Symmetries of migration related segments of all [001] coincidence site lattice tilt boundaries in (001) projections for all holohedral cubic materials

Utilizing bicrystallography in two dimensions (2D), the symmetries of migration related segments of Coincidence Site Lattice (CSL) boundaries are derived for projections along their [001] tilt axis in grain boundaries of crystalline materials that possess the holohedral point symmetry of the cubic system (i.e. m3m). These kinds of “edge-on” projections are typical for atomic resolution imaging of such tilt boundaries with Transmission Electron Microscopes (TEM). This fact facilitates the visual confirmation of our predictions by recently published Zcontrast scanning TEM investigations [H. Yang et al., Phil. Mag. 93 (2013) 1219] and many other TEM studies.

Coincidence Site Lattice (CSL) boundaries↗

Characterization of Sulfur and Nanostructured Sulfur Battery Cathodes in Electron Microscopy Without Sublimation Artifacts

Abstract Lithium sulfur (Li–S) batteries have the potential to provide higher energy storage density at lower cost than conventional lithium ion batteries. A key challenge for Li–S batteries is the loss of sulfur to the electrolyte during cycling. This loss can be mitigated by sequestering the sulfur in nanostructured carbon–sulfur composites. The nanoscale characterization of the sulfur distribution within these complex nanostructured electrodes is normally performed by electron microscopy, but sulfur sublimates and redistributes in the high-vacuum conditions of conventional electron microscopes. The resulting sublimation artifacts render characterization of sulfur in conventional electron microscopes problematic and unreliable. Here, we demonstrate two techniques, cryogenic transmission electron microscopy (cryo-TEM) and scanning electron microscopy in air (airSEM), that enable the reliable characterization of sulfur across multiple length scales by suppressing sulfur sublimation. We use cryo-TEM and airSEM to examine carbon–sulfur composites synthesized for use as Li–S battery cathodes, noting several cases where the commonly employed sulfur melt infusion method is highly inefficient at infiltrating sulfur into porous carbon hosts.

25 ENERGY STORAGE↗

Highly selective plasma-activated copper catalysts for carbon dioxide reduction to ethylene

There is an urgent need to develop technologies that use renewable energy to convert waste products such as carbon dioxide into hydrocarbon fuels. Carbon dioxide can be electrochemically reduced to hydrocarbons over copper catalysts, although higher efficiency is required. We have developed oxidized copper catalysts displaying lower overpotentials for carbon dioxide electroreduction and record selectivity towards ethylene (60%) through facile and tunable plasma treatments. Herein we provide insight into the improved performance of these catalysts by combining electrochemical measurements with microscopic and spectroscopic characterization techniques. Operando X-ray absorption spectroscopy and cross-sectional scanning transmission electron microscopy show that copper oxides are surprisingly resistant to reduction and copper + species remain on the surface during the reaction. Furthermore, our results demonstrate that the roughness of oxide-derived copper catalysts plays only a partial role in determining the catalytic performance, while the presence of copper + is key for lowering the onset potential and enhancing ethylene selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Outstanding Natural Occurrence of TiO2-II at the Chicxulub Crater - Anatomy of A Shock-Produced High-Pressure Polymorph

Scientific drilling of the end-Cretaceous, approximately 180 kilometers-diameter Chicxulub crater (Yucatan Peninsula, Mexico) during IODP–ICDP (Integrated Ocean Drilling Program - International Continental Scientific Drilling Program) Expedition 364 has provided new insights into the formation, shock metamorphism, structural evolution, and thermal history of peak rings in large complex impact craters. An outstanding feature in uplifted granitoid rocks of the Chicxulub peak ring is the preservation of TiO2-II, an orthorhombic high-pressure polymorph of TiO2 with an alpha-PbO2 structure, produced during the impact from rutile and/or anatase at shock pressures of approximately 12.5-17.5 gigapascals. Unlike other mostly micro- and cryptocrystalline occurrences of TiO2-II at terrestrial impact sites, ejecta deposits, and in rare ultra-high pressure metamorphic rocks, TiO2-II at Chicxulub occurs as abundant euhedral crystals greater than or equal to 70 microns in size within aggregates of altered magmatic titanite. This mode of occurrence provides an excellent opportunity to investigate the crystallography and transformation kinetics of the shock-produced high-pressure polymorph using scanning electron microscopic, micro-Raman, electron backscatter diffraction (EBSD), focused ion beam (FIB), as well as transmission-EBSD and transmission electron microscopic (TEM) techniques. Here we present refined microstructural and new crystallographic results for TiO2-II at the Chicxulub crater.

