Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Reflectin: Protein Driver of Dynamically Tunable Biophotonics; New Paradigm for Tunably Reconfigurable Materials

We discovered that the reflectins, with architecture and sequences unlike those of any other proteins known, exhibit a novel interplay between signal-controlled nucleation and growth of dynamically arrested liquid-liquid phase-segregated assemblies that uniquely enables the continuous and precise fine-tuning of physical properties governing the color and brightness of light reflected from the membrane-enclosed nanostructures that contain them. Our research included high-resolution structural analyses conducted at the DOE-BES user facilities of the Stanford Synchrotron Light Source and LBL National Laboratory’s Molecular Foundry, leveraging their capabilities for time-resolved SAXS and cryo-TEM with our ongoing genetic engineering, biophysical and computational analyses to identify the structural determinants and mechanisms governing the dynamic behaviors of the reflectins. We augmented these methods with EPR analyses that revealed for the first time the existence of a specific pathway of reflectin assembly. Using dynamic light scattering and continuously monitored circular dichroism and Raman microscopy, we elucidated the progression of structural changes underlying the mechanisms of signal-induced condensation, folding, assembly, liquefaction, dynamic arrest, regulation and reversal.

59 BASIC BIOLOGICAL SCIENCES↗

Quantifying Dynamic Signal Spread in Real-Time High-Energy X-ray Diffraction

Abstract Measured intensity in high-energy monochromatic X-ray diffraction (HEXD) experiments provides information regarding the microstructure of the crystalline material under study. The location of intensity on an areal detector is determined by the lattice spacing and orientation of crystals so that changes in the heterogeneity of these quantities are reflected in the spreading of diffraction peaks over time. High temporal resolution of such dynamics can now be experimentally observed using technologies such as the mixed-mode pixel array detector (MM-PAD) which facilitates in situ dynamic HEXD experiments to study plasticity and its underlying mechanisms. In this paper, we define and demonstrate a feature computed directly from such diffraction time series data quantifying signal spread in a manner that is correlated with plastic deformation of the sample. A distinguishing characteristic of the analysis is the capability to describe the evolution from the distinct diffraction peaks of an undeformed alloy sample through to the non-uniform Debye–Scherrer rings developed upon significant plastic deformation. We build on our previous work modeling data using an overcomplete dictionary by treating temporal measurements jointly to improve signal spread recovery. We demonstrate our approach in simulations and on experimental HEXD measurements captured using the MM-PAD. Our method for characterizing the temporal evolution of signal spread is shown to provide an informative means of data analysis that adds to the capabilities of existing methods. Our work draws on ideas from convolutional sparse coding and requires solving a coupled convex optimization problem based on the alternating direction method of multipliers.

Engineering↗

Strategies for Detecting Organic Liquids on Soils Using Mid-Infrared Reflection Spectroscopy

Stand-off monitoring for chemical spills can provide timely information for clean-up efforts and mid-infrared reflection-absorption spectroscopy is one approach being investigated. Anomaly and target detection strategies were examined for detection of four different low-volatility organic liquids on two different soil types. Several preprocessing and signal weighting strategies were studied. Anomaly detection for C-H bands was very good using second derivative preprocessing and provided similar performance to target detection approaches such as generalized least squares (GLS) and partial least squares (PLS) with detections at soil loads of approximately 0.6 to 1.5 mg/cm2. Good performance was also found for detection of P=O, O–H and C=O bands but the optimal strategy varied. The simplicity and generality of anomaly detection is attractive, however target detection provides more capability for classification.

54 ENVIRONMENTAL SCIENCES↗

Accuracy Analysis of a Robotic Radionuclide Inspection and Mapping System for Surface Contamination

