Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Fractional laser microablation of skin: increasing the efficiency of transcutaneous delivery of particles

We study several regimes of fractional laser microablation using a pulsed Er : YAG laser for producing microchannels of different depth and incisions that allow transcutaneous delivery of particles of different size, namely, Al{sub 2}O{sub 3} (27 μm), ZrO{sub 2} (smaller than 5 μm) and TiO{sub 2} (smaller than 100 nm). The shock wave regime was used both for enhancing the penetration of particles into the ablation zones and as an independent method of particle delivery into the skin. Based on optical coherence tomography we assessed the coherent depth of particle detection in the skin in 2 hours, 3 days and 10 days after the administration. The maximal localisation depth (up to 450 μm) was obtained for TiO{sub 2} nanoparticles in the regime of incisions with enhancement of particle penetration by pulses of a multiple-beam hydrodynamic shock wave. The results of the study can be useful for developing new methods of transcutaneous delivery of micro- and nanocarriers of medicinal preparations. (laser biophotonics)

36 MATERIALS SCIENCE↗

Microsecond acquisition of heterogeneous structure in the folding of a TIM barrel protein

The earliest kinetic folding events for ({beta}{alpha}){sub 8} barrels reflect the appearance of off-pathway intermediates. Continuous-flow microchannel mixing methods interfaced to small-angle x-ray scattering (SAXS), circular dichroism (CD), time-resolved Foerster resonant energy transfer (trFRET), and time-resolved fluorescence anisotropy (trFLAN) have been used to directly monitor global and specific dimensional properties of the partially folded state in the microsecond time range for a representative ({beta}{alpha}){sub 8} barrel protein. Within 150 {micro}s, the {alpha}-subunit of Trp synthase ({alpha}TS) experiences a global collapse and the partial formation of secondary structure. The time resolution of the folding reaction was enhanced with trFRET and trFLAN to show that, within 30 {micro}s, a distinct and autonomous partially collapsed structure has already formed in the N-terminal and central regions but not in the C-terminal region. A distance distribution analysis of the trFRET data confirmed the presence of a heterogeneous ensemble that persists for several hundreds of microseconds. Ready access to locally folded, stable substructures may be a hallmark of repeat-module proteins and the source of early kinetic traps in these very common motifs. Their folding free-energy landscapes should be elaborated to capture this source of frustration.

59 BASIC BIOLOGICAL SCIENCES↗

High-temperature oxidation of transient-liquid phase bonded Ni-based alloys in 1 bar and 250 bar carbon dioxide

Compact microchannel heat exchanger designs for supercritical CO 2 power cycles are valued for equipment size reduction and increased heat transfer. They can be fabricated via transient-liquid phase (TLP) bonding, which utilizes a lower melting point interlayer for bonding facilitation of etched thin plates. Haynes 230 and 282 TLP bonded stacks were exposed to high-purity CO 2 at 1 bar/700 °C to 4000 h and 250 bar/720 °C (supercritical) to 1500 h. All samples obeyed parabolic kinetics after an oxide buildup stage of 500-1000 h. Mass gains were similar for the base and TLP bonded alloys, and oxide thicknesses and scales did not significantly differ around the TLP bond regions. Furthermore, there were some slight oxide compositional differences for the H282 TLP samples at 250 bar. There was a slight pressure effect on mass gain, as samples exposed at the higher pressure experienced higher initial mass gains, but then slower continued oxide growth.

36 MATERIALS SCIENCE↗

Microfluidic cells for the 1–10 2 MPa pressure range

Thin membrane-delimited fluid cells supporting up to 1 at (0.1 MPa) of pressure are well known and commercially available for use in vacuum chambers of electron, photon, or various particle beam microscopies or spectroscopies. Hereby, we report on the development of fluid cells capable of working at 1–10 MPa, extending the analysis domain for investigating chemical, biochemical, or physical processes at pressures of interest in chemical synthesis, underwater biochemistry studies or underground geology. We explored ways to optimize cell membranes to better resist pressure beyond simply increasing the thickness or decreasing the size of the membranes, using finite element analysis and experimental validation via membrane bulging experiments and failure statistics. Fluid cell prototypes were fabricated using ∼75 nm-thick SiN x membranes, engineered to withstand 4.7 MPa (average value), compared to regular (un-engineered) membranes withstanding only 3.4 MPa (average value). The fluid cell prototypes include eight microchannels for feeding/evacuating the fluids and applying pressure into micro-reaction chambers, two electrodes for electrochemical or conduction measurements in the sample, and a possible pressure or temperature sensor, customizable for specific experiments.

hi-pressure↗

Study of SXR/EUV radiation of exploded foils and wires with spectral, spatial and temporal resolution simultaneously on KING electric discharge facility.

