Search NASA⌕ Search

SEARCH · Search NASA

Results for “Simulation Radiological Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Dosimetric and deformation effects of image-guided interventions during stereotactic body radiation therapy of the prostate using an endorectal balloon

Purpose: During stereotactic body radiation therapy (SBRT) for the treatment of prostate cancer, an inflatable endorectal balloon (ERB) may be used to reduce motion of the target and reduce the dose to the posterior rectal wall. This work assessed the dosimetric impact of manual interventions on ERB position in patients receiving prostate SBRT and investigated the impact of ERB interventions on prostate shape. Methods: The data of seven consecutive patients receiving SBRT for the treatment of clinical stage T1cN0M0 prostate cancer enrolled in a multi-institutional, IRB-approved trial were analyzed. The SBRT dose was 50 Gy in five fractions to a planning target volume (PTV) that included the prostate (implanted with three fiducial markers) with a 3-5 mm margin. All plans were based on simulation images that included an ERB inflated with 60 cm{sup 3} of air. Daily kilovoltage cone-beam computed tomography (CBCT) imaging was performed to localize the PTV, and an automated fusion with the planning images yielded displacements required for PTV relocalization. When the ERB volume and/or position were judged to yield inaccurate repositioning, manual adjustment (ERB reinflation and/or repositioning) was performed. Based on all 59 CBCT image sets acquired, a deformable registration algorithm was used to determine the dose received by, displacement of, and deformation of the prostate, bladder (BLA), and anterior rectal wall (ARW). This dose tracking methodology was applied to images taken before and after manual adjustment of the ERB (intervention), and the delivered dose was compared to that which would have been delivered in the absence of intervention. Results: Interventions occurred in 24 out of 35 (69%) of the treated fractions. The direct effect of these interventions was an increase in the prostate radiation dose that included 95% of the PTV (D95) from 9.6 {+-} 1.0 to 10.0 {+-} 0.2 Gy (p = 0.06) and an increase in prostate coverage from 94.0% {+-} 8.5% to 97.8% {+-} 1.9% (p = 0.03). Additionally, ERB interventions reduced prostate deformation in the anterior-posterior (AP) direction, reduced errors in the sagittal rotation of the prostate, and increased the similarity in shape of the prostate to the radiotherapy plan (increased Dice coefficient from 0.76 {+-} 0.06 to 0.80 {+-} 0.04, p = 0.01). Postintervention decreases in prostate volume receiving less than the prescribed dose and decreases in the voxel-wise displacement of the prostate, bladder, and anterior rectal wall were observed, which resulted in improved dose-volume histogram (DVH) characteristics. Conclusions: Image-guided interventions in ERB volume and/or position during prostate SBRT were necessary to ensure the delivery of the dose distribution as planned. ERB interventions resulted in reductions in prostate deformations that would have prevented accurate localization of patient anatomy.

60 APPLIED LIFE SCIENCES↗

Validation for 2D/3D registration II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set

Purpose: A new gold standard data set for validation of 2D/3D registration based on a porcine cadaver head with attached fiducial markers was presented in the first part of this article. The advantage of this new phantom is the large amount of soft tissue, which simulates realistic conditions for registration. This article tests the performance of intensity- and gradient-based algorithms for 2D/3D registration using the new phantom data set. Methods: Intensity-based methods with four merit functions, namely, cross correlation, rank correlation, correlation ratio, and mutual information (MI), and two gradient-based algorithms, the backprojection gradient-based (BGB) registration method and the reconstruction gradient-based (RGB) registration method, were compared. Four volumes consisting of CBCT with two fields of view, 64 slice multidetector CT, and magnetic resonance-T1 weighted images were registered to a pair of kV x-ray images and a pair of MV images. A standardized evaluation methodology was employed. Targets were evenly spread over the volumes and 250 starting positions of the 3D volumes with initial displacements of up to 25 mm from the gold standard position were calculated. After the registration, the displacement from the gold standard was retrieved and the root mean square (RMS), mean, and standard deviation mean target registration errors (mTREs) over 250 registrations were derived. Additionally, the following merit properties were computed: Accuracy, capture range, number of minima, risk of nonconvergence, and distinctiveness of optimum for better comparison of the robustness of each merit. Results: Among the merit functions used for the intensity-based method, MI reached the best accuracy with an RMS mTRE down to 1.30 mm. Furthermore, it was the only merit function that could accurately register the CT to the kV x rays with the presence of tissue deformation. As for the gradient-based methods, BGB and RGB methods achieved subvoxel accuracy (RMS mTRE down to 0.56 and 0.70 mm, respectively). Overall, gradient-based similarity measures were found to be substantially more accurate than intensity-based methods and could cope with soft tissue deformation and enabled also accurate registrations of the MR-T1 volume to the kV x-ray image. Conclusions: In this article, the authors demonstrate the usefulness of a new phantom image data set for the evaluation of 2D/3D registration methods, which featured soft tissue deformation. The author's evaluation shows that gradient-based methods are more accurate than intensity-based methods, especially when soft tissue deformation is present. However, the current nonoptimized implementations make them prohibitively slow for practical applications. On the other hand, the speed of the intensity-based method renders these more suitable for clinical use, while the accuracy is still competitive.