Schmieder, Martin↗

Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope

Gas reactions studied by in situ electron microscopy can be used to capture the real-time morphological and microchemical transformations of materials at length scales down to the atomic level. In situ closed-cell gas reaction (CCGR) studies performed using (scanning) transmission electron microscopy (STEM) can separate and identify localized dynamic reactions, which are extremely challenging to capture using other characterization techniques. For these experiments, we used a CCGR holder that utilizes microelectromechanical systems (MEMS)-based heating microchips (hereafter referred to as "E-chips"). The experimental protocol described here details the method for performing in situ gas reactions in dry and wet gases in an aberration-corrected STEM. This method finds relevance in many different materials systems, such as catalysis and high-temperature oxidation of structural materials at atmospheric pressure and in the presence of various gases with or without water vapor. Here, several sample preparation methods are described for various material form factors. During the reaction, mass spectra obtained with a residual gas analyzer (RGA) system with and without water vapor further validates gas exposure conditions during reactions. Integrating an RGA with an in situ CCGR-STEM system can, therefore, provide critical insight to correlate gas composition with the dynamic surface evolution of materials during reactions. In situ/operando studies using this approach allow for detailed investigation of the fundamental reaction mechanisms and kinetics that occur at specific environmental conditions (time, temperature, gas, pressure), in real-time, and at high spatial resolution.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhanced visible-light-driven photocatalytic activities of Bi2Fe4O9/g-C3N4 composite photocatalysts

Highlights: • The novel Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} composite photocatalysts have been designed and prepared. • Combination of Bi{sub 2}Fe{sub 4}O{sub 9} and g-C{sub 3}N{sub 4} could enhance the visible-light-driven photocatalytic degradation for RhB. • The effects of Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} weight ratios on photocatalytic performance in the composite have been discussed. • The Z-scheme photocatalytic mechanism was proposed and discussed in detail. - Abstract: A series of Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} composite photocatalysts are prepared via a facile mixing-calcination method. The crystal structures of composites are investigated by X-ray Diffraction (XRD) and Fourier Transform Infrared Spectroscopy (FT-IR). The Field Emission Scanning Electron Microscope (FE-SEM) in combination with Energy Dispersive X-ray Spectroscopy (EDS) mapping analysis and Transmission Electron Microcopy (TEM) images illustrate the uniform distribution of constituent elements and clear interface between Bi{sub 2}Fe{sub 4}O{sub 9} and g-C{sub 3}N{sub 4} component. The visible-light-driven photocatalytic rates of Rhodamine B over Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} composites increase and then decrease with the increase of g-C{sub 3}N{sub 4} content. The effects of Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} weight ratios on photocatalytic performance are thoroughly discussed. Meanwhile, the active species trapping experiments and the electrochemical impedance spectra as well as the electronic energy-band structure estimation analysis demonstrate that the photocatalytic mechanism for Bi{sub 2}Fe{sub 4}O{sub 9}/g-C{sub 3}N{sub 4} composites is ascribed to the Z-scheme. In addition, the recyclability and stability experiments of the composite are also studied.

