Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods-including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations-and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave breast imaging. Optical distortions imposed by the imaging tank and coupling bath diminished the effectiveness of the ray tracing approach; however, calibration through image registration techniques reliably produced scans of submillimeter accuracy. Tests of the system with breast-shaped phantoms demonstrated the successful implementation of the scanner for the intended application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanically scanned deployable antenna study

The conceptual design of a Mechanically Scanned Deployable Antenna which is launched by the STS (Space Shuttle) to provide radiometric brightness temperature maps of the Earth and oceans at selected frequency bands in the frequency range of 1.4 GHz to 11 GHz is presented. Unlike previous scanning radiometric systems, multiple radiometers for each frequency are required in order to fill in the resolution cells across the swath created by the 15 meter diameter spin stabilized system. This multiple beam radiometric system is sometimes designated as a ""whiskbroom'' system in that it combines the techniques of the scanning and ""pushbroom'' type systems. The definition of the feed system including possible feed elements and location, determination of the fundamental reflector feed offset geometry including offset angles and f/D ratio, preliminary estimates of the beam efficiency of the feed reflector system, a summary of reflector mesh losses at the proposed radiometric frequency bands, an overall conceptual configuration design and preliminary structural and thermal analyses are included.

Source record↗

Detection and quantification of residual alpha-phase in delta-stabilized plutonium

The temperature range of the {delta}-phase field of plutonium can be expanded by alloying with Group IIIA elements. Ga is a particularly potent {delta}-stabilizer and effectively stabilizes the {delta}-phase to room temperature. Due to a strong propensity towards solute redistribution during cooling through the {var_epsilon} {yields} {delta} phase field, regions of the material often do not contain enough solute to stabilize the {delta}-phase even after extensive homogenization annealing in the {delta}-phase field . The result is a small but persistent, fraction of {alpha}-phase in the material. A technique using differential scanning calorimetry to measure the enthalpy of transformation of the plutonium {alpha} {yields} {beta} transformation is described which can detect and quantify {alpha}-phase in a {delta}-phase matrix at levels as low as {approx} 0.1 wt. %. A set of Pu-1.7 atomic % Ga alloys was examined using the technique and found to contain 0.32 {+-} 0.06 weight % {alpha}-phase. Complications arise due to interference from the pressure-induced {alpha}{prime}-phase, and a peak separation method was developed to accurately measure the heat signal from each phase. Due to the presence of Ga in the {alpha}-phase, the onset temperature of the {alpha} {yields} {beta} transformation in these specimens was found to be 140.2 C, significantly higher than that for the transformation in pure plutonium, 126.2 C.

36 MATERIALS SCIENCE↗

Characterization of the correlation between the interfaces and failure behaviors for particle reinforced Mg–Li composites

The interfacial microstructure of SiC{sub p} or YAl{sub 2p} reinforced Mg–14Li–3Al matrix composites was comparatively characterized by scanning electron microscopy and electron probe microanalysis. A nanoindentation combined with scanning electron microscopy technique was used to characterize the interfacial mechanical properties between the reinforcements and matrix. The interfacial strength and failure behaviors for the composites were analyzed from the load–penetration curves and corresponding images. In situ tensile tests were used to observe the fracture and deformation processes with the aid of scanning electron microscopy. The results show that both the chemical and mechanical compatibilities between the YAl{sub 2} particles and LA143 matrix are better than those between the SiC particles and LA143 matrix. The interfacial breakage load for the SiC/LA143 composite is lower than that for the YAl{sub 2}/LA143 composite because of the worse chemical and mechanical compatibilities between the ceramic particles and metal matrix. Interfacial breakage is the main failure mechanism for the SiC/LA143 composite, while the particle breakage and matrix crack are the main failure mechanism for the YAl{sub 2}/LA143 composite. These may be related to the stronger interfacial bonding between the intermetallic particles and metal matrix. - Highlights: • The compatibility for YAl{sub 2} particle with LA143 matrix is better than SiC particle. • The strength of the YAl{sub 2}/LA143 interface is higher than the SiC/LA143 interface. • The main failure behavior for the SiC/LA143 composite is interfacial breakage. • The main failure behavior for YAl{sub 2}/LA143 composite is particle and matrix breakage. • The interfacial strength plays an important role on the composite failure behavior.