60 APPLIED LIFE SCIENCES↗

Nuclear Forensics: A Capability at Risk (Abbreviated Version)

Nuclear forensics is important to our national security. Actions, including provision of appropriate funding, are needed now to sustain and improve the nation's nuclear forensics capabilities. The Department of Homeland Security (DHS), working with cooperating agencies and national laboratories, should plan and implement a sustainable, effective nuclear forensics program. Nuclear forensics is the examination and evaluation of discovered or seized nuclear materials and devices or, in cases of nuclear explosions or radiological dispersals, of detonation signals and post-detonation debris. Nuclear forensic evidence helps law enforcement and intelligence agencies work toward preventing, mitigating, and attributing a nuclear or radiological incident. This report, requested by DHS, the National Nuclear Security Administration, and the Department of Defense, makes recommendations on how to sustain and improve U.S. nuclear forensics capabilities. The United States has developed a nuclear forensics capability that has been demonstrated in real-world incidents of interdicted materials and in exercises of actions required after a nuclear detonation. The committee, however, has concerns about the program and finds that without strong leadership, careful planning, and additional funds, these capabilities will decline. Major areas of concern include: Organization. The responsibility for nuclear forensics is shared by several agencies without central authority and with no consensus on strategic requirements to guide the program. This organizational complexity hampers the program and could prove to be a major hindrance operationally. Sustainability. The nation's current nuclear forensics capabilities are available primarily because the system of laboratories, equipment, and personnel upon which they depend was developed and funded by the nuclear weapons program. However, the weapons program's funds are declining. Workforce and Infrastructure. Personnel skilled in nuclear forensics are too few and are spread too thinly. Some key facilities are in need of replacement because they are old, outdated, and not built to modern environmental, health, and safety standards. Procedures and Tools. Most nuclear forensics techniques were developed to carry out Cold War missions and to satisfy a different, less restrictive set of environmental, health, and safety standards. Some of the equipment also does not reflect today's technical capabilities. The Executive Office of the President established the National Technical Nuclear Forensics Center under the direction of the Secretary of Homeland Security, to coordinate nuclear forensics in the United States. DHS's responsibility can only be carried out with the cooperation and support of the other agencies involved. The committee recommends that DHS and the other cooperating agencies should: 1. Streamline the organizational structure, aligning authority and responsibility; and develop and issue appropriate requirements documents. 2. Issue a coordinated and integrated implementation plan for fulfilling the requirements and sustaining and improving the program's capabilities. This plan would form the basis for the agencies' multi-year program budget requests. 3. Implement a plan to build and maintain an appropriately sized and composed nuclear forensics workforce, ensuring sufficient staffing at the national laboratories and support for university research, training programs, and collaborative relationships among the national laboratories and other organizations. 4. Adapt nuclear forensics to the challenges of real emergency situations, including, for example, conducting more realistic exercises that are unannounced and that challenge regulations and procedures followed in the normal work environment, and implementing lessons learned. The national laboratories should: 5. Optimize procedures and equipment through R&D to meet program requirements. Modeling and simulation should play an increased role in research, development, and planning. The nuclear forensics community should: 6. Develop standards and procedures for nuclear forensics that are rooted in the same underlying principles that have been recommended to guide modern forensic science. DHS and the other cooperating agencies should: 7. Devise and implement a plan that enables access to relevant information in databases including classified and proprietary databases for nuclear forensics missions. The Executive Office of the President and the Department of State, working with the community of nuclear forensics experts, should: 8. Determine the classes of data and methods that are to be shared internationally and explore mechanisms to accomplish that sharing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Benefits of Including Clinical Factors in Rectal Normal Tissue Complication Probability Modeling After Radiotherapy for Prostate Cancer

Purpose: To study the impact of clinical predisposing factors on rectal normal tissue complication probability modeling using the updated results of the Dutch prostate dose-escalation trial. Methods and Materials: Toxicity data of 512 patients (conformally treated to 68 Gy [n = 284] and 78 Gy [n = 228]) with complete follow-up at 3 years after radiotherapy were studied. Scored end points were rectal bleeding, high stool frequency, and fecal incontinence. Two traditional dose-based models (Lyman-Kutcher-Burman (LKB) and Relative Seriality (RS) and a logistic model were fitted using a maximum likelihood approach. Furthermore, these model fits were improved by including the most significant clinical factors. The area under the receiver operating characteristic curve (AUC) was used to compare the discriminating ability of all fits. Results: Including clinical factors significantly increased the predictive power of the models for all end points. In the optimal LKB, RS, and logistic models for rectal bleeding and fecal incontinence, the first significant (p = 0.011-0.013) clinical factor was 'previous abdominal surgery.' As second significant (p = 0.012-0.016) factor, 'cardiac history' was included in all three rectal bleeding fits, whereas including 'diabetes' was significant (p = 0.039-0.048) in fecal incontinence modeling but only in the LKB and logistic models. High stool frequency fits only benefitted significantly (p = 0.003-0.006) from the inclusion of the baseline toxicity score. For all models rectal bleeding fits had the highest AUC (0.77) where it was 0.63 and 0.68 for high stool frequency and fecal incontinence, respectively. LKB and logistic model fits resulted in similar values for the volume parameter. The steepness parameter was somewhat higher in the logistic model, also resulting in a slightly lower D{sub 50}. Anal wall DVHs were used for fecal incontinence, whereas anorectal wall dose best described the other two endpoints. Conclusions: Comparable prediction models were obtained with LKB, RS, and logistic NTCP models. Including clinical factors improved the predictive power of all models significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning

Purpose: Traditional computed tomography (CT) units provide a maximum scan field-of-view (sFOV) diameter of 50 cm and a limited bore size, which cannot accommodate a large patient habitus or an extended simulation setup in radiation therapy (RT). Wide-bore CT scanners with increased bore size were developed to address these needs. Some scanners have the capacity to reconstruct the CT images at an extended FOV (eFOV), through data interpolation or extrapolation, using projection data acquired with a conventional sFOV. Objects that extend past the sFOV for eFOV reconstruction may generate image artifacts resulting from truncated projection data; this may distort CT numbers and structure contours in the region beyond the sFOV. The purpose of this study was to evaluate the dosimetric impact of image artifacts from eFOV reconstruction with a wide-bore CT scanner in radiotherapy (RT) treatment planning. Methods: Testing phantoms (i.e., a mini CT phantom with equivalent tissue inserts, a set of CT normal phantoms and anthropomorphic phantoms of the thorax and the pelvis) were used to evaluate eFOV artifacts. Reference baseline images of these phantoms were acquired with the phantom centrally positioned within the sFOV. For comparison, the phantoms were then shifted laterally and scanned partially outside the sFOV, but still within the eFOV. Treatment plans were generated for the thoracic and pelvic anthropomorphic phantoms utilizing the Eclipse treatment planning system (TPS) to study the potential effects of eFOV artifacts on dose calculations. All dose calculations of baseline and test treatment plans were carried out using the same MU. Results: Results show that both body contour and CT numbers are altered by image artifacts in eFOV reconstruction. CT number distortions of up to -356 HU for bone tissue and up to 323 HU for lung tissue were observed in the mini CT phantom. Results from the large body normal phantom, which is close to a clinical patient size, show average CT number changes of up to -49 HU. Wider distribution (i.e., standard deviation) of the HU values was seen when the phantom was placed at more than 2.8 cm beyond the 50 cm sFOV. Anthropomorphic phantom studies with several standard beam configurations show that body contour distortion causes tumor dose calculation reduction of 3.0 and 1.9% for 6 and 23 MV x-rays, respectively, when not accounting for tissue heterogeneities during dose computation. When heterogeneity correction is used in planning, the competing effects of the body contour distortion and the CT number distortion cause a smaller error in tumor dose calculation. Less than 0.9% error in calculated dose was observed in volumetric modulated arc therapy (VMAT) treatment plans. Conclusions: The image artifacts from eFOV reconstruction alter the CT numbers and body contours of the imaged objects, which has the potential to produce inaccuracies in dose calculations during radiotherapy treatment planning. The radiation therapy team should be aware of these image artifacts and their effects on target dose calculations during CT simulation as well as treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

A GPU based high-resolution multilevel biomechanical head and neck model for validating deformable image registration

Purpose: Validating the usage of deformable image registration (DIR) for daily patient positioning is critical for adaptive radiotherapy (RT) applications pertaining to head and neck (HN) radiotherapy. The authors present a methodology for generating biomechanically realistic ground-truth data for validating DIR algorithms for HN anatomy by (a) developing a high-resolution deformable biomechanical HN model from a planning CT, (b) simulating deformations for a range of interfraction posture changes and physiological regression, and (c) generating subsequent CT images representing the deformed anatomy. Methods: The biomechanical model was developed using HN kVCT datasets and the corresponding structure contours. The voxels inside a given 3D contour boundary were clustered using a graphics processing unit (GPU) based algorithm that accounted for inconsistencies and gaps in the boundary to form a volumetric structure. While the bony anatomy was modeled as rigid body, the muscle and soft tissue structures were modeled as mass–spring-damper models with elastic material properties that corresponded to the underlying contoured anatomies. Within a given muscle structure, the voxels were classified using a uniform grid and a normalized mass was assigned to each voxel based on its Hounsfield number. The soft tissue deformation for a given skeletal actuation was performed using an implicit Euler integration with each iteration split into two substeps: one for the muscle structures and the other for the remaining soft tissues. Posture changes were simulated by articulating the skeletal structure and enabling the soft structures to deform accordingly. Physiological changes representing tumor regression were simulated by reducing the target volume and enabling the surrounding soft structures to deform accordingly. Finally, the authors also discuss a new approach to generate kVCT images representing the deformed anatomy that accounts for gaps and antialiasing artifacts that may be caused by the biomechanical deformation process. Accuracy and stability of the model response were validated using ground-truth simulations representing soft tissue behavior under local and global deformations. Numerical accuracy of the HN deformations was analyzed by applying nonrigid skeletal transformations acquired from interfraction kVCT images to the model’s skeletal structures and comparing the subsequent soft tissue deformations of the model with the clinical anatomy. Results: The GPU based framework enabled the model deformation to be performed at 60 frames/s, facilitating simulations of posture changes and physiological regressions at interactive speeds. The soft tissue response was accurate with a R{sup 2} value of >0.98 when compared to ground-truth global and local force deformation analysis. The deformation of the HN anatomy by the model agreed with the clinically observed deformations with an average correlation coefficient of 0.956. For a clinically relevant range of posture and physiological changes, the model deformations stabilized with an uncertainty of less than 0.01 mm. Conclusions: Documenting dose delivery for HN radiotherapy is essential accounting for posture and physiological changes. The biomechanical model discussed in this paper was able to deform in real-time, allowing interactive simulations and visualization of such changes. The model would allow patient specific validations of the DIR method and has the potential to be a significant aid in adaptive radiotherapy techniques.

60 APPLIED LIFE SCIENCES↗

Feature-space assessment of electrical impedance tomography coregistered with computed tomography in detecting multiple contrast targets

