Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

SU-E-T-90: Accuracy of Calibration of Lithium-6 and -7 Enriched LiF TLDs for Neutron Measurements in High Energy Radiotherapy

Purpose: To determine the potential error involved in the interpretation of neutron measurements from medical linear accelerators (linacs) using TLD-600H and TLD-700H if standard AmBe and {sup 252}Cf neutron sources are used for calibration without proper inclusion of neutron energy spectrum information. Methods: The Kerma due to neutrons can be calculated from the energy released by various nuclear interactions (elastic and inelastic scatter, (n,α), (n,p), (n,d), (n,t), (n,2n), etc.). The response of each TLD can be considered the sum of the neutron and gamma components; each proportional to the Kerma. Using the difference between the measured TLD responses and the ratio of the calculated Kerma for each material, the neutron component of the response can be calculated. The Monte Carlo code MCNP6 has been used to calculate the neutron energy spectra resulting from photonuclear interactions in a Varian 21EX linac. TLDs have been exposed to the mixed (γ-n) field produced by a linac and AmBe and {sup 252}Cf standard neutron sources. Results: For dosimetry of neutrons from AmBe or {sup 252}Cf sources, assuming TLD-700H insensitivity to neutrons will Result in 10% or 20% overestimation of neutron doses respectively.For dosimetry of neutrons produced in a Varian 21EX, applying a calibration factor derived from a standard AmBe or {sup 252}Cf source will Result in an overestimation of neutron fluence, by as much as a factor of 47.The assumption of TLD-700H insensitivity to neutrons produced by linacs leads to a negligible error due to the extremely high Kerma ratio (600H/700H) of 3000 for the assumed neutron spectrum. Conclusion: Lithium-enriched TLDs calibrated with AmBe and/or {sup 252}Cf neutron sources are not accurate for use under the neutron energy spectrum produced by a medical linear accelerator.

60 APPLIED LIFE SCIENCES↗

A Comparison of Neutron-Based Non-Destructive Assessment Methods for Chemical Warfare Materiel and High Explosives

Prompt Gamma Neutron Activation Analysis (PGNAA) systems employ neutrons as a probe to interrogate items, e.g. chemical warfare materiel-filled munitions. The choice of a neutron source in field-portable systems is determined by its ability to excite nuclei of interest, operational concerns such as radiological safety and ease-of-use, and cost. Idaho National Laboratory’s PINS Chemical Assay System has traditionally used a Cf-252 isotopic neutron source, but recently a Deuterium-Tritium (DT) Electronic Neutron Generator (ENG) has been tested as an alternate neutron source. This paper presents the results of using both of these neutron sources to interrogate chemical warfare materiel (CWM) and high explosive (HE) filled munitions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Multi-Step CADIS Method for Shutdown Dose Rate Calculations and Uncertainty Propagation - Paper 137

The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid MC/deterministic method has been proposed to speed up the SDDR MC neutron transport calculation using an importance function that represents the neutron importance to the final SDDR. This paper provides some valuable insights regarding the MS-CADIS method, including physical interpretations of the MS-CADIS adjoint neutron source and the MS-CADIS adjoint neutron flux. The paper also describes the feasibility of using the MS-CADIS adjoint neutron source to calculate the SDDR uncertainty resulting from uncertainties in the MC neutron calculation. A companion paper will provide numerical results that demonstrate the effectiveness of the MS-CADIS method in speeding up SDDR MC simulations and in calculating SDDR uncertainties for problems related to fusion energy systems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Weekly Update - LANSCE Neutron Spectrum Characterization