The results of studies of the soft X-ray and extreme ultraviolet (SXR/EUV) radiation of thin flat aluminum foils and wires under the explosion in an electric discharge on the compact high-current KING generator are presented. These studies were based on the SXR/EUV spectroscopy with a spectral resolution of 6 Å, a temporal resolution of 5 ns and a spatial resolution of 200 μm. To study the plasma radiation of exploded foils and wires in the SXR/EUV range, we used a transmission diffraction grating spectrograph which in combination with two additional slits provided spectral and spatial resolution. The spectrograph was coupled with a 4-frame recorder based on a microchannel plate for providing temporal resolution. The analysis and comparison of the spectral, spatial, temporal, and energy characteristics of the SXR/EUV radiation of plasma formed under the explosion of foils and wires of a similar mass made of aluminum was carried out. Here, the spectra were calculated as well and the plasma parameters and their changes in time and space were estimated on the basis of these calculations and comparison with relevant experimental results. Experiments have shown that when foils explode, a single intense source of SXR/EUV radiation is formed with radiated energy in the range of 10-20 J and a power of up to 100 MW in the quantum energy range from 30 to 250 eV. At the same time, the radiation power under the explosion of foils turned out to be about twice above the power under the explosion of wires of comparable mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupling of electroelastic dynamics and direct contact ultrasonic drying formulation for annular piezoelectric bimorph transducers

A newly developed technique for drying clothes without thermal energy has been developed through the utilization of ultrasonic vibrations from piezoelectric transducers. The novel technique incorporates the actuation of a thin stainless steel disk in contact with wet fabric via annular piezoelectric rings, where water in the liquid form is atomized, transported through microchannels in the disk, and ejected as a mist. In such a system, resonance matching between the actuation portion of the transducer and the portion contacting fabric must be realized, with theoretical results from the developed electromechanical model showing a reduction in energy consumption by 50% when resonance matching is achieved. The electrically coupled distributed parameter model for an annular bimorph piezoelectric transducer is developed for optimization of ultrasonic drying technology. The thickness mode vibrations are shown to dominate the behavior of the system, where the analytically developed model can be optimized to increase the output acceleration of the transducer, thus increasing drying performance. Here, the electromechanical equation developed will be connected to the drying rates of fabrics in contact with said vibrations, where the novelty of the coupled equations and its description of the physics of ultrasonic drying will be discussed.

36 MATERIALS SCIENCE↗

MCP-PMT studies at the High-B test facility at Jefferson Lab

Here we present preliminary results for the gain performance of commercially available 3- mum and 6- mum pore-size single-anode microchannel-plate photomultipliers (MCP PMTs) in magnetic fields up to 5 T and for various orientations of the sensor relative to the field direction. The measurements were performed at Thomas Jefferson National Accelerator Facility in Newport News, VA. Our results show that smaller-pore-size PMTs have better gain performance in magnetic fields. At various angles, the shape of the gain dependence on the strength of the magnetic field strongly depends on the type of the sensor. Also, for each sensor, the azimuthal dependence is strongly correlated with the polar angle. Overall, the sensors exhibit a reasonable performance up to 2 T, although that upper limit depends on the sensor, the applied high voltage, and the orientation of the sensor relative to the field. To optimize the operational and design parameters of MCP PMTs for performance in high magnetic fields, further measurements and simulation studies will be pursued. Furthermore, our studies are part of an R&D for development of a Detector of Internally Reflected Cherenkov Light for the central detector of a future U.S. Electron Ion Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

Deep learning-based spatiotemporal multi-event reconstruction for delay line detectors