Purpose: Fusion of electrical impedance tomography (EIT) with computed tomography (CT) can be useful as a clinical tool for providing additional physiological information about tissues, but requires suitable fusion algorithms and validation procedures. This work explores the feasibility of fusing EIT and CT images using an algorithm for coregistration. The imaging performance is validated through feature space assessment on phantom contrast targets. Methods: EIT data were acquired by scanning a phantom using a circuit, configured for injecting current through 16 electrodes, placed around the phantom. A conductivity image of the phantom was obtained from the data using electrical impedance and diffuse optical tomography reconstruction software (EIDORS). A CT image of the phantom was also acquired. The EIT and CT images were fused using a region of interest (ROI) coregistration fusion algorithm. Phantom imaging experiments were carried out on objects of different contrasts, sizes, and positions. The conductive medium of the phantoms was made of a tissue-mimicking bolus material that is routinely used in clinical radiation therapy settings. To validate the imaging performance in detecting different contrasts, the ROI of the phantom was filled with distilled water and normal saline. Spatially separated cylindrical objects of different sizes were used for validating the imaging performance in multiple target detection. Analyses of the CT, EIT and the EIT/CT phantom images were carried out based on the variations of contrast, correlation, energy, and homogeneity, using a gray level co-occurrence matrix (GLCM). A reference image of the phantom was simulated using EIDORS, and the performances of the CT and EIT imaging systems were evaluated and compared against the performance of the EIT/CT system using various feature metrics, detectability, and structural similarity index measures. Results: In detecting distilled and normal saline water in bolus medium, EIT as a stand-alone imaging system showed contrast discrimination of 47%, while the CT imaging system showed a discrimination of only 1.5%. The structural similarity index measure showed a drop of 24% with EIT imaging compared to CT imaging. The average detectability measure for CT imaging was found to be 2.375 ± 0.19 before fusion. After complementing with EIT information, the detectability measure increased to 11.06 ± 2.04. Based on the feature metrics, the functional imaging quality of CT and EIT were found to be 2.29% and 86%, respectively, before fusion. Structural imaging quality was found to be 66% for CT and 16% for EIT. After fusion, functional imaging quality improved in CT imaging from 2.29% to 42% and the structural imaging quality of EIT imaging changed from 16% to 66%. The improvement in image quality was also observed in detecting objects of different sizes. Conclusions: The authors found a significant improvement in the contrast detectability performance of CT imaging when complemented with functional imaging information from EIT. Along with the feature assessment metrics, the concept of complementing CT with EIT imaging can lead to an EIT/CT imaging modality which might fully utilize the functional imaging abilities of EIT imaging, thereby enhancing the quality of care in the areas of cancer diagnosis and radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel methodology for 3D deformable dosimetry

Purpose: Interfraction and intrafraction variation in anatomic structures is a significant challenge in contemporary radiotherapy. The objective of this work is to develop a novel tool for deformable structure dosimetry, using a tissue-equivalent deformable gel dosimeter that can reproducibly simulate targets subject to deformation. This will enable direct measurement of integrated doses delivered in different deformation states, and the verification of dose deforming algorithms. Methods: A modified version of the nPAG polymer gel has been used as a deformable 3D dosimeter and phantom to investigate doses delivered to deforming tissue-equivalent geometry. The deformable gel (DEFGEL) dosimeter/phantom is comprised of polymer gel in a latex membrane, moulded (in this case) into a cylindrical geometry, and deformed with an acrylic compressor. Fifteen aluminium fiducial markers (FM) were implanted into DEFGEL phantoms and the reproducibility of deformation was determined via multiple computed tomography (CT) scans in deformed and nondeformed states before and after multiple (up to 150) deformations. Dose was delivered to the DEFGEL phantom in three arrangements: (i) without deformation, (ii) with deformation, and (iii) cumulative exposures with and without deformation, i.e., dose integration. Irradiations included both square field and a stereotactic multiple dynamic arc treatment adapted from a patient plan. Doses delivered to the DEFGEL phantom were read out using cone beam optical CT. Results: Reproducibility was verified by observation of interscan shifts of FM locations (as determined via CT), measured from an absolute reference point and in terms of inter-FM distance. The majority (76%) of points exhibited zero shift, with others shifting by one pixel size consistent with setup error as confirmed with a control sample. Comparison of dose profiles and 2D isodose distributions from the three arrangements illustrated complex spatial redistribution of dose in all three dimensions occurring as a result of the change in shape of the target between irradiations, even for a relatively simple deformation. Discrepancies of up to 30% of the maximum dose were evident from dose difference maps for three orthogonal planes taken through the isocenter of a stereotactic field. Conclusions: This paper describes the first use of a tissue-equivalent, 3D dose-integrating deformable phantom that yields integrated or redistributed dosimetric information. The proposed methodology readily yields three-dimensional (3D) dosimetric data from radiation delivery to the DEFGEL phantom in deformed and undeformed states. The impacts of deformation on dose distributions were readily seen in the isodose contours and line profiles from the three arrangements. It is demonstrated that the system is potentially capable of reproducibly emulating the physical deformation of an organ, and therefore can be used to evaluate absorbed doses to deformable targets and organs at risk in three dimensions and to validate deformation algorithms applied to dose distributions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Commissioning dose computation models for spot scanning proton beams in water for a commercially available treatment planning system

Purpose: To present our method and experience in commissioning dose models in water for spot scanning proton therapy in a commercial treatment planning system (TPS). Methods: The input data required by the TPS included in-air transverse profiles and integral depth doses (IDDs). All input data were obtained from Monte Carlo (MC) simulations that had been validated by measurements. MC-generated IDDs were converted to units of Gy mm{sup 2}/MU using the measured IDDs at a depth of 2 cm employing the largest commercially available parallel-plate ionization chamber. The sensitive area of the chamber was insufficient to fully encompass the entire lateral dose deposited at depth by a pencil beam (spot). To correct for the detector size, correction factors as a function of proton energy were defined and determined using MC. The fluence of individual spots was initially modeled as a single Gaussian (SG) function and later as a double Gaussian (DG) function. The DG fluence model was introduced to account for the spot fluence due to contributions of large angle scattering from the devices within the scanning nozzle, especially from the spot profile monitor. To validate the DG fluence model, we compared calculations and measurements, including doses at the center of spread out Bragg peaks (SOBPs) as a function of nominal field size, range, and SOBP width, lateral dose profiles, and depth doses for different widths of SOBP. Dose models were validated extensively with patient treatment field-specific measurements. Results: We demonstrated that the DG fluence model is necessary for predicting the field size dependence of dose distributions. With this model, the calculated doses at the center of SOBPs as a function of nominal field size, range, and SOBP width, lateral dose profiles and depth doses for rectangular target volumes agreed well with respective measured values. With the DG fluence model for our scanning proton beam line, we successfully treated more than 500 patients from March 2010 through June 2012 with acceptable agreement between TPS calculated and measured dose distributions. However, the current dose model still has limitations in predicting field size dependence of doses at some intermediate depths of proton beams with high energies. Conclusions: We have commissioned a DG fluence model for clinical use. It is demonstrated that the DG fluence model is significantly more accurate than the SG fluence model. However, some deficiencies in modeling the low-dose envelope in the current dose algorithm still exist. Further improvements to the current dose algorithm are needed. The method presented here should be useful for commissioning pencil beam dose algorithms in new versions of TPS in the future.

