Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Monitoring Hexavalent Chromium in the Columbia River Hypo-rheic Zone - 16405

Concentrations of hexavalent chromium in groundwater at the 100-BC reactor area, located on the U.S. Department of Energy's Hanford Site, exceed the State of Washington's surface water quality criterion of 10 μg/L. Groundwater discharge to the Columbia River is the primary pathway for contaminants to reach potential receptors. Additional monitoring was needed in order to make an informed decision about groundwater remediation. An array of 23 hypo-rheic sampling points (HSPs) was installed and monitored. The HSPs consist of stainless-steel tubing with 15-cm long mesh screens at depths ranging from 0.15 to 1 meter in the riverbed. The HSPs, which are fully submerged at all river stages, were installed and sampled from a boat using low-flow pumping. The HSPs provided permanent sampling points to obtain samples of hypo-rheic zone water. They were equally suitable for high-frequency sampling, with up to 48 samples collected from each HSP over a 4-day period, and long-term monitoring, with monthly grab samples collected over a 2-year period. The HSPs could be sampled at any river stage, which varied up to 3 meters daily and 4 meters seasonally. Pumping rates were kept low to ensure representative sampling and avoid hydraulic short-circuiting. Short-term increases in river stage did not suppress hexavalent chromium concentrations. Monthly sampling showed that hexavalent chromium concentrations and specific conductance did decline during periods of sustained, seasonally high river stage. Concentrations varied from <2 μg/L during high river stage to 25 μg/L during moderate to low river stage, compared to 50 to 60 μg/L in near-river monitoring wells. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of a simple asynchronous mechanical light chopper to multielectron coincidence spectroscopy

A simple asynchronous mechanical light chopper, based on modification of a turbo-molecular pump, has been developed to extend the interval between light pulses in single bunch operation at the Photon Factory storage ring. A pulse repetition rate of 80 kHz was achieved using a cylinder rotating at 48000 rpm, with 100 slits of 80 {mu}m width. This allows absolute timing of particles up to 12.48 {mu}s instead of the single-bunch period of 624 ns. We have applied the chopper together with a light pulse monitor to measure multielectron coincidence spectra using a magnetic bottle time-of-flight electron spectrometer. With such a system, the electron energies are determined without any ambiguity, the folding of coincidence spectra disappears and the effect of false coincidences is drastically reduced.

43 PARTICLE ACCELERATORS↗

A self-checking fiber optic dosimeter for monitoring common errors in brachytherapy applications

Scintillation dosimetry with optical fiber readout [fiber optic dosimetry (FOD)] requires accurate measurement of light intensity. It is therefore vulnerable to loss of calibration if any changes occur in the efficiency of the optical pathway between the scintillator and the light detector. The authors show in this article that common types of errors that arise during clinical use for brachytherapy applications can be quantified using a light emitting diode to stimulate the scintillator, the so-called LED-FOD method, in an integrated and easy-to-use control unit that incorporates a compact peripheral component interconnect extension for instrumentation. Common sources of error include bending and mechanical compression of the fiber optic components and changes in the temperature of the scintillator. The authors show that the method can detect all the common errors studied in this work and that different types of errors can result in different correlations between the LED stimulated signal and the brachytherapy source signal. For a single-type error the LED-FOD can be used easily for system diagnosis and validation with the possibility to correct the dosimeter reading if the correlation between the LED stimulated signal and the brachytherapy source signal can be defined. For more complex errors, resulting from two or more errors occurring simultaneously, the LED-FOD method can also allow the clinician to make a judgment on the reliability of the dosimeter reading. This self-checking method can enhance the clinical robustness of the FOD for achieving accurate dose control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction for turbidity and pH interference for in situ hexavalent chromium monitoring - 16297

Hexavalent chromium is of increasing concern worldwide because of its toxicity, mobility in aqueous media, and relative abundance in waste effluent from a variety of industrial processes. Some of that waste has reached groundwater aquifers. Because of these factors, the fate and transport of hexavalent chromium in aquifers is of great importance for evaluating risk to fresh water sources and to the biosphere, and for designing means for abatement or remediation. Conventional sampling and analysis of groundwater samples from wells is labor intensive and therefore budget limited. The result is inadequate temporal and spatial characterization of contaminant plumes with respect to rate of movement, concentrations, and contaminant flux. A submersible hexavalent chromium sensor designed for extended-term deployment and based on ultraviolet colorimetry has been developed and tested at the Hanford Site, Washington. Adaptation of the method for in situ measurements requires automatic correction for sample turbidity and pH for every measurement. Turbidity is compensated nephelometrically. A method for estimating sample pH based on absorbance measurements made using two different wavelengths is presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dosimetric Comparison of RapidArc with Fixed Gantry Intensity-Modulated Radiotherapy Treatment for Multiple Liver Metastases Radiotherapy

