Search NASA⌕ Search

SEARCH · Search NASA

Results for “Patient Support System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

694 records · Page 39

WE-FG-207A-03: Low-Dose Cone-Beam Breast CT: Physics and Technology Development

Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

WE-FG-207A-04: Performance Characteristics of Photon-Counting Breast CT

Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

WE-FG-207A-05: Dedicated Breast CT as a Diagnostic Imaging Tool: Physics and Clinical Feasibility

Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

Efficacy of compression of different capacitance beds in the amelioration of orthostatic hypotension

Orthostatic hypotension (OH) is the most disabling and serious manifestation of adrenergic failure, occurring in the autonomic neuropathies, pure autonomic failure (PAF) and multiple system atrophy (MSA). No specific treatment is currently available for most etiologies of OH. A reduction in venous capacity, secondary to some physical counter maneuvers (e.g., squatting or leg crossing), or the use of compressive garments, can ameliorate OH. However, there is little information on the differential efficacy, or the mechanisms of improvement, engendered by compression of specific capacitance beds. We therefore evaluated the efficacy of compression of specific compartments (calves, thighs, low abdomen, calves and thighs, and all compartments combined), using a modified antigravity suit, on the end-points of orthostatic blood pressure, and symptoms of orthostatic intolerance. Fourteen patients (PAF, n = 9; MSA, n = 3; diabetic autonomic neuropathy, n = 2; five males and nine females) with clinical OH were studied. The mean age was 62 years (range 31-78). The mean +/- SEM orthostatic systolic blood pressure when all compartments were compressed was 115.9 +/- 7.4 mmHg, significantly improved (p < 0.001) over the head-up tilt value without compression of 89.6 +/- 7.0 mmHg. The abdomen was the only single compartment whose compression significantly reduced OH (p < 0.005). There was a significant increase of peripheral resistance index (PRI) with compression of abdomen (p < 0.001) or all compartments (p < 0.001); end-diastolic index and cardiac index did not change. We conclude that denervation increases vascular capacity, and that venous compression improves OH by reducing this capacity and increasing PRI. Compression of all compartments is the most efficacious, followed by abdominal compression, whereas leg compression alone was less effective, presumably reflecting the large capacity of the abdomen relative to the legs.

Non-NASA Center↗

Changes in autonomic activity preceding onset of nonsustained ventricular tachycardia

Background: The triggering role of the autonomic nervous system in the initiation of ventricular tachycardia has not been established. To investigate the relationship between changes in autonomic activity and the occurrence of nonsustained ventricular tachycardia (NSVT) we examined heart rate variability (HRV) during the 2-hour period preceding spontaneous episodes of NSVT. Twenty-four subjects were identified retrospectively as having had one episode of NSVT during 24-hour Holter ECC recording. Methods: We measured the mean interval between normal heats (meanRR), the standard deviation of the intervals between beats (SD), the percentage of counts of sequential intervals between normal beats with a change of >50 ms (%RR50), the logarithms of low- and high-frequency spectral components (lnLF, lnHF) of HRV for sequential 10-minute segments preceding NSVT. The correlation dimension (CDim) of HRV was calculated similarly for sequential 20-minute segments. We assessed the significance of the time-course change of each marker over the 120-minute period prior to NSVT onset. Results: MeanRR (P < 0.05), lnLF (P < 0.0001), lnHF (P < 0.0001), the natural logarithm of the ratio of LF to HF (ln[LF/HF]; P < 0.05), and CDim (P < 0.05) showed significant time-course changes during that period, while SD and %RR50 did not. MeanRR, lnLF, lnHF, and CDim all decreased prior to the onset of NSVT, whereas ln(LF/HF) increased. We divided the subjects into two groups: one consisting of 12 patients with coronary artery disease; and the second group of 12 patients without known coronary artery disease. Both groups showed significant changes (P < 0.05) of CDim, lnLF, and lnHF preceding the episodes of NSVT. Conclusions: Changes in the pattern of HRV prior to the onset of episodes of NSVT suggest that changes in autonomic activity may commonly play a role in the triggering of spontaneous episodes of NSVT in susceptible patients. The measured changes suggest a reduction in parasympathetic activity, perhaps in conjunction with an increase in sympathetic activity, may trigger NSVT.