60 APPLIED LIFE SCIENCES↗

Modeling inter‐reader variability in clinical target volume delineation for soft tissue sarcomas using diffusion model

Abstract Background Accurate delineation of the clinical target volume (CTV) is essential in the radiotherapy treatment of soft tissue sarcomas. However, this process is subject to inter‐reader variability due to the need for clinical assessment of risk and extent of potential microscopic spread. This can lead to inconsistencies in treatment planning, potentially impacting treatment outcomes. Most existing automatic CTV delineation methods do not account for this variability and can only generate a single CTV for each case. Purpose This study aims to develop a deep learning‐based technique to generate multiple CTV contours for each case, simulating the inter‐reader variability in the clinical practice. Methods We employed a publicly available dataset consisting of fluorodeoxyglucose positron emission tomography (FDG‐PET), x‐ray computed tomography (CT), and pre‐contrast T1‐weighted magnetic resonance imaging (MRI) scans from 51 patients with soft tissue sarcoma, along with an independent validation set containing five additional patients. An experienced reader drew a contour of the gross tumor volume (GTV) for each patient based on multi‐modality images. Subsequently, two additional readers, together with the first one, were responsible for contouring three CTVs in total based on the GTV. We developed a diffusion model‐based deep learning method that is capable of generating arbitrary number of different and plausible CTVs to mimic the inter‐reader variability in CTV delineation. The proposed model incorporates a separate encoder to extract features from the GTV masks, leveraging the critical role of GTV information in accurate CTV delineation. Results The proposed diffusion model demonstrated superior performance with the highest Dice Index (0.902 compared to values below 0.881 for state‐of‐the‐art models) and the best generalized energy distance (GED) (0.209 compared to values exceeding 0.221 for state‐of‐the‐art models). It also achieved the second‐highest recall and precision metrics among the compared ambiguous image segmentation models. Results from both datasets exhibited consistent trends, reinforcing the reliability of our findings. Additionally, ablation studies exploring different model structures and input configurations highlighted the significance of incorporating prior GTV information for accurate CTV delineation. Conclusions The proposed diffusion model successfully generates multiple plausible CTV contours for soft tissue sarcomas, effectively capturing inter‐reader variability in CTV delineation.

Dong, Yafei [Yale Biomedical Imaging Institute Yal↗

A further investigation of the centroid-to-centroid method for stereotactic lung radiotherapy: A phantom study

Purpose: Our previous study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] proposed a deformable-registration-based patient setup strategy called the centroid-to-centroid (CTC) method, which can perform an accurate alignment of internal-target-volume (ITV) centroids between averaged four-dimensional computed tomography and cone-beam computed tomography (CBCT) images. Scenarios with variations between CBCT and simulation CT caused by irregular breathing and/or tumor change were not specifically considered in the patient study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] due to the lack of both a sufficiently large patient data sample and a method of tumor tracking. The aim of this study is to thoroughly investigate and compare the impacts of breathing pattern and tumor change on both the CTC and the translation-only (T-only) gray-value mode strategies by employing a four-dimensional (4D) lung phantom.Methods: A sophisticated anthropomorphic 4D phantom (CIRS Dynamic Thorax Phantom model 008) was employed to simulate all desired respiratory variations. The variation scenarios were classified into four groups: inspiration to expiration ratio (IE ratio) change, tumor trajectory change, tumor position change, tumor size change, and the combination of these changes. For each category the authors designed several scenarios to demonstrate the effects of different levels of breathing variation on both of the T-only and the CTC methods. Each scenario utilized 4DCT and CBCT scans. The ITV centroid alignment discrepancies for CTC and T-only were evaluated. The dose-volume-histograms (DVHs) of ITVs for two extreme cases were analyzed.Results: Except for some extreme cases in the combined group, the accuracy of the CTC registration was about 2 mm for all cases for both the single and the combined scenarios. The performance of the CTC method was insensitive to region-of-registration (ROR) size selections, as suggested by the comparable accuracy between 1 and 2 cm expansions of the ROR selections for the method. The T-only method was suitable for some single scenarios, such as trajectory variation, position variation, and size variation. However, for combined scenarios and/or a large variation in the IE ratio, the T-only method failed to produce reasonable registration results (within 3 mm). The discrepancy was close to, or even greater than, 1 cm. In addition, unlike the CTC method, the T-only method was sensitive to the ROR size selection. The DVH analysis suggested that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.Conclusions: The phantom study demonstrated that the CTC method was reliable for scenarios in which breathing pattern variation was involved. The T-only gray value method worked for some scenarios, but not for scenarios that involved an IE ratio variation. For scenarios involving position variation, the T-only method worked only with a careful selection of the ROR, whereas the CTC method was independent of ROR size as long as the ITVs were included in the ROR. One indication of the dose consequence analysis was that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis

Purpose: In digital breast tomosynthesis (DBT), a volumetric reconstruction of the breast is generated from a limited range of x-ray projections. One trade-off of DBT is resolution loss in the projections due to non-normal (i.e., oblique) x-ray incidence. Although degradation in image quality due to oblique incidence has been studied using empirical data and Monte Carlo simulations, a theoretical treatment has been lacking. The purpose of this work is to extend Swank's calculations of the transfer functions of turbid granular phosphors to oblique incidence. The model is ultimately used as a tool for optimizing the design of DBT detectors. Methods: A quantum-limited system and 20 keV x-rays are considered. Under these assumptions, the modulation transfer function (MTF) and noise power spectra (NPS) are derived using the diffusion approximation to the Boltzmann equation to model optical scatter within the phosphor. This approach is applicable to a nonstructured scintillator such as gadolinium oxysulfide doped with terbium (Gd{sub 2}O{sub 2}S:Tb), which is commonly used in breast imaging and which can reasonably approximate other detector materials. The detective quantum efficiency (DQE) is then determined from the Nishikawa formulation, where it is written as the product of the x-ray quantum detection efficiency, the Swank factor, and the Lubberts fraction. Transfer functions are calculated for both front- and back-screen configurations, which differ by positioning the photocathode at the exit or entrance point of the x-ray beam, respectively. Results: In the front-screen configuration, MTF and DQE are found to have considerable angular dependence, while NPS is shown to vary minimally with projection angle. As expected, the high frequency MTF and DQE are degraded substantially at large angles. By contrast, all transfer functions for the back-screen configuration have the advantage of significantly less angular dependence. Using these models, we investigated the possibility for optimizing the design of DBT detectors. As an example optimization strategy, the phosphor thickness which maximizes the DQE at a fixed frequency is analyzed. This work demonstrates that the optimal phosphor thickness for the front-screen is angularly dependent, shifting to lower thickness at higher angles. Conversely, the back-screen is not optimized by a single thickness but instead attains reasonably high DQE values over a large range of thicknesses. Although the back-screen configuration is not suited for current detectors using a glass substrate, it may prove to be preferred in future detectors using newly proposed plastic thin-film transistor (TFT) substrates. Conclusions: Using the diffusion approximation to the Boltzmann equation to model the spread of light in a scintillator, this paper develops an analytical model of MTF, NPS, and DQE for a phosphor irradiated obliquely. The model is set apart from other studies on oblique incidence in being derived from first principles. This work has applications in the optimization of DBT detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study of the secondary neutral radiation in proton therapy: Toward an indirect in vivo dosimetry

Purpose: Secondary particles produced in the collision of protons with beam modifiers are of concern in proton therapy. Nevertheless, secondary radiation can provide information on the dosimetric parameters through its dependency on the modulating accessories (range shifter and range modulating wheel). Relatively little data have been reported in the literature for low-energy proton beams. The present study aims at characterizing the neutron and photon secondary radiation at the low-energy proton therapy facility of the Centre Antoine Lacassagne (CAL), and studying their correlation to the dosimetric parameters to explore possible practical uses of secondary radiation in the treatment quality for proton therapy. Methods: The Monte Carlo code MCNPX was used to simulate the proton therapy facility at CAL. Neutron and photon fluence, {Phi}, and ambient dose equivalent per proton dose, H*(10)/D, were determined across the horizontal main plane spanning the whole treatment room. H*(10)/D was also calculated at two positions of the treatment room where dosimetric measurements were performed for validation of the Monte Carlo calculations. Calculations and measurements were extended to 100 clinical spread-out Bragg Peaks (SOBPs) covering the whole range of therapeutic dose rates (D/MU) employed at CAL. In addition, the values of D and MU were also calculated for each SOBP and the results analyzed to study the relationship between secondary radiation and dosimetric parameters. Results: The largest production of the secondary particles takes place at the modulating devices and the brass collimators located along the optical bench. Along the beam line and off the beam axis to 2.5 m away, H*(10)/D values ranged from 5.4 {mu}Sv/Gy to 5.3 mSv/Gy for neutrons, and were 1 order of magnitude lower for photons. H*(10)/D varied greatly with the distance and angle to the beam axis. A variation of a factor of 5 was found for the different range of modulations (SOBPs). The ratios between calculations and measurements were 2.3 and 0.5 for neutrons and photons, respectively, and remained constant for all the range of SOBPs studied, which provided validation for the Monte Carlo calculations. H*(10)/D values were found to correlate to the proton dose rate D/MU with a power fit, both for neutrons and photons. This result was exploited to implement a system to obtain D/MU values from the measurement of the integrated photon ambient dose equivalent H*(10) during treatment, which provides a method to control the dosimetric parameters D/MU and D. Conclusions: The treatment room at CAL is moderately polluted by secondary particles. The constant ratio between measurements and calculations for all SOBPs showed that simulations correctly predict the dosimetric parameters and the dependence of the production of secondary particles on the modulation. The correlation between H*(10)/D and D/MU is a useful tool for quality control and is currently used at CAL. This system works as an indirect in vivo dosimetry method, which is so far not feasible in proton therapy. This tool requires very simple instrumentation and can be implemented from the measurement of either photons or neutrons.