Abstract Accurate observation of two or more particles within a very narrow time window has always been a challenge in modern physics. It creates the possibility of correlation experiments, such as the ground-breaking Hanbury Brown–Twiss experiment, leading to new physical insights. For low-energy electrons, one possibility is to use a Microchannel plate with subsequent delay lines for the readout of the incident particle hits, a setup called a Delay Line Detector. The spatial and temporal coordinates of more than one particle can be fully reconstructed outside a region called the dead radius. For interesting events, where two electrons are close in space and time, the determination of the individual positions of the electrons requires elaborate peak finding algorithms. While classical methods work well with single particle hits, they fail to identify and reconstruct events caused by multiple nearby particles. To address this challenge, we present a new spatiotemporal machine learning model to identify and reconstruct the position and time of such multi-hit particle signals. This model achieves a much better resolution for nearby particle hits compared to the classical approach, removing some of the artifacts and reducing the dead radius a factor of eight. We show that machine learning models can be effective in improving the spatiotemporal performance of delay line detectors.

Computer Science↗

A novel two-layer-integrated microfluidic device for high-throughput yeast proteomic dynamics analysis at the single-cell level

Abstract Current microfluidic methods for studying multicell strains (e.g., m-types) with multienvironments (e.g., n-types) require large numbers of inlets/outlets (m*n), a complicated procedure or expensive machinery. Here, we developed a novel two-layer-integrated method to combine different PDMS microchannel layers with different functions into one chip by a PDMS through-hole array, which improved the design of a PDMS-based microfluidic system. Using this method, we succeeded in converting 2 × m × n inlets/outlets into m + n inlets/outlets and reduced the time cost of loading processing (from m × n to m) of the device for studying multicell strains (e.g., m-types) in varied multitemporal environments (i.e., n-types). Using this device, the dynamic behavior of the cell-stress-response proteins was studied when the glucose concentration decreased from 2% to a series of lower concentrations. Our device could also be widely used in high-throughput studies of various stress responses, and the new concept of a multilayer-integrated fabrication method could greatly improve the design of PDMS-based microfluidic systems.

Chen, Kaiyue↗

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

β -Nuclear-Recoil Correlation from $^6$$\mathrm{He}$ Decay in a Laser Trap

Here, we report the first precise measurement of a β-recoil correlation from a radioactive noble gas ( 6 He) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield |C T /C A | 2 ≤ 0.022 (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are 0.007 < C T /C A < 0.111 (90% C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the microchannel plate used for recoil ion detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conjugate Heat Transfer Analysis of the Supercritical CO2 Based Counter Flow Compact 3D Heat Exchangers

Compact heat exchangers using supercritical fluids such as CO2 are preferred due to their high heat transfer capacity and smaller footprint. Three-dimensional conjugate forced convection heat transfer analysis was performed on several shell-and-tube counter-flow microchannel heat exchangers. Numerical simulations were conducted to test effect of change in mass flow rate, hydraulic diameter and various cross sections on the heat transfer. Increasing mass flow rate improved heat transfer up to a maximum value and then decreased downstream with increasing turbulence. Maximum heat transfer was obtained for the micro channel with the smallest hydraulic diameter. Amongst the cross sections analyzed (circular, square, circular with radial ribs, and square with radial ribs), the most uniform distribution of temperature and maximum heat transfer were obtained for circular cross section with radial ribs. An optimally efficient operation of such a heat exchanger can be attained by considering these factors during multi-objective constrained optimization of geometric parameters and requirements for additive manufacturing of such compact heat exchangers.

Chitale, Janhavi↗

A design for large-area fast photo-detectors with transmission-line readout and waveform sampling.

We present a preliminary design and the results of simulation for a photo-detector module to be used in applications requiring the coverage of areas of many square meters with time resolutions less than 10 picoseconds and position resolutions of less than a millimeter for charged particles. The source of light is Cherenkov light in a radiator/window; the amplification is provided by panels of micro-pores functionalized to act as microchannel plates (MCPs). The good time and position resolution stems from the use of an array of parallel 50 Omega transmission lines (strips) as the collecting anodes. The anode strips feed multi-GS/sec sampling chips which digitize the pulse waveform at each end of the strip, allowing a measurement of the time from the average of the two ends, and a 2-dimensional position measurement from the difference of times on a strip, and, in the orthogonal direction, the strip number, or a centroid of the charges deposited on adjacent strips. The module design is constructed so that large areas can be 'tiled' by an array of modules.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A rational asymmetric hollow fiber membrane for oxygen permeation