The mapping of localized regions of radionuclide contamination in a building can be a time consuming and costly task. Humans moving hand-held radiation detectors over the target areas are subject to fatigue. A contamination map based on manual surveys can contain significant operator-induced inaccuracies. A Fanuc M16i light industrial robot has been configured for installation on a mobile aerial work platform, such as a tall forklift. When positioned in front of a wall or floor surface, the robot can map the radiation levels over a surface area of up to 3 m by 3 m. The robot's end effector is a commercial alpha-beta radiation sensor, augmented with range and collision avoidance sensors to ensure operational safety as well as to maintain a constant gap between surface and radiation sensors. The accuracy and repeatability of the robotically conducted contamination surveys is directly influenced by the sensors and other hardware employed. This paper presents an in-depth analysis of various non-contact sensors for gap measurement, and the means to compensate for predicted systematic errors that arise during the area survey scans. The range sensor should maintain a constant gap between the radiation counter and the surface being inspected. The inspection robot scans the wall surface horizontally, moving down at predefined vertical intervals after each scan in a meandering pattern. A number of non-contact range sensors can be employed for the measurement of the gap between the robot end effector and the wall. The nominal gap width was specified as 10 mm, with variations during a single scan not to exceed {+-} 2 mm. Unfinished masonry or concrete walls typically exhibit irregularities, such as holes, gaps, or indentations in mortar joints. These irregularities can be sufficiently large to indicate a change of the wall contour. The responses of different sensor types to the wall irregularities vary, depending on their underlying principles of operation. We explored capacitive, ultrasound, and optical Laser range sensors. The unshielded capacitive range sensors were found to be influenced by objects in their vicinity, and to have comparatively low sensitivity. Therefore they were not used for gap measurement. We did, however, use them successfully to detect obstacles in the field of motion of the sensor head. The four sensors pointing diagonally from four corners of the sensor head are capacitive range sensors, which stop the robot motion any time a pre-set threshold signal level is exceeded. Ultrasound range sensors were found to have good resolution. The ultrasound beam was frequently deflected sideways by the wall's roughness, resulting in a spurious signal peaks. On the other hand, ultrasound signals are inherently insensitive to variations of the optical surface properties. Laser range sensing proved to be generally less noisy than ultrasound measurements. The aforementioned sensitivity to the target surface's optical properties was not evident on grey, non-reflective surfaces. On such surfaces, laser range sensing was found to be superior to ultrasound measurements. Occasionally, however, surface reflectivity and specularity caused erroneous measurements. The computational burden of measuring and filtering the sensor data in real time made it impractical to control the robot directly based on sensor feedback. The robot performs a first horizontal surface range scan merely to gage the surface profile. During the subsequent passes, the robot records the radiation measurements, while recording the range data for the next pass, with the range sensor positioned below the radiation sensor. The decoupling of measurements from robot control prevents the robot controller from responding to spurious sensor signals, ensuring steadier and safer radiation surveying. The controller is configured to accept either optical or ultrasound range signals, so as to respond better to user-specific requirements. A detailed analysis of non-contact range sensors and control for the automated mapping of surface contamination has been presented. The Contamination Survey Machine was tested and is operational.

42 ENGINEERING↗

The geometry of signal space: a case study of direct mapping between seismic signals and event distribution

SUMMARY Under favourable circumstances, seismic waveforms corresponding to an ensemble of events related by a common, spatially distributed process collectively exhibit a regular, signal-space geometry. When events in the ensemble have a common, or nearly common, source mechanism, this geometry is a distorted image of the distribution of events in the source region. The signal-space image can be visualized using a relatively simple waveform alignment and projection operation. Ensemble waveform correlation measurements can be inverted to estimate the distribution of the events in the source region, up to an arbitrary rotation, reflection and scaling, with residual distortion. We demonstrate these concepts with synthetic waveforms and with observations of long-wall mining induced seismicity for which substantial ground truth information is available. Our experience with these data has implications for location, correlation detection and machine learning and possible application to studies of repeating events in induced, volcanic and glacial seismicity. Our results place limits on the widely held assumption that waveform correlation is a useful measure of event separation. We suggest that the constraints on event separation need to be evaluated in the context of a population of related events, whose waveforms sample the signal space image of the source region. A better indicator of event separation is the length of the shortest path in signal space along the image.