Preparations for characterizing the energy spectrum of the LANSCE neutron source have been made. The spallation neutron source at the Los Alamos Neutron Science Center (LANSCE) produces a white spectrum of neutrons with energies between about 100 keV to greater than 600 MeV. Recently, an effort to radiograph dense objects has been stood up at the Weapons Neutron Research (WNR) facility at LANSCE. However, the spallation process as well as some target-cooling techniques can create high gamma fluxes. The gamma- and neutron-energy spectrum of the source influence the quality of the radiographs that can be made with the source. Additionally, models of the source are essential to interpreting radiographs made with it, and experimental constraints on the gamma- and neutron-energy spectrum of the source will greatly increase the fidelity of these models. The gamma- and neutron-energy spectrum of the LANSCE source can be constrained in the ~10-MeV to ~100-MeV range through measurements of threshold reactions on bismuth foils. The decay of the activation products of the (n,Xn) and (γ,Xn) reactions can be measured, and, using the known cross sections for these reactions, the spectral content of the beam can be inferred. Many of these activation products decay via γ-ray emission, so measuring these decays requires High-Purity Germanium (HPGe) detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORNL Neutron Sciences Annual Report for 2007

This is the first annual report of the Oak Ridge National Laboratory Neutron Sciences Directorate for calendar year 2007. It describes the neutron science facilities, current developments, and future plans; highlights of the year's activities and scientific research; and information on the user program. It also contains information about education and outreach activities and about the organization and staff. The Neutron Sciences Directorate is responsible for operation of the High Flux Isotope Reactor and the Spallation Neutron Source. The main highlights of 2007 were highly successful operation and instrument commissioning at both facilities. At HFIR, the year began with the reactor in shutdown mode and work on the new cold source progressing as planned. The restart on May 16, with the cold source operating, was a significant achievement. Furthermore, measurements of the cold source showed that the performance exceeded expectations, making it one of the world's most brilliant sources of cold neutrons. HFIR finished the year having completed five run cycles and 5,880 MWd of operation. At SNS, the year began with 20 kW of beam power on target; and thanks to a highly motivated staff, we reached a record-breaking power level of 183 kW by the end of the year. Integrated beam power delivered to the target was 160 MWh. Although this is a substantial accomplishment, the next year will bring the challenge of increasing the integrated beam power delivered to 887 MWh as we chart our path toward 5,350 MWh by 2011.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Student Progress Report: Summer 2012 [Slides]

The Los Alamos SOURCES 4C code has been benchmarked for alpha particle beam problems and common neutron source materials (e.g. those containing plutonium or beryllium), but little benchmarking has been performed for more exotic isotopic neutron sources or uranium mixtures. This work extends SOURCES 4C benchmarking effort. Experimental data was found in the literature for several isotopic neutron sources, namely Am/Be, Am/F, Am/B, Cm/Be, 238 Pu/ 13 C, 252 Cf, and Am/Li.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DEVELOPMENT OF THE SNS EXTERNAL ANTENNA H- ION SOURCE

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility currently in the process of ramping up neutron production. To meet present and future beam current and reliability requirements we are developing an RF-driven, H- ion source based on a ceramic aluminium nitride (AlN) plasma chamber surrounded by an external RF antenna. This report recounts the design of the prototype source, describes the Cs collar variations tested, enumerates recent modifications made to the source to prepare a production version, and summarizes the results of runs on the SNS test stand and Front End (FE) of the SNS accelerator. Up to ~100 mA unanalyzed beam currents (60Hz, 1ms) have been measured on the SNS ion source test stand, and up to 42mA have been successfully accelerated by the RFQ on the SNS front-end at lower RF power.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The GUINEVERE experiment: First PNS measurements in a lead moderated sub-critical fast core

