Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability & Maintainability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Eco–Friendly Solvent Engineered CsPbI 2.77 Br 0.23 Ink for Large–Area and Scalable High Performance Perovskite Solar Cells

The performance of large-area perovskite solar cells (PSCs) has been assessed for typical compositions, such as methylammonium lead iodide (MAPbI 3 ), using a blade coater, slot-die coater, solution shearing, ink-jet printing, and thermal evaporation. However, the fabrication of large-area all-inorganic perovskite films is not well developed. This study develops, for the first time, an eco-friendly solvent engineered all-inorganic perovskite ink of dimethyl sulfoxide (DMSO) as a main solvent with the addition of acetonitrile (ACN), 2-methoxyethanol (2-ME), or a mixture of ACN and 2-ME to fabricate large-area CsPbI 2.77 Br 0.23 films with slot-die coater at low temperatures (40–50 °C). The perovskite phase, morphology, defect density, and optoelectrical properties of prepared with different solvent ratios are thoroughly examined and they are correlated with their respective colloidal size distribution and solar cell performance. Here, the optimized slot-die-coated CsPbI 2.77 Br 0.23 perovskite film, which is prepared from the eco-friendly binary solvents dimethyl sulfoxide:acetonitrile (0.8:0.2 v/v), demonstrates an impressive power conversion efficiency (PCE) of 19.05%. Moreover, the device maintains ≈91% of its original PCE after 1 month at 20% relative humidity in the dark. It is believed that this study will accelerate the reliable manufacturing of perovskite devices.

binary and ternary solvent↗

The statistical defensibility of forensic proteomics

The U.S. Federal court system maintains very high standards for admissibility of scientific evidence. In particular, to allow such evidence into court, a judge must be satisfied it is both reliable, in other words, based on a robust, reproducible, and accurate method, and relevant, meaning it adds weight to the prosecution or defense claims in a case. In 1993, the U.S. Supreme Court issued landmark guidelines for judges considering whether or not to admit scientific testimony. The resulting Daubert criteria changed the forensic sciences in a profound way, leading investigators, researchers, and legal experts to question the scientific validity of established forensic methods that had been widely accepted for years. The Daubert criteria also caused a paradigm shift in the development of new forensic methods, forcing researchers to better prepare new techniques for use in an increasingly adversarial environment. In this chapter, we discuss the current state of forensic proteomics in the context of modern forensics. We present the Daubert criteria, discuss seven elements of a defensible method, and provide guidelines for building statistical defensibility of this emerging discipline.

Jarman, Kristin H.↗

Gain stabilization control system of the upgraded magnetic proton recoil neutron spectrometer at JET

Burning plasma experiments such as ITER and DEMO require diagnostics capable of withstanding the harsh environment generated by the intense neutron flux and to maintain stable operating conditions for times longer than present day systems. For these reasons, advanced control and monitoring (CM) systems will be necessary for the reliable operation of diagnostics. This paper describes the CM system of the upgraded magnetic proton recoil neutron spectrometer installed at the Joint European Torus focusing in particular on a technique for the stabilization of the gain of the photomultipliers coupled to the neutron detectors. The results presented here show that this technique provides good results over long time scales. The technique is of general interest for all diagnostics that employ scintillators coupled to photomultiplier tubes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

City of Klamath Falls, Oregon Geothermal Power Plant Feasibility Study

The purpose of the Klamath Falls project is to demonstrate the effectiveness of a combined thermal distribution system and power generation facility. The city of Klamath Falls operates a geothermal district heating system which would appear to be an attractive opportunity to install a power generation system. Since the two wells have operated reliably and consistently over many years, no new sources or resource exploration would be necessary. It appears that it will cost more to construct, operate, maintain and amortize a proposed geothermal facility than the long-term value of the power it would produce. The success of a future project will be determined by whether utility power production costs will remain low and whether costs of construction, operations, or financing may be reduced. There are areas that it would be possible to reduce construction cost. More detailed design could enable the city to obtain more precise quotes for components and construction, resulting in reduction in contingency projections. The current level of the contingency for uncertainty of costs is between $200,000 and $300,000. Another key issue with this project appears to be operation cost. While it is expected that only minimal routine monitoring and operating expenses will occur, the cost of water supply and waste water disposal represents nearly one quarter of the value of the power. If the cost of water alone could be reduced, the project could become viable. In addition, the projected cost of insurance may be lower than estimated under a city-wide policy. No provisions have been made for utilization of federal tax incentives. If a transaction with a third-party owner/taxpayer were to be negotiated, perhaps the net cost of ownership could be reduced. It is recommended that these options be investigated to determine if the costs and benefits could be brought together. The project has good potential, but like many alternative energy projects today, they only work economically if the federal tax incentives come into play.