58 GEOSCIENCES↗

LL18-Signal Analysis-NDD2Ad (Final Report)

Under favorable circumstances, seismic waveforms corresponding to an ensemble of events related by a common, spatially-distributed process collectively exhibit a regular, signal-space geometry. When events in the ensemble have a common, or nearly common, source mechanism, this geometry is a distorted image of the distribution of events in the source region. The signal space image can be visualized using a relatively simple waveform alignment and projection operation. Ensemble waveform correlation measurements can be inverted to estimate the distribution of the events in the source region, up to an arbitrary rotation, reflection, and scaling with residual distortion. We demonstrate these concepts with synthetic waveforms and with observations of long-wall mining induced seismicity for which substantial ground truth information is available. Our experience with these data has implications for location, correlation detection and machine learning, and possible application to studies of repeating events in induced, volcanic, and glacial seismicity. Our results place limits on the widely-held assumption that waveform correlation is a useful measure of event separation. We suggest that the constraints on event separation need to be evaluated in the context of a population of related events, whose waveforms sample the signal space image of the source region. A better indicator of event separation is the length of the shortest path in signal space along the image.

58 GEOSCIENCES↗

The throughput calibration of the VERITAS telescopes

Context. The response of imaging atmospheric Cherenkov telescopes to incident γ -ray-initiated showers in the atmosphere changes as the telescopes age due to exposure to light and weather. These aging processes affect the reconstructed energies of the events and γ -ray fluxes. Aims. This work discusses the implementation of signal calibration methods for the Very Energetic Radiation Imaging Telescope Array System (VERITAS) to account for changes in the optical throughput and detector performance over time. Methods. The total throughput of a Cherenkov telescope is the product of camera-dependent factors, such as the photomultiplier tube gains and their quantum efficiencies, and the mirror reflectivity and Winston cone response to incoming radiation. This document summarizes different methods to determine how the camera gains and mirror reflectivity have evolved over time and how we can calibrate this changing throughput in reconstruction pipelines for imaging atmospheric Cherenkov telescopes. The implementation is validated against seven years of observations with the VERITAS telescopes of the Crab Nebula, which is a reference object in very-high-energy astronomy. Results. Regular optical throughput monitoring and the corresponding signal calibrations are found to be critical for the reconstruction of extensive air shower images. The proposed implementation is applied as a correction to the signals of the photomultiplier tubes in the telescope simulation to produce fine-tuned instrument response functions. This method is shown to be effective for calibrating the acquired γ -ray data and for recovering the correct energy of the events and photon fluxes. At the same time, it keeps the computational effort of generating Monte Carlo simulations for instrument response functions affordably low.

79 ASTRONOMY AND ASTROPHYSICS↗

Heterogeneous Multilayer Nanopores via Chemically Tuned Dielectric Breakdown for Single‐Molecule Sensing

Solid-state nanopores are powerful platforms for single-molecule sensing, yet their performance is often constrained by fabrication complexity, noise, and limited control over surface properties. Here we report a direct method to fabricate heterogeneous multilayer nanopores using chemically tuned controlled dielectric breakdown (CT-CDB). We integrate hBN, MoS 2 , or graphene atop a silicon nitride membrane to form five distinct bilayer and tri-layer architectures, with bare SiN x nanopore as a control. CT-CDB achieves pore formation reproducibly through material-stacks with high efficiency, good pore size control, and strong yield, validated by various characterizations. Transferrin protein translocation experiments, supported by simulations, reveal that multilayer configurations modulate protein conformations, ionic current blockade and dwell time distributions, reflecting combined effects of membrane type, interfacial chemistry, and local electric field gradients. A supervised machine learning framework is implemented to assist identifying multilayer structure effects embedded in signal signatures, with over 96% accuracy. This work presents a modular and scalable framework for functional nanopore engineering with complex structural integration, thereby expanding the potential of 2D materials in single-molecule sensing applications.

2D materials↗

AIRE-induced apoptosis is associated with nuclear translocation of stress sensor protein GAPDH

