conclusions: Esophageal expansion may be a suitable objective measure of esophagitis, particularly maximum axial esophageal expansion and esophageal length with axial expansion ≥30%, with 2.1 Jacobian value and 98.6 mm as the metric value for 50% probability of grade 3 esophagitis. The uncertainty in esophageal Jacobian calculations can be reduced with anatomic correction methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Diffuse Foreground Subtraction with the ILC Method: CMB Map and Angular Power Spectrum Using Planck and WMAP Observations

We report an improved technique for diffuse foreground minimization from Cosmic Microwave Background (CMB) maps using a new multiphase iterative harmonic space internal-linear-combination (HILC) approach. Our method nullifies a foreground leakage that was present in the old and usual iterative HILC method. In phase 1 of the multiphase technique, we obtain an initial cleaned map using the single iteration HILC approach over the desired portion of the sky. In phase 2, we obtain a final CMB map using the iterative HILC approach; however, now, to nullify the leakage, during each iteration, some of the regions of the sky that are not being cleaned in the current iteration are replaced by the corresponding cleaned portions of the phase 1 map. We bring all input frequency maps to a common and maximum possible beam and pixel resolution at the beginning of the analysis, which significantly reduces data redundancy, memory usage, and computational cost, and avoids, during the HILC weight calculation, the deconvolution of partial sky harmonic coefficients by the azimuthally symmetric beam and pixel window functions, which in a strict mathematical sense, are not well defined. Using WMAP 9 year and Planck 2015 frequency maps, we obtain foreground-cleaned CMB maps and a CMB angular power spectrum for the multipole range 2⩽ℓ⩽2500. Our power spectrum matches the published Planck results with some differences at different multipole ranges. We validate our method by performing Monte Carlo simulations. Finally, we show that the weights for HILC foreground minimization have the intrinsic characteristic that they also tend to produce a statistically isotropic CMB map.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated registration of multispectral MR vessel wall images of the carotid artery

Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purpose of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and moving image after registration. Results: The average required manual translation per image slice was 1.33 mm. Translations were larger as the patient was longer inside the scanner. Manual alignment took 187.5 s per patient resulting in a mean surface distance of 0.271 ± 0.127 mm. After minimal user interaction to generate the mask in the fixed image, the remaining sequences are automatically registered with a computation time of 52.0 s per patient. The optimal registration strategy used a circular mask with a diameter of 10 mm, a 3D B-spline transformation model with a control point spacing of 15 mm, mutual information as image similarity metric, and the precontrast T1W TSE as fixed image. A mean surface distance of 0.288 ± 0.128 mm was obtained with these settings, which is very close to the accuracy of the manual alignment procedure. The exact registration parameters and software were made publicly available. Conclusions: An automated registration method was developed and optimized, only needing two mouse clicks to mark the start and end point of the artery. Validation on a large group of patients showed that automated image registration has similar accuracy as the manual alignment procedure, substantially reducing the amount of user interactions needed, and is multiple times faster. In conclusion, the authors believe that the proposed automated method can replace the current manual procedure, thereby reducing the time to analyze the images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Pulmonary Nodules on Chest Computed Tomography and Risk of Recurrence in Stage IV Wilms Tumor

