Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Wind Power Plant Short-Circuit Modeling Guide

This report presents a discussion on modeling a wind power plant for short-circuit studies at the transmission level. Due to the longer history of use and experience with synchronous machines in the electric power grid, the short-circuit behavior of power plants using these types of machines is well understood compared to a wind power plant. It is the goal of this guideline to educate utility engineers on short-circuit modeling of wind power plants in order to increase the level of understanding of wind power plant behavior. The methods presented in this paper will assist in determining the maximum short-circuit contribution from a wind power plant for system impact studies (verifying current is within interrupting ability of protection devices), relay coordination, and arc flash hazard studies.

Williams, Joseph R.↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

Time Delay of Wide Area Damping Control in Urban Power Grid: Model-Based Analysis and Data-Driven Compensation

Due to the rapid development of economies, large urban cities consume an increasing amount of energy and have a higher requirement for power quality. Voltage source converter based high voltage direct current (VSC-HVDC) is a promising device to transmit clean power from remote regions to urban power systems, while also providing wide area damping control (WADC) for frequency stabilization. However, the time-delay naturally existing in the VSC-HVDC system may degrade the performance of WADC and even result in instability. To address this issue, this paper develops a time-delay correction control strategy for VSC-HVDC damping control in urban power grids. First, a small signal model of WADC is built to analyze the negative impacts of time delay. Then, a data-driven approach is proposed to compensate for the inherent time delay in VSC-HVDC damping control. The extensive training data will be generated under various disturbances. After offline training, the long short-term memory network (LSTM) can be implemented online to predict the actual frequency deviation based on real-time measurements. Finally, the proposed method is validated through MATLAB-Simulink in a two-area four-machine system. The results indicate that the data-driven compensation has a strong generalization ability for random delay time constants and can improve the performance of WADC significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel Cell Model Validation with Power Module Test Data

The AES Modular Power Systems (AMPS) Fuel Cell team at the NASA Glenn Research Center (GRC) has created a Microsoft Excel model of a regenerative fuel cell (RFC) system for potential lunar and Martian applications. Due to some limitations of this model, including the ability to predict transient effects in the thermal and fluidic performance of the system, a system-level transient thermal/fluids model was desired. GT-SUITE is a transient multi-physics simulation tool that is popular in the automotive industry and has a built-in template for proton exchange membrane (PEM) fuel cells. However, terrestrial fuel cells used in the automotive industry vary significantly from aerospace fuel cells. A validation effort was undertaken to compare GT SUITE model results to actual data collected during the 2015 AMPS (Advanced Exploration Systems (AES) Modular Power Systems) Power Module Demonstration in which the AMPS team used a PEM fuel cell system to power a 478 kilogram rover assembly at the Dunes test site located at GRC. The purpose of the model was to evaluate the efficacy of using GT SUITE to model a non-flow through PEM fuel cell system. The validation effort examined electrochemical performance including fuel cell stack voltage and power supplied, the thermal performance of the stack namely stack temperature and heat rejection rates, and the fluidic performance of the system including pressures, reactant consumption, and water production rates.

Model Validation↗

Modelling the TSZ power spectrum

The structure formation in university is a hierarchical process. As universe evolves, tiny density fluctuations that existed in the early universe grows under gravitational instability to form massive large scale structures. The galaxy clusters are the massive viralized objects that forms by accreting smaller clumps of mass until they collapse under their self-gravity. As such galaxy clusters are the youngest objects in the universe which makes their abundance as a function of mass and redshift, very sensitive to dark energy. Galaxy clusters can be detected by measuring the richness in optical waveband, by measuring the X-ray flux, and in the microwave sky using Sunyaev-Zel'dovich (SZ) effect. The Sunyaev-Zel'dovich (SZ) effect has long been recognized as a powerful tool for detecting clusters and probing the physics of the intra-cluster medium. Ongoing and future experiments like Atacama Cosmology Telescope, the South Pole Telescope and Planck survey are currently surveying the microwave sky to develop large catalogs of galaxy clusters that are uniformly selected by the SZ flux. However one major systematic uncertainties that cluster abundance is prone to is the connection between the cluster mass and the SZ flux. As shown by several simulation studies, the scatter and bias in the SZ flux-mass relation can be a potential source of systematic error to using clusters as a cosmology probe. In this study they take a semi-analytic approach for modeling the intra-cluster medium in order to predict the tSZ power spectrum. The advantage of this approach is, being analytic, one can vary the parameters describing gas physics and cosmology simultaneously. The model can be calibrated against X-ray observations of massive, low-z clusters, and using the SZ power spectrum which is sourced by high-z lower mass galaxy groups. This approach allows us to include the uncertainty in gas physics, as dictated by the current observational uncertainties, while measuring the cosmological parameters using the SZ power spectrum data. The paper is organized as follows. In section 2, after a brief review of the halo model description of the SZ power spectrum, they discuss their model for intra-cluster medium explaining various parameters describing gas physics. In section 3, they explore a subset of parameter space using the current low-z X-ray data of galaxy clusters and mass and redshift dependence of our intra-cluster medium model. In section 4, they explore the parameter dependence of SZ power spectrum and show the agreement of the model with the current SZ power spectrum data from SPT survey.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A buoyancy–shear–drag–scalar-based turbulence model for power-law acceleration-driven Rayleigh–Taylor, reshocked Richtmyer–Meshkov, and Kelvin–Helmholtz mixing