Highlights: Black-Right-Pointing-Pointer AIRE induces apoptosis in epithelial cells. Black-Right-Pointing-Pointer CARD domain of AIRE is sufficient for apoptosis induction. Black-Right-Pointing-Pointer AIRE induced apoptosis involves GAPDH translocation to the nuclei. Black-Right-Pointing-Pointer Deprenyl inhibits AIRE induced apoptosis. -- Abstract: AIRE (Autoimmune Regulator) has a central role in the transcriptional regulation of self-antigens in medullary thymic epithelial cells, which is necessary for negative selection of autoreactive T cells. Recent data have shown that AIRE can also induce apoptosis, which may be linked to cross-presentation of these self-antigens. Here we studied AIRE-induced apoptosis using AIRE over-expression in a thymic epithelial cell line as well as doxycycline-inducible HEK293 cells. We show that the HSR/CARD domain in AIRE together with a nuclear localization signal is sufficient to induce apoptosis. In the nuclei of AIRE-positive cells, we also found an increased accumulation of a glycolytic enzyme, glyceraldehyde-3-phosphate (GAPDH) reflecting cellular stress and apoptosis. Additionally, AIRE-induced apoptosis was inhibited with an anti-apoptotic agent deprenyl that blocks GAPDH nitrosylation and nuclear translocation. We propose that the AIRE-induced apoptosis pathway is associated with GAPDH nuclear translocation and induction of NO-induced cellular stress in AIRE-expressing cells.

60 APPLIED LIFE SCIENCES↗

Regulation of the Electric Charge in Phosphatidic Acid Domains

Although a minor component of the lipidome, phosphatidic acid (PA) plays a crucial role in nearly all signaling pathways involving cell membranes, in part because of its variable electrical charge in response to environmental conditions. To investigate how charge is regulated in domains of PA, we applied surface-sensitive X-ray reflectivity and fluorescence near-totalreflection techniques to determine the binding of divalent ions (Ca2+ at various pH values) to 1,2-dimyristoyl-sn-glycero-3-phosphate (DMPA) and to the simpler lipid dihexadecyl phosphate (DHDP) spread as monolayers at the air/water interface. We found that the protonation state of PA is controlled not only by the pKa and local pH but also by the strong affinity to PA driven by electrostatic correlations from divalent ions and the cooperative effect of the two dissociable protons, which dramatically enhance the surface charge. A precise theoretical model is presented providing a general framework to predict the protonation state of PA. Implications for recent experiments on charge regulation by hydrogen bonding and the role of pH in PA signaling are discussed in detail.

36 MATERIALS SCIENCE↗

Apertureless scanning microscope probe as a detector of semiconductor laser emission

An operating semiconductor laser has been studied using a scanning probe microscope. A shift of the resonance frequency of probe that is due to its heating by laser radiation has been analyzed. The observed shift is proportional to the absorbed radiation and can be used to measure the laser near field or its output power. A periodical dependence of the measured signal has been observed as a function of distance between the probe and the surface of the laser due to the interference of the outgoing and cantilever-reflected waves. Due to the multiple reflections resulting in the interference, the light absorption by the probe cantilever is greatly enhanced compared with a single pass case. Interaction of infrared emission of a diode laser with different probes has been studied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three dimensional full-wave nonlinear acoustic simulations: Applications to ultrasound imaging

Characterization of acoustic waves that propagate nonlinearly in an inhomogeneous medium has significant applications to diagnostic and therapeutic ultrasound. The generation of an ultrasound image of human tissue is based on the complex physics of acoustic wave propagation: diffraction, reflection, scattering, frequency dependent attenuation, and nonlinearity. The nonlinearity of wave propagation is used to the advantage of diagnostic scanners that use the harmonic components of the ultrasonic signal to improve the resolution and penetration of clinical scanners. One approach to simulating ultrasound images is to make approximations that can reduce the physics to systems that have a low computational cost. Here a maximalist approach is taken and the full three dimensional wave physics is simulated with finite differences. This paper demonstrates how finite difference simulations for the nonlinear acoustic wave equation can be used to generate physically realistic two and three dimensional ultrasound images anywhere in the body. A specific intercostal liver imaging scenario for two cases: with the ribs in place, and with the ribs removed. This configuration provides an imaging scenario that cannot be performed in vivo but that can test the influence of the ribs on image quality. Several imaging properties are studied, in particular the beamplots, the spatial coherence at the transducer surface, the distributed phase aberration, and the lesion detectability for imaging at the fundamental and harmonic frequencies. The results indicate, counterintuitively, that at the fundamental frequency the beamplot improves due to the apodization effect of the ribs but at the same time there is more degradation from reverberation clutter. At the harmonic frequency there is significantly less improvement in the beamplot and also significantly less degradation from reverberation. It is shown that even though simulating the full propagation physics is computationally challenging it is necessary to quantify ultrasound image quality and its sources of degradation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the effect of noise parameters of a 3D lidar on the error in estimating relief signatures of distant objects from 2D field intensity distributions of reflected radiation