Purpose: Chest computed tomography (CT) is currently accepted as the main modality for initial disease staging and response assessment in Wilms tumor (WT). However, there is great variability in the number and size of lung metastases at the time of diagnosis and after induction chemotherapy. There is a lack of clinical evidence as to how this variability in tumor burden affects choice of therapy and disease outcome. This study sought to evaluate a previously proposed lung metastases risk stratification system based on CT findings and clinical outcomes in stage IV WT patients. Methods and Materials: Thirty-five pediatric patients with a diagnosis of stage IV WT with evaluable pre- and postdiagnosis CT scans between 1997 and 2012 were included in the analysis. Patients were divided into low-, intermediate-, and high-risk categories based on the size and number of pulmonary metastases before and after 6 weeks of chemotherapy. Association of the lung risk groups with lung recurrence-free survival and overall survival at each time point was analyzed with relevant covariates. Results: Risk group distribution both at diagnosis and after induction chemotherapy was not influenced by tumor histology. Initial risk grouping suggested an association with disease-free survival at 5 years (P=.074); however, the most significant correlation was with postinduction chemotherapy disease status (P=.027). In patients with an intermediate or high burden of disease after 6 weeks of chemotherapy, despite receiving whole-lung and boost irradiation, survival outcomes were poorer. Conclusions: Pulmonary tumor burden in stage IV WT on chest CT can predict disease outcome. Patients with intermediate- or low-risk disease, especially after induction therapy, have a higher risk for recurrence. After prospective validation, this method may become a valuable tool in adaptation of therapy to improve outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gaussian integral method for void fraction

Here, a novel method, the Gaussian Integral Method (GIM), is presented for calculating void fractions in Computational Fluid Dynamics–Discrete Element Method (CFD-DEM) simulations. GIM is versatile and applicable to various grid types, including structured and unstructured polyhedral meshes, without requiring special boundary treatments. An optimization technique is introduced to make GIM independent of grid resolution and type. The method is validated against experimental data from a fluidized bed, demonstrating that GIM produces realistic simulations closely resembling experimental observations. Additionally, unstructured polyhedral grids using GIM outperform structured grids of equivalent resolution, yielding results more aligned with experimental data. The gradient of the void fraction is computed in the CFD solver and utilized in the DEM solver for precise estimation at particle locations. Overall, GIM provides an effective solution for void fraction calculations in particulate media simulations with complex geometries, enhancing the accuracy and applicability of CFD-DEM simulations for industrial processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MO-DE-207A-07: Filtered Iterative Reconstruction (FIR) Via Proximal Forward-Backward Splitting: A Synergy of Analytical and Iterative Reconstruction Method for CT

Purpose: This work is to develop a general framework, namely filtered iterative reconstruction (FIR) method, to incorporate analytical reconstruction (AR) method into iterative reconstruction (IR) method, for enhanced CT image quality. Methods: FIR is formulated as a combination of filtered data fidelity and sparsity regularization, and then solved by proximal forward-backward splitting (PFBS) algorithm. As a result, the image reconstruction decouples data fidelity and image regularization with a two-step iterative scheme, during which an AR-projection step updates the filtered data fidelity term, while a denoising solver updates the sparsity regularization term. During the AR-projection step, the image is projected to the data domain to form the data residual, and then reconstructed by certain AR to a residual image which is in turn weighted together with previous image iterate to form next image iterate. Since the eigenvalues of AR-projection operator are close to the unity, PFBS based FIR has a fast convergence. Results: The proposed FIR method is validated in the setting of circular cone-beam CT with AR being FDK and total-variation sparsity regularization, and has improved image quality from both AR and IR. For example, AIR has improved visual assessment and quantitative measurement in terms of both contrast and resolution, and reduced axial and half-fan artifacts. Conclusion: FIR is proposed to incorporate AR into IR, with an efficient image reconstruction algorithm based on PFBS. The CBCT results suggest that FIR synergizes AR and IR with improved image quality and reduced axial and half-fan artifacts. The authors was partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

60 APPLIED LIFE SCIENCES↗

Prediction of chlorine and fluorine crystal structures at high pressure using symmetry driven structure search with geometric constraints

