Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Advanced Three-Dimensional Display System

A desktop-scale, computer-controlled display system, initially developed for NASA and now known as the VolumeViewer(TradeMark), generates three-dimensional (3D) images of 3D objects in a display volume. This system differs fundamentally from stereoscopic and holographic display systems: The images generated by this system are truly 3D in that they can be viewed from almost any angle, without the aid of special eyeglasses. It is possible to walk around the system while gazing at its display volume to see a displayed object from a changing perspective, and multiple observers standing at different positions around the display can view the object simultaneously from their individual perspectives, as though the displayed object were a real 3D object. At the time of writing this article, only partial information on the design and principle of operation of the system was available. It is known that the system includes a high-speed, silicon-backplane, ferroelectric-liquid-crystal spatial light modulator (SLM), multiple high-power lasers for projecting images in multiple colors, a rotating helix that serves as a moving screen for displaying voxels [volume cells or volume elements, in analogy to pixels (picture cells or picture elements) in two-dimensional (2D) images], and a host computer. The rotating helix and its motor drive are the only moving parts. Under control by the host computer, a stream of 2D image patterns is generated on the SLM and projected through optics onto the surface of the rotating helix. The system utilizes a parallel pixel/voxel-addressing scheme: All the pixels of the 2D pattern on the SLM are addressed simultaneously by laser beams. This parallel addressing scheme overcomes the difficulty of achieving both high resolution and a high frame rate in a raster scanning or serial addressing scheme. It has been reported that the structure of the system is simple and easy to build, that the optical design and alignment are not difficult, and that the system can be built by use of commercial off-the-shelf products. A prototype of the system displays an image of 1,024 by 768 by 170 (=133,693,440) voxels. In future designs, the resolution could be increased. The maximum number of voxels that can be generated depends upon the spatial resolution of SLM and the speed of rotation of the helix. For example, one could use an available SLM that has 1,024 by 1,024 pixels. Incidentally, this SLM is capable of operation at a switching speed of 300,000 frames per second. Implementation of full-color displays in future versions of the system would be straightforward: One could use three SLMs for red, green, and blue, respectively, and the colors of the voxels could be automatically controlled. An optically simpler alternative would be to use a single red/green/ blue light projector and synchronize the projection of each color with the generation of patterns for that color on a single SLM.

Geng, Jason↗

Comparison of Simulated Contrast Performance of Different Phase Induced Amplitude Apodization (PIAA) Coronagraph Configurations

We compare the broadband contrast performances of several Phase Induced Amplitude Apodization (PIAA) coronagraph configurations through modeling and simulations. The basic optical design of the PIAA coronagraph is the same as NASA's High Contrast Imaging Testbed (HCIT) setup at the Jet Propulsion Laboratory (JPL). Using a deformable mirror and a broadband wavefront sensing and control algorithm, we create a "dark hole" in the broadband point-spread function (PSF) with an inner working angle (IWA) of 2(f lambda/D)(sub sky). We evaluate two systems in parallel. One is a perfect system having a design PIAA output amplitude and not having any wavefront error at its exit-pupil. The other is a realistic system having a design PIAA output amplitude and the measured residual wavefront error. We also investigate the effect of Lyot stops of various sizes when a postapodizer is and is not present. Our simulations show that the best 7.5%-broadband contrast value achievable with the current PIAA coronagraph is approximately 1.5x10(exp -8).

adaptive optics↗

A dark-field microscope for background-free detection of resonance fluorescence from single semiconductor quantum dots operating in a set-and-forget mode

Optically active quantum dots, for instance self-assembled InGaAs quantum dots, are potentially excellent single photon sources. The fidelity of the single photons is much improved using resonant rather than non-resonant excitation. With resonant excitation, the challenge is to distinguish between resonance fluorescence and scattered laser light. We have met this challenge by creating a polarization-based dark-field microscope to measure the resonance fluorescence from a single quantum dot at low temperature. We achieve a suppression of the scattered laser exceeding a factor of 10{sup 7} and background-free detection of resonance fluorescence. The same optical setup operates over the entire quantum dot emission range (920–980 nm) and also in high magnetic fields. The major development is the outstanding long-term stability: once the dark-field point has been established, the microscope operates for days without alignment. The mechanical and optical designs of the microscope are presented, as well as exemplary resonance fluorescence spectroscopy results on individual quantum dots to underline the microscope's excellent performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray spectrometer throughput model for (selected) flat Bragg crystal spectrometers on laser plasma facilities