36 MATERIALS SCIENCE↗

Signal and data processing of small targets 1989; Proceedings of the Meeting, Orlando, FL, Mar. 27-29, 1989

The present conference on digital signal processing, association and filtering techniques, and multiple-sensor/multiple-tracking techniques, discusses single-frame velocity estimation, efficient target extraction for laser radar imagery, precision target tracking for small extended objects, IR clutter partitioning for matched filter design, the maximum-likelihood approach to gamma circumvention, position estimation for optical point targets using staring detector arrays, and a multiple-scan signal processing technique for area-moving target indication. Also discussed are a proportional integral estimator, the prediction of track purity in tracking performance evaluations, synchronization and fault-tolerance in a distributed tracker, the benefits of soft sensors and probabilistic fusion, and testing track initiation algorithms fusing two-dimensional tracks.

Drummond, Oliver E.↗

SU-E-T-266: Proton PBS Plan Design and Robustness Evaluation for Head and Neck Cancers

Purpose: To describe a newly designed proton pencil beam scanning (PBS) planning technique for radiotherapy of patients with bilateral oropharyngeal cancer, and to assess plan robustness. Methods: We treated 10 patients with proton PBS plans using 2 posterior oblique field (2F PBS) comprised of 80% single-field uniform dose (SFUD) and 20% intensity-modulated proton therapy (IMPT). All patients underwent weekly CT scans for verification. Using dosimetric indicators for both targets and organs at risk (OARs), we quantitatively compared initial plans and verification plans using student t-tests. We created a second proton PBS plan for each patient using 2 posterior oblique plus 1 anterior field comprised of 100% SFUD (3F PBS). We assessed plan robustness for both proton plan groups, as well as a photon volumetric modulated arc therapy (VMAT) plan group by comparing initial and verification plans. Results: The 2F PBS plans were not robust in target coverage. D98% for clinical target volume (CTV) degraded from 100% to 96% on average, with maximum change Δ D98% of −24%. Two patients were moved to photon VMAT treatment due to insufficient CTV coverage on verification plans. Plan robustness was especially weak in the low-anterior neck. The 3F PBS plans, however, demonstrated robust target coverage, which was comparable to the VMAT photon plan group. Doses to oral cavity were lower in the Proton PBS plans compared to photon VMAT plans due to no lower exit dose to the oral cavity. Conclusion: Proton PBS plans using 2 posterior oblique fields were not robust for CTV coverage, due to variable positioning of redundant soft tissue in the posterior neck. We designed 3-field proton PBS plans using an anterior field to avoid long heterogeneous paths in the low neck. These 3-field proton PBS plans had significantly improved plan robustness, and the robustness is comparable to VMAT photon plans.

60 APPLIED LIFE SCIENCES↗

Readout models for BaFBr 0.85 I 0.15 :Eu image plates

The linearity of the photostimulated luminescence process makes repeated image-plate scanning a viable technique to extract more dynamic range. In order to obtain a response estimate, two semi-empirical models for the readout fading of an image plate are introduced; they relate the depth distribution of activated photostimulated luminescence centers within an image plate to the recorded signal. Model parameters are estimated from image-plate scan series with BAS-MS image plates and the Typhoon FLA 7000 scanner for the hard x-ray image-plate diagnostic over a collection of experiments providing x-ray energy spectra whose approximate shape is a double exponential.