The GUINEVERE (Generation of Uninterrupted Intense Neutrons at the lead Venus Reactor) experimental program is dedicated to the study of Accelerator Driven System reactivity monitoring. It was partly carried out within the EUROTRANS integrated project (EURATOM FP6). GUINEVERE consists in coupling the fast core of the VENUS-F reactor (SCK-CEN, Mol (Belgium)), composed of enriched uranium and solid lead, with a T(d,n) neutron source provided by the GENEPI-3C deuteron accelerator. This neutron source can be operated in several modes: pulsed mode, continuous mode and also continuous mode with short beam interruptions (the so called 'beam trips'). In the past, the key questions of the reactivity control and monitoring in a subcritical system were studied in the MUSE experiments (1998-2004). These experiments highlighted the difficulty to determine precisely the reactivity with a single technique. This led to investigate a new strategy which is based on the combination of the relative reactivity monitoring via the core power to beam current relationship with absolute reactivity cross-checks during programmed beam interruptions. Consequently, to determine the reactivity, several dynamical techniques of reactivity determination have to be compared. In addition, their accuracy for absolute reactivity determination must be evaluated using a reference reactivity determination technique (from a critical state: rod drop and MSM measurements). The first sub-critical configuration which was studied was around k{sub eff} = 0.96 (SCI). Pulsed Neutron Source experiments (PNS) were carried out. The neutron population decrease was measured using fission chambers in different locations inside the core and the reflector. Neutron population time decrease was analyzed using fitting techniques and the Area Method Results obtained for the SCI reactivity will be shown, discussed and compared to the reference value given by the MSM method. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-21: A D-D Based Neutron Generator System for Boron Neutron Capture Therapy: A Feasibility Study

Purpose: To investigate the feasibility of a deuterium-deuterium (DD) neutron generator for application in boron neutron capture therapy (BNCT) of brain cancer Methods: MCNP simulations were performed using a head phantom and a monoenergetic neutron source, which resembles the point source in a DD generator that emits 2.45-MeV neutrons. Source energies ranging from 5eV to 2.45MeV were simulated to determine the optimal treatment energy. The phantom consisted of soft tissue, brain tissue, skull, skin layer, and a brain tumor of 5 cm in diameter. Tumor depth was varied from 5–10 cm. Boron-10 concentrations of 10 ppm, 15 ppm, and 30 ppm were used in the soft/brain tissues, skin, and tumor, respectively. The neutron flux required to deliver 60 Gy to the tumor as well as the normal tissue doses were determined. Results: Beam energies between 5eV and 10keV obtained doses with the highest dose ratios (3.3–25.9) between the tumor and the brain at various depths. The dose ratio with 2.45-MeV neutrons ranged from 0.8–6.6. To achieve the desired tumor dose in 40 minutes, the required neutron flux for a DD generator was between 8.8E10 and 5.2E11 n/s and the resulting brain dose was between 2.3 and 18 Gy, depending on the tumor depth. The skin and soft tissue doses were within acceptable tolerances. The boron-neutron interaction accounted for 54–58% of the total dose. Conclusion: This study shows that the DD neutron generator can be a feasible neutron source for BNCT. The required neutron flux for treatment is achievable with the current DD neutron technology. With a well-designed beam shaping assembly and treatment geometry, the neutron flux can be further improved and a 60-Gy prescription can be accurately delivered to the target while maintaining tolerable normal tissue doses. Further experimental studies will be developed and conducted to validate the simulation results.