36 MATERIALS SCIENCE↗

A new Scanning Transmission X-ray Microscope at the ALS for operation up to 2500eV

We report on the design and construction of a higher energy Scanning Transmission X-ray Microscope on a new bend magnet beam line at the Advanced Light Source. Previously we have operated such an instrument on a bend magnet for C, N and O 1s NEXAFS spectroscopy. The new instrument will have similar performance at higher energies up to and including the S 1s edge at 2472eV. A new microscope configuration is planned. A more open geometry will allow a fluorescence detector to count emitted photons from the front surface of the sample. There will be a capability for zone plate scanning in addition to the more conventional sample scanning mode. This will add the capability for imaging a massive sample at high resolution over a limited field of view, so that heavy reaction cells may be used to study processes in-situ, exploiting the longer photon attenuation length and the longer zone plate working distances available at higher photon energy. The energy range will extend down to include the C1s edge at 300eV, to allow high energy NEXAFS microscopic studies to correlate with the imaging of organics in the same sample region of interest.

47 OTHER INSTRUMENTATION↗

Chapter 14: Electron Microscopy on Thin Films for Solar Cells

This chapter overviews the various techniques applied in scanning electron microscopy (SEM) and transmission electron microscopy (TEM), and highlights their possibilities and also limitations. It gives the various imaging and analysis techniques applied on a scanning electron microscope. The chapter shows that imaging is divided into that making use of secondary electrons (SEs) and of backscattered electrons (BSEs), resulting in different contrasts in the images and thus providing information on compositions, microstructures, and surface potentials. Whenever aiming for imaging and analyses at scales of down to the angstroms range, TEM and its related techniques are appropriate tools. In many cases, also SEM techniques provide the access to various material properties of the individual layers, not requiring specimen preparation as time consuming as TEM techniques. Finally, the chapter dedicates to cross-sectional specimen preparation for electron microscopy. The preparation decides indeed on the quality of imaging and analyses.

14 SOLAR ENERGY↗

Surface Detection in a STXM Microscope

We have modified scanning transmission x-ray microscopes (STXM) at the Canadian Light Source and the Advanced Light Source with total electron yield (TEY) detection (TEY-STXM). This provides improved surface-sensitive detection, simultaneous with existing bulk-sensitive transmission detection in the STXM microscopes. We have explored sample-current and channeltron-based electron yield detection. Both approaches provide improved surface sensitive imaging and spectroscopy, although channeltron-based detection is superior. TEY-STXM provides surface sensitive imaging of ultrathin films such as phase-separated Langmuir-Blodgett monolayer films, as well as differentiation of surface and bulk oxides of patterned metallic thin films. This paper will outline the experimental challenges of this method and the opportunities for correlative surface and bulk measurements of complex samples.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a cost effective surface-patterned transparent conductive coating as top-contact of light emitting diodes

Sol-gel process has been used to form indium zinc oxide films using an optimized combination of zinc to indium concentration in the precursor solutions. Different structures, like one (1D) and two-dimensional (2D) gratings and diffractive optical elements (DOEs) in the form of Fresnel lens are fabricated on the film surface of proposed top metal contact of LED by imprint soft lithography technique. These structures can enhance the LED's light extraction efficiency (LEE) or can shape the output beam pattern, respectively. Several characterizations are done to analyze the material and structural properties of the films. The presence of 1D and 2D gratings as well as DOEs is confirmed from field emission scanning electron and atomic force microscopes analyses. Although, X-ray diffraction shows amorphous nature of the film, but transmission electron microscopy study shows that it is nano crystalline in nature having fine particles (∼8 nm) of hexagonal ZnO. Shrinkage behaviour of gratings as a function of curing temperature is explained by Fourier transform infra-red spectra and thermo gravimetric-differential thermal analysis. The visible transmission and sheet resistance of the sample are found comparable to tin doped indium oxide (ITO). Therefore, the film can compete as low cost substitute of ITO as top metal contact of LEDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron Microscopy Laboratory MST-6: Instruments and Capabilities [Slides]

The Electron Microscopy Laboratory (EML) is a lab-wide facility, overseen by MST-6, that is available for use by qualified users. In FY12 the EML service contract costs were covered by funds from LDRD, BES, NE and other programs. Users can be trained to use the equipment independently or work collaboratively with other trained users or EML staff. Users are charged for the labor portion of their training. Most electron microscopy is done by staff or post-docs but some students are performing microscopy, particularly SEM. In the Materials Science Complex (MSC), there are two optical microscopes, two scanning electron microscopes (SEM’s), a SEM/ FIB (a SEM with a focused ion beam (FIB) column added), three transmission electron microscopes (TEM’s) and sample preparation equipment.