47 OTHER INSTRUMENTATION↗

Metal alloy microparticle tagging of UO 2 fuel pellets for nuclear forensics

A tagging strategy for UO 2 fuel pellets will be discussed which involves the creation of alloyed metal microparticles that can be tuned to create a unique identification (“barcode”) indicating provenance of the pellets. These specialized markers would contain high temperature resistant materials, such as Ti, Mo, and Cr, in small quantities such that they do not interfere with the performance of the pellets but are recoverable by standard analytical techniques. The Amazemet rePowder ultrasonic atomization system was used to manufacture the microparticles, and sample pellets were fabricated and sintered containing these dopants. Various techniques, such as Scanning Electron Microscopy (SEM) and Electron Probe Microanalysis (EPMA), were used to evaluate these sample pellets to determine if particles (and their alloy compositions) were recoverable. Details on how the particles were manufactured and characterized will be detailed, as well as results from their incorporation into test pellets. Next steps will involve the scale of this technique using more conventional mass production methods, as well as the implementation of other alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-Ray And Acoustic Measurements Yield Stiffnesses

Analytical technique combines ultrasonic scanning measurements of local velocity of sound in specimen of material with x-ray computed tomographic measurements of local mass density to compute local stiffness of material. Stiffnesses at various locations in specimen then used in finite-element mathematical model of elastic behavior of specimen to compute local stresses, local strains, and overall deformations. Technique enhances value of quantitative nondestructive x-ray and ultrasonic measurements. Especially useful in characterization of carbon/carbon composites and other advanced materials not homogeneous and for which customary simplifying assumption of constant density and/or constant stiffness not valid.

Madaras, Eric Irvine↗

A scoping review of non-destructive testing (NDT) techniques in building performance diagnostic inspections

Understanding building envelope thermodynamics is an essential foundation of building sciences, mainly due to the envelope’s role as a boundary layer for exterior environments, as well as a container and regulator of internal microclimates. This paper presents a scoping literature review of select Non-destructive Testing (NDT) techniques for building envelope scanning and surveying for thermodynamic diagnostics. The investigation focuses specifically on reviewing six NDT techniques: Ground Penetrating Radar (GPR), Light Detection and Ranging (LiDAR)/Laser Scanning, Thermography, Ultrasound, Close-Range Photogrammetry and Through Wall Imaging Radar (TWIR). The aim is to identify knowledge gaps in terms of their use in accurately characterizing envelope compositions for further integration in Building Energy Modeling (BEM). Each technique was evaluated according to set categories imbibed from the American Society of Heating, Refrigerating, and Air Conditioning Engineering (ASHRAE) Standard 211P that showcase the technique’s ability to extract various relevant information. A framework is then developed to inform users on how to use hybrid NDT-based workflows applied in building envelope energy audits. The study concludes by discussing possibilities of utilizing NDT in large-scale audit automation, BEM integration, and developing built environment policies focusing on increasing existing building performance through retrofitting design.

36 MATERIALS SCIENCE↗

Investigations of protons passing through the CR-39/PM-355 type of solid state nuclear track detectors

Solid State Nuclear Track Detectors of the CR-39/PM-355 type were irradiated with protons with energies in the range from 0.2 to 8.5 MeV. Their intensities and energies were controlled by a Si surface barrier detector located in an accelerator scattering chamber. The ranges of protons with energies of 6–7 MeV were comparable to the thickness of the PM-355 track detectors. Latent tracks in the polymeric detectors were chemically etched under standard conditions to develop the tracks. Standard optical microscope and scanning electron microscopy techniques were used for surface morphology characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XEDS STEM Tomography For 3D Chemical Characterization Of Nanoscale Particles