60 APPLIED LIFE SCIENCES↗

NOVEL CRYOGENIC ENGINEERING SOLUTIONS FOR THE NEW AUSTRALIAN RESEARCH REACTOR OPAL

In August 2006 the new 20MW low enriched uranium research reactor OPAL went critical. The reactor has 3 main functions, radio pharmaceutical production, silicon irradiation and as a neutron source. Commissioning on 7 neutron scattering instruments began in December 2006. Three of these instruments (Small Angle Neutron Scattering, Reflectometer and Time-of-flight Spectrometer) utilize cold neutrons.The OPAL Cold Neutron Source, located inside the reactor, is a 20L liquid deuterium moderated source operating at 20K, 330kPa with a nominal refrigeration capacity of 5 kW and a peak flux at 4.2meV (equivalent to a wavelength of 0.4nm). The Thermosiphon and Moderator Chamber are cooled by helium gas delivered at 19.8K using the Brayton cycle. The helium is compressed by two 250kW compressors (one with a variable frequency drive to lower power consumption).A 5 Tesla BSCCO (2223) horizontal field HTS magnet will be delivered in the 2{sup nd} half of 2007 for use on all the cold neutron instruments. The magnet is cooled by a pulse tube cryocooler operating at 20K. The magnet design allows for the neutron beam to pass both axially and transverse to the field. Samples will be mounted in a 4K to 800K Gifford-McMahon (GM) cryofurnace, with the ability to apply a variable electric field in-situ. The magnet is mounted onto a tilt stage. The sample can thus be studied under a wide variety of conditions.A cryogen free 7.4 Tesla Nb-Ti vertical field LTS magnet, commissioned in 2005 will be used on neutron diffraction experiments. It is cooled by a standard GM cryocooler operating at 4.2K. The sample is mounted in a 2{sup nd} GM cryocooler (4K-300K) and a variable electric field can be applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First 3{sup -} excited state of {sup 56}Fe

There is no reliable evidence for the existence of the 3.076 MeV (3{sup -}) level adopted in the ENSDF evaluation for {sup 56}Fe although it has been reported in a few experiments. Previous reports of the observation of this level appear to be based on an incorrect assignment in early (e,e{sup '}) work. Recent neutron inelastic scattering measurements by Demidov et al. [Phys. At. Nucl. 67, 1884, (2004)] show that the assigned {gamma}-ray decay of this state does not occur at a level consistent with known properties of inelastic scattering. In the present work the {sup 56}Fe(n,n{sup '}{gamma}) reaction was used to populate excited states in {sup 56}Fe. Neutrons in the energy range from 1 to 250 MeV were provided by the pulsed neutron source of the Los Alamos Neutron Science Center's WNR facility. Deexciting {gamma} rays were detected with the GEANIE spectrometer, a Compton suppressed array of 26 Ge detectors. The {gamma}-{gamma} data obtained with GEANIE were used to establish coincidence relations between transitions. All previously reported levels up to E{sub x}=3.6 MeV excitation energy were observed except for the 3.076 MeV (3{sup -}) level. The 991- and 2229-keV transitions, previously reported to deexcite this level, were not observed in the {gamma}-{gamma} coincidence data obtained in the present experiment. The present work supports the assignment of the 4509.6 keV level as the first 3{sup -} excited state in {sup 56}Fe by observation of two previously known transitions deexciting this state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Axisymmetric and Focusing Analyzers to Enable Efficient Powder and Residual Stress Neutron Diffractometers

Project Summary: Company: Adelphi Technology, Inc., Redwood City, CA 94063-4121 DOE Phase 1 STTR PI: Dr. Jay Theodore Cremer, Jr. Chief Scientist at Adelphi Technology, Inc. DOE Phase 1 STTR with: Dr. Boris Khaykovich of Massachusetts Institute of Technology (MIT) MIT Nuclear Reactor Laboratory DOE Phase 1 STTR Title: Axisymmetric and Focusing Analyzers to Enable Efficient Powder and Residual Stress Neutron Diffractometers Statement of the problem or situation that is being addressed: Although thermal and cold neutron scattering is widely used, and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed, so as to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed: We strive to achieve the goal of efficient use of available thermal and cold neutrons, by introducing here, novel analyzers for powder diffraction and stress-strain measurements. These analyzers will enable polychromatic cold and thermal neutron diffractometers, which will have much higher throughput than existing instruments. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast instruments for screening of multiple samples, for measuring kinetic processes, or for measuring residual stress tensors. Commercial Applications and Other Benefits: By combining the novel analyzers with the Adelphi thermal neutron generator, we will open a new market, which includes the testing of samples that cannot be transported, such as nuclear fuels, or the testing of parts during production. Given the reasonable cost and size of our proposed analyzer systems, along with the continuing development of more powerful thermal neutron generators, the proposed analyzers will be suitable for weak neutrons sources, which are installed at small to large university, industrial, and government laboratories. Key Words: Neutron powder diffraction, residual stress measurements, thermal neutron generators, TRIGA reactors, low flux thermal and cold neutron sources, neutron diffraction. Summary for Members of Congress: Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing a detection system for fissile material in nuclear disarmament verification

