Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Infrared spectroscopy investigation of Fe-promoted Rh catalysts supported on Titania and Ceria for CO hydrogenation

The nature of the promotional effect of Fe addition to Rh/TiO 2 and Rh/CeO 2 catalysts for CO hydrogenation was investigated using FT-IR spectroscopy in an ultrahigh vacuum compatible transmission IR cell. CO adsorption experiments on Rh and FeRh showed vibrational signatures characteristic of linear and bridge bound CO on Rh0 as well as geminal-dicarbonyl species associated with Rh + . Compared to TiO 2 , the CeO 2 -supported catalysts show increased dispersion, reflected by decreased particle size, and a lower signal for linear versus geminal-dicarbonyl bonded CO. The absorption frequencies for CO on Rh/CeO 2 are also redshifted relative to Rh/TiO 2 , which results from a weaker Rh–CO interaction, likely due to the increased reducibility of the CeO 2 support. Upon addition of Fe, a new spectral feature is observed and attributed to CO bound to Rh in close contact with Fe, likely as a surface alloy. CO hydrogenation on (Fe)Rh catalysts on both supports was also studied. Compared to bare Rh, Fe containing catalysts promote formate and methoxy species on the surface at lower temperature (180 °C), which suggests an enhancement in methanol selectivity by Fe addition. Furthermore, at higher temperatures (220 °C), the spectral features appear similar, further confirming the role of Fe as a disrupter of large Rh o crystallites and regulator of CO dissociation and CH 4 formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Looking at the axionic dark sector with ANITA

The ANITA experiment has recently observed two anomalous events emerging from well below the horizon. Even though they are consistent with tau cascades, a high energy Standard Model or Beyond the Standard Model explanation is challenging and in tension with other experiments. We study under which conditions the reflection of generic radio pulses can reproduce these signals. We propose that these pulses can be resonantly produced in the ionosphere via axion-photon conversion. This naturally explains the direction and polarization of the events and avoids other experimental bounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correcting thermal-emission-induced detector saturation in infrared spectroscopy

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens. These errors can arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent errors can be corrected by implementing several levels of optical attenuation that enable convergence testing of the measured reflectance or transmittance as the thermal-emission signal is reduced, or by applying correction factors that can be inferred by looking at the spectral regions where the sample is not expected to have a substantial temperature dependence.

47 OTHER INSTRUMENTATION↗

Remote atmospheric sensing with an airborne laser absorption spectrometer

A laser absorption spectrometer, using an infrared laser transmitter and a heterodyne radiometer, can be used from an aircraft or spacecraft to measure altitude profiles of air pollutants and other atmospheric constituents. The technique involves measurement of differential absorption at several wavelengths, using the diffusely reflecting earth's surface to provide a return signal. The pressure broadening of absorption lines allows one to discriminate between high and low altitude absorbers. Application of the technique to measurements of ozone, nitric oxide, and water vapor are presented. CO2 and CO lasers are considered as transmitters. The discussion includes altitude resolution limitations, atmospheric temperature dependence, and frequency stability requirements of the instrument.

Menzies, R. T.↗

Remote atmospheric sensing with an airborne laser absorption spectrometer

A laser absorption spectrometer, using an IR laser transmitter and a heterodyne radiometer, can be used from an aircraft or spacecraft to measure altitude profiles of air pollutants and other atmospheric constituents. The technique involves measurement of differential absorption at several wavelengths, using the diffusely reflecting earth's surface to provide a return signal. The pressure broadening of absorption lines allows one to discriminate between high and low altitude absorbers. Application of the technique to measurements of ozone, nitric oxide, and water vapor are presented. CO2 and CO lasers are considered as transmitters. The discussion includes altitude resolution limitations, atmospheric temperature dependence, and frequency stability requirements of the instrument.