At large laser faculties, such as OMEGA and the National Ignition Facility (NIF), x-ray spectrometers are provided by the facility to diagnose plasma conditions or monitor backlighters. Often the calibration of these spectrometers is unknown or out of date. In response to this situation, we present a simple ray trace method to calibrate flat crystal spectrometers using only basic information regarding the optical design of the spectrometer. This model is then used to output photometric throughput estimates, dispersion, solid angle, and spectral resolution estimates. This model is applied to the mono angle crystal spectrometer and Super Snout I at the NIF and the X-Ray Spectrometer at the OMEGA laser facility

47 OTHER INSTRUMENTATION↗

Second-Generation Multi-Angle Imaging Spectroradiometer

A report discusses an early phase in the development of the MISR-2 C, a second, improved version of the Multi-angle Imaging SpectroRadiometer (MISR), which has been in orbit around the Earth aboard NASA's Terra spacecraft since 1999. Like the MISR, the MISR-2 would contain a pushbroom array of nine charge-coupled- device (CCD) cameras one aimed at the nadir and the others aimed at different angles sideways from the nadir. The major improvements embodied in the MISR-2 would be the following: A new folded-reflective-optics design would render the MISR-2 only a third as massive as the MISR. Smaller filters and electronic circuits would enable a reduction in volume to a sixth of that of the MISR. The MISR-2 would generate images in two infrared spectral bands in addition to the blue, green, red, and near-infrared spectral bands of the MISR. Miniature polarization filters would be incorporated to add a polarization-sensing capability. Calibration would be performed nonintrusively by use of a gimbaled tenth camera. The main accomplishment thus far has been the construction of an extremely compact all-reflective-optics CCD camera to demonstrate feasibility.

Macenka, Steven↗

ISS Ammonia Leak Detection Through X-Ray Fluorescence

Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.

Camp, Jordan↗

Experimental Design for the LATOR Mission

This paper discusses experimental design for the Laser Astrometric Test Of Relativity (LATOR) mission. LATOR is designed to reach unprecedented accuracy of 1 part in 10(exp 8) in measuring the curvature of the solar gravitational field as given by the value of the key Eddington post-Newtonian parameter gamma. This mission will demonstrate the accuracy needed to measure effects of the next post-Newtonian order (near infinity G2) of light deflection resulting from gravity s intrinsic non-linearity. LATOR will provide the first precise measurement of the solar quadrupole moment parameter, J(sub 2), and will improve determination of a variety of relativistic effects including Lense-Thirring precession. The mission will benefit from the recent progress in the optical communication technologies the immediate and natural step above the standard radio-metric techniques. The key element of LATOR is a geometric redundancy provided by the laser ranging and long-baseline optical interferometry. We discuss the mission and optical designs, as well as the expected performance of this proposed mission. LATOR will lead to very robust advances in the tests of Fundamental physics: this mission could discover a violation or extension of general relativity, or reveal the presence of an additional long range interaction in the physical law. There are no analogs to the LATOR experiment; it is unique and is a natural culmination of solar system gravity experiments.

Turyshev, Slava G.↗

Crystal Growth of ZnSe and Related Ternary Compound Semiconductors by Vapor Transport

The objective of the project is to determine the relative contributions of gravity-driven fluid flows to the compositional distribution, incorporation of impurities and defects, and deviation from stoichiometry observed in the crystals grown by vapor transport as results of buoyance-driven convection and growth interface fluctuations caused by irregular fluid-flows. ZnSe and related ternary compounds, such as ZnSeS and ZnSeTe, were grown by vapor transport technique with real time in-situ non-invasive monitoring techniques. The grown crystals were characterized extensively to correlate the grown crystal properties with the growth conditions. The following are the research progress in the past two years. In-situ monitoring of partial pressure by optical absorption technique and visual observation of the growing crystal were performed during vapor growth of ZnSe. Low-temperature photoluminescence (PL) spectra and glow discharge mass spectroscopy (GDMS) were measured on ZnSe starting materials provided by various vendors and on bulk crystals grown from these starting materials by physical vapor transport (PVT) to study the effects of purification and contamination during crystal growth process. Optical characterization was performed on wafers sliced from the grown crystals of ZnSe, ZnTe and ZnSe(1-x),Te(x), (0<x<0.4). Energy band gaps at room temperature were determined from optical transmission measurements and a best fit curve to the band gap vs. composition, x, data gives a bowing parameter of 1.45. Low-temperature photoluminescence (PL) spectra of ZnSe and ZnTe were dominated by near band edge emissions and no deep donor-acceptor pairs were observed. The PL spectrum exhibited a broad emission for the ZnSe(1-x),Te(x), samples, 0.09<x<0.39. The single broad PL emission spectra and the spectra measured as a function of temperature were interpreted as being associated with the exciton bound to Te clusters because of the high Te content in these samples. To validate numerical codes, in-situ monitoring during the PVT of HgI2 was designed. Optical absorption spectra of the vapor phase over HgI2 were measured for wavelengths between 200 and 600nm at sample temperatures between 349 and 610K. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were determined. From these constants the vapor pressure of HgI2 was established as a function of temperature for the liquid and the solid Beta-phases To characterize the growth conditions during the PVT growth of In-doped ZnSe the optical absorbance of the vapor phase over the In-Se system were measured and were used to obtain the partial pressures of Se2(g) and In2Se(g).