36 MATERIALS SCIENCE↗

Evolution of cementite morphology in pearlitic steel wire during wet wire drawing

The evolution of the cementite phase during wet wire drawing of a pearlitic steel wire has been followed as a function of strain. Particular attention has been given to a quantitative characterization of changes in the alignment and in the dimensions of the cementite phase. Scanning electron microscope observations show that cementite plates become increasingly aligned with the wire axis as the drawing strain is increased. Measurements in the transmission electron microscope show that the cementite deforms plastically during wire drawing , with the average thickness of the cementite plates decreasing from 19 nm ({epsilon} = 0) to 2 nm ({epsilon} = 3.7) in correspondence with the reduction in wire diameter. The deformation of the cementite is strongly related to plastic deformation in the ferrite, with coarse slip steps, shear bands and cracks in the cementite plates/particles observed parallel to either {l_brace}110{r_brace}{sub {alpha}} or {l_brace}112{r_brace}{sub {alpha}} slip plane traces in the ferrite.

36 MATERIALS SCIENCE↗

Correlative Raman spectroscopy and focused ion beam for targeted phase boundary analysis of titania polymorphs

Site-specific preparation of specimens using focused ion beam instruments for transmission electron microscopy is at the forefront of targeting regions of interest for nanoscale characterization. Typical methods of pinpointing desired features include electron backscatter diffraction for differentiating crystal structures and energy-dispersive X-Ray spectroscopy for probing compositional variations. Yet there are situations, notably in the titanium dioxide system, where these techniques can fail. Differentiating between the brookite and anatase polymorphs of titania is either excessively laborious or impossible with the aforementioned techniques. However, due to differences in bonding structure, Raman spectroscopy serves as an ideal candidate for polymorph differentiation. In this work, a correlative approach utilizing Raman spectroscopy for targeted focused ion beam specimen preparation was employed. Dark field imaging and diffraction in the transmission electron microscope confirmed the region of interest located via Raman spectroscopy and demonstrated the validity of this new method. Correlative Raman spectroscopy, scanning electron microscopy, and focused ion beam is shown to be a promising new technique for identifying site-specific preparation of nanoscale specimens in cases where conventional approaches do not suffice.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Origin of graphitic filaments on improving the electron field emission properties of negative bias-enhanced grown ultrananocrystalline diamond films in CH{sub 4}/Ar plasma

Microstructural evolution of bias-enhanced grown (BEG) ultrananocrystalline diamond (UNCD) films has been investigated using microwave plasma enhanced chemical vapor deposition in gas mixtures of CH{sub 4} and Ar under different negative bias voltages ranging from −50 to −200 V. Scanning electron microscopy and Raman spectroscopy were used to characterize the morphology, growth rate, and chemical bonding of the synthesized films. Transmission electron microscopic investigation reveals that the application of bias voltage induced the formation of the nanographitic filaments in the grain boundaries of the films, in addition to the reduction of the size of diamond grains to ultra-nanosized granular structured grains. For BEG-UNCD films under −200 V, the electron field emission (EFE) process can be turned on at a field as small as 4.08 V/μm, attaining a EFE current density as large as 3.19 mA/cm{sup 2} at an applied field of 8.64 V/μm. But the films grown without bias (0 V) have mostly amorphous carbon phases in the grain boundaries, possessing poorer EFE than those of the films grown using bias. Consequently, the induction of nanographitic filaments in grain boundaries of UNCD films grown in CH{sub 4}/Ar plasma due to large applied bias voltage of −200 V is the prime factor, which possibly forms interconnected paths for facilitating the transport of electrons that markedly enhance the EFE properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Formation of {gamma}-alumina nanorods in presence of alanine