We consider the influence of noise parameters of a 3D lidar and external background radiation on the error in estimating the relief signatures of distant objects from 2D field intensity distributions of the reflected radiation. A physical and mathematical model is developed to analyse the effect of noise. The dependence of the error in estimating the relief signatures at various signal-to-noise ratios is investigated taking into account the parameters of real multi-element photodetectors (MEPDs). The obtained results indicate the possibility of evaluating relief signatures of distant objects with high accuracy based on standard MEPDs simultaneously for a large number of points on the object’s surface with a signal-to-noise ratio of more than 4. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparison of Different NDE Signal Processing Techniques Based on Waveform Entropies Applied to Long Fiber Graphite/Epoxy Plates

This study compares different approaches for imaging the internal architecture of graphite/epoxy composites using backscattered ultrasound. Two cases are studied. In the first, near-surface defects in a thin graphite/epoxy plates are imaged. The same backscattered waveforms were used to produce peak-to-peak, logarithm of signal energy, as well as entropy images of different types. All of the entropy images exhibit better border delineation and defect contrast than the either peak-to-peak or logarithm of signal energy. The best results are obtained using the joint entropy of the backscattered waveforms with a reference function. Two different references are examined. The first is a reflection of the insonifying pulse from a stainless steel reflector. The second is an approximate optimum obtained from an iterative parametric search. The joint entropy images produced using this reference exhibit three times the contrast obtained in previous studies. These plates were later destructively analyzed to determine size and location of near-surface defects and the results found to agree with the defect location and shape as indicated by the entropy images. In the second study, images of long carbon graphite fibers (50% by weight) in polypropylene thermoplastic are obtained as a first step toward ultrasonic determination of the distributions of fiber position and orientation.

Entropy Imaging↗

Evaluation of sliding baseline methods for spatial estimation for cluster detection in the biosurveillance system

Background: The Centers for Disease Control and Prevention's (CDC's) BioSense system provides near-real time situational awareness for public health monitoring through analysis of electronic health data. Determination of anomalous spatial and temporal disease clusters is a crucial part of the daily disease monitoring task. Our study focused on finding useful anomalies at manageable alert rates according to available BioSense data history. Methods: The study dataset included more than 3 years of daily counts of military outpatient clinic visits for respiratory and rash syndrome groupings. We applied four spatial estimation methods in implementations of space-time scan statistics cross-checked in Matlab and C. We compared the utility of these methods according to the resultant background cluster rate (a false alarm surrogate) and sensitivity to injected cluster signals. The comparison runs used a spatial resolution based on the facility zip code in the patient record and a finer resolution based on the residence zip code. Results: Simple estimation methods that account for day-of-week (DOW) data patterns yielded a clear advantage both in background cluster rate and in signal sensitivity. A 28-day baseline gave the most robust results for this estimation; the preferred baseline is long enough to remove daily fluctuations but short enough to reflect recent disease trends and data representation. Background cluster rates were lower for the rash syndrome counts than for the respiratory counts, likely because of seasonality and the large scale of the respiratory counts. Conclusion: The spatial estimation method should be chosen according to characteristics of the selected data streams. In this dataset with strong day-of-week effects, the overall best detection performance was achieved using subregion averages over a 28-day baseline stratified by weekday or weekend/holiday behavior. Changing the estimation method for particular scenarios involving different spatial resolution or other syndromes can yield further improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Prevention of acute liver injury by suppressing plasma kallikrein-dependent activation of latent TGF-β