A previously developed phenomenological turbulence model for Rayleigh–Taylor, reshocked Richtmyer–Meshkov, and Kelvin–Helmholtz instability-induced mixing based on a general buoyancy–shear–drag model [O. Schilling, “A buoyancy–shear–drag-based turbulence model for Rayleigh–Taylor, reshocked Richtmyer–Meshkov, and Kelvin–Helmholtz mixing,” Physica D 402, 132238 (2020)] is extended to include active or passive scalar mixing and power-law acceleration-driven Rayleigh–Taylor mixing. The buoyancy–shear–drag equations are coupled to a scalar variance equation that is used to define the molecular mixing parameter θ m , and when the scalar is active, modifies the Rayleigh–Taylor and Kelvin–Helmholtz mixing layer growth parameters to depend on the asymptotic value of this parameter, θ mol . Here, the scalar variance equation is closed by algebraically or differentially modeling the scalar variance dissipation rate. Nonlinear analytical solutions of the model are obtained in the total and separate bubble and spike mixing layer width formulations with the algebraic scalar variance dissipation rate for each instability, which are then used to calibrate the mechanical and scalar equation coefficients to predict specific values of physical observables and molecular mixing parameters. Surrogate mechanical and scalar turbulent fields can be constructed by multiplying a presumed self-similar spatial profile by appropriate functions of the width and its time derivative, and of the scalar obtained by solving the ordinary differential model equations. The explicit modeling and solution of turbulent transport equations are not required. The bubble and spike mixing layer width and scalar variance equations are then solved numerically for constant-acceleration Rayleigh–Taylor, impulsively reshocked Richtmyer–Meshkov, and Kelvin–Helmholtz mixing, confirming that the prescribed level of molecular mixing is correctly predicted and illustrating the spatiotemporal evolution of the scalar fields.

Buoyancy–drag↗

Dynamic Models for Wind Turbines and Wind Power Plants

The primary objective of this report was to develop universal manufacturer-independent wind turbine and wind power plant models that can be shared, used, and improved without any restrictions by project developers, manufacturers, and engineers.

17 WIND ENERGY↗

Computer-Aided Modeling and Analysis of Power Processing Systems (CAMAPPS). Phase 1: Users handbook

The EASY5 macro component models developed for the spacecraft power system simulation are described. A brief explanation about how to use the macro components with the EASY5 Standard Components to build a specific system is given through an example. The macro components are ordered according to the following functional group: converter power stage models, compensator models, current-feedback models, constant frequency control models, load models, solar array models, and shunt regulator models. Major equations, a circuit model, and a program listing are provided for each macro component.

Kim, S.↗

Singularity problems of the power law for modeling creep compliance

An explanation is offered for the extreme sensitivity that has been observed in the power law parameters of the T300/934 graphite epoxy material systems during experiments to evaluate the system's viscoelastic response. It is shown that the singularity associated with the power law can explain the sensitivity as well as the observed variability in the calculated parameters. Techniques for minimizing errors are suggested.

Dillard, D. A.↗

Reduced-Order Models of Static Power Grids based on Spectral Clustering

For large-scale interconnected power systems that cover large geographical areas, certain electrical studies are required so that appropriate decisions ensure system reliability and low cost. For such studies, it is often neither practical nor necessary to model in detail the entire power system, which is increasingly complex due to a more diverse range of grid assets to choose from in both short and long-term planning. The goal of this paper is to present a methodology to reduce the order of large-scale power networks based on spectral graph theory given that current methods for static network reduction are not scalable. A brief analysis of some spectral clustering properties to determine which graph Laplacian matrix should be used and why is included. The analysis shows that the utilization of the normalized graph Laplacian is more advantageous for clustering purposes. Techniques are proposed to approximate cost functions for the aggregated generators. This is done via linear regression. The reduced-order model obtained with the proposed methodology has an accuracy above 94% and solves the scalability issue commonly present in other reduction methods. If the utilization of the reduced-order model is either constrained to load levels above mid-peak demand, or cost functions of aggregated units are approximated via a piecewise quadratic approach, then the error distribution is in the order of 10^-3. .