Su, Ching-Hua↗

Evaluation of the interfacial bonding strength between hafnia and silica layers deposited by electron-beam evaporation

Factors contributing to the mechanical strength of multilayer optical coatings involving alternating layers of electron-beam evaporated hafnia and silica is investigated. It is observed that upon rupture resulting from nanosecond laser damage, fragments consisting of layer pairs are produced. These pairs are formed as a result of a strong asymmetry in adhesion strength between interfaces, leading to preferential delamination at interfaces where silica is deposited on hafnia, and not the reverse, despite the fact that both interface types consist of the same pair of materials. The observed disparity in adhesion strength was further studied using nanomechanical scratch tests, revealing loads at which fracture occurs, and fracture morphology, both of which are highly dependent on deposition order. Based on these measurements, along with the morphological analysis of the nanostructure of the coatings, we conclude that the surface microstructure in each coating layer affects its adhesion strength with the succeeding layer. The findings outlined here are particularly relevant to the production of large aperture, high-performance optics designed for use in next-generation lasers.

adhesion strength↗

Lunar Payloads to Constrain Exospheric Water through the NASA M-STAR program

Our understanding of water cycles on the Moon has significantly enhanced recent observations by Chang E-5, Lunar Prospector, and Chandrayaan-1 missions indicating the existence of an active water cycle on the Moon. In a new partnership between Delaware State University (DSU) and NASA Goddard Space Flight Center, enabled through the NASA’s M-STAR (MUREP Space Technology Artemis Research) program, we are developing low mass and power lunar rover payloads to enable long-duration human exploration missions. Payload technologies include wavelength modulation absorption spectroscopy to simultaneously detect water (H16OH) and isotopes (H16OD) in the (6700 nm) mid-infrared region using a closed path in compact Herriot cell optical design and wavelength modulation spectroscopy, and (2) Laser-induced breakdown spectroscopy (LIBS) to simultaneously detect and correlate water isotopes with characteristics elemental composition of lunar regolith. Due to the airless atmosphere of the Moon, we will utilize Artificial intelligence (AI) and Machine learning (ML) approaches to discriminate spectral interference with instrument drifts and correlate mid-IR trace gas profile with LIBS spectral information. This partnership will initiate a STEM engagement space program, e.g., Lander and CubeSat payload technology development for students and the next-generation NASA workforce for future lunar and Mars missions. DSU, a Historically Black University, prides itself in its proven excellence in teaching and research. It enrolls a diverse population of students (~5000) traditionally underrepresented in STEM disciplines. DSU has established itself at the forefront of optics and photonics research that transcends multidisciplinary fields of earth sciences, environmental, defense, and biomedical sensing applications.

water cycles↗

A Dispersive Backend Design for the 'Double-Fourier' Interferometer BETTII

BETTII (Balloon Experimental Twin Telescope for Infra-red Interferometry) is designed to provide high angular resolution spectroscopic data in the far-infrared (FIR) wavelengths. The most significant limitation for BETTII is its sensitivity; obtaining spectral signal-to-noise ratio greater than 5 in less than 10 minutes requires sources greater than 13 Janskys (Jy). One possible way to improve the signal-to-noise ratio (SNR) for future BETTII flights is by reducing the spectral bandwidth post beam-combination. This involves using a dispersive element to spread out a polychromatic point source PSF (Point Spread Function) on the detector array, such that each pixel corresponds to a small fraction of the bandwidth. This results in a broader envelope of the interferometric fringe pattern allowing more fringes to be detected, and thereby improving the spectral SNR. Here we present the analysis and optical design of the dispersive backend, discussing the tradeoffs and how it can be combined with the existing design.

Dhabal, Arnab↗

Alternative solenoid compensation scheme for the FCC-ee interaction region

We present the optics design of the solenoid compensation scheme at the FCC-ee. The 2T solenoids from the experiments induce coupling on the beams, generating an increase on vertical emittance. This compensation scheme minimizes emittance growth, with a final value of approximately 5% of the nominal. A screening solenoid is placed around the Final Focus Quadrupoles to protect them from the experiment’s field. A skew quadrupole component is added to the Final Doublet, aligning the magnet axis to the rotated reference frame of the beam. Two anti-solenoids placed approximately ±20 m from the IP are used to cancel the field integral. The vertical orbit generated by the horizontal crossing angle in the detector field is compensated by vertical correctors placed right after the beam pipe separation and next to the final focus quadrupoles. We describe the IR optics in this scheme, including the detector solenoid and the magnetic elements used for compensation.