Abstract A typical oxygen permeation hollow fiber membrane fabricated by phase inversion‐based extrusion process demonstrates heterogeneous porous microstructures, in which the surface layer with relatively low porosity is used as a separation layer after sintering. It is usually not convenient to control the thickness of separation layer. And a high sintering temperature is needed to densify the separation layer, which in turn could destroy the desired porous microstructures in other portion. This paper studies a novel process to fabricate multilayer asymmetric hollow fiber membrane with a rational design using 67 vol. % Gd 0.2 Ce 0.8 O 2−δ −33 vol. % La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3−δ ( GDC ‐ LSCF ) as a model material system. The phase inversion‐based extrusion process in open literature is employed to fabricate a hollow fiber substrate featuring radially well‐aligned microchannels open at the inner surface. Built upon the hollow fiber substrate, a thin dense separation layer and porous surface catalyst layer at shell side are then fabricated through dip‐coating and sintering process alternatively. The oxygen permeation flux of the fabricated hollow fiber membrane reaches 2.68 mL/cm 2 /min at 900°C under Ar/air gradient, the highest performance of the membranes with GDC ‐ LSCF material system in open literature. The innovative fabrication process is able to readily control the thickness of functional layers while decreasing sintering temperatures.

Ren, Chunlei↗

History of the Fluids Engineering Division

The 90th Anniversary of the Fluids Engineering Division (FED) of ASME will be celebrated on July 10–14, 2016 in Washington, DC. The venue is ASME's Summer Heat Transfer Conference (SHTC), Fluids Engineering Division Summer Meeting (FEDSM), and International Conference on Nanochannels and Microchannels (ICNMM). The occasion is an opportune time to celebrate and reflect on the origin of FED and its predecessor—the Hydraulic Division (HYD), which existed from 1926–1963. Furthermore, the FED Executive Committee decided that it would be appropriate to publish concurrently a history of the HYD/FED.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PhaseChange Material Freezing in an Energy Storage Module for a Micro Environmental ControlSystem

This study analyzes phase change material (PCM) freezing process in a novel latent heat storage device (LHSD). Heat is removed from the PCM with an embedded evaporator. A mathematical model of freezing in a finite-thickness PCM slab is presented. An experimentally validated reduced-order model (ROM) based on the mathematical model was developed to analyze the heat transfer between the freezing PCM and an evaporating refrigerant flowing inside a flat, microchannel tube coil embedded in the PCM. A detailed finite element model (FEM) of the same device was also developed and employed to verify the validity of the ROM over a wider range of conditions. The freezing times and total “cooling” stored in the PCM computed by the ROM agree very well with those computed by the detailed FEM. The ROM executes in ~1 min for a full heat exchanger, compared with more than 10 h for the FEM, making the former much more practical for use in parametric analysis and optimization of design alternatives.

Engineering↗

Liquid-Cooled Aluminum Silicon Carbide Heat Sinks for Reliable Power Electronics Packages

With recent advances in the state-of-the-art of power electronic devices, packaging has become one of the critical factors limiting the performance and durability of power electronics. To this end, this study investigates the feasibility of a novel integrated package assembly, which consists of copper circuit layer on an aluminum nitride (AlN) dielectric layer that is bonded to an aluminum silicon carbide (AlSiC) substrate. The entire assembly possesses a low coefficient of thermal expansion (CTE) mismatch which aids in the thermal cycling reliability of the structure. The new assembly can serve as a replacement for the conventionally used direct bonded copper (DBC) - Cu base plate - Al heat sink assembly. While improvements in thermal cycling stability of more than a factor of 18 has been demonstrated, the use of AlSiC can result in increased thermal resistance when compared to thick copper heat spreaders. To address this issue, we demonstrate that the integration of single phase liquid cooling in the AlSiC layer can result in improved thermal performance, matching that of copper heat spreading layers. This is aided by the use of heat transfer enhancement features built into the AlSiC layer. It is found that, for a given pumping power and through analytical optimization of geometries, either microchannels, pin fins and jets can be designed to yield a heat transfer coefficients of up to 65000 W m -2 K -1 , which can result in competitive device temperatures as Cu-baseplate designs, but with added reliability.

30 DIRECT ENERGY CONVERSION↗