Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Squeezing in phase-conjugated resonance fluorescence

Emission of resonance fluorescence by an atom near the surface of a four-wave mixing phase conjugator is considered. The dipole radiation field, regarded as a Heisenberg-operator field, is decomposed into plane waves with the aid of Weyl's representation of the Green's function for the wave equation. Each plane-wave component which is incident on the surface of the nonlinear medium, is reflected as its phase-conjugate image. Summation of all reflected plane waves then yields the phase conjugate replica of the incident dipole radiation. This field adds to the radiation which is emitted by the atom into the direction away from the medium. The condition under which squeezing occurs in the emitted resonance fluorescence is investigated.

Arnoldus, Henk F.↗

Parameter dimension of turbulence-induced phase errors and its effects on estimation in phase diversity

The method of phase diversity has been used in the context of incoherent imaging to estimate jointly an object that is being imaged and phase aberrations induced by atmospheric turbulence. The method requires a parametric model for the phase-aberration function. Typically, the parameters are coefficients to a finite set of basis functions. Care must be taken in selecting a parameterization that properly balances accuracy in the representation of the phase-aberration function with stability in the estimates. It is well known that over parameterization can result in unstable estimates. Thus a certain amount of model mismatch is often desirable. We derive expressions that quantify the bias and variance in object and aberration estimates as a function of parameter dimension.

Thelen, Brian J.↗

JUPITER’S PHASE VARIATIONS FROM CASSINI : A TESTBED FOR FUTURE DIRECT-IMAGING MISSIONS

We present empirical phase curves of Jupiter from ∼0° to 140° as measured in multiple optical bandpasses by Cassini /Imaging Science Subsystem (ISS) during the Millennium flyby of Jupiter in late 2000 to early 2001. Phase curves are of interest for studying the energy balance of Jupiter and understanding the scattering behavior of the planet as an exoplanet analog. We find that Jupiter is significantly darker at partial phases than an idealized Lambertian planet by roughly 25% and is not well fit by Jupiter-like exoplanet atmospheric models across all wavelengths. We provide analytic fits to Jupiter’s phase function in several Cassini /ISS imaging filter bandpasses. In addition, these observations show that Jupiter’s color is more variable with phase angle than predicted by models. Therefore, the color of even a near Jupiter-twin planet observed at a partial phase cannot be assumed to be comparable to that of Jupiter at full phase. We discuss how the Wide-Field Infrared Survey Telescope and other future direct-imaging missions can enhance the study of cool giants.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid quantitative simulation on the in-line phase-contrast x-ray imaging of three dimensional samples under actual clinic imaging parameters

A hybrid model combining Monte Carlo method with diffraction theory of wave optics has been developed and applied to quantitatively simulate the in-line diffractive phase-contrast x-ray imaging of three dimensional tissue samples under actual clinic imaging parameters. The primary microcosmic interactions of medical-energy x-ray within matter including photoabsorption, Compton scattering, and coherent scattering, have been taken into account in the Monte Carlo simulation. A diffraction processing based on Fresnel diffraction theory is carried out to simulate the macroscopic diffraction effect. A comparison with experiment results has also been performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray Phase Contrast analysis - Digital wavefront development

Optical schemes that enable imaging of the phase shift produced by an object have become popular in the x-ray region, where phase can be the dominant contrast mechanism. The propagation-based technique consists of recording the interference pattern produced by choosing one or several sample-to-detector distances. Pioneering studies, carried out making use of synchrotron radiation, demonstrated that this technique results in a dramatic increase of image contrast and detail visibility, allowing the detection of structures invisible with conventional techniques. An experimental and theoretical study of in-line hard x-ray phase-contrast imaging had been performed. The theoretical description of the technique is based on Fresnel diffraction. As an illustration of the potential of this quantitative imaging technique, high-resolution x-ray phase contrast images of simple objects will be presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Talbot-Lau X-Ray Deflectometry for Dynamic Density Profile Measurements

X-ray phase contrast imaging with transmission gratings for density profile measurements is being developed for dynamic experimental applications. Talbot-Lau deflectometry is a new method of measuring x-ray refraction in addition to attenuation and ultra-small angle scattering that has recently been developed for static imaging, primarily for medical and industrial applications. A flash x-ray source, with a spot size much larger than the continuous microfocus sources of static imaging systems, must be used to obtain density profiles from fast-evolving systems, and only a single exposure can be obtained. These new challenges are addressed by introducing an asymmetric setup and developing a forward modeling technique to infer an electron density profile from a single-image, low spatial–resolution system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Illustrating the effect of viscoelastic additives on cavitation and turbulence with X-ray imaging

The effect of viscoelastic additives on the topology and dynamics of the two-phase flow arising within an axisymmetric orifice with a flow path constriction along its main axis has been investigated employing high-flux synchrotron radiation. X-ray Phase Contrast Imaging (XPCI) has been conducted to visualise the cavitating flow of different types of diesel fuel within the orifice. An additised blend containing Quaternary Ammonium Salt (QAS) additives with a concentration of 500 ppm has been comparatively examined against a pure (base) diesel compound. A high-flux, 12 keV X-ray beam has been utilised to obtain time resolved radiographs depicting the vapour extent within the orifice from two views (side and top) with reference to its main axis. Different test cases have been examined for both fuel types and for a range of flow conditions characterised by Reynolds number of 35500 and cavitation numbers (CN) lying in the range 3.0–7.7. It has been established that the behaviour of viscoelastic micelles in the regions of shear flow is not consistent depending on the cavitation regimes encountered. Namely, viscoelastic effects enhance vortical (string) cavitation, whereas hinder cloud cavitation. Furthermore, the use of additised fuel has been demonstrated to suppress the level of turbulence within the orifice.

36 MATERIALS SCIENCE↗

Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

Purpose: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).Methods: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Results: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion-blurring artifacts are present, leading to a 24.4% relative reconstruction error in the NACT phantom. View aliasing artifacts are present in 4D-CBCT reconstructed by FDK from 20 projections, with a relative error of 32.1%. When total variation minimization is used to reconstruct 4D-CBCT, the relative error is 18.9%. Image quality of 4D-CBCT is substantially improved by using the SMEIR algorithm and relative error is reduced to 7.6%. The maximum error (MaxE) of tumor motion determined from the DVF obtained by demons registration on a FDK-reconstructed 4D-CBCT is 3.0, 2.3, and 7.1 mm along left–right (L-R), anterior–posterior (A-P), and superior–inferior (S-I) directions, respectively. From the DVF obtained by demons registration on 4D-CBCT reconstructed by total variation minimization, the MaxE of tumor motion is reduced to 1.5, 0.5, and 5.5 mm along L-R, A-P, and S-I directions. From the DVF estimated by SMEIR algorithm, the MaxE of tumor motion is further reduced to 0.8, 0.4, and 1.5 mm along L-R, A-P, and S-I directions, respectively.Conclusions: The proposed SMEIR algorithm is able to estimate a motion model and reconstruct motion-compensated 4D-CBCT. The SMEIR algorithm improves image reconstruction accuracy of 4D-CBCT and tumor motion trajectory estimation accuracy as compared to conventional sequential 4D-CBCT reconstruction and motion estimation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Edge turbulence and divertor heat flux width simulations of Alcator C-Mod discharges using an electromagnetic two-fluid model

The BOUT++ code has been utilized in order to improve the understanding of the role of turbulent modes in controlling edge transport and resulting scaling of the scrape-off layer (SOL) heat flux width. For the C-Mod enhanced D α (EDA) H-mode discharges, BOUT++ six-field two-fluid nonlinear simulations show a reasonable agree- ment of upstream turbulence and divertor target heat flux behavior: a) The simulated quasi-coherent modes (QCMs) show consistent characteristics of the frequency versus poloidal wave number spectra of the electromagnetic fluctuations when compared with experimental measurements: frequencies are around 60-120 kHz (experiment: about 70-110 kHz), k θ are around 2.0 cm ₋1 which is similar to the Phase Contrast Imaging data; b) Linear spectrum analysis is consistent with the nonlinear phase relationship cal- culation which indicates the dominance of resistive-ballooning modes and drift-Alfven wave instabilities; c) The SOL heat flux width λ q vs current I p scaling is reproduced by turbulent transport: the simulations yield similar λ q to experimental measurements within a factor of 2. Yet the magnitudes of divertor heat fluxes can be varied, depending on the physics models, sources and sinks, sheath boundary conditions, or flux limiting coefficient; d) Simple estimate by the "2-point model" for λ q is consistent with simulation. Moreover, blobby turbulent spreading is confirmed for these relatively high B p shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-123: Assessing Segmentation Accuracy of Internal Volumes and Sub-Volumes in 4D PET/CT of Lung Tumors Using a Novel 3D Printed Phantom

Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images were binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.

60 APPLIED LIFE SCIENCES↗

Seismic Holography of Solar Activity

The basic goal of the project was to extend holographic seismic imaging techniques developed under a previous NASA contract, and to incorporate phase diagnostics. Phase-sensitive imaging gives us a powerful probe of local thermal and Doppler perturbations in active region subphotospheres, allowing us to map thermal structure and flows associated with "acoustic moats" and "acoustic glories". These remarkable features were discovered during our work, by applying simple acoustic power holography to active regions. Included in the original project statement was an effort to obtain the first seismic images of active regions on the Sun's far surface.

Lindsey, Charles↗

Single-Grating Talbot Imaging for Wavefront Sensing and X-Ray Metrology

Single-grating Talbot imaging relies on high-spatial-resolution detectors to perform accurate measurements of X-ray beam wavefronts. The wavefront can be retrieved with a single image, and a typical measurement and data analysis can be performed in few seconds. These qualities make it an ideal tool for synchrotron beamline diagnostics and in-situ metrology. The wavefront measurement can be used both to obtain a phase contrast image of an object and to characterize an X-ray beam. In this work, we explore the concept in two cases: at-wavelength metrology of 2D parabolic beryllium lenses and a wavefront sensor using a diamond crystal beam splitter.

Grating Interferometry↗

Direct Imaging of Antiferromagnet-Ferromagnet Phase Transition in van der Waals Antiferromagnet CrSBr

The advent of van der Waals (vdW) ferromagnetic (FM) and antiferromagnetic (AFM) materials offers unprecedented opportunities for spintronics and magneto-optic devices. Combining magnetic Kerr microscopy and density functional theory calculations, the AFM-FM transition is investigated and a surprising abnormal magneto-optic anisotropy in vdW CrSBr associated with different magnetic phases (FM, AFM, or paramagnetic state) is discovered. This unique magneto-optic property leads to different anisotropic optical reflectivity from different magnetic states, permitting direct imaging of the AFM Néel vector orientation and the dynamic process of the AFM-FM transition within a magnetic field. Using Kerr microscopy, not only the domain nucleation and propagation process is imaged but also the intermediate spin-flop state in the AFM-FM transition is identified. In conclusion, the unique magneto-optic property and clear identification of the dynamics process of the AFM-FM phase transition in CrSBr demonstrate the promise of vdW magnetic materials for future spintronic technology.

36 MATERIALS SCIENCE↗

An Overview of the Mid-Infrared Spectro-Interferometer MATISSE: Science, Concept, and Current Status

MATISSE is the second-generation mid-infrared spectrograph and imager for the Very Large Telescope Interferometer (VLTI) at Paranal. This new interferometric instrument will allow significant advances by opening new avenues in various fundamental research fields: studying the planet-forming region of disks around young stellar objects, understanding the surface structures and mass loss phenomena affecting evolved stars, and probing the environments of black holes in active galactic nuclei. As a first breakthrough, MATISSE will enlarge the spectral domain of current optical interferometers by offering the L and M bands in addition to the N band. This will open a wide wavelength domain, ranging from 2.8 to 13 microns, exploring angular scales as small as 3 mas (L band) 10 mas (N band). As a second breakthrough, MATISSE will allow mid-infrared imaging - closure-phase aperture-synthesis imaging - with up to four Unit Telescopes (UT) or Auxiliary Telescopes (AT) of the VLTI. Moreover, MATISSE will offer a spectral resolution range from R approx. 30 to R approx. 5000. Here, we present one of the main science objectives, the study of protoplanetary disks, that has driven the instrument design and motivated several VLTI upgrades (GRA4MAT and NAOMI). We introduce the physical concept of MATISSE including a description of the signal on the detectors and an evaluation of the expected performances. We also discuss the current status of the MATISSE instrument, which is entering its testing phase, and the foreseen schedule for the next two years that will lead to the first light at Paranal.

interferometric instrument↗

Magnetic imaging and statistical analysis of the metamagnetic phase transition of FeRh with electron spins in diamond

Magnetic imaging based on nitrogen-vacancy (NV) centers in diamond has emerged as a powerful tool for probing magnetic phenomena in fields ranging from biology to physics. A key strength of NV sensing is its local-probe nature, enabling high-resolution spatial images of magnetic stray fields emanating from a sample. However, this local character can also form a drawback for analyzing the global properties of a system, such as a phase transition temperature. Here, we address this challenge by using statistical analyses of magnetic-field maps to characterize the first-order temperature-driven metamagnetic phase transition from the antiferromagnetic to the ferromagnetic state in FeRh. After imaging the phase transition and identifying the regimes of nucleation, growth, and coalescence of ferromagnetic domains, we statistically characterize the spatial magnetic-field maps to extract the transition temperature and thermal hysteresis width. By analyzing the spatial correlations of the maps in relation to the magnetocrystalline anisotropy and external magnetic field, we detect a reorientation of domain walls across the phase transition. The employed statistical approach can be extended to the study of other magnetic phenomena with NV magnetometry or other sensing techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of CCD imaging sensors for space applications, phase 1

The results of an experimental investigation to develop a large area charge coupled device (CCD) imager for space photography applications are described. Details of the design and processing required to achieve 400 X 400 imagers are presented together with a discussion of the optical characterization techniques developed for this program. A discussion of several aspects of large CCD performance is given with detailed test reports. The areas covered include dark current, uniformity of optical response, square wave amplitude response, spectral responsivity and dynamic range.

Antcliffe, G. A.↗

SU-E-J-120: Comparing 4D CT Computed Ventilation to Lung Function Measured with Hyperpolarized Xenon-129 MRI

Purpose: To correlate ventilation parameters computed from 4D CT to ventilation, profusion, and gas exchange measured with hyperpolarized Xenon-129 MRI for a set of lung cancer patients. Methods: Hyperpolarized Xe-129 MRI lung scans were acquired for lung cancer patients, before and after radiation therapy, measuring ventilation, perfusion, and gas exchange. In the standard clinical workflow, these patients also received 4D CT scans before treatment. Ventilation was computed from 4D CT using deformable image registration (DIR). All phases of the 4D CT scan were registered using a B-spline deformable registration. Ventilation at the voxel level was then computed for each phase based on a Jacobian volume expansion metric, yielding phase sorted ventilation images. Ventilation based upon 4D CT and Xe-129 MRI were co-registered, allowing qualitative visual comparison and qualitative comparison via the Pearson correlation coefficient. Results: Analysis shows a weak correlation between hyperpolarized Xe-129 MRI and 4D CT DIR ventilation, with a Pearson correlation coefficient of 0.17 to 0.22. Further work will refine the DIR parameters to optimize the correlation. The weak correlation could be due to the limitations of 4D CT, registration algorithms, or the Xe-129 MRI imaging. Continued development will refine parameters to optimize correlation. Conclusion: Current analysis yields a minimal correlation between 4D CT DIR and Xe-129 MRI ventilation. Funding provided by the 2014 George Amorino Pilot Grant in Radiation Oncology at the University of Virginia.

60 APPLIED LIFE SCIENCES↗

The Precision Formation Flying Integrated Analysis Tool (PFFIAT)

Several space missions presently in the concept phase (e.g. Stellar Imager, Sub- millimeter Probe of Evolutionary Cosmic Structure, Terrestrial Planet Finder) plan to use multiple spacecraft flying in precise formation to synthesize unprecedently large aperture optical systems. These architectures present challenges to the attitude and position determination and control system; optical performance is directly coupled to spacecraft pointing with typical control requirements being on the scale of milliarcseconds and nanometers. To investigate control strategies, rejection of environmental disturbances, and sensor and actuator requirements, a capability is needed to model both the dynamical and optical behavior of such a distributed telescope system. This paper describes work ongoing at NASA Goddard Space Flight Center toward the integration of a set of optical analysis tools (Optical System Characterization and Analysis Research software, or OSCAR) with the Formation J?lying Test Bed (FFTB). The resulting system is called the Precision Formation Flying Integrated Analysis Tool (PFFIAT), and it provides the capability to simulate closed-loop control of optical systems composed of elements mounted on multiple spacecraft. The attitude and translation spacecraft dynamics are simulated in the FFTB, including effects of the space environment (e.g. solar radiation pressure, differential orbital motion). The resulting optical configuration is then processed by OSCAR to determine an optical image. From this image, wavefront sensing (e.g. phase retrieval) techniques are being developed to derive attitude and position errors. These error signals will be fed back to the spacecraft control systems, completing the control loop. A simple case study is presented to demonstrate the present capabilities of the tool.

Stoneking, Eric↗