SEARCH · Search NASA
Results for “STAND”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
CaloriSMART: Small-scale test-stand for rapid evaluation of active magnetic regenerator performance
We report operation of a device designed specifically for rapid experimental evaluation of performance of magnetocaloric materials in different magnetic fields using a compact active magnetic regenerator bed with a total volume of approximately 5 mL. Other features of the system include digital control of the rotating-permanent-magnet field source and custom dual-opposed syringe pump that enable precise tuning and coupling of the flow profile and the magnetic field profile. Performance of the device is demonstrated for flow volumes between 1 and 4 mL (utilization from 0.48 to 1.9), maximum magnetic fields of 1.13 and 1.45 T, and applied cooling powers from 0 to 20 W at frequencies from 0.5 to 4 Hz. A regenerator comprised of 25 g of 200 µm spherical Gd powder reached temperature spans of 19.3 K under no applied cooling load and 2.6 K under the maximum applied cooling load of 20 W. The device also achieves a very high specific exergetic cooling power of 73 W L -1 T -1 . Results obtained at two different maximum magnetic fields in the same device suggest a powerful new scaling for regenerator performance: the exergetic power quotient. The exergetic power quotient shows a simple scaling of device cooling performance with the amount of active material and the magnetic field strength. This suggests results from a small device correlate to expected performance of a larger regenerator, making the exergetic power quotient a well-suited parameter for evaluating functionality of active magnetic regenerators employing new magnetocaloric materials.
Long-term tree and stand growth dynamics after thinning of various intensities in a temperate mixed forest
Not Available
Standing on the Shoulders of Giants: Results From the Radiation Oncology Academic Development and Mentorship Assessment Project (ROADMAP)
Purpose: To analyze survey information regarding mentorship practices and cross-correlate the results with objective metrics of academic productivity among academic radiation oncologists at US Accreditation Council for Graduate Medical Education (ACGME)-accredited residency training programs. Methods and Materials: An institutional review board-approved survey for the Radiation Oncology Academic Development and Mentorship Assessment Project (ROADMAP) was sent to 1031 radiation oncologists employed at an ACGME-accredited residency training program and administered using an international secure web application designed exclusively to support data capture for research studies. Data collected included demographics, presence of mentorship, and the nature of specific mentoring activities. Productivity metrics, including number of publications, number of citations, h-index, and date of first publication, were collected for each survey respondent from a commercially available online database, and m-index was calculated. Results: A total of 158 academic radiation oncologists completed the survey, 96 of whom reported having an academic/scientific mentor. Faculty with a mentor had higher numbers of publications, citations, and h- and m-indices. Differences in gender and race/ethnicity were not associated with significant differences in mentorship rates, but those with a mentor were more likely to have a PhD degree and were more likely to have more time protected for research. Bivariate fit regression modeling showed a positive correlation between a mentor's h-index and their mentee's h-index (R{sup 2} = 0.16; P<.001). Linear regression also showed significant correlates of higher h-index, in addition to having a mentor (P=.001), included a longer career duration (P<.001) and fewer patients in treatment (P=.02). Conclusions: Mentorship is widely believed to be important to career development and academic productivity. These results emphasize the importance of identifying and striving to overcome potential barriers to effective mentorship.
Regional Lymph Nodes Radiation and Breast Cancer Related Lymphedema: Where We Stand
No abstract prepared.
Fabrication of free-standing NiCo{sub 2}O{sub 4} nanoarrays via a facile modified hydrothermal synthesis method and their applications for lithium ion batteries and high-rate alkaline batteries
Graphical abstract: Hydrothermal-synthesized NiCo{sub 2}O{sub 4} nanoflake arrays exhibit porous structure and high capacity as well as good cycling life for lithium ion batteries and alkaline batteries. - Highlights: • Self-supported NiCo{sub 2}O{sub 4} nanoflake arrays are prepared by a hydrothermal method. • NiCo{sub 2}O{sub 4} nanoflake arrays show high capacity and good cycling life. • Porous nanoflake arrays structure is favorable for fast ion/electron transfer. - Abstract: Self-supported NiCo{sub 2}O{sub 4} nanoflake arrays on nickel foam are prepared by a facile hydrothermal method. The obtained NiCo{sub 2}O{sub 4} nanoflakes with thicknesses of ∼25 nm grow vertically to the nickel foam substrate and form an interconnected porous network with pore diameters of 50–500 nm. As anode material of LIBs, the NiCo{sub 2}O{sub 4} nanoflake arrays show a high initial coulombic efficiency of 76%, as well as good cycling stability with a capacity of 880 mAh g{sup −1} at 0.5 A g{sup −1}, and 523 mAh g{sup −1} at 1.5 A g{sup −1} after 50 cycles. As the cathode of alkaline batteries, a high capacity of 95 mAh g{sup −1} is achieved at 2 A g{sup −1} and 94% retention is maintained after 10,000 cycles. The superior electrochemical performance is mainly due to the unique nanoflake arrays structure with large surface area and shorter diffusion length for mass and charge transport.
Brick-and-Mortar Synthesis of Free-standing Mesoporous Carbon Nanocomposite Membranes as Supports of Room Temperature Ionic Liquids for CO2 N2 Separation
Explore the source record for details and available documents.
Elastic free-standing RTIL composite membranes for CO2/N2 separation based on sphere-forming triblock/diblock copolymer blends
Not Available