43 PARTICLE ACCELERATORS↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗

Design and implementation of a 120 GHz tracking interferometer with near diffraction limited focal spot

The design and implementation of a 120 GHz monostatic tracking interferometer with near diffraction limited focal spot size, used to measure line-averaged plasma density in the source of a plasma opening switch (POS), is described. Physical dimensions of the switch source place an upper limit on the focal spot size. Focusing quasioptics utilize a standard pyramidal horn and a pair of cylindrical lenses that are easily fabricated. The combination of the two cylindrical lenses transforms the asymmetric and approximately Gaussian beam produced by the pyramidal horn into a small focal spot. The circuit utilizes a tracking receiver configuration to track oscillator frequency drifts, which allow for full heterodyne quadrature operation, while avoiding the added complexity of phase or frequency locking of the sources. In order to reduce system noise in the POS pulsed power environment, all sources and amplifiers are battery powered and other noise-reducing techniques are employed. Finally, an improved Gaussian optics design methodology, which tracks the phase center of the Gaussian beam, is proposed. While not critical to this application, this method may yield improvements in systems with short focal lengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and simulation of the nuSTORM facility

This thesis provides a full design and simulation of the nuSTORM beam line facility including the pion beam line , the pion and muon orbit combination section, and the muon decay ring. The study also includes the development of numerical optimization methods and their application to the design. At nuSTORM, one proton batch from the Main Injector (MI) is extracted and transported to the target station to bombard a solid target. A magnetic horn is used as the collection device for the secondary particles such as pions and kaons. A pion beam line is designed to transport the secondary particles downstream to the muon decay ring. In order to avoid the use of a fast kicker with a large aperture for the injection, an Orbit Combination Section (OCS) was designed to combine the reference pion orbit with the circulating muon orbit. This ful lls the stochastic injection scheme proposed in the 1980s. It is shown through the simulation that the pion beam line is able to deliver 0.011 muons per proton on target within the acceptance of the ring. In order to improve the circulating muon ux, an optimization of the magnetic collection horn was studied. A Multi-Objective Genetic Algorithm (MOGA), that was modi ed to integrate Message Passing Interface (MPI) in the process, is applied to the optimization. The number of muons within the ring acceptance from the pion decay is estimated by the pions after the collection horn. This new method was proposed to lower the requirement on the computing resources for the optimization. The study gives a new and better target and horn con guration after a full investigation of the system. The nuSTORM ring is examined with two optics designs. With di erent features, the two designs are optimized via correcting the nonlinearities with sextupolar eld distribution in the ring. A modi ed MPI-based Simulated Annealing (SA) algorithm was applied to obtain the optimal ring acceptance. The comparison with the GA shows good agreements on the achieved optimal ring acceptance. The pion and muon beams at nuSTORM were simulated and yield avor-pure and precisely measurable neutrino beams, which can be used to provide a de nite statement about the existence of a sterile neutrino.

97 MATHEMATICS AND COMPUTING↗

Fracture dynamics in implanted silicon

Crack propagation in implanted silicon for thin layer transfer is experimentally studied. The crack propagation velocity as a function of split temperature is measured using a designed optical setup. Interferometric measurement of the gap opening is performed dynamically and shows an oscillatory crack “wake” with a typical wavelength in the centimetre range. The dynamics of this motion is modelled using beam elasticity and thermodynamics. The modelling demonstrates the key role of external atmospheric pressure during crack propagation. A quantification of the amount of gas trapped inside pre-existing microcracks and released during the fracture is made possible, with results consistent with previous studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controlled structures technology and the design of an optical interferometer spacecraft

The impact of extremely stringent structural control requirements and controlled structures techniques on the overall design of a spacecraft system is examined. A space-based optical interferometer presents a design case that necessitates the application of controlled structures technology. In order for interferometry to succeed, differential pathlengths between the optical components need to be identical within a fraction of a wavelength of the light (about 25 nm for visible light). This high level of precision must be maintained on a large, flexible structure in the face of common spacecraft vibrational disturbances. Aspects of spacecraft design are examined to determine the impact of structural control on the 'normal' design process. Structural control objectives can drive several choices in subsystem component selection and sizing that minimize the vibrational environment.

Nisbet, Andrew M.↗