We present a tomography technique which couples scanning transmission electron microscopy (STEM) and X-ray energy dispersive spectrometry (XEDS) to resolve 3D distribution of elements in nanoscale materials. STEM imaging when combined with a symmetrically arranged XEDS detector design around the specimen overcomes many of the obstacles in 3D spectroscopic tomography of nanoscale materials and successfully elucidate the 3D chemical information in a large field of view of the TEM sample. We employed this technique to investigate 3D distribution of Nickel (Ni), Manganese (Mn) and Oxygen (O) in Li(NiMn)O2 battery cathode material. For this purpose, 2D elemental maps were acquired for a range of tilt angles and reconstructed to obtain 3D elemental distribution in an isolated Li(NiMnO2) nanoparticle. The results highlight the strength of this technique in 3D chemical analysis of nanoscale materials by successfully resolving Ni, Mn and O elemental distributions in 3D and discovering the new phenomenon of Ni surface segregation in this material. Furthermore, the comparison of simultaneously acquired HAADF STEM and XEDS STEM tomography results show that XEDS STEM tomography provides additional 3D chemical information of the material especially when there is low atomic number (Z) contrast in the material of interest.

Environmental Molecular Sciences Laboratory↗

Initial OSSE Sky Survey Observation: Deep Survey in the Virgo Region

The OSSE Virgo survey covered about 1% of the sky, using eight weeks of observing time on the Compton Gamma Ray Observatory, and was performed in conjunction with the EGRET and COMPTEL instruments on CGRO. A fundamental aspect of the survey was the development of data reduction techniques for the scanning data from the OSSE detectors. A direct algebraic approach for spatially deconvolving the data was developed. For the survey work, no background observations isolated from the survey region were acquired, unlike normal discrete source observations. The survey, reduction method covers the mapped region with a grid of pixels, and estimates the flux from each pixel by least-squares agreement with the data, assuming positivity constraints. This technique has led to the detection of compact sources at hard X-ray energies within the Virgo region, and the OSSE survey studies have been extended to the south galactic pole and north Ecliptic pole, with similar analysis techniques.

Cameron, Robert↗

Standard Characterization Techniques for Inorganic Phase Change Materials

Salt hydrates are promising candidates for phase change materials (PCMs) because of their low cost and high energy storage capacity. However, practical applications of salt hydrate based PCMs are limited due to their poor thermal cycling performance caused by phase separation and supercooling. Various techniques, including differential scanning calorimetry (DSC) and transient plane source (TPS) have been used to characterize salt hydrate based PCMs but may not provide full understanding of the degradation mechanism. In this manuscript, salt hydrate and graphite composites are prepared. Temperature history (T-History) method and X-ray diffraction (XRD) are utilized for measuring melting temperature, energy storage, and latent heat degradation of the PCM composites. Highlighting the importance of each technique and how each technique plays an important role in analyzing salt hydrates performance accurately. Temperature history, and X-ray diffraction are also used in conjunction to precisely predict the cause of degradation in salt hydrate PCMs with thermal cycling, as in most literatures the cause of degradation in salt hydrate are attributed to phase segregation, supercooling, and change in stichometry water concentration without any scientific validation.

Kumar, Navin↗

X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass. These scans show the clast to be approx.4.5 g, however (assuming a density of approx.3.5 g/cc). This is large enough for detailed studies including multiple geo-chronometers. This basalt clast is of particular interest as it is the largest Apollo 16 basalt, and it is the only mid-TiO2 basalt in the Apollo sample suite. By identifying the location of interesting clasts or grains within a sample, we will be able to make more informed decisions about where to cut a sample in order to best expose clasts of interest for future study. Moreover, knowing the location of internal defects (e.g., fractures) will allow more precise chipping and extraction of clasts or grains. By combining micro-CT scans with compositional techniques like micro x-ray fluorescence (particularly on sawn slabs), we will be able to provide even more comprehensive information to scientists trying to best select samples that fit their scientific needs.