Baquedano-Aguilar, Mario D.↗

Transitioning of power flow in beam models with bends

The propagation of power flow through a dynamically loaded beam model with 90 degree bends is investigated using NASTRAN and McPOW. The transitioning of power flow types (axial, torsional, and flexural) is observed throughout the structure. To get accurate calculations of the torsional response of beams using NASTRAN, torsional inertia effects had to be added to the mass matrix calculation section of the program. Also, mass effects were included in the calculation of BAR forces to improve the continuity of power flow between elements. The importance of including all types of power flow in an analysis, rather than only flexural power, is indicated by the example. Trying to interpret power flow results that only consider flexural components in even a moderately complex problem will result in incorrect conclusions concerning the total power flow field.

Hambric, Stephen A.↗

Dynamics and control of a continuum model for a solar power system

An approach for modeling dynamic equations of motion of a plate attached with rigid bodies is presented. The equations of motion are developed using the principle of virtual work. Lagrange multipliers are used as interaction forces and/or moments to maintain prescribed constraints which is the basis of the interconnection between the plate and rigid bodies. The overall approach is unique in the sense that a continuous model described by a family of partial differential equations is established. An approximate formulation by using variational method is established yielding a solution compatible with the assumed degree of approximation. The formulation is useful particularly when parametric study of dynamic response for a satellite power system is desired. As an example, an approximate governing equation of algebraic eigenvalue problem is given for a dual microwave power transmission system. Controller design is discussed.

Juang, J. N.↗

Modelling Concentrating Solar Power with Thermal Energy Storage for Integration Studies (Presentation)

Concentrating solar power with thermal energy storage (CSP-TES) can provide multiple benefits to the grid, including low marginal cost energy and the ability to levelize load, provide operating reserves, and provide firm capacity. It is challenging to properly value the integration of CSP because of the complicated nature of this technology. Unlike completely dispatchable fossil sources, CSP is a limited energy resource, depending on the hourly and daily supply of solar energy. To optimize the use of this limited energy, CSP-TES must be implemented in a production cost model with multiple decision variables for the operation of the CSP-TES plant. We develop and implement a CSP-TES plant in a production cost model that accurately characterizes the three main components of the plant: solar field, storage tank, and power block. We show the effect of various modelling simplifications on the value of CSP, including: scheduled versus optimized dispatch from the storage tank and energy-only operation versus co-optimization with ancillary services.

14 SOLAR ENERGY↗

Operating Wind Turbine as Synchronous Generator: Modeling and Power-Hardware-in-the-Loop Demonstration

Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.

17 - WIND ENERGY↗

Estimating the Performance and Economic Value of Multiple Concentrating Solar Power Technologies in a Production Cost Model

Concentrating solar power with thermal energy storage (CSP-TES) is a unique source of renewable energy in that the solar thermal energy can be dispatched similarly to conventional thermal generation. However, CSP-TES plants are energy-limited, meaning that their response might be restricted by solar availability. Therefore, the use of this limited solar energy must be optimally scheduled toprovide the greatest value to the system. The timing of CSP-TES dispatch depends on a variety of factors, including electricity demand patterns, the penetration of variable generation sources, and the configuration of the CSP-TES plant itself. We use an established CSP-TES modeling framework in a commercially available production cost model to compare the dispatch and value of two CSP-TEStechnologies (molten salt towers and parabolic troughs) in a Colorado test system. In addition, we consider a range of configuration parameters, such as the solar multiple and thermal energy storage limit, to evaluate how the operational and capacity value varies with plant configuration.

14 SOLAR ENERGY↗

A hot gaseous galaxy halo candidate with Mg X absorption

The hot gas in galaxy halos may account for a significant fraction of missing baryons in galaxies, and some of these gases can be traced by high ionization absorption systems in QSO UV spectra. Using high S/N Hubble Space Telescope/Cosmic Origins Spectrograph spectra, we discovered a high ionization state system at z = 1.1912 in the sightline toward LBQS 1435-0134, and two-component absorption lines are matched for Mg x, Ne viii, Ne vi, O vi, Ne v, O v, Ne iv, O iv, N iv, O iii, and H i. Mg x, detected for the first time (5.8σ), is a particularly direct tracer of hot galactic halos, as its peak ion fraction occurs near 10{sup 6.1} K, about the temperature of a virialized hot galaxy halo of mass ∼0.5M{sup ∗}. With Mg x and Ne viii, a photoionization model cannot reproduce the observed column densities with path lengths of galaxy halos. For collisional ionization models, one or two-temperature models do not produce acceptable fits, but a three-temperature model or a power-law model can produce the observed results. In the power-law model, dN/dT=10{sup 4.4±2.2−[Z/X]}T{sup 1.55±0.41} with temperatures in the range of 10{sup 4.39±0.13} K<T<10{sup 6.04±0.05} K, the total hydrogen column density is 8.2×10{sup 19}(0.3 Z{sub ⊙}/Z) cm{sup −2} and the positive power-law index indicates most of the mass is at the high temperature end. We suggest that this absorption system is a hot volume-filled galaxy halo rather than interaction layers between the hot halo and cool clouds. The temperature dependence of the column density is likely due to the local mixture of multiple phase gases.

79 ASTRONOMY AND ASTROPHYSICS↗