15 GEOTHERMAL ENERGY↗

Measurement of Beam Energy in the Fermilab's Linac taken at the transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where 𝐻− particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped. of the extra electrons to become protons. The Booster requires stable beam energy at injection. The Linac extraction energy tuning has been performed using two Beam Velocity Monitors (a.k.a Griffin detectors) to maintain stable relative energy between the Booster and the Linac. Our goal is to control the Linac energy parameters using Machine Learning techniques to increase reliability and quality of beam delivered from Linac. The first step is to understand the data from the Linac extraction diagnostics; and develop reliable, accurate methods for energy measurement and control before implementing machine learning. There were two methods of energy measurement implemented, and the results of these are compared. The first method was time of flight measurements using the Phase probes inside B eam Position Monitors (BPM) that provide the beam’s phase of arrival data. The second method used the relation between beam position data from the BPMs and dispersion values from the 400MeV MAD-X model to calculate momentum variation. The results of these two energy measurement methods compare well as the Linac energy is varied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

I Can't Patch My OT Systems! A Look at CISA's KEVC Workarounds & Mitigations for OT

We examine the state of publicly available information about known exploitable vulnerabilities applicable to operational technology (OT) environments. Specifically, we analyze the Known Exploitable Vulnerabilities Catalog (KEVC) maintained by the US Department of Homeland Security Cybersecurity and Infrastructure Security Agency (CISA) to assess whether currently available data is sufficient for effective and reliable remediation in OT settings. Our team analyzed all KEVC entries through July 2025 to determine the extent to which OT environments can rely on existing remediation recommendations. We found that although most entries in the KEVC could affect OT environments, only 13% include vendor workarounds or mitigations as alternatives to patching. This paper also examines the feasibility of developing such alternatives based on vulnerability and exploit characteristics, and we present early evidence of success with this approach.

97 MATHEMATICS AND COMPUTING↗

Trial Implementation of a Multihazard Risk Assessment Framework for High-Impact Low-Frequency Power Grid Events

The Pacific Northwest National Laboratory developed a risk framework for modeling high-impact, low-frequency power grid events to support risk-informed decisions. In this research article, we briefly recap the framework and demonstrate its implementation for seismic and geomagnetic hazards using a benchmark reliability test system. We describe integration of a collection of models implemented to perform hazard analysis, fragility evaluation, consequence estimation and post-event restoration. We demonstrate the value of the framework as a multi-hazard power grid risk assessment and management tool. The research will benefit transmission planners and emergency planners by improving their ability to maintain a resilient grid infrastructure against impacts from major events.

power grid, risk assessment, seismic hazard, dynam↗

Conceptual core design of the molten metal fueled microreactor with self-regulating capability

The microreactor concept has received significant attention in the United States for its lower capital investment, siting flexibility and high mobility. A microreactor aims to provide reliable electricity in remote communities, mining areas, or isolated islands, which will save the high fuel transportation cost. Thus, minimizing the staff level for operating and maintaining a microreactor is desirable. The objective of the study is to design a self-regulated Molten Metal fueled microReactor core (MMR) and to demonstrate the self-regulating capability of the MMR core. The control of the reactor is solely relying on reactivity feedbacks from fuel temperature perturbation. Molten UMn (liquid form at the temperature over 720°C) was utilized as the fuel material in MMR due to the larger thermal expansion coefficient compared to the conventional solid fuel. The MMR core has a fast neutron spectrum, which corresponds to a small burnup reactivity swing. The core design parameters were selected based on DAKOTA, REBUS, and ANLHTP calculations. The MMR is designed to run for 10 years at a power level of 15 MWth. Furthermore, no refueling is needed during the reactor lifetime. The system dynamic analyses were performed, and it was found that the reactor can be self-regulating within a temperature range of 800 ± 80°C for a loss of heat sink transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Statistics-Based Threshold for the RMS-Energy Oscillation Detector

System operators and reliability coordinators currently rely on extensive baselining studies to set thresholds for their oscillation detectors. The resulting thresholds are based largely on engineering judgment and may vary significantly between organizations. In this paper, statistical distribution theory is used to derive a detection threshold for the widely deployed root-mean-square (RMS)-energy detector. This expression provides a theoretical basis for the detector's configuration, simplifies the process of selecting the threshold, and enables improved consistency among organizations that need to coordinate during system-wide events. Three methods for calculating the threshold using synchrophasor measurements are also proposed. These methods ensure that the threshold can be calculated reliably for various applications. Tests with simulated and field-measured data demonstrate that the statistics-based threshold provides consistent detection of grid disturbances while maintaining a low probability of false alarm.