Menzies, R. T.↗

Skylab altimeter observations over terrain

The author has identified the following significant results. Data obtained by Skylab radar altimeter (S193) over the continental U.S.A. for pass 1 of SL-3 were analyzed to relate radar return signal parameters such as range, power, and waveform to ground track terrain features. The altimeter, which was originally designed for ocean observations, performed predictably well over terrain with moderate to low relief. The maximum return from more complex areas corresponded usually to the lower flatter regions within the seven kilometer diameter footprint. Altimeter measured heights correlated with map topography with an rms deviation of + or - 30 m for terrain topography with large height dispersion (passes 1 and 28) and + or - 5 m for slowly varying terrain (passes 16, 17, and 18). Analysis of the waveform and statistical characteristics of the individual signals indicated that larger signal power was usually related to dominantly specular reflections from patches 100 m or larger. Results established the capability of a spacecraft altimeter system to observe characteristic radar signatures for different types of terrain within the bandwidth restrictions of the AGC and range tracker loops.

Shapiro, A.↗

Detecting a coal/shale interface

Detector, intended for use with longwall shearer, determines when cut has pierced through coal layer. Accelerometer measures hardness of material struck by penetrometer ram, while reflectometers measure reflectivity of surface on either side of penetrometer. Signals are combined in voting circuit that indicates "coal" or "shale", depending on information supplied by three sensors. It distinguishes by differences in accelerometer waveforms.

Broussard, P. H.↗

Satellite test of the isotropy of the one-way spe ed of light using ExTRAS

A test of the second postulate of special relativity, the universality of the speed of light, using the ExTRAS (Experiment on Timing Ranging and Atmospheric Sounding) payload to be flown on board a Russian Meteor-3M satellite (launch date January 1997) is proposed. The propagation time of a light signal transmitted from one point to another without reflection would be measured directly by comparing the phases of two hydrogen maser clocks, one on board and one on the ground, using laser or microwave time transfer systems. An estimated uncertainty budget of the proposed measurements is given, resulting in an expected sensitivity of the experiment of delta c/c is less than 8xl0(exp -10) which would be an improvement by a factor of approximately 430 over previous direct measurements and by a factor of approximately 4 over the best indirect measurement. The proposed test would require no equipment additional to what is already planned and so is of inherently low-cost. It could be carried out by anyone having access to a laser or microwave ground station and a hydrogen maser.

Wolf, Peter↗

High-order Two-way Artificial Boundary Conditions for Nonlinear Wave Propagation with Backscattering

When solving linear scattering problems, one typically first solves for the impinging wave in the absence of obstacles. Then, by linear superposition, the original problem is reduced to one that involves only the scattered waves driven by the values of the impinging field at the surface of the obstacles. In addition, when the original domain is unbounded, special artificial boundary conditions (ABCs) that would guarantee the reflectionless propagation of waves have to be set at the outer boundary of the finite computational domain. The situation becomes conceptually different when the propagation equation is nonlinear. In this case the impinging and scattered waves can no longer be separated, and the problem has to be solved in its entirety. In particular, the boundary on which the incoming field values are prescribed, should transmit the given incoming waves in one direction and simultaneously be transparent to all the outgoing waves that travel in the opposite direction. We call this type of boundary conditions two-way ABCs. In the paper, we construct the two-way ABCs for the nonlinear Helmholtz equation that models the laser beam propagation in a medium with nonlinear index of refraction. In this case, the forward propagation is accompanied by backscattering, i.e., generation of waves in the direction opposite to that of the incoming signal. Our two-way ABCs generate no reflection of the backscattered waves and at the same time impose the correct values of the incoming wave. The ABCs are obtained for a fourth-order accurate discretization to the Helmholtz operator; the fourth-order grid convergence is corroborated experimentally by solving linear model problems. We also present solutions in the nonlinear case using the two-way ABC which, unlike the traditional Dirichlet boundary condition, allows for direct calculation of the magnitude of backscattering.

Fibich, Gadi↗

Use of Pressure Sensitive Paint for Diagnostics in Turbomachinery Flows With Shocks

The technology of pressure sensitive paint (PSP) is well established in external aerodynamics. In internal flows in narrow channels and in turbomachinery cascades, however, there are still unresolved problems. In particular, the internal flows with complex shock structures inside highly curved channels present a challenge. It is not always easy and straightforward to distinguish between true signals and "ghost" images due to multiple internal reflections in narrow channels. To address some of the problems, investigations were first carried out in a narrow supersonic channel of Mach number 2.5. A single wedge or a combination of two wedges were used to generate a complex shock wave structure in the flow. The experience gained in a small supersonic channel was used for surface pressure measurements on the stator vane of a supersonic throughflow fan. The experimental results for several fan operating conditions are shown in a concise form, including performance map points, midspan static tap pressure distributions, and vane suction side pressure fields. Finally, the PSP technique was used in the NASA transonic flutter cascade to compliment flow visualization data and to acquire backwall pressure fields to assess the cascade flow periodicity. A summary of shortcomings of the pressure sensitive paint technology for internal flow application and lessons learned are presented in the conclusion of the paper.

Lepicovsky, Jan↗

Digital X-ray camera for quality evaluation three-dimensional topographic reconstruction of single crystals of biological macromolecules

The present invention provides a digital topography imaging system for determining the crystalline structure of a biological macromolecule, wherein the system employs a charge coupled device (CCD) camera with antiblooming circuitry to directly convert x-ray signals to electrical signals without the use of phosphor and measures reflection profiles from the x-ray emitting source after x-rays are passed through a sample. Methods for using said system are also provided.

Borgstahl, Gloria↗

Laser Infrared Desorption Spectroscopy to Detect Complex Organic Molecules on Icy Planetary Surfaces

Laser Desorption-Infrared Spectroscopy (LD-IR) uses an IR laser pulse to desorb surface materials while a spectrometer measures the emission spectrum of the desorbed materials (Figure 1). In this example, laser desorption operates by having the incident laser energy absorbed by near surface material (~10 microns in depth). This desorption produces a plume that exists in an excited state at elevated temperatures. A natural analog for this phenomenon can be observed when comets approach the sun and become active and individual molecular emission spectra can be observed in the IR [1,2,3,4,5]. When this occurs in comets, the same species that initially emit radiation down to the ground state are free to absorb it, reducing the amount of detectable emission features. The nature of our technique results in absorption not occurring, because the laser pulse could easily be moved away form the initial desorption plume, and still have better spatial resolution then reflectance spectroscopy. In reflectance spectroscopy, trace components have a relatively weak signal when compared to the entire active nature of the surface. With LDIR, the emission spectrum is used to identify and analyze surface materials.

Laser Desorption-Infrared Spectroscopy↗

Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a dispersive media, the effect of both phase and group indices have to be considered. Taking all these factors into account, a method was developed to measure targets through multiple regions of different materials and produce results that are absolute measurements of target position in three-dimensional space, rather than simply relative position. The environment in which the lidar measurements are taken must be broken down into separate regions of interest and each region solved for separately. In this case, there were three regions of interest: air, fused silica, and vacuum. The angular position of the target inside the chamber is solved using only phase index and phase velocity, while the ranging effects due to travel from air to glass to vacuum/air are solved with group index and group velocity. When all parameters are solved simultaneously, an absolute knowledge of the position of each target within an environmental chamber can be derived. Novel features of this innovation include measuring absolute position of targets through multiple dispersive and non-dispersive media, deconstruction of lidar raw data from a commercial off-the-shelf unit into reworkable parameters, and use of group velocities to reduce range data. Measurement of structures within a vacuum chamber or other harsh environment, such as a furnace, may now be measured as easily as if they were in an ambient laboratory. This analysis permits transformation of the raw data into absolute spatial units (e.g., mm). This technique has also been extended to laser tracker, theodolite, and cathetometer measurements through refractive media.

Kubalak, David↗

JPSS-1 VIIRS Radiometric Characterization and Calibration Based on Pre-Launch Testing

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the first Joint Polar Satellite System (JPSS) completed its sensor level testing on December 2014. The JPSS-1 (J1) mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. VIIRS instrument has 22 spectral bands covering the spectrum between 0.4 and 12.6 m. It is a cross-track scanning radiometer capable of providing global measurements twice daily, through observations at two spatial resolutions, 375 m and 750 m at nadir for the imaging and moderate bands, respectively. This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the government independent team to generate the at-launch baseline radiometric performance and the metrics needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs), radiance dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, spectral performance, response-vs-scan (RVS), and scattered light response. A set of performance metrics generated during the pre-launch testing program will be compared to both the VIIRS sensor specification and the SNPP VIIRS pre-launch performance.

VIIRS↗

Determining the Coalescence of Hotspots into Uniform Detonation Fronts in High Explosives

Microwave Interferometry (MI) offers the advantage of a continuous time measurement of detonation front velocity from detonation initiation to disassembly, which is an important step to assure the quality of stockpile high explosives. However, the method is currently characterized by areas of poor signal strength, which lead to low confidence measurements. Experiments in inert materials were conducted to determine if reflective hot spots, pockets of plasma that form during detonation, are responsible due to varying hot spot concentrations. Instead, it was found that the copper tube used in a range of standard HE test configurations is the cause of the poor signal reception. Hot spots were represented by microwave reflective aluminum particles. The aluminum was mixed with Titanium Dioxide, a material electrically similar to the insensitive high explosive, triaminotrinitrobenzene (TATB), in volume percent fractions (VPFs) between 0 and 100% aluminum, in increments of 10%. Reflectivity was measured based on input and reflection received from a test apparatus with a layer representing undetonated explosive and another representing an approaching shockwave. The results showed no correlation between VPF and measured reflectivity test cases while enclosed in the standard copper tube. Upon further testing, each sample’s measured reflectivity independent of the copper enclosure did correlate with VPF. This revealed that the test enclosure currently used for MI measurements is causing poor MI signal reception, and new methods must be developed to account for this aberration in MI measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acoustic reflection contamination measurements in the 16-foot NASA Langley Transonic Wind Tunnel

The Propfan Test Assessment (PTA) contract, awarded recently to Lockheed by the NASA-Lewis Research Center, required a comprehesive series of near field acoustic measurements. These were to use transducers mounted on the surfaces on a one-ninth scale model of the Gulfstream G-II aircraft, modified to the PTA single propfan testbed configuration. The 16-foot Transonic Wind Tunnel at the NASA Langley Research Center was chosen as the facility to be used for these model acoustic tests. Since the tunnel was hard-walled, it is not clear to what extent the propfan noise signals, reaching the various transducers, might be contaminated by reflections from the walls. A Multidriver Acoustic Source was built, and using an impulse and time domain averaging technique, the reflection contaminations in the wind tunnel were measured at selected microphone locations. Results of the investigations of near field measurements exists, due to reflections from the hard walls of the wind tunnnel.

Burrin, R. H.↗

Intelligent Metasurfaces with Continuously Tunable Local Surface Impedance for Multiple Reconfigurable Functions

Electromagnetic metasurfaces can be characterized as intelligent if they are able to perform multiple tunable functions, with the desired response being controlled by a computer influencing the individual electromagnetic properties of each metasurface inclusion. Here, we present an example of an intelligent metasurface that operates in the reflection mode in the microwave frequency range. We numerically show that, without changing the main body of the metasurface, we can achieve tunable perfect absorption and tunable anomalous reflection. The tunability features can be implemented using mixed-signal integrated circuits (ICs), which can independently vary both the resistance and reactance, offering complete local control over the complex surface impedance. The ICs are embedded in the unit cells by connecting two metal patches over a thin grounded substrate and the reflection property of the intelligent metasurface can be readily controlled by a computer. Our intelligent metasurface can have a critical influence on future space-time modulated metasurfaces and a multitude of applications, such as beam steering, energy harvesting, and communications.

42 ENGINEERING↗

Nonresonant coherent amplitude transfer in attosecond four-wave-mixing spectroscopy

Attosecond four-wave mixing (FWM) spectroscopy using an extreme ultraviolet (XUV) pulse and two noncollinear near-infrared (NIR) pulses is employed to measure Rydberg wave packet dynamics resulting from XUV excitation of a 3s electron in atomic argon into a series of autoionizing 3s –1 np Rydberg states ~29 eV. The emitted signals from individual Rydberg states exhibit oscillatory structure and persist well beyond the expected lifetimes of the emitting Rydberg states. These results reflect substantial contributions of longer-lived Rydberg states to the FWM emission signals of each individually detected state. A wave packet decomposition analysis reveals that coherent amplitude transfer occurs predominantly from photoexcited 3s –1 (n + 1) p states to the observed 3s –1 np Rydberg states. The experimental observations are reproduced by time-dependent Schrödinger equation simulations using electronic structure and transition moment calculations. Finally, the theory highlights that coherent amplitude transfer is driven nonresonantly to the 3s –1 np states by the NIR light through 3s –1 (n + 1)s and 3s –1 (n – 1)d dark states during the FWM process.

74 ATOMIC AND MOLECULAR PHYSICS↗