In arms control treaties, verification plays a crucial role in detecting non-compliance, deterring future violations, and building trust between state parties. Neutron interrogation that induces fission reactions in fissile isotopes and measures the resulting fission neutrons, could be employed for this purpose. This study aims to develop a system which can determine the presence of fissile material while intrinsically protecting information. In this paper, we focus on optimizing the system for discriminating between an enriched uranium block from a depleted uranium (DU) block. The system was built and we report on benchmark measurements with DU and 16% enriched uranium blocks. Furthermore, the Excalibur (Experiment for Calibration with Uranium) neutron source, a neutron spectrometer (redBubble Technology Industries (BTI) N-Probe), and superheated droplet detectors were used for these measurements. MCNP simulations provided insights into detector responses to fissile materials with varying isotopic compositions, confirming that the system functioned as designed.

Active neutron interrogation↗

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

97 MATHEMATICS AND COMPUTING↗

A Brief Survey of Data Streaming Technologies

Streaming data is data that is emitted at variable volumes in a continuous, incremental manner with the goal of low-latency processing often at a different physical location. Network infrastructure is used to facilitate the connection between data sources and sinks, and must be robust to handle the requirements of the workflow. The U.S. Department of Energy Office of Science (DOE SC) a federal agency supporting fundamental scientific research for energy and the Nation’s largest supporter of basic research in the physical sciences. DOE SC has the responsibility for operating $\mathbf{1 0}$ National Laboratories, and 28 scientific user facilities supporting advanced supercomputers, particle accelerators, large x-ray light sources, neutron scattering sources, and other specialized facilities for nanoscience and genomics. This paper investigates the state of streaming data workfows, and details some of the approaches to this challenging problem.

Kissel, Ezra↗

Fabrication and testing of high-performance all-metal neutron guides and axisymmetric mirrors by electrochemical replication

Neutron scattering is one of the most useful methods of studying the structure of matter, with applications to biomedical, structural, magnetic and energy-related materials. Neutron-scattering instruments are installed around research reactors or accelerator-based neutron sources, and neutron guides are critical components of these facilities. They are neutron-transport optical devices consisting of state-of-the-art mirrors often tens of meters long. Here we demonstrate a novel fabrication method of all-metallic neutron guides and axisymmetric mirrors by electroplating from precision mandrels. The process allows for the fabrication of single-piece all-metal guides of prismatic and axisymmetric shapes. We also demonstrate supermirror guides and axisymmetric focusing supermirrors produced with the same technology. We present the fabrication and tests of the multilayer-coated replicated guides and optic and show that the mandrel is reproduced with high fidelity and reliability. Furthermore, such supermirror optics will provide game-changing improvements in neutron techniques.

36 MATERIALS SCIENCE↗

Evaluation of LLNL's Personnel Nuclear Accident Dosimeter at the Silene Reactor (October 2009)

The Lawrence Livermore National Laboratory uses neutron activation elements in a Panasonic TLD holder as a personnel nuclear accident dosimeter (PNAD). The LLNL PNAD has periodically been tested using a Cf-252 neutron source, however it has been more than 25 years since the PNAD has been tested against a source of neutrons that arise from a reactor generated neutron spectrum that simulates a criticality. In October 2009, LLNL participated in an intercomparison of nuclear accident dosimeters with several other Department of Energy facilities. The reactor generated neutron irradiations were performed at the CEA Valduc Silene reactor. The current PNAD design at LLNL was developed in the early1980’s and evaluated in 1984 using neutron leakage spectra generated by the Health Physics Research Reactor at Oak Ridge National Laboratory. Fluence and dose conversion factors developed in 1984 have been adjusted to account for changes in measurement methods; however these factors continue to be the fundamental basis for determining dose using the current PNAD system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