60 APPLIED LIFE SCIENCES↗

GIS-Based Modeling of Contaminated Soil Volumes at Multiple Sites in the Formerly Utilized Sites Remedial Action Program - 20149

The remediation of hazardous, toxic, and radioactive waste (HTRW) sites produces cost-related risks associated with the estimation of contaminated soil or debris volumes. Historical risk-management techniques include cost contingencies to cover volume uncertainties that affect project budgeting and decision-making. The Buffalo District teamed with project partners to lessen volume uncertainty and reduce project risks at multiple HTRW sites managed under the Formerly Utilized Sites Remedial Action Program (FUSRAP). Historical remedial investigations under FUSRAP commonly identified the presence of radiological material in site media, the associated human health risk, and then areas of remediation. To manage remedial execution and reduce risk, pre-design or remediation-phase sampling essentially 'chased' contamination, which was not conducive to efficient predictive budgeting derived from Feasibility Study (FS) cost analyses. The Buffalo District first optimized their approach to better understand volume uncertainty by utilizing the Argonne National Laboratory's Bayesian Approaches for Adaptive Spatial Sampling (BAASS) software [1]. BAASS processed soft data (e.g., gamma walk-over data) and spatial sampling data to estimate the lateral extent of contaminated soil irrespective of depth (i.e., gross contamination extent) and define areas of contaminant uncertainty. The software performed a binary transformation of contaminant concentrations at all sampling points based upon remedial action goals or a sum of ratios approach (i.e., clean, impacted, or range of impacts in soil). The model produced two-dimensional (horizontal) contaminant probability contours and statistical uncertainty in the sampling coverage and resulting contaminant extents. This method was translated vertically by partitioning the sampling data into depth brackets that produced a stacked representation of contaminant extents and uncertainty in the subsurface (i.e., similar to construction lifts). The results commonly led to a better understanding of project uncertainty and the need for sampling strategies that produce high-confidence soil volumes, which control costs. The BAASS-based delineations were eventually replaced by Empirical Bayesian Kriging (EBK) methods available in ArcGIS Spatial or 3D Analysts [2]. The EBK method calculates contaminant probability zones derived from user-controlled semivariograms of the spatial datasets. The resulting probability zones (e.g., 50% or 80% of contaminant probability) represent the two-dimensional surface delineation of the overall horizontal remedial area, similarly to BAASS. However, unlike BAASS, the vertical sampling data within these probability zones became vertical control points to contour a subterranean surface that connects subsurface points to the land-surface delineations of contamination. The resulting representation of horizontal and vertical impacts within an enclosed envelop (volume) of soil included uncertainty distributions that are used to plan uncertainty-reduction sampling. These data-driven and math-based models of three-dimensional sampling results produced well-bounded remedial volumes for project planning and better uncertainty predictions during project budgeting. The EBK method was applied to several FUSRAP sites managed by the Buffalo District and compared to less rigorously modeled sites previously remediated by the District. The comparison of modeled to actual remediated volumes provide a basis for validating the volume-estimation method. This comparison is important to ensure modeled volumes match physical boundaries of site remediation. FUSRAP sites with denser investigative sampling and lesser volume uncertainty proved useful in remedial planning and contracting. The Buffalo District noted that historical sites with sparser sampling arrays had greater disparity between estimated volumes and final remedial volumes. The benefit achieved over the cost of detailed soil sampling appears positive for FUSRAP projects, especially where impacts vary widely and appear unbounded by investigation-phase sampling. The subsequent Empirical Bayesian Kriging of contamination coupled with vertical contouring for soil estimations reduces uncertainty in soil volumes or indicates where sampling is required to reduce uncertainty, which together optimize remedial planning and budgeting. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct intratumoral infusion of liposome encapsulated rhenium radionuclides for cancer therapy: Effects of nonuniform intratumoral dose distribution

Purpose: Focused radiation therapy by direct intratumoral infusion of lipid nanoparticle (liposome)-carried beta-emitting radionuclides has shown promising results in animal model studies; however, little is known about the impact the intratumoral liposomal radionuclide distribution may have on tumor control. The primary objective of this work was to investigate the effects the intratumoral absorbed dose distributions from this cancer therapy modality have on tumor control and treatment planning by combining dosimetric and radiobiological modeling with in vivo imaging data. Methods: {sup 99m}Tc-encapsulated liposomes were intratumorally infused with a single injection location to human head and neck squamous cell carcinoma xenografts in nude rats. High resolution in vivo planar imaging was performed at various time points for quantifying intratumoral retention following infusion. The intratumoral liposomal radioactivity distribution was obtained from 1 mm resolution pinhole collimator SPECT imaging coregistered with CT imaging of excised tumors at 20 h postinfusion. Coregistered images were used for intratumoral dosimetric and radiobiological modeling at a voxel level following extrapolation to the therapeutic analogs, {sup 186}Re/{sup 188}Re liposomes. Effective uniform dose (EUD) and tumor control probability (TCP) were used to assess therapy effectiveness and possible methods of improving upon tumor control with this radiation therapy modality. Results: Dosimetric analysis showed that average tumor absorbed doses of 8.6 Gy/MBq (318.2 Gy/mCi) and 5.7 Gy/MBq (209.1 Gy/mCi) could be delivered with this protocol of radiation delivery for {sup 186}Re/{sup 188}Re liposomes, respectively, and 37-92 MBq (1-2.5 mCi)/g tumor administered activity; however, large intratumoral absorbed dose heterogeneity, as seen in dose-volume histograms, resulted in insignificant values of EUD and TCP for achieving tumor control. It is indicated that the use of liposomes encapsulating radionuclides with higher energy beta emissions, dose escalation through increased specific activity, and increasing the number of direct tumor infusion sites improve tumor control. For larger tumors, the use of multiple infusion locations was modeled to be much more efficient, in terms of activity usage, at improving EUD and TCP to achieve a tumoricidal effect. Conclusions: Direct intratumoral infusion of beta-emitting radionuclide encapsulated liposomes shows promise for cancer therapy by achieving large focally delivered tumor doses. However, the results of this work also indicate that average tumor dose may underestimate tumoricidal effect due to substantial heterogeneity in intratumoral liposomal radionuclide distributions. The resulting intratumoral distribution of liposomes following infusion should be taken into account in treatment planning and evaluation in a clinical setting for an optimal cancer therapy.