Follum, James D.↗

Synchrophasor Based Tracking Three-Phase State Estimator and It's Applications

Electric power infrastructure is one of the critical resources of the nation. Its reliability in the face of natural or man-made catastrophes is of paramount importance for the economic and public health wellbeing of a modern society. Maintaining high levels of security for the high voltage transmission back bone of the electric supply network is a task requiring access to modern monitoring tools. These tools have been made particularly effective with the advent of synchronized phasor measurement units (PMUs) which became available in late 1990s, and have now become an indispensable for optimal monitoring, protection and control of the power grid. The present project was launched with an objective of demonstrating the value of the Wide Area Measurement System (WAMS) using PMUs and its applications on the Dominion Virginia Power High Voltage transmission grid. Virginia Tech is the birth place of PMUs, and was chosen to be the Principal Investigator of this project. In addition to Dominion Virginia Power, Quanta Technology of Raleigh, NC was selected to be co-Principal Investigators of this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AP1000{sup R} nuclear power plant safety overview for spent fuel cooling

The AP1000{sup R} plant is an 1100-MWe class pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and costs. The AP1000 design uses passive features to mitigate design basis accidents. The passive safety systems are designed to function without safety-grade support systems such as AC power, component cooling water, service water or HVAC. Furthermore, these passive features 'fail safe' during a non-LOCA event such that DC power and instrumentation are not required. The AP1000 also has simple, active, defense-in-depth systems to support normal plant operations. These active systems provide the first level of defense against more probable events and they provide investment protection, reduce the demands on the passive features and support the probabilistic risk assessment. The AP1000 passive safety approach allows the plant to achieve and maintain safe shutdown in case of an accident for 72 hours without operator action, meeting the expectations provided in the U.S. Utility Requirement Document and the European Utility Requirements for passive plants. Limited operator actions are required to maintain safe conditions in the spent fuel pool via passive means. In line with the AP1000 approach to safety described above, the AP1000 plant design features multiple, diverse lines of defense to ensure spent fuel cooling can be maintained for design-basis events and beyond design-basis accidents. During normal and abnormal conditions, defense-in-depth and other systems provide highly reliable spent fuel pool cooling. They rely on off-site AC power or the on-site standby diesel generators. For unlikely design basis events with an extended loss of AC power (i.e., station blackout) or loss of heat sink or both, spent fuel cooling can still be provided indefinitely: - Passive systems, requiring minimal or no operator actions, are sufficient for at least 72 hours under all possible pool heat load conditions. - After 3 days, several different means are provided to continue spent fuel cooling using installed plant equipment as well as off-site equipment with built-in connections. Even for beyond design basis accidents with postulated pool damage and multiple failures in the passive safety-related systems and in the defense-in-depth active systems, the AP1000 multiple spent fuel pool spray and fill systems provide additional lines of defense to prevent spent fuel damage. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Sensitivity in Targeted Single-Cell Proteomics by Coupling a Dual Ion Funnel Interface with Triple Quadrupole Mass Spectrometer

Single-cell proteomics (SCP) has emerged as a powerful approach for understanding cellular heterogeneity and biological processes at unprecedented resolution. However, the extremely limited protein content of individual cells (femtogram to picogram levels) pushes current mass spectrometry instrumentation to its sensitivity limits, creating a critical analytical bottleneck. While selected reaction monitoring (SRM) using triple quadrupole (QqQ) instruments 1 offers advantages in sensitivity and reproducibility for targeted proteomics quantification, SRM still struggles with sensitivity for quantification of moderate- or low-abundance proteins from single-cell sample amounts. Here, we report the development and systematic evaluation of a dual ion funnel interface designed to address the sensitivity limitation by significantly enhancing ion transmission efficiency in commercial QqQ mass spectrometers. The dual ion funnel interface, composed of a curved S-funnel followed by a conventional ion funnel, improves ion transmission efficiency while reducing chemical noise through selective ion focusing. The performance of the dual ion funnel interface was systematically compared to standard interface on a TSQ Vantage platform across samples with different levels of complexity. The dual funnel interface demonstrated to provide up to 25-fold improvement in sensitivity across a wide range of protein concentrations in different biological matrices (low complex mouse macrophage and high complex human cells). Critically, enhanced sensitivity was accompanied by increased analytical reproducibility with lower coefficient of variations. Most importantly, the dual funnel interface enabled reliable quantification of low-abundance proteins that were barely detectable or not detected by the standard interface, extending analysis to single-cell equivalent amounts while maintaining excellent reproducibility. These results demonstrate that the dual funnel interface addresses the critical bottleneck in quantitative targeted proteomics, providing a technological foundation for ultrasensitive targeted SCP that requires both high sensitivity and robust quantitative performance.

Min, Sehong↗

Investigations on caesium-free alternatives for H{sup −} formation at ion source relevant parameters

Negative hydrogen ions are efficiently produced in ion sources by the application of caesium. Due to a thereby induced lowering of the work function of a converter surface a direct conversion of impinging hydrogen atoms and positive ions into negative ions is maintained. However, due to the complex caesium chemistry and dynamics a long-term behaviour is inherent for the application of caesium that affects the stability and reliability of negative ion sources. To overcome these drawbacks caesium-free alternatives for efficient negative ion formation are investigated at the flexible laboratory setup HOMER (HOMogenous Electron cyclotron Resonance plasma). By the usage of a meshed grid the tandem principle is applied allowing for investigations on material induced negative ion formation under plasma parameters relevant for ion source operation. The effect of different sample materials on the ratio of the negative ion density to the electron density n{sub H{sup −}} /n{sub e} is compared to the effect of a stainless steel reference sample and investigated by means of laser photodetachment in a pressure range from 0.3 to 3 Pa. For the stainless steel sample no surface induced effect on the negative ion density is present and the measured negative ion densities are resulting from pure volume formation and destruction processes. In a first step the dependency of n{sub H{sup −}} /n{sub e} on the sample distance has been investigated for a caesiated stainless steel sample. At a distance of 0.5 cm at 0.3 Pa the density ratio is 3 times enhanced compared to the reference sample confirming the surface production of negative ions. In contrast for the caesium-free material samples, tantalum and tungsten, the same dependency on pressure and distance n{sub H{sup −}} /n{sub e} like for the stainless steel reference sample were obtained within the error margins: A density ratio of around 14.5% is measured at 4.5 cm sample distance and 0.3 Pa, linearly decreasing with decreasing distance to 7% at 1.5 cm. Thus, tantalum and tungsten do not significantly affect the negative ion density. First measurements conducted with LaB{sub 6} as well as with two types of diamond like carbon (DLC) n{sub H{sup −}} /n{sub e} of about 15% at 1 Pa were measured, which is comparable to the density ratio obtained for the stainless steel reference sample. At HOMER a surface induced enhancement of n{sub H{sup −}} is only observed when it exceeds the volume formation of H{sup −} which is also realistic for negative hydrogen ion sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of information technology impact on effective internal control in the University system

Information Technology (IT) plays a key role in internal control system in various organizations in terms of maintaining records and other internal services. Internal control system is defined as an efficient control procedures set up by firm to safeguard resources and to assure the reliability and accuracy of both financial and non-financial records in line with applicable governance and procedure to acquire the established goal and objectives. This paper focuses on the impact of IT on internal control system in the Nigerian universities. Data are collected from three different universities via questionnaire. Descriptive statistics is used to analyze the data; Chi-square is performed to test the hypothesis. The results of the hypothesis showed that IT has a positive relationship with the effective internal control activities in the University system. It is concluded that the adoption of IT will significantly improve the effectiveness of the internal control system operations in the University in terms of quality service delivery.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress in the development of ELM pace-making with non-axisymmetric magnetic perturbations in NSTX

The application of non-axisymmetric magnetic perturbations has been shown to destabilize edge-localized modes (ELMs) in the National Spherical Torus Experiment. This ELM-triggering effect is used to controllably introduce ELMs into lithium-enhanced ELM-free H-mode discharges, reducing the typical impurity accumulation while maintaining high energy confinement. Recent improvements to the triggering techniques are described. The perturbation waveform has been improved, with large amplitude, short duration perturbations allowing rapid, highly reliable triggering, with reduced braking of toroidal rotation. The rapid triggering allowed the ELM frequency to be increased to over 60 Hz, leading to a reduction in the average ELM size. Combined with improved gas fuelling, this method has resulted in periods of stationary global conditions, although plasma profiles do continue to evolve.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Control of Distributed Energy Resources using Model Predictive Control

In an isolated power system (rural microgrid), Distributed Energy Resources (DERs) such as renewable energy resources (wind, solar), energy storage and demand response can be used to complement fossil fueled generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation. The problem is formulated as a multi-objective optimization problem with the goals of minimizing fuel costs and changes in power output of diesel generators, minimizing costs associated with low battery life of energy storage and maintaining system frequency at the nominal operating value. Two control modes are considered for controlling the energy storage to compensate either net load variability or wind variability. Model predictive control (MPC) is used to solve the aforementioned problem and the performance is compared to an open-loop look-ahead dispatch problem. Simulation studies using high and low wind profiles, as well as, different MPC prediction horizons demonstrate the efficacy of the closed-loop MPC in compensating for uncertainties in wind and demand.

Mayhorn, Ebony T.↗

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