Graphical abstract: Nanorod aluminas with a possible hexagonal symmetry, high surface area and relatively narrow pore size distribution were obtained. Research highlights: {yields} Research highlights {yields} Boehmite was prepared using a green sol-gel process in the presence of alanine. {yields} Nanorod aluminas with a high surface area were obtained. {yields} Addition of alanine would shape the size of the holes and crevices. {yields} The morphologies of the nanorods were revealed by transmission electron microscope. -- Abstract: Boehmite and alumina nanostructures were prepared using a simple green sol-gel process in the presence of alanine in water medium at room temperature. The uncalcined (dried at 200 {sup o}C) and the calcined materials (at 500, 600 and 700 {sup o}C for 4 h) were characterized using XRD, TEM, SEM, N{sub 2} physisorption and TGA. Nanorod aluminas with a possible hexagonal symmetry, high surface area and relatively narrow pore size distribution were obtained. The surface area was enhanced and crystallization was retarded as the alanine content increased. The morphologies of the nanoparticles and nanorods were revealed by a transmission electron microscope (TEM).

36 MATERIALS SCIENCE↗

Cross-sectional TEM specimen preparation for W/B{sub 4}C multilayer sample using FIB

A recent emergence of a cross-beam scanning electron microscopy (SEM)/focused-ion-beam (FIB) system have given choice to fabricate cross-sectional transmission electron microscopy (TEM) specimen of thin film multilayer sample. A 300 layer pair thin film multilayer sample of W/B{sub 4}C was used to demonstrate the specimen lift-out technique in very short time as compared to conventional cross-sectional sample preparation technique. To get large area electron transparent sample, sample prepared by FIB is followed by Ar{sup +} ion polishing at 2 kV with grazing incident. The prepared cross-sectional sample was characterized by transmission electron microscope.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magneto acoustical emission in nanocrystalline Mn–Zn ferrites

Graphical abstract: Mn{sub 0.4}Zn{sub 0.6}Fe{sub 2}O{sub 4} powders were prepared by microwave hydrothermal method. The powders were characterized by X-ray diffraction, transmission electron microscope. The powders were sintered at different temperatures 400, 500, 600, 700, 800 and 900 °C/30 min using microwave sintering method. The grain size was estimated by scanning electron microscope. The room temperature dielectric and magnetic properties were studied in the frequency range (100 kHz–1.8 GHz). The magnetization properties were measured upto 1.5 T. The acoustic emission has been measured along the hysteresis loops from 80 K to Curie temperature. It is found that the magneto-acoustic emission (MAE) activity along hysteresis loop is proportional to the hysteresis losses during the same loop. This law has been verified on series of polycrystalline ferrites and found that the law is valid whatever the composition, the grain size and temperature. It is also found that the domain wall creation/or annihilation processes are the origin of the MAE. - Highlights: • The AE been measured along the hysteresis loops from 80 K to Curie temperature. • The MAE activity along hysteresis loop is proportional to P{sub h} during the same loop. • It is found that the domain wall creation/or annihilation processes are the origin of the MAE. - Abstract: Mn{sub 0.4}Zn{sub 0.6}Fe{sub 2}O{sub 4} powders were prepared by microwave hydrothermal method. The powders were characterized by X-ray diffraction, transmission electron microscope. The powders were sintered at different temperatures 400, 500, 600, 700, 800 and 900 °C/30 min using microwave sintering method. The grain size was estimated by scanning electron microscope. The room temperature dielectric and magnetic properties were studied in the frequency range (100 kHz–1.8 GHz). The magnetization properties were measured upto 1.5 T. The acoustic emission has been measured along the hysteresis loops from 80 K to Curie temperature. It is found that the magneto-acoustic emission (MAE) activity along hysteresis loop is proportional to the hysteresis losses during the same loop. This law has been verified on series of polycrystalline ferrites and found that the law is valid whatever the composition, the grain size and temperature. It is also found that the domain wall creation/or annihilation processes are the origin of the MAE.