We wanted to compare the dosimetric difference and treatment efficiency of RapidArc and fixed gantry intensity-modulated radiotherapy treatment (IMRT) for multiple liver metastases. Computed tomography datasets of 10 patients were studied retrospectively. IMRT plans were generated using 5 fields and RapidArc using either 1 or 2 arcs. The dose distribution of planning target volume (PTV), organs at risk (OARs), and the normal tissue were compared. Monitor units and treatment time were scored to measure expected treatment efficiency. Both RapidArc and IMRT plans resulted in equivalent target coverage. There was no statistically significant difference for the maximum and the minimum dose of PTV. RapidArc plans achieved an improved conformity index compared with IMRT (RA1 = 1.68 {+-} 0.27, RA2 = 1.61 {+-} 0.25, IMRT = 1.80 {+-} 0.37). For OARs, all techniques respected planning objectives. RapidArc plans had a lower dose in V{sub 40} of small bowel than IMRT, but were higher in mean dose of kidneys. Concerning the V{sub 5}, V{sub 10}, and V{sub 15} of healthy tissue, RapidArc plans were higher than IMRT. However, the V{sub 20}, V{sub 25}, and V{sub 30} of healthy tissue in RapidArc plans were lower than IMRT. Monitor units per fraction of RapidArc plans were about 40% or 46% of IMRT. Compared with IMRT plans, treatment time of RapidArc plans were reduced by 60% or 70%. All techniques respected planning objectives. RapidArc showed statistical improvements in conformity index and healthy tissue sparing with uncompromised target coverage. This, in combination with fewer monitor units and short delivery time, can lead to clinically significant advances for the treatment of multiple liver metastases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Norm - contaminated iodine production facilities decommissioning in Turkmenistan: experience and results

This report summarizes the data, including the cost parameters of the former iodine production facilities decommissioning project in Turkmenistan. Before the closure, these facilities were producing the iodine from the underground mineral water by the methods of charcoal adsorption. Balkanabat iodine and Khazar chemical plants' sites remediation, transportation and disposal campaigns main results could be seen. The rehabilitated area covers 47.5 thousand square meters. The remediation equipment main characteristics, technical solutions and rehabilitation operations performed are indicated also. The report shows the types of the waste shipping containers, the quantity and nature of the logistics operations. The project waste turnover is about 2 million ton-kilometers. The problems encountered during the remediation of the Khazar chemical plant site are discussed: undetected waste quantities that were discovered during the operational activities required the additional volume of the disposal facility. The additional repository wall superstructure was designed and erected to accommodate this additional waste. There are data on the volume and characteristics of the NORM waste disposed: 60.4 thousand cu.m. of NORM with total activity 1 439 x 10{sup 9} Bq (38.89 Ci) were disposed at all. This report summarizes the project implementation results, from 2009 to 15.02.2012 (the date of the repository closure and its placement under the controlled supervision), including monitoring results within a year after the repository closure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LOOKING DEEP INTO THE CAT'S EYE: STRUCTURE AND ROTATION IN THE FAST WIND OF THE PN CENTRAL STAR OF NGC 6543

We present HST/STIS time-series spectroscopy of the central star of the 'Cat's Eye' planetary nebula NGC 6543. Intensive monitoring of the UV lines over a 5.8 hr period reveals well-defined details of large-scale structure in the fast wind, which are exploited to provide new constraints on the rotation rate of the central star. We derive characteristics of the line profile variability that support a physical origin due to corotating interaction regions (CIRs) that are rooted at the stellar surface. The recurrence time of the observed spectral signatures of the CIRs is used to estimate the rotation period of the central star and, adopting a radius between 0.3 and 0.6 R{sub Sun} constrains the rotational velocity to the range 54 km s{sup -1} {<=} v{sub rot} {<=} 108 km s{sup -1}. The implications of these results for single star evolution are discussed based on models calculated here for low-mass stars. Our models predict a subsurface convective layer in NGC 6543 which we argue to be causally connected to the occurrence of structure in the fast wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Fusion Power measurement at ITER