Non-NASA Center↗

TU-AB-204-00: Advances in Cone-Beam CT and Emerging Applications

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

Potentials and Limitations of Guiding Liver Stereotactic Body Radiation Therapy Set-Up on Liver-Implanted Fiducial Markers

Purpose: We investigated the potentials and limitations of guiding liver stereotactic body radiation therapy (SBRT) set-up on liver-implanted fiducial markers. Methods and Materials: Twelve patients undergoing compression-supported SBRT in a stereotactic body frame received fluoroscopy at treatment preparation and before each treatment fraction. In fluoroscopic videos we localized the markers and diaphragm tip at expiration and the spine (measurements on free-breathing and abdominal compression). Day-to-day displacements, rotations (markers only), and deformations were determined. Marker guidance was compared to conventional set-up strategies in treatment set-up simulations. Results: For compression, day-to-day motion of markers with respect to their centers of mass (COM) was {sigma} = 0.9 mm (random error SD), {Sigma} = 0.4 mm (systematic error SD), and <2.1 mm (maximum). Consequently, assuming that markers were closely surrounding spherical tumors, marker COM-guided set-up would have required safety margins of {approx}2 mm. Using marker COM as the gold standard, other set-up methods (using no correction, spine registration, and diaphragm tip craniocaudal registration) resulted in set-up errors of 1.4 mm < {sigma} < 2.8 mm, 2.6 mm < {Sigma} < 5.1 mm, and 6.3 mm < max < 12.4 mm. Day-to-day intermarker motion of <16.7%, 2.2% median, and rotations between 3.5{sup o} and 7.2{sup o} were observed. For markers not surrounding the tumor, e.g., 5 cm between respective COMs, these changes could effect residual tumor set-up errors up to 8.4 mm, 1.1 mm median (deformations), and 3.1 mm to 6.3 mm (rotations). Compression did not systematically contribute to deformations and rotations, since similar results were observed for free-breathing. Conclusions: If markers can be implanted near and around the tumor, residual set-up errors by marker guidance are small compared to those of conventional set-up methods, allowing high-precision tumor radiation set-up. However, substantial errors may result if markers are not implanted precisely, requiring further research to obtain adequate safety margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-A-16A-01: International Medical Physics Symposium: Increasing Access to Medical Physics Education/Training and Research Excellence