36 MATERIALS SCIENCE↗

Double patterning HSQ processes of zone plates for 10 nm diffraction limitedperformance

In e-beam lithography, fabrication of sub-20 nm dense structures is challenging. While there is a constant effort to develop higher resolution resist processes, the progress of increasing pattern density is slow. For zone plates, consisting of dense lines and spaces, the outermost zone width has been limited to slightly less than 20 nm due to effects such as low aerial image contrast, forward scattering, intrinsic resist resolution, and development issues. To circumvent these effects, we have successfully developed a new double patterning HSQ process, and as a result, we have fabricated zone plates of 10 and 12 nm using the process. We previously developed a double patterning process in which a dense zone plate pattern is sub-divided into two semi-isolated, complementary zone set patterns. These patterns are fabricated separately and then overlaid with high accuracy to yield the desired pattern. The key to success with this process is the accuracy of the overlay. For diffraction-limited zone plates, accuracy better than one-third of the smallest zone width is needed. In our previous work, the zone set patterns were formed using PMMA and gold electroplating, which were overlaid and aligned to the zero-level mark layer with sub-pixel accuracy using our internally developed algorithm. The complete zone plate fabrication was conducted in-house. With this process, we successfully fabricated zone plates of 15 nm outermost zone. Using this zone plate, we were able to achieve sub-15 nm resolution at 1.52 nm wavelength, the highest resolution ever demonstrated in optical microscopy at that time. We attempted to extend the process to fabricating 12 nm and smaller zones. However, the modest PMMA contrast, combined with a relatively large electron beam size compared to the target feature sized limited the process latitude. To overcome this problem, we developed a new overlay process based on high resolution negative tone resist of hydrogen silsesquioxane (HSQ). With the development in TMAH at 45 C, we can reliably achieve zone width as small as 8 nm with negligible line edge roughness in the semi-dense zone set. Such narrow zones in HSQ, however, detach easily from the gold plating base substrate needed for the electroplating step. We developed a process to condition the gold substrate with (3-mercaptopropyl) trimethoxysilane, or 3-MTP, which can form a homogeneous hydroxylation surface on gold surface and bond with hydroxyl in HSQ. Fig 2 shows the basic process steps of the double patterning HSQ process. Unlike the PMMA process, both zone sets are formed in HSQ and overlaid, and the complete zone plate pattern is converted to gold using electroplating in the final step. Using the new process, we successfully realized zone plates of 10 nm and 12 nm outermost zones. Fig. 3 shows the SEM micrographs of the zone plates outer regions. The zone plates are 30 nm thick in gold. To the best of our knowledge, these zone plates have the smallest zonal features ever fabricated using e-beam lithography. The complete zone plate fabrication was conducted in-house, using our vector scan electron beam lithography tool, the Nanowriter, which has a measured beam diameter of 6.5 nm (FWHM) at 100 keV. An internally developed, sub-pixel alignment algorithm, based on auto/cross-correlation methods, was used for the overlay. A 12 nm zone plate was tested with a full-field transmission x-ray microscope at the LBNL's Advanced Light Source. Fig. 4 shows an x-ray image of a 40 nm thick gold radial spoke pattern taken with the zone plate at 1.75 nm wavelength (707eV, FeL3 edge), along with the scanning transmission electron micrograph of same object. Numerous small features in the object can be seen in the x-ray image. Data analysis indicates that a near diffraction limited performance was achieved using the zone plate. In our presentation, we will discuss the details and subtleties of the overlay fabrication as well as the zone plate image results.