Nuclear fusion research aims to provide energy for the future in a sustainable way and the ITER project scope is to demonstrate the feasibility of nuclear fusion energy. ITER is a nuclear experimental reactor based on a large scale fusion plasma (tokamak type) device generating Deuterium - Tritium (DT) fusion reactions with emission of 14 MeV neutrons producing up to 700 MW fusion power. The measurement of fusion power, i.e. total neutron emissivity, will play an important role for achieving ITER goals, in particular the fusion gain factor Q related to the reactor performance. Particular attention is given also to the development of the neutron calibration strategy whose main scope is to achieve the required accuracy of 10% for the measurement of fusion power. Neutron Flux Monitors located in diagnostic ports and inside the vacuum vessel will measure ITER total neutron emissivity, expected to range from 1014 n/s in Deuterium - Deuterium (DD) plasmas up to almost 10{sup 21} n/s in DT plasmas. The neutron detection systems as well all other ITER diagnostics have to withstand high nuclear radiation and electromagnetic fields as well ultrahigh vacuum and thermal loads. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral Methods of Remote-Sensing Monitoring of Radioactive Substances and Toxic Chemicals

The physical principles of passive and active methods of remote-sensing monitoring of radioactive substances and toxic chemicals in accidental emissions (leaks) at nuclear fuel cycle objects are examined. The analytical possibilities of the most sensitive methods of remote-sensing monitoring, which are based on the advances made in UV and microwave range radiometry, laser IR-absorption spectroscopy, laser-induced fluorescence, and laser spark emission spectrometry, are discussed. The prospects for the development of spectral methods of remote-sensing monitoring in different ranges are analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Complementary system for long term measurements of radon exhalation rate from soil

A special set-up for continuous measurements of radon exhalation rate from soil is presented. It was constructed at Laboratory of Radiometric Expertise, Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN), Krakow, Poland. Radon exhalation rate was determined using the AlphaGUARD PQ2000 PRO (Genitron) radon monitor together with a special accumulation container which was put on the soil surface during the measurement. A special automatic device was built and used to raise and lower back onto the ground the accumulation container. The time of raising and putting down the container was controlled by an electronic timer. This set-up made it possible to perform 4–6 automatic measurements a day. Besides, some additional soil and meteorological parameters were continuously monitored. In this way, the diurnal and seasonal variability of radon exhalation rate from soil can be studied as well as its dependence on soil properties and meteorological conditions.

54 ENVIRONMENTAL SCIENCES↗

Containment at the Source during Waste Volume Reduction of Large Radioactive Components Using Oxylance High-Temperature Cutting Equipment - 13595

As a waste-volume reduction and management technique, highly contaminated Control Element Drive Mechanism (CEDM) housings were severed from the Reactor Pressure Vessel Head (RPVH) inside the San Onofre Unit 2 primary containment utilizing Oxylance high-temperature cutting equipment and techniques. Presented are relevant data concerning: - Radiological profiles of the RPVH and individual CEDMs; - Design overviews of the engineering controls and the specialized confinement housings; - Utilization of specialized shielding; - Observations of apparent metallurgical-contamination coalescence phenomena at high temperatures resulting in positive control over loose-surface contamination conditions; - General results of radiological and industrial hygiene air sampling and monitoring; - Collective dose and personnel contamination event statistics; - Lessons learned. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-108: Development of a Novel Clinical Neutron Dose Monitor for Proton Therapy Based On Twin TLD500 Chips in a Small PE Moderator

Purpose: In proton therapy, it could be desirable to measure out-of-field fast neutron doses at critical locations near and outside the patient body. Methods: The working principle of a novel clinical neutron dose monitor is verified by MCNPX simulation. The device is based on a small PE moderator of just 5.5cm side length for easy handling covered with a thermal neutron suppression layer. In the simulation, a polystyrene phantom is bombarded with a standard proton beam. The secondary thermal neutron flux produced inside the moderator by the impinging fast neutrons from the treatment volume is estimated by pairs of α-Al2O3:C (TLD500) chips which are evaluated offline after the treatment either by TL or OSL methods. The first chip is wrapped with 0.5mm natural Gadolinium foil converting the thermal neutrons to gammas via (n,γ) reaction. The second chip is wrapped with a dummy material. The chip centers have a distance of 2cm from each other. Results: The simulation shows that the difference of gamma doses in the TLD500 chips is correlated to the mean fast neutron dose delivered to the moderator material. Different outer shielding materials have been studied. 0.5mm Cadmium shielding is preferred for cost reasons and convenience. Replacement of PE moderator material by other materials like lead or iron at any place is unfavorable. The spatial orientation of the moderator cube is uncritical. Using variance reduction techniques like splitting/Russian roulette, the TLD500 gamma dose simulation give positive differences up to distances of 0.5m from the treatment volume. Conclusion: Applicability and basic layout of a novel clinical neutron dose monitor are demonstrated. The monitor measures PE neutron doses at locations outside the patient body up to distances of 0.5m from the treatment volume. Tissue neutron doses may be calculated using neutron kerma factors.