Ziegler, R. A.↗

Synthetic CT: Simulating low dose single and dual energy protocols from a dual energy scan

Purpose: The choice of CT protocol can greatly impact patient dose and image quality. Since acquiring multiple scans at different techniques on a given patient is undesirable, the ability to predict image quality changes starting from a high quality exam can be quite useful. While existing methods allow one to generate simulated images of lower exposure (mAs) from an acquired CT exam, the authors present and validate a new method called synthetic CT that can generate realistic images of a patient at arbitrary low dose protocols (kVp, mAs, and filtration) for both single and dual energy scans. Methods: The synthetic CT algorithm is derived by carefully ensuring that the expected signal and noise are accurate for the simulated protocol. The method relies on the observation that the material decomposition from a dual energy CT scan allows the transmission of an arbitrary spectrum to be predicted. It requires an initial dual energy scan of the patient to either synthesize raw projections of a single energy scan or synthesize the material decompositions of a dual energy scan. The initial dual energy scan contributes inherent noise to the synthesized projections that must be accounted for before adding more noise to simulate low dose protocols. Therefore, synthetic CT is subject to the constraint that the synthesized data have noise greater than the inherent noise. The authors experimentally validated the synthetic CT algorithm across a range of protocols using a dual energy scan of an acrylic phantom with solutions of different iodine concentrations. An initial 80/140 kVp dual energy scan of the phantom provided the material decomposition necessary to synthesize images at 100 kVp and at 120 kVp, across a range of mAs values. They compared these synthesized single energy scans of the phantom to actual scans at the same protocols. Furthermore, material decompositions of a 100/120 kVp dual energy scan are synthesized by adding correlated noise to the initial material decompositions. The aforementioned noise constraint also allows us to compute feasible mAs values that can be synthesized for each kVp. Results: The single energy synthesized and actual reconstructed images exhibit identical signal and noise properties at 100 kVp and at 120 kVp, and across a range of mAs values. For example, the noise in both the synthesized and actual images at 100 kVp increases by {radical}(2) when the mAs is halved. The synthesized and actual material decompositions of a dual energy protocol show excellent agreement when the decomposition images are linearly weighted to form monoenergetic images at energies from 40 to 100 keV. For simulated single energy protocols with kVp between 80 and 140, the highest feasible mAs exceeds that of either initial scan. Conclusions: This work describes and validates the synthetic CT theory and algorithm by comparing its results to actual scans. Synthetic CT is a powerful new tool that allows users to realistically see how protocol selection affects CT images and enables radiologists to retrospectively identify the lowest dose protocol achievable that provides diagnostic quality images on real patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Low temperature synthesis and characterization of BiNbO{sub 4} powders

BiNbO{sub 4} powders, a potential microwave dielectric ceramic were prepared by both co-precipitation and solid state techniques. In the former method, an aqueous ammonium hydroxide was used to precipitate Bi{sup 3+} and Ta{sup 5+} cations as hydroxides simultaneously under basic conditions. It is observed that the co-precipitation produces BiNbO{sub 4} phase on heating at 600 deg. C, whereas complete phase formation occurs only at 800 deg. C in the case of solid state method. The phase contents and lattice parameters were studied by powder X-ray diffraction. The sequence of the reaction and phase evolution of BiNbO{sub 4} were also studied by the X-ray diffraction. The samples were characterized by the differential-thermal/thermo-gravimetric analyses and scanning electron microscopy techniques.

36 MATERIALS SCIENCE↗

Ultrasound spectroscopy: application on MMC and PMC materials

Resonant Ultrasound Spectroscopy (RUS) is a simple technique for measuring the second-order elastic constants and ultrasonic attenuation of solids. The technique is based on measuring the spectrum of mechanical resonances for a sample of known shape (usually a sphere, cylinder, or parallelepiped). This spectrum cannot be deconvoluted to deduce the elastic constants. Instead, an approximate spectrum is calculated from the known sample dimensions, its mass, and a set of 'guessed' elastic constants. A multidimensional minimization of the rms difference between the measured and calculated spectra enables us to deduce all the elastic constants of the solid from a single frequency scan. Currently, the technique can be applied to crystals of orthorhombic symmetry (9 elastic constants) or higher using desktop computers and software developed for this purpose. Composite materials, especially fiber composites, can take full advantage of the RUS technique as they typically have low symmetry. In this paper we summarize the RUS technique and provide examples of its application to the elastic characterization of both fiber reinforced MMC's, and fiber reinforced PMC's.

36 MATERIALS SCIENCE↗