Highlights: • TGF-β contributes to the pathogenesis of acute liver injury (ALI). • PLK-dependent TGF-β activation occurs in/around macrophages in ALI mice. • R58 latency associated protein-degradation products serve as an indicator for ALI. • Inhibiting PLK suppresses apoptosis and improves survival rate of ALI mice. Acute liver injury (ALI) is highly lethal acute liver failure caused by different etiologies. Transforming growth factor β (TGF-β) is a multifunctional cytokine and a well-recognized inducer of apoptotic and necrotic cell death in hepatocytes. Latent TGF-β is activated partly through proteolytic cleavage by a serine protease plasma kallikrein (PLK) between the R58 and L59 residues of its propeptide region. Recently, we developed a specific monoclonal antibody to detect the N-terminal side LAP degradation products ending at residue R58 (R58 LAP-DPs) that reflect PLK-dependent TGF-β activation. This study aimed to explore the potential roles of PLK-dependent TGF-β activation in the pathogenesis of ALI. We established a mouse ALI model via the injection of anti-Fas antibodies (Jo2) and observed increases in the TGF-β1 mRNA level, Smad3 phosphorylation, TUNEL-positive apoptotic hepatocytes and R58-positive cells in the liver tissues of Jo2-treated mice. The R58 LAP-DPs were observed in/around F4/80-positive macrophages, while macrophage depletion with clodronate liposomes partly alleviated the Jo2-induced liver injury. Blocking PLK-dependent TGF-β activation using either the serine proteinase inhibitor FOY305 or the selective PLK inhibitor PKSI-527 or blocking the TGF-β receptor-mediated signaling pathway using SB431542 significantly prevented Jo2-induced hepatic apoptosis and mortality. Furthermore, similar phenomena were observed in the mouse model of ALI with the administration of acetaminophen (APAP). In summary, R58 LAP-DPs reflecting PLK-dependent TGF-β activation may serve as a biomarker for ALI, and targeting PLK-dependent TGF-β activation has potential as a therapeutic strategy for ALI.

60 APPLIED LIFE SCIENCES↗

Casting a wide signal net with future direct dark matter detection experiments

As dark matter (DM) direct detection experiments continue to improve their sensitivity they will inevitably encounter an irreducible background arising from coherent neutrino scattering. This so-called "neutrino floor" may significantly reduce the sensitivity of an experiment to DM-nuclei interactions, particularly if the recoil spectrum of the neutrino background is approximately degenerate with the DM signal. This occurs for the conventionally considered spin-independent (SI) or spin-dependent (SD) interactions. In such case, an increase in the experiment's exposure by multiple orders of magnitude may not yield any significant increase in sensitivity. The typically considered SI and SD interactions, however, do not adequately reflect the whole landscape of the well-motivated DM models, which includes other interactions. Since particle DM has not been detected yet in laboratories, it is essential to understand and maximize the detection capabilities for a broad variety of possible models and signatures. Here, we investigate the impact of the background arising from various neutrino sources on the discovery potential of a DM signal for a large class of viable DM-nucleus interactions and several potential futuristic experimental settings, with different target elements. For some momentum suppressed cross sections, large DM particle masses and heavier targets, we find that there is no suppression of the discovery limits due to neutrino backgrounds. Further, we explicitly demonstrate that inelastic scattering, which could appear in models with multicomponent dark sectors, would help to lift the signal degeneracy associated with the neutrino floor. This research could assist with mapping out the optimal DM detection strategy for the next generation of experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncovering a membrane-distal conformation of KRAS available to recruit RAF to the plasma membrane

The small GTPase KRAS is localized at the plasma membrane where it functions as a molecular switch, coupling extracellular growth factor stimulation to intracellular signaling networks. In this process, KRAS recruits effectors, such as RAF kinase, to the plasma membrane where they are activated by a series of complex molecular steps. Defining the membrane-bound state of KRAS is fundamental to understanding the activation of RAF kinase and in evaluating novel therapeutic opportunities for the inhibition of oncogenic KRAS-mediated signaling. We combined multiple biophysical measurements and computational methodologies to generate a consensus model for authentically processed, membrane-anchored KRAS. In contrast to the two membrane-proximal conformations previously reported, we identify a third significantly populated state using a combination of neutron reflectivity, fast photochemical oxidation of proteins (FPOP), and NMR. In this highly populated state, which we refer to as “membrane-distal” and estimate to comprise ~90% of the ensemble, the G-domain does not directly contact the membrane but is tethered via its C-terminal hypervariable region and carboxymethylated farnesyl moiety, as shown by FPOP. Subsequent interaction of the RAF1 RAS binding domain with KRAS does not significantly change G-domain configurations on the membrane but affects their relative populations. Overall, our results are consistent with a directional fly-casting mechanism for KRAS, in which the membrane-distal state of the G-domain can effectively recruit RAF kinase from the cytoplasm for activation at the membrane.

KRAS↗