07 ISOTOPE AND RADIATION SOURCES↗

Long-term stability of the Leksell Gamma Knife{sup ®} Perfexion™ patient positioning system (PPS)

Purpose: To assess the long-term mechanical stability and accuracy of the patient positioning system (PPS) of the Leksell Gamma Knife{sup ®} Perfexion™ (LGK PFX). Methods: The mechanical stability of the PPS of the LGK PFX was evaluated using measurements obtained between September 2007 and June 2011. Three methods were employed to measure the deviation of the coincidence of the radiological focus point (RFP) and the PPS calibration center point (CCP). In the first method, the onsite diode test tool with single diode detector was used together with the 4 mm collimator on a daily basis. In the second method, a service diode test tool with three diode detectors was used biannually at the time of the routine preventive maintenance. The test performed with the service diode test tool measured the deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. The third method employed the conventional film pin-prick method. This test was performed annually for the 4 mm collimator at the time of the routine annual QA. To estimate the effect of the patient weight on the performance of the PPS, the focus precision tests were also conducted with varying weights on the PPS using a set of lead bricks. Results: The average deviations measured from the 641 daily focus precision tests were 0.1 ± 0.1, 0.0 ± 0.0, and 0.0 ± 0.0 mm, respectively, for the 4 mm collimator in the X (left/right of the patient), Y (anterior/posterior of the patient), and Z (superior/inferior of the patient) directions. The average of the total radial deviations as measured during ten semiannual measurements with the service diode test tool were 0.070 ± 0.029, 0.060 ± 0.022, and 0.103 ± 0.028 mm, respectively for the central, long, and short diodes for the 4 mm collimator. Similarly, the average total radial deviations measured during the semiannual measurements for the 4, 8, and 16 mm collimators and using the central diode were 0.070 ± 0.029, 0.097 ± 0.025, 0.159 ± 0.028 mm, respectively. The average values of the deviations as obtained from the five annual film pin-prick tests for the 4 mm collimator were 0.10 ± 0.06, 0.06 ± 0.09, and 0.03 ± 0.03 mm for the X, Y, Z stereotactic directions, respectively. Only a minor change was observed in the total radial deviations of the PPS as a function of the simulated patient weight up to 202 kg on the PPS. Conclusions: Excellent long-term mechanical stability and high accuracy was observed for the PPS of the LGK PFX. No PPS recalibration or any adjustment in the PPS was needed during the monitored period of time. Similarly, the weight on the PPS did not cause any significant disturbance in the performance of the PPS for up to 202 kg simulated patient weight.

61 RADIATION PROTECTION AND DOSIMETRY↗

Elaborating a First Version of a KIF For The Manche Surface Repository in France - 18060

The concept of a Key Information File developed in the framework of the RK and M international initiative has been tested against the case of the Manche surface repository. Work is still in progress. The aim is to issue a final version before end of year 2018, with the file for the decennial safety assessment update. The KIF will be part of the regulatory required Summary Memory File. Testing the KIF brought several lessons, on the elaboration process of such document, on the adaptation of the KIF concept to a surface repository, on the necessary evolution of the document over time. The Manche repository is the first repository operated by Andra, and the one at its most advanced stage. Therefore, it is de facto a pilot for similar issues encountered on other Andra's repositories. The difficulties encountered, the errors made and analyzed are the basis for improved provisions in other cases. It has been the case for the repository design, when the second surface repository was implemented in the Aube district. It is now the case for the cover design, for monitoring and for memory provisions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel application of cosmic rays for spent nuclear fuel monitoring - 15738