The high-pressure properties of fluorine and chlorine are not yet well understood because both are highly reactive and volatile elements, which have made conducting diamond anvil cell and x-ray diffraction experiments a challenge. Here, we use ab initio methods to search for stable crystal structures of both elements at megabar pressures. We demonstrate how symmetry and geometric constraints can be combined to efficiently generate crystal structures that are composed of diatomic molecules. Furthermore, our algorithm extends the symmetry driven structure search method by adding constraints for the bond length and the number of atoms in a molecule while still maintaining generality. As a method of validation, we have tested our approach for dense hydrogen and reproduced the known molecular structures of Cmca-12 and Cmca-4. We apply our algorithm to study chlorine and fluorine in the pressure range of 10 GPa–4000 GPa while considering crystal structures with up to 40 atoms per unit cell. We predict chlorine to follow the same series of phase transformations as elemental iodine from Cmca to Immm to Fm3¯m, but at substantially higher pressures. We predict fluorine to transition from a C2/c to Cmca structure at 70 GPa, to a novel orthorhombic and metallic structure with P42/mmc symmetry at 2500 GPa, and finally to its cubic analog form with Pm3¯n symmetry at 3000 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro-Quantification of Helium-3 and Helium-4 in TPBAR Components

This report documents the method development for measuring helium isotopes in micrometer-sized samples of tritium producing burnable absorption rod (TPBAR) components. Helium isotopes were measured as a tracer for tritium, which decays to 3 He with a half-life of 12.33 years. Getter and cladding materials from the TPBARs were analyzed, as they are designed to trap tritium. Therefore, constraining the diffusivity of tritium through these materials is of key importance. To first establish the reliability of the noble gas mass spectrometer, a reference gas with a relative 4 He/ 3 He ratio of 1000 was pre-mixed. This standard was measured several times to ensure measurements were reproducible. Unirradiated and irradiated getter and cladding samples of TPBARs were cut into 1-100 µm 3 cubes and analyzed for 3 He and 4 He content. The unirradiated materials had helium content equal to or less than that of the measured instrument background. Irradiated cladding also had instrument background levels of helium while irradiated getters had elevated levels of 3 He, interpreted to be the decay product of tritium. No diffusion of 4 He was observed in any of these materials, however, indicating that the 3 He detected in the irradiated getter was produced in situ after tritium diffusion and decay. These findings validate this method as a way to trace tritium diffusion in reactor materials.

07 ISOTOPE AND RADIATION SOURCES↗

Kinetic simulation of a low-pressure helium discharge with comparison to experimental measurements

Modern computational validation efforts rely on comparison of known experimental quantities such as current, voltage, particle densities, and other plasma properties with the same values determined through simulation. A discrete photon approach for radiation transport was recently incorporated into a particle-in-cell/direct simulation Monte Carlo code. As a result, spatially and temporally resolved synthetic spectra may be generated even for non-equilibrium plasmas. The generation of this synthetic spectra lends itself to potentially new validation opportunities. In this work, initial comparisons of synthetic spectra are made with experimentally gathered optical emission spectroscopy. A custom test apparatus was constructed that contains a 0.5 cm gap distance parallel plane discharge in ultra high purity helium gas (99.9999%) at a pressure of 75 Torr. Plasma generation is initiated with the application of a fast rise-time, 100 ns full-width half maximum, 2.0 kV voltage pulse. Transient electrical diagnostics are captured along with time-resolved emission spectra. A one-dimensional simulation is run under the same conditions and compared against the experiment to determine if sufficient physics are included to model the discharge. To sync the current measurements from experiment and simulation, significant effort was undertaken to understand the kinetic scheme required to reproduce the observed features. Additionally, the role of the helium molecule excimer emission and atomic helium resonance emission on photocurrent from the cathode are studied to understand which effect dominates photo-feedback processes. Results indicate that during discharge development, atomic helium resonance emission dominates the photo-flux at the cathode even though it is strongly self-absorbed. A comparison between the experiment and simulation demonstrates that the simulation reproduces observed features in the experimental discharge current waveform. Here, the synthesized spectra from the kinetic method produces more favorable agreement with the experimental data than a simple local thermodynamic equilibrium calculation and is a first step towards using spectra generated from a kinetic method in validation procedures. The results of this study produced a detailed compilation of important helium plasma chemistry reactions for simulating transient helium plasma discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional simulations of reshocked inclined Richtmyer-Meshkov instability: Effects of initial perturbations