60 APPLIED LIFE SCIENCES↗

Characterization of the Uranium-Bearing Products of the Ammonia Injection Remediation Method - 15707

Commissioned in 1943, the Hanford Site is the home of the world's first full-scale nuclear production facility. After more than 40 years of processing, improper discharge and failed storage tanks have resulted in the contamination of the Hanford vadose zone with radiologically contaminated waste. Remediation methods considered for the area include sequestration of the mobile uranium by injection of ammonia (NH{sub 3}) gas. Injection of this reactive gas increases the pore water pH, promoting the dissolution of soil minerals; a subsequent re-establishment of natural conditions is believed to result in the recrystallization of those soil minerals and the co-precipitation of uranium phases. Characterization of the precipitates formed when the ammonia (NH{sub 3}) injection method, proposed for the Hanford vadose zone, is applied to synthetic pore water on a laboratory scale. This involves: Identification of the uranium-bearing phases; A study of the effect of pore water constitution on the phases produced. Synthetic pore water solutions were prepared to mimic selected constituents of the pore water from the Hanford 200 Area: Varying constituent concentrations; Observations led to modifications to increase relative uranium content: 200 ppm → 500 ppm U; Substituted sodium silicate for silicic acid. Dried samples were analyzed by SEM-EDS and powder X-ray diffraction (XRD). A suspension in ethanol was prepared and analyzed by Transmission Electron Microscope (TEM) with Selective Area Electron Diffraction (SAED). Studied and applied geochemical modeling software (Visual Minteq and Geo-chemist's Workbench) for speciation and prediction of potential species formed. Discussion/Conclusions: - SEM-EDS Analysis: Scanning electron microscopy revealed areas of high average atomic weight which would be confirmed to be uranium-rich by energy dispersive spectroscopy analysis. The samples prepared with a more than two-fold increase in uranium concentration did not show the crystal-like forms spotted in the lower [U] samples. The samples prepared with silicic acid substituted in showed little to no uranium precipitation [not shown]. - Diffraction Analysis: Powder XRD analysis of the low [U] samples confirmed the presence of repeating crystalline patterns in the precipitate samples. Nitratine (NaNO{sub 3}) showed a massive presence, potentially obscuring significant peaks in the low [U] samples. Though it was not predicted, there was a tentative match for cejkaite (Na{sub 4}(UO{sub 2})(CO{sub 3}){sub 3}). Elevated uranium samples showed none of the needle-like crystalline shapes [diffraction data pending]. TEM - SAED confirmed the presence of a polycrystalline phase. Data analysis is complex but a comparison of average d-spacings with those of reference minerals could further support a match with cejkaite. - Geochemical Modeling: The system conditions were input into geochemical modeling software to predict the forms present throughout the reaction process. The model was used to demonstrate that the pH of the system could be increased using [NH{sub 4}{sup +}] in solution to better represent the system. Using the [NH{sub 4}{sup +}] increase, the changes in significant species with increasing pH were observed. Future Work: Repeat samples will be prepared and analyzed to bolster any potential identification. Promising samples will be submitted to the PNNL's EMSL facility, which is better equipped to perform the required analyses. An expanded study on the impact of carbonate (CO{sub 3}{sup 2-}) on the phases produced.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A support vector machine (SVM) for predicting preferred treatment position in radiotherapy of patients with breast cancer

Purpose: NYU 05-181 protocol compared the CT simulation in both supine and prone positions for 400 patients with breast cancer (200 left-breast and 200 right-breast) to identify which setup is better at sparing heart and lung involvement in the treatment process. The results demonstrated that all right-breast patients benefited from the prone treatment position, while for left-breast patients, 85% were better treated prone and 15% were better treated supine. Using the clinical data collected from this protocol, the authors aimed at developing an automated tool capable of identifying which of the left-breast cancer patients are better treated supine without obtaining a second CT scan in the supine position. Methods: Prone CT scans from 198 of the 200 left-breast cancer patients enrolled in NYU 05-181 protocol were deidentified and exported to a dedicated research planning workstation. Three-dimensional geometric features of the organs at risk and tumor bed were extracted. A two-stage classifier was used to classify patients into the prone class or the supine class. In the first stage, the authors use simple thresholding to divide the patients into two groups based on their in-field heart volume. For patients with in-field heart volume {<=}0.1 cc, the prone position was chosen as the preferred treatment position. Patients with in-field heart volume >0.1 cc will be further classified in the second stage by a weighted support vector machine (SVM). The weight parameters of the SVM were adjusted to maximize the specificity [true-supine/(true-supine+false-prone)] at the cost of lowering but still maintaining reasonable sensitivity [true-prone/(true-prone+false-supine)]. The authors used K-fold cross validations to test the performance of the SVM classifier. A feature selection algorithm was also used to identify features that give the best classification performance. Results: After the first stage, 49 of the 198 left-breast cancer patients were found to have >0.1 cc of in-field heart volume. The three geometric features of heart orientation, distance between heart and tumor, and in-field lung were selected by the feature selection algorithm in the second stage of the two-stage classifier to give the best predefined weighted accuracy. The overall sensitivity and specificity of the proposed method were found to be 90.4% and 99.3%, respectively. Using two-stage classification, the authors reduced the proportion of prone-treated patients that need a second supine CT scan down to 16.3/170 or 9.6%, as compared to 21/170 or 12.4% when the authors use only the first stage (thresholding) for classification. Conclusions: The authors' study showed that a feature-based classifier is feasible for predicting the preferred treatment position, based on features extracted from prone CT scans. The two-stage classifier achieved very high specificity at an acceptable expense of sensitivity.

60 APPLIED LIFE SCIENCES↗