Monitoring nuclear waste and controlling spent nuclear fuel at its source is one of the main strategies to minimize the risks of nuclear proliferation and reduce potential homeland threats. Storage of high level waste from a fission reactor typically involves placing spent fuel in sealed dry casks. After the spent nuclear fuel has been placed inside the dry cask, the cask is welded, not allowing for visual inspection. Conventional methods for examining the interior of materials e.g., X-rays, are limited by the fact that they cannot penetrate very dense well-shielded objects. Instead, cosmic ray muons have the potential to allow for assessment of spent nuclear fuel stored within sealed dense dry casks. Objectives: 1.Exploit the ability of cosmic ray muons to penetrate high density materials allowing the distribution of materials within the object to be inferred from the muon tracks. 2. Develop a monitoring system that tracks the path of cosmic ray muons, including their deflection and attenuation, to identify the contents of a closed dry cask. Methods: - Monte-Carlo simulations using Geant4; - Bayesian decision theory for signal classification; - Wavelet analysis for noise cancellation; - Chaotic Neural Networks for signal encryption. Results: 1. Preliminary statistical analysis proved that the method is feasible and has the ability to identify the presence of spent nuclear fuel in a dry cask. 2. Using monoenergetic muons, a dry cask with one fuel assembly missing can be correctly identified with error rate <1%. Broader merit: Once completed, the proposed project for cosmic ray muon transport will enable a new and potentially transformative approach towards efficient, inexpensive and remote cosmic ray muon applications in archaeology, medicine and safeguarding of nuclear materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control Point Analysis comparison for 3 different treatment planning and delivery complexity levels using a commercial 3-dimensional diode array

To investigate the use of “Control Point Analysis” (Sun Nuclear Corporation, Melbourne, FL) to analyze and compare delivered volumetric-modulated arc therapy (VMAT) plans for 3 different treatment planning complexity levels. A total of 30 patients were chosen and fully anonymized for the purpose of this study. Overall, 10 lung stereotactic body radiotherapy (SBRT), 10 head-and-neck (H and N), and 10 prostate VMAT plans were generated on Pinnacle{sup 3} and delivered on a Varian linear accelerator (LINAC). The delivered dose was measured using ArcCHECK (Sun Nuclear Corporation, Melbourne, FL). Each plan was analyzed using “Sun Nuclear Corporation (SNC) Patient 6” and “Control Point Analysis.” Gamma passing percentage was used to assess the differences between the measured and planned dose distributions and to assess the role of various control point binning combinations. Of the different sites considered, the prostate cases reported the highest gamma passing percentages calculated with “SNC Patient 6” (97.5% to 99.2% for the 3%, 3 mm) and “Control Point Analysis” (95.4% to 98.3% for the 3%, 3 mm). The mean percentage of passing control point sectors for the prostate cases increased from 51.8 ± 7.8% for individual control points to 70.6 ± 10.5% for 5 control points binned together to 87.8 ± 11.0% for 10 control points binned together (2%, 2-mm passing criteria). Overall, there was an increasing trend in the percentage of sectors passing gamma analysis with an increase in the number of control points binned together in a sector for both the gamma passing criteria (2%, 2 mm and 3%, 3 mm). Although many plans passed the clinical quality assurance criteria, plans involving the delivery of high Monitor Unit (MU)/control point (SBRT) and plans involving high degree of modulation (H and N) showed less delivery accuracy per control point compared with plans with low MU/control point and low degree of modulation (prostate)

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance study of polycrystalline CVD diamond detectors for fast neutron monitoring

Diamond detectors using polycrystalline CVD diamond substrates of thickness 300μm and 100μm were fabricated for fast neutron monitoring application.. The characterization of detectors was carried out using various tests such as leakage current, capacitance and alpha particle response. The performance of detectors was evaluated for fast neutrons at different neutron yields. The results presented in this work demonstrate that the diamond detectors will be suitable for monitoring fast neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a tritium monitor combined with an electrochemical tritium pump using a proton conducting oxide

The detection of low level tritium is one of the key issues for tritium management in tritium handling facilities. Such a detection can be performed by tritium monitors based on proton conducting oxide technique. We tested a tritium monitoring system composed of a commercial proportional counter combined with an electrochemical hydrogen pump equipped with CaZr{sub 0.9}In{sub 0.1}O{sub 3-α} as proton conducting oxide. The hydrogen pump operated at 973 K under electrolysis conditions using tritiated water vapor (HTO). The proton conducting oxide extracts tritium molecules (HT) from HTO and tritium concentration is measured by the proportional counter. The advantage of the proposed tritium monitoring system is that it is able to convert HTO into molecular hydrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