The effect of initial perturbations on the evolution of the inclined Richtmyer-Meshkov turbulent mixing layer before and after reshock initiated by a shock wave with Mach number 1.55 is investigated through three-dimensional (3D) simulations using the flash code. The 3D simulations aim to reproduce both predominantly single-mode and multimode interfaces between light and heavy gases (N 2 -CO 2 , Atwood number, A≈0.22; amplitude to wavelength ratio of 0.088) which were created in an inclined shock tube facility to analyze the effects of initial conditions on mixing development in the entire flow field. The two-dimensional center slices of 3D simulations are compared with the experimental results to validate the computational code. Mixing width, mixed mass, mixed-mass thickness, and circulation in addition to concentration fields are shown to be in good agreement with the experimental data. The three-dimensional density and vorticity fields are first presented to qualitatively describe the flow behavior before and after reshock. Several measured density/velocity-related quantities indicate that the growth of the mixing material is strongly dependent on initial conditions. Before reshock and at early times after reshock, flow is clearly maintaining the memory of initial perturbations. However, at late time after reshock, although the large wavelength feature still dominates the flow motion, and the morphology of the two different interfaces indicates several differences, by breakdown of large-scale coherent structures to much finer scales, the memory of small scales of the multimode initial perturbation is not as clear as pre-reshock. Regarding three-dimensionality of the flow, before reshock in the multimode case, the baroclinic vorticity production, circulation, turbulent kinetic energy, and turbulent mass flux suggest that the small-scale roll-up features along the large inclined wavelength quickly evolves in all three dimensions. The coherent vortex tubes break down to smaller wormlike vortex structures, and turbulent fluctuations in the out-of-plane dimension are comparable to the spanwise direction. After reshock, this three-dimensionality of mixing growth was observed in the flow for both initial conditions. The results of this work represent a significant extension of previous computational studies performed on this specific topic. A different code with a different numerical method is validated through comparison with the experimental data. The initial perturbations are directly measured from the experimental results. Moreover, the entire three-dimensional experimental shock tube domain is simulated, and more quantities are investigated to understand the mixing mechanism and instability evolution in all three dimensions.

42 ENGINEERING↗

A novel lateral disequilibrium inclusive (LDI) pencil-beam based dose calculation algorithm: Evaluation in inhomogeneous phantoms and comparison with Monte Carlo calculations

Purpose: Pencil-beam (PB) based dose calculation for treatment planning is limited by inaccuracies in regions of tissue inhomogeneities, particularly in situations with lateral electron disequilibrium as is present at tissue/lung interfaces. To overcome these limitations, a new ''lateral disequilibrium inclusive'' (LDI) PB based calculation algorithm was introduced. In this study, the authors evaluated the accuracy of the new model by film and ionization chamber measurements and Monte Carlo simulations. Methods: To validate the performance of the new LDI algorithm implemented in Corvus 09, eight test plans were generated on inhomogeneous thorax and pelvis phantoms. In addition, three plans were calculated with a simple effective path length (EPL) algorithm on the inhomogeneous thorax phantom. To simulate homogeneous tissues, four test plans were evaluated in homogeneous phantoms (homogeneous dose calculation). Results: The mean pixel pass rates and standard deviations of the gamma 4%/4 mm test for the film measurements were (96{+-}3)% for the plans calculated with LDI, (70{+-}5)% for the plans calculated with EPL, and (99{+-}1)% for the homogeneous plans. Ionization chamber measurements and Monte Carlo simulations confirmed the high accuracy of the new algorithm (dose deviations {<=}4%; gamma 3%/3 mm {>=}96%)Conclusions: LDI represents an accurate and fast dose calculation algorithm for treatment planning.

60 APPLIED LIFE SCIENCES↗