In response to a world in which cancer is a growing global health challenge, there is now a greater need for US Medical Physicists and other Radiation Oncology professionals across institutions to work together and be more globally engaged in the fight against cancer. There are currently many opportunities for Medical Physicists to contribute to alleviating this pressing need, especially in helping enhance access to Medical Physics Education/training and Research Excellence across international boundaries, particularly for low and middle-income countries (LMIC), which suffer from a drastic shortage of accessible knowledge and quality training programs in radiotherapy. Many Medical Physicists are not aware of the range of opportunities that even with small effort could have a high impact. Faculty at the two CAMPEP-accredited Medical Physics Programs in New England: the University of Massachusetts Lowell and Harvard Medical School have developed a growing alliance to increase Access to Medical Physics Education/training and Research Excellence (AMPERE), and facilitate greater active involvement of U.S. Medical Physicists in helping the global fight against cancer and cancer disparities. In this symposium, AMPERE Alliance members and partners from Europe and Africa will present and discuss the growing global cancer challenge, the dearth of knowledge, research, and other barriers to providing life-saving radiotherapy in LMIC, mechanisms for meeting these challenges, the different opportunities for participation by Medical Physicists, including students and residents, and how participation can be facilitated to increase AMPERE for global health. Learning Objectives: To learn about the growing global cancer challenge, areas of greatest need and limitations to accessing knowledge and quality radiotherapy training programs, especially in LMIC; To learn about the range of opportunities for Medical Physicists, including students and residents, to work together in global health to help increase AMPERE and alleviate the growing global burden of cancer; To present and discuss a new model for harmonizing Medical Physics Training across countries and how this model (UMass and Heidelberg) could be extended to LMIC in collaboration with the IAEA; To highlight a new platform and program for facilitating contributions by Medical Physicists to increase AMPERE towards the elimination of global cancer disparities. Challenges in Cancer Control in Africa Twalib A. Ngoma, MD, Professor, Executive Director, Ocean Road Cancer Institute, Dar Es Salaam, Tanzania Cancer care in Africa is beset by lack of attention, political will, cancer registries, cancer plans, human resources, financial resources and treatment facilities.. As a result of this, cancer patients in Africa are far more likely to die of their disease than those in developed countries. According to data from the WHO 750,000 new cancer cases occur in Africa every year and this number is predicted to rise by 70% by 2020. To make matters worse, an estimated 75% of cancer patients in Africa have advanced or incurable cancers at diagnosis making palliative care the most realistic approach to their management. Furthermore, Cancer prevention is nearly nonexistent, cancer detection is rare and treatment usually comes too late and is inefficient. The overall mortality-to-incidence ratio for men with cancer in the Africa is 0.75 compared with 0.54 in the developed world while the ratios for women in Africa, is 0.65 compared with 0.45 for women in the developed world. There is also limited access to radiotherapy. According to the International Atomic Energy Agency (IAEA), whilst developed countries usually have one radiotherapy machine per 250,000 people, most African nations have only one machine per ten million people. The above numbers are alarming and speak for themselves. The only solution to improve this alarming situation is to address the major challenges which African countries face in provision of cancer services which include but not limited to lack of cancer registries, lack of funding, lack of human resources, lack of radiotherapy machines, lack of cancer drugs and lack of accessible and affordable cancer screening, early diagnosis, treatment or palliative care services. Since there are considerable differences among African countries, in my presentation I will share with the audience how we address cancer control challenges in Tanzania in general and specifically in radiation oncology. The African continent cancer plan 2013 2017 Folakemi Odedina, PhD, Professor and Director of Health Disparities, UF Health Cancer Center, University of Florida The burden of cancer is rising in Africa, in addition to current heavy burden of communicable, and other non-cancer related non—communicable diseases. Conquering cancer in Africa will require a comprehensive collaborative approach with cancer clinicians, scientists, patients, advocates, policy makers and community leaders working hand-in-hand at the local, state, national, and continent levels with the primary mission: To reduce the number of deaths from cancer and improve the quality of life of cancer patients, survivors and caregivers. Unfortunately, less than 40% of African countries have a credible cancer control policy and program. The African Organization for Research and Training in Cancer (AORTIC) decided to create an African Cancer Plan to provide cost-effective strategies that can be employed throughout the continent to fight cancer. Based on the African proverb that “It takes a village to raise a child”, the Cancer Plan provides specific strategies that can be used by individuals, employers, organizations and policy-makers to fight cancer. In addition, we have provided overarching strategies to address cancer in Africa and targeted 5-year plan for prostate, breast, cervix, lung and liver cancers. In developing this Cancer Plan, our primary goal is to decrease cancer incidence and mortality in Africa. This goal can only be achieved by stakeholders and dedicated individuals to lead and implement the strategies outlined in this plan. If you are interested in partnering with AORTIC to reduce the burden of cancer in Africa, please send an email to info@aortic-africa.org. Synergies in research and clinical care through international collaboration Thomas Bortfeld and David Gierga, Massachusetts General Hospital, Harvard Medical School, MA Medical Physics relies on high technology that is not distributed equally. The whole spectrum of Medical Physics technologies is not available at every hospital or research institute, and not even in every high income country. One example is heavy ion therapy equipment which is currently only available in Japan, Germany and Italy. There is also a large global variation in terms of research infrastructure and focus. A student of Medical physics cannot gain broad experience, certainly not hands-on experience, by staying at one place only. While it is debatable what a good trade-off between breadth and depth in Medical Physics education is, it is generally agreed upon that some breadth is necessary. Researchers in Medical Physics have to cross borders if they need specific technologies for their projects. Therefore it is self-evident that international programs in Medical Physics education and research make sense. Yet, very few programs of this type exist. In this presentation we will report on our own experience of pursuing an international career in Medical Physics, with international student programs, and with the international exchange of researchers. We will present new or planned opportunities such as the medical beamline at CERN in Geneva. We will also report on the synergies in clinical care through international collaborations between partners in high and low income countries. One example is the partnership of the MGH/Harvard Medical School community with the oncology community and government of Botswana to form the BOTSOGO (BOTSwana Oncology Global Outreach) initiative. This collaborative effort in oncology care was spurred by existing relationships in HIV/AIDS research and care delivery developed within the Botswana-Harvard AIDS Institute Partnership (BHP). The initial efforts of the BOTSOGO initiative have been organized as follows: 1) on-site visits to share expertise in clinical cancer care for capacity building purposes (e.g. cervical brachytherapy), 2) developing a forum for multi-disciplinary case discussions and education and 3) relationship building with local stakeholders for long-term sustainability and growth. An international system for the certification of medical physicists Raymond K. Wu, Chairman, IOMP Professional Relations Committee; Chairman, AAPM Exchange Scientist Program Subcommittee An international system for the certification of medical physicists is an important issue. The International Organization for Medical Physicists (IOMP) has in collaboration with a number of member countries established the International Medical Physics Certification Board (IMPCB) to address this issue, and to provide a mechanism to mark the milestone for the professional development of clinical medical physicists. Raymond Wu, PhD, is the CEO of IMPCB and the Chairman of the IOMP Professional Relations Committee. He is the invited speaker recommended by IOMP to give a talk on this important subject. He will give the latest update of the work of IMPCB, its near term goals, and pathways to the goals. He will also discuss the importance of such an International System of certification in the training/education of next generation Medical Physicists, including those in low and middle income countries (LMIC) where such training is crucial in the fight against cancer. Learning Objectives: Understand the certification program as described in the IOMP Policy Statements. Understand the plan of the IMPCB to establish the accreditation process of national certification programs. Understand the goals of this international collaborative effort and the potential impacts to the quality of clinical medical physics practice. Medical Physics Education Across Continents: The UMass Lowell and Heidelberg University Joint Coordination Effort Erno Sajo, Director of Medical Physics, University of Massachusetts at Lowell Medical Physics education has unique flavors across institutions within the US and shows significant differences across continents. In the latter, even the definition of Medical Physics may differ. Not only is there a difference in topical coverage, but often what is considered a cohesive topic in one institution, and taught as a single course, is fragmented among several other courses in the other institution due to a different philosophy. Because of the regulatory and certification requirements, these differences impact the mobility of medical physicists across continents. As a result, physicists who wish to practice in the US or Canada but have completed their education elsewhere often find that they have to take remedial courses or even obtain a new degree in Medical Physics despite the fact that they already have one. Outreach to developing countries, therefore, is even more difficult. The University of Massachusetts Lowell and Heidelberg University recently completed a joint coordination effort, in which they identified topics that are common versus complementary in their medical physics curricula. A student exchange program was developed that permits students to take any of the common topics at the other institution while taking complementary courses as electives, which count towards their degree requirements at their home institution. Thesis research is also mutually accepted. When properly documented, in this way CAMPEP recommendations can be met across the institutions. Therefore, students participating in this program satisfy both the American Board of Radiology (ABR) requirements and the European regulatory requirements. The framework on which this collaboration rests and the cross-comparison methods developed therein may be implemented in other exchange programs and thus a similar approach can be adopted in outreach programs with developing countries. IAEA PACT Program and opportunities for support and collaboration Susan Morgan, Program Coordinator, International Atomic Energy Agency, Vienna, Austria In response to the developing world's cancer crisis, the International Atomic Energy Agency (IAEA) established the Program of Action for Cancer Therapy (PACT) in 2004 to fully realize the public health impact obtained through global partnerships in cancer control and technology transfer in radiation medicine. PACT's vision strives for global partnerships to confront the cancer crisis in developing countries, notably with our sister United Nations agency, the World Health Organization (WHO), and our Joint Programme on Cancer Control established in 2009. The IAEA, through PACT, the WHO, the International Agency for Research on Cancer (IARC) and other cancer-related organizations work together to make a coordinated global response in supporting low and middle income (LMI) IAEA Member States in the implementation of comprehensive national cancer control programmes. PACT's goals are: To build global partnerships of cancer-related organizations committed to addressing the challenge of cancer in LMI Member States in all its aspects; To mobilize resources from charitable trusts, foundations, and others in public and private sectors sources to assist LMI Member States to develop and implement their radiation medicine capacities within a national cancer control programme (NCCP); and, To ensure the effective and sustainable transfer of radiation medicine technologies or knowledge to all LMI Member States where unmet needs exist. PACT work focuses on: imPACT: Assessing Cancer Burden PMDS: Developing Global Partnerships VUCCnet: Promoting Cancer Control Training AGaRT: Making Radiotherapy Accessible Facilitating increased participation and professional development of Medical Physicists and other Radiation Oncology professionals in global health Wilfred Ngwa, Harvard Medical School, University of Massachusetts Lowell, MA The 2014 World Health Organization (WHO) Cancer report highlights an alarming increase in the global burden of cancer. It also highlights what it terms “the cancer divide”, or disparities, evinced by a substantially higher cancer burden in low and middle income countries (LMIC) in Asia, Central/South America and Africa. The WHO even predicts a potential African cancer epidemic by 2020 if significant progress is not made in global cancer control efforts. Evidence that collaborative global health approaches have led to major progress in controlling infectious diseases including in LMIC suggests that similar approaches will be useful for non-communicable diseases like cancer. In consonance with this, leaders in cancer policy from the USA and 14 economically diverse countries recently concluded that successful campaigns to control cancers with existing methods and to improve current strategies will increasingly depend onconcerted multinational collaborations (Sci Transl Med 5, p. 175, 2013). Hence there is growing urgency for increasing collaborative global cancer Care Research and Education (CaRE), as well as support for greater effectiveness of already existing initiatives involving partners from different nations, diverse economic and cultural backgrounds. The good news is that there is a growing awareness of the importance of global health and growing interest including amongst Medical Physicists and other Radiation oncology (RadOnc) professionals to participate in global health. However, many are unaware of currently existing opportunities for participation that even with small effort could have a high impact. Over 50% of cancer patients in the developed world depend on RadOnc professionals for their treatment, and hence participation of RadOnc professionals in global health efforts in the global fight against cancer is crucial. It is also important that the next generation of RadOnc professionals (students, and residents) be trained with a global perspective, to be global health leaders in cancer CaRE. This presentation will highlight a novel platform for enhancing participation and professional development of Medical Physicists and other RadOnc professionals in global health. Ways in which this platform can facilitate contributions by Medical Physicists and other RadOnc Professionals, students and residents in global health towards the elimination of global cancer disparities will be discussed. This will be followed by a panel discussion by some of the pioneers/leaders in collaborative global cancer CaRE on the growing cancer burden, challenges and opportunities for greater active involvement and professional development.

60 APPLIED LIFE SCIENCES↗

PCR Based Microbial Monitor for Analysis of Recycled Water Aboard the ISSA: Issues and Prospects

The monitoring of spacecraft life support systems for the presence of health threatening microorganisms is paramount for crew well being and successful completion of missions. Development of technology to monitor spacecraft recycled water based on detection and identification of the genetic material of contaminating microorganisms and viruses would be a substantial improvement over current NASA plans to monitor recycled water samples that call for the use of conventional microbiology techniques which are slow, insensitive, and labor intensive. The union of the molecular biology techniques of DNA probe hybridization and polymerase chain reaction (PCR) offers a powerful method for the detection, identification, and quantification of microorganisms and viruses. This technology is theoretically capable of assaying samples in as little as two hours with specificity and sensitivity unmatched by any other method. A major advance in probe-hybridization/PCR has come about in a technology called TaqMan(TM), which was invented by Perkin Elmer. Instrumentation using TaqMan concepts is evolving towards devices that could meet NASA's needs of size, low power use, and simplicity of operation. The chemistry and molecular biology needed to utilize these probe-hybridization/PCR instruments must evolve in parallel with the hardware. The following issues of chemistry and biology must be addressed in developing a monitor: Early in the development of a PCR-based microbial monitor it will be necessary to decide how many and which organisms does the system need the capacity to detect. We propose a set of 17 different tests that would detect groups of bacteria and fungus, as well as specific eukaryotic parasites and viruses; In order to use the great sensitivity of PCR it will be necessary to concentrate water samples using filtration. If a lower limit of detection of 1 microorganism per 100 ml is required then the microbes in a 100 ml sample must be concentrated into a volume that can be added to a PCR assay; There are not likely to be contaminants in ISSA recycled water that would inhibit PCR resulting in false-negative results; The TaqMan PCR product detection system is the most promising method for developing a rapid, highly automated gene-based microbial monitoring system. The method is inherently quantitative. NASA and other government agencies have invested in other technologies that, although potentially could lead to revolutionary advances, are not likely to mature in the next 5 years into working systems; PCR-based methods cannot distinguish between DNA or RNA of a viable microorganism and that of a non-viable organism. This may or may not be an important issue with reclaimed water on the ISSA. The recycling system probably damages the capacity of the genetic material of any bacteria or viruses killed during processing to serve as a template in a PCR desinged to amplify a large segment of DNA (less than 650 base pairs). If necessary, vital dye staining could be used in addition to PCR, to enumerate the viable cells in a water sample; The quality control methods have been developed to insure that PCR's are working properly, and that reactions are not contaminated with PCR carryover products which could lead to the generation of false-positive results; and The sequences of the small rRNA subunit gene for a large number of microorganisms are known, and they consititue the best database for rational development of the oligonucleotide reagents that give PCR its great specificity. From those gene sequences, sets of oligonucleotide primers for PCR and Taqman detection that could be used in a NASA microbial monitor were constructed using computer based methods. In addition to space utilization, a microbial monitior will have tremendous terrestrial applications. Analysis of patient samples for microbial pathogens, testing industrial effluent for biofouling bacteria, and detection biological warfare agents on the battlefield are but a few of the diverse potential uses for this technology. Once fully developed, gene-based microbial monitors will become the fundamental tool in every lab that tests for microbial contaminants, and serve as a powerful weapon in mankind's war with the germ world.

Cassell